Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR | NAGPUR | MAHARASHTRA | 440036 | L1 | Accepted-AOC BEING LOWEST REASONABLE BIDDER | |
| 2 | L2₹19.4 L+₹88,449.06 (4.79%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹19.9 L+₹1.4 L (7.76%)Rejected-Finance MIG FLAT 6D POCKET I SECTOR 10 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹21.4 L+₹2.9 L (15.7%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹23.0 L+₹4.5 L (24.4%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
21 Jan 2025, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
PROVISION OF STANDBY DIESEL GENERATOR SET AT BUILDING P-30 M OF CNA (OF) JABALPUR UNDER GE(P) JABALPUR
2024_MES_689253_1
85189/P/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JABALPUR
PROVISION OF DG SET
7 documents required · 7 mandatory
₹500
Yes
GE(P) NO. 1 JABALPUR
₹46,000
Yes
15 Apr 2025
18 Dec 2024
23 Jan 2025
18 Dec 2024
21 Jan 2025
7 Jan 2025
18 Dec 2024 - 31 Dec 2024
Amount
Supply, Installation, Testing and Commissioning of silent Diesel Engine driven generating set not less than 125 KVA or nearest standard size, 415 volts, 3 phase 4 wire, 1500 rpm, 50 Hz power supply with power factor 0.8, coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design thereby facilitating /easy handling of installation & shifting of the equipment at site. The design of integral acoustic enclosure should be approved by National Physical laboratory as per Central Pollution Control Board (CPCB-IV + Emission compliant) latest norms/regulation Noise level 75dB(A) at a distance of one metre, with and including fuel tank, battery and standard accessories as recommended by Manufacturer, vibration pad, sand cushioning around PCC foundation, tools and spares, as provided by Manufacturer complete all as specified and as directed with the following specifications
ENGINE - 4 cylinders, inline, 4 stroke cycle, Water cooled Naturally aspirated, developing Matching 161.6BHP at 1650 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement & shall give the electrical output 125 KVA/ 100 KW at 0.8 power factor, Current 174 Amp, 415Volts at the alternator terminal
ALTERNATOR: Single bearing alternator suitable for continuous operation generating 125 KVA at 1650 RPM, 415Volts , 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system, conforming to BS 5000/ IS 4722. The alternator is brushless type, screen protected, revolving field, self excited alternator conforming to IS/IEC 60034-1, self regulated through an AVR. The alternator has the following features: (a) ± 0.50 % voltage regulation (max.) in static conditions (b) IP: 23 protection with insulation class 'H'. (c) Permissible overload of 10% for one hour in 12 hours of operation. (d) 3 phase reconnectable winding with 12 terminal brought out for connection. (e) Dedicated winding specially designed for 1 phase operation (f) Double layer lap startor winding (g) PCC foundation complete as per Manufacturer's design including anti vibration pads, necessary excavation & earth work in soft/loose soil, sand cushioning, grouting foundation etc.
Engine Starting – (a) The control system supports automatic engine starting, Primary and back up start disconnections are achieved by battery charging alternator feedback or main alternator output frequency. (b) Controller Model PS0602 provides configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal. (c) Sleep mode increases battery life. Configurable current settings from low to minimize current draw when genset is not working.
Engine Protective Functions includes - Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control (a) Low Lube oil pressure warning and shutdown (b) High engine water temperature warning/ shutdown (c) Low coolant temp warning (d) Sensor failure indication (e) Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down (h) Cranking lockout: Control will not allow the starter to engage or to crank the running engine (j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods. Alternator Protective functions includes (a) High and Low AC voltage shut down (b) Under and over frequency shutdown / warning (c) Loss of sensing voltage input shut down (d) Battery charger alternator
Fuel tank: (a) Sub Base Fuel tank of 14 SWG MS sheet of adequate capacity to operate 8 hrs to 12 hrs on 100% load. (b) Base Rail: Base Rail with integral fuel tank is provided. (c) Batteries: For electrical control circuit 12 Volts/88AH batteries for electrical starting of DG set
(n) 4 Point Alarm Annunciator with in-built hooter, test, accept and reset push button, 12V DC - 01 No (o) Solid State single element earth fault relay with 2C/o contact, CTR-250/5A AUX 230V AC - 01 No. (p) Suitable bus bar and control panel shall have suitable incoming / out going terminal control, circuit fuses, painted with powder coated, rust proof paint. (q) AMF controller, DG-6 type, 12V DC rating - 01 No (r) AUX relay, coil voltage, 12V DC 4 C/O, 14 Pin - 05 Nos (s) AUX relay, coil voltage, 240V AC 4 C/O, 14 Pin - 01 No (t) Thermal Overload relay, with in-built SPP feature, 3A-5A rating - 01 No
One set of accessories (As per manufacture's instruction) :- (a) Fuel tank with locking arrangement for 08 hours running on full load (b) Level indicator on fuel tank (c) Drain plug (d) MS Class "C" pipe of suitable dia and length for fuel inlet from tank to engine as per Manufacturer's instruction. (e) Fuel strainer and fuel tank with air vent. (f) Batteries heavy duty 24 Volts 180 AH lead acid type fully charged, indication of high flow charging changed : - 01 No (g) Cable connection from alternator to DG set control panel as directed
Tools (As per manufacturer's instructions):- (a) 'D' spanners - 01 Set (b) Ring spanners - 01 Set (c) Screw driver 5" to 12 " - 01 Set (d) Cutting plier 9 " - 01 No (e) Hammer 2 LBS - 01 No
Base frame arrangements . The engine and alternator would be coupled by means of specially designed flexible coupling. Both the units including the radiator would be mounted on a rigid fabricated base to form a compact arrangement. The steel shall be of Make : TISCO/SAIL or equivalent Make as approved by GE
Sound acoustic enclosure : CPCB approved sound acoustic enclosure suitable for above generator set with complete set installed within canopy.
Supply and laying in trenches/through pipes or laid across road /paths/drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. cable under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area 120 Sqmm x 3.5 core complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for shafts , wells, cesspits, manholes, laying of pipe and not exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified & diected.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose)
Supply and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
M&L for 100 mm thick PCC (1:2:4) Type B-1 using 20mm graded stone aggregate as in floor/hard standing complete all as specified and directed..
Supply and fix earth continuity conductor for main earthing lead 32 x 6 mm GI strip burried in ground or fix in walls with bolts complete all as specified and directed.
Supplying and fixing 80 mm bore, ISI marked steel tubes light grade galvanised with all fittings used for cable protection complete all as specified and directed.
Earthing complete for various equipments with galvanised steel earth plate electrode 600 x 600x 6mm thick directly burried in the ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 m below the ground level, connected to G.I Strip 32 x 6 mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light grade for protection of earthing strip, PCC chamber 1:2:4, type B-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge ( 0.63) 8 mesh per linear inch, 50mm thick cover of RCC 1:2:4, type B-1, using 20mm graded stone aggregate reinforced with 8mm TMT bar at 75mm C/C both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I(2009) and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on completion complete all as specified and directed. Note:- Unit rate quoted against this item is inclusive of earth lead and protection pipe upto 7.5 metre from earth plate.
Sachdeva Enterprises (BID ID -3213001)
Elmek Engineers (BID ID -3214181)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3214038)
C L BHATIA (BID ID -3213963)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3208125)
M/s Ajayshwar Singh Rana (BID ID -3213198)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .