EE SDW V
Ring Road Andrews Ganj New Delhi 110049
Providing Fixing of Cable Trays at Aeration Unit and Primary Grit Chamber of Ghitorni STP
2024_DJB_257286_4
N.I.T. No. 02 2024 25
Open Tender
Miscellaneous Works
Works
30 days
Ring Road Andrews Ganj New Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Indian Bank
₹9,700
19 Jun 2024
6 Jun 2024
12 Jun 2024
6 Jun 2024
12 Jun 2024
6 Jun 2024
Dismantling of existing old cable trays and unclamping of aluminum cables(8 No. Aerator Cables & 8 No. Light Cables.) from existing damaged cable trays and temporarily clamping them to M.S. railing with suitable G.I. wires without disturbing the smooth functioning of aerators.
Providing and fixing of clamps for the new cable trays with the help of tools and tackles, manual / heavy labour as per site requirement and direction of engineer in charge.
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.6.2
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.6.4
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.7.2
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.7.4
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.8.2
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.8.4
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray cross member (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.9.2
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray cross member (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.9.4
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray Reducer (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.10.2
Supplying and installing 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray Reducer (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required DSR 4.10.4
Safety Arrangement as per NHRC guidelines at site of work for safe working of men & machinery. This includes transportation of safety material its loading unloading etc. complete for making safety arrangement at site.
HYDROCON ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .