Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L1 | Accepted-AOC Accepted being L-1 | |
| 2 | L2₹15.3 L+₹3,061.50 (0.20%)Rejected-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-AOC Not accepted being -L2 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PARTAPUR
GE PARTAPUR
PROVN OF WATER HEATING PLANT FOR SIACHEN BATTLE SCHOOL AT BASE CAMP UNDER GE PARTAPUR
2022_MES_538366_3
GE/P-49/2022-23
Open Tender
Civil Works
Works
183 days
GE PARTAPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE PARTAPUR
₹29,000
Yes
19 Oct 2022
15 Sept 2022
15 Oct 2022
15 Sept 2022
13 Oct 2022
29 Sept 2022
15 Sept 2022 - 20 Sept 2022
60 days
Amount
Hot water generator 2,00,000 kcal/hr Kerosene/Diesel operated 90 Degree C with heat exchanger, consisting of two closely wound, helical, concentric coils arranged to give three pass on flue gas and made of ERW tubes complete and shell assembly consisting of a single jacket, enclosing the heat exchanger coil to serve as an integral "Combustion chamber" duly insulated externally complete with mounting frame, piping air and fuel gas and inter connecting piping between pump outlet and inlet of hot water generator, Mounting & fittings Electrical ,Non Return valve at the fuel by pass line and Filter on fuel line, mounting & fittings i.e. Temperature indicator cum controller with 2 set points, one for burner ON-OFF control and the other for safety for high outlet water temperature, pressure gauges at fuel pump outlet, incl 100 Liters Diesel tank. A circulating pump with 3 phase 415 V 3 hp, 30 m head should be part of the hot water system connecting hot water to SM Barrack having Bathrooms ( approx. 100 m 32 mm PPR PN20 pipeline duly connected to toilets)An electric panel of 100 Amp MCCB 4P and three outgoings one each for DOL starter for 3 hp motor, Burner and Glycol pump along with earthing test point is included.
Supply and fixing in replacement of 3-layer PP-R Polypropylene random copolymer concealed piper SDR 7.4 ((PN-16) VU stabilized and antimicrobial dusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings 40 mm outer dia with all fitting laid in trenches or fixed to walls and ceiling or laid in floor complete all as specified and directed by Engr-in-Charge. Make : SFMC or equivalent
M&L for Elestometric Nytral rubber insulation to PP-R pipes suitable for 20mm outer dia 22/19mm thick with chiken wire mesh wire netting 25mm gauge, 20mm mesh with 0.01mm aluminium foil including jointing and fixing material such as solvent adhesive SR-998 complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable/pipes, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed.
Returing, filling in incl spreading, levelling watering and well ramming in layers n.exc 25cm width, Complete all as specified and directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted.
Supply and fix PPR Gate Valves (Brass insert) of 40 mm bore
Supply and fix of Puff Storage water tank HDPE 2500 Ltrs all as directed and specified.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 16 Sqmm x 4 Core cable all as specified and directed.
Sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable complete all as specified and directed by Engineer-in-Charge.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm Complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI earth wire 4 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion all as specified and as directed.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 using 20mm graded stone aggregate for LT panel board/poles foundation.
Deduct Schedule of Credit of Rs (-) NIL (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
national engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .