Package I Replacement Upgradation of existing SCADA EMS at ERLDC and SLDCs in Eastern Region under Implementation of Unified Load Despatch and Communication (ULDC) Phase III (SCADA EMS upgradation project) Eastern Region
CC/NT/W-SCADA/DOM/A06/23/05954
Open
Power/Energy Projects/Products
Works
Bihar, Odisha, SIKKIM, West Bengal, Jharkhand
₹25,000
2 Aug 2024
18 Jul 2023
15 May 2024
18 Jul 2023
15 May 2024
18 Jul 2023
9 Apr 2024
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
SAN management server along with SAN Box and mass storage (SAN) for IT side
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS
LED VPS
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (4*3) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
120 kVA UPS System
120 kVA (96 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 230.4 kVAH)
Input ACDB (600 KVA rating)
Output ACDB (400 kVA rating)
Workstation Console for UPS monitoring
Workstation
Single monitors for workstation
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
Workstation Console for UPS monitoring
Workstation
Single monitors for workstation
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System (VCS)
VCS for Location 1
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
VCS for Location 2
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
VCS for ERPC
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Warehouse storage of all supplied system under the Project (as per actual)
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
SAN management server along with SAN Box and mass storage (SAN) for IT side
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS
LED VPS
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (4*3) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
120 kVA UPS System
120 kVA (96 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 230.4 kVAH)
Input ACDB (600 KVA rating)
Output ACDB (400 kVA rating)
Workstation Console for UPS monitoring
Workstation
Single monitors for workstation
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
Workstation Console for UPS monitoring
Workstation
Single monitors for workstation
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System (VCS)
VCS for Location 1
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
VCS for Location 2
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
VCS for ERPC
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Warehouse storage of all supplied system under the Project (as per actual)
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Remote Console
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Remote Console
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with Single Monitors
Workstation
Dual monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS
LED VPS
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temperature
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG set
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) in Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Integration with Market and Metering Applications
Integration with Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with Single Monitors
Workstation
Dual monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS
LED VPS
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temperature
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG set
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) in Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Integration with Market and Metering Applications
Integration with Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Hardware
RTU & associated items
RTU base equipment as per technical specification
CPU Cards
Digital Input Module
Digital Output Module
Analog Input Module
Multi Function Transducers
Weather Sensor
OLTC Transducer
Contact Multiflying Relays (CMRs)
Time Sychronization Equipment without Display
Heavy Duty Relay
Supervisory Interface Cubicles(SIC) panel for mounting MFTs, CMR etc if required
LDMS System Along with software
Furniture for LDMS system(1 Table &1 Chair)
Inverter for LDMS
Cables for RTU
Laptop for PCMT
Services
Integration with Control Centres (SLDC/RLDC) on IEC104 at substation & control centre
Annual Maintenance Contract
Integration of new bay(Including supply & commissioning of each type Cards, MFT, CMR,Cables etc) at RTU site
RTU maintenance (1 Years)
RTU maintenance (6 Years)
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Remote Console
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
Maintanance of existing VPS with all required software
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
32 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Remote Console
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
250 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
Maintanance of existing VPS with all required software
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Hardware
RTU & associated items
RTU base equipment as per technical specification
CPU Cards
Digital Input Module
Digital Output Module
Analog Input Module
Multi Function Transducers
Weather Sensor
OLTC Transducer
Contact Multiflying Relays (CMRs)
Time Sychronization Equipment without Display
Heavy Duty Relay
Supervisory Interface Cubicles(SIC) panel for mounting MFTs, CMR etc if required
LDMS System Along with software
Furniture for LDMS system(1 Table &1 Chair)
Inverter for LDMS
Cables for RTU
Laptop for PCMT
Services
Integration with Control Centres (SLDC/RLDC) on IEC104 at substation & control centre
Annual Maintenance Contract
Integration of new bay(Including supply & commissioning of each type Cards, MFT, CMR,Cables etc) at RTU site
RTU maintenance (1 Years)
RTU maintenance (6 Years)
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Software
SCADA Software
Load Shed Support(LSS)/ADMS
SOFTWARE FOR ICCP COMMUNICATION
SOFTWARE FOR CFE COMMUNICATION
EMS Functions
State Estimator
Contingency Analysis
Security Enhancement
Optimal Power Flow
Outage Scheduler
Transmission Line/Corridor Capability Monitor (TCM)
Short Circuit Analysis
Automatic Generation Control (AGC)
Dynamic Security Assessment (DSA) Software
Dispatcher Training Simulator Software
Database development system (PDS) cum test bench for SCADA and ICCP Integration
Database development system (PDS)
Test bench FEP, SCADA & ICCP Intg
Web Server Application
Data Replica system software
Web Server system software
Web Historian and Reporting System
OPC client licenses (SCADA & Historian 5 each) - To take data from outside.
SMS & Email Interface
Commercial Off-The-Shelf (COTS) Softwares
SOFTWARE FOR DATA HISTORIAN
Document Management System
Identity Management Software
Network Access Control (NAC)
Patch Management Software
VAPT Tool
Virtualisation Software for all the virtual servers envisaged and required under the project along-with centralised management software
Operating System for all the servers envisaged and required under the project
Host based intrusion prevention system (HIPS) with centralised management
End Point Security Solution with centralised management
Centralised Management and Log Analyser of all FWs
Network Management System
SIEM (Security Information and Event management)
OPC client licenses to be installed outside OT network to exchange data from SCADA & Historian
Load Forecasting
OPC server
Report Development & Generation Software
Storage system
SAN Software
NAS Software
Hardware
SCADA/EMS Server
Dynamic Security Assessment (DSA) Server
ICCP, CFE, OPC Server
ICCP, OPC communication Server
Communication Front End (CFE) Server
Data Historian Server/Data Storage Server
DTS Server
PDS (test & development) server
Third Party Applications Servers as per technical specification
End Point Security Solution Server
Patch management Server
NMS server
VAPT server
Management Applications Servers as per technical specification
Internal Centralised Mangement Server
Network Access Control (NAC)
Identity Management Server
DRS DMZ Servers as per technical specification
External Centralised Mangement Server
Data Replica Server
Document Management System
External DMZ Servers as per technical specification
Web Servers
End Point Security Solution Server
Patch management Server
Web Historian and Reporting server
OPC Server
Server Mangement Console
Backup Solution
Storage system
SAN management server along with SAN Box and mass storage (SAN)
Nas Box
WAN Routers with Firewall
WAN Router cum Firewall for ICCP Communication
WAN Router cum Firewall for External World Connectivity
WAN Router cum firewall for RTU Communication
Router cum firewall for Remote Consoles
WAN Router cum firewall for PDS
Switches
48 Port L3- LAN switch for SCADA/EMS LAN
24 Port L3- LAN switch for Historian & Reporting LAN
16 port FC switch for SAN Switch
24 Port L3- LAN switch for Internal & External DMZ LAN
24 Port L3- LAN Switch for Server Management LAN
24 Port L3- LAN Switch for ICCP & FEP LAN
24 Port L3- LAN Switch for DCPC/Terminal Server LAN
48 Port L3- LAN Switch for Terminal Server
24 Port L3- LAN Switch for Terminal Server
Cyber Security Appliances
External Firewall with NIPS and centralised mangement
Internal Firewall with NIPS and centralised mangement
External Firewall with NIPS for ICCP/RTU and centralised mangement
Anti-APT
Laptops
Laptop for maintenance
Laptop for DTS
Laptop fot VAPT
Data Concentrator PC (DCPC) as per technical specification
Industrial grade Computer with 4 LAN and 2 Serial Ports
8 Port 10/100 Mbps Ethernet switch with RJ 45 Ports
GPS based time synchronisation system
16 Port Splitter
32 Port Terminal Servers
16 Port Terminal Servers
Panel for Terminal Servers with accessories
Workstations
Workstation Console without Monitor
Workstation Console integrated with dual Monitors
Workstation
Dual monitors for workstation
DTS Workstation with dual Monitors (Training Console)
DTS Workstation console
Dual monitors for DTS
Workstation Console integrated with dual Monitors for DSA (at RLDC only)
Workstation Console for DSA
dual Monitors for DSA
PDS Workstations with dual Monitor
workstation for PDS
Dual monitor for PDS
Workstation Console integrated with single Monitors
Workstation
Single monitors for workstation
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
All-in-One workstations with CPU (remote console)
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Video Projection System
Laser VPS (Modules)
LED VPS (Modules)
Video wall
55” Tower Type Video Wall with CPU (with proper stand)
55” Wall mounted Video Wall with CPU (with proper mounting)
55” (3*3) Wall mounted Video Wall with CPU (with proper mounting)
55” (3*2) Wall mounted Video Wall with CPU (with proper mounting)
55” (2*2) Wall mounted Video Wall with CPU (with proper mounting)
Printers
Color Laser Printer
Multi Functional Printer
A4 Size Multi Functional Display Printers
Time & Frequency System and External displays
Time & Frequency System NavIC(with failback to GPS)Based
Digital Display for Date
Digital Display for Day
Digital Display for Time
Digital Display for Frequency
Digital Display for Time Block
Digital Display for Temprature
Digital Display for Humidity
Furniture
U-Type Operator Workstations desk (per cubicle 9-10 feet)
Operator Workstations desk
Operator Workstations desk-Motorized
Operator Workstations desk-Normal
Chairs
printer Table
Weather Sensors for Server Room
Link Load Balancer
Smart server rack
IP based KVM system
Centralized keyboard & mouse control solution (CKMC)
External HDD
Auxiliary power Supply
80 kVA UPS System
80 kVA (64 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 153.6 kVAH)
Input ACDB (350KVA rating)
Output ACDB (300 kVA rating)
60 kVA UPS System
60 kVA (48 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 115.2 kVAH)
Input ACDB (250 kVA rating)
Output ACDB (200 kVA rating)
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
20 kVA UPS System
20 kVA (16 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 38.4 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
DG System
50 KVA DG Set
100 KVA DG Set
125 KVA DG Set
160 KVA DG Set
200 KVA DG Set
320 kVA DG Set
48V DC Power Supply (DCPS) for Substations
SMPS based 48V DC Power Supply (DCPS) system of 35 Amp rating
VRLA type Battery bank for above DCPS system of 450AH Rating
SMPS based 48V DC Power Supply (DCPS) system of 25 Amp rating
VRLA type Battery bank for above DCPS system of 600AH Rating
VRLA type Battery bank for above DCPS system of 400AH Rating
Test Equipment for RTU
Master Station cum RTU simulator & ProtocolAnalyser Software tool.
Laptop PC for above software tools along with interfacing hardware
Video Conferencing System
Multi-Point Conferencing Unit
Configration Laptop with associate Accessories
Video End Points
HD camera
Micophone basestation
Wireless Microphone
Collar Microphones
LCD Video walls
Wall Mounted Line array speakers
Dual Channel Power Amplifiers
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for SCADA/EMS system
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
Mandatory Spares for DG Set & AMF Panel for control centres
Mandatory Spares for RTU
Mandatory Spares for DCPS
Services
Integration with Control Centres/other system on ICCP on ICCP
Integration with other Applications/Systems
Market and Metering Applications
Scheduling software
Integration of SCADA/EMS system on OPC/Modbus/web services
Existing RTU Integration
Integration Existing RTU with Data Concentrator Cum Protocol Convertor
Cyber Security Audit by CERT -IN certified Auditors during FAT
Cyber Security Audit by CERT -IN certified Auditors during SAT
Integration with existing VPS with all required software
Dismantling and Buyback of existing SCADA/EMS system
SMS integration with service provider Email integration with owner email system
Training
Training on Computer System Hardware & Software
Training on Database & Display
Training on Application Software
Training on Dispatcher/Operator
Training on NMS
Training on Cyber Security and VAPT
Training on Dispatcher Training Simulator
Training on Terminal/DCPC/ICCP Server Course
Training on Auxiliary Power Supply
Training on VC
Training on RTU
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project during Warranty Period
Annual maintenance contract of SCADA/EMS System and all the equipment supplied in the project after expiry of Warranty Period
ICCP Integration for 7 years (Per ICCP Integration)
Six Monthly Cyber Security Audit by Cert-IN certified Auditors
Patch Management including Signature updates for all Cyber security equipments for 7 years
Integration of RTU with SCADA during AMC
OPC client function (per user) in SCADA Server
Integration of SCADA/EMS system on OPC/Modbus/Web services/SAMAST during AMC including DLP
Yearly Training on SCADA/EMS for 5 Days for 20 people
Catridges
Catridges- Cyan/Magenta/Yellow (Set of All)
Catridges- Black
Drum- Cyan/Magenta/Yellow (Set of All)
Drum- Black
Relocation and Commissioning at New Location
Relocation and Commissioning at New Location- All the systems supplied under this project except VPS and APS
Relocation and Commissioning at New Location- video Projection System
Relocation and Commissioning at New Location- Auxilliary power supply
SMS Service of 1 Lakh messages annually
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Hardware
Firewall with NIPS and centralised mangement
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Router cum firewall for Remote Consoles
24 Port L3- LAN Switch for Remote Console
Video Projection System
Laser VPS (Modules)
Printers
A4 Size Multi Functional Display Printers
Auxiliary power Supply
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Schedule-1
Item Description
Hardware
Firewall with NIPS and centralised mangement
Remote Consoles
Remote Console with Dual monitor
Remote Consoles with CPU (Dual monitor)
Dual monitor for remote console
Remote Consoles with 55" Monitor with CPU
Remote Consoles with CPU (55" monitor)
55" monitor for remote console
Router cum firewall for Remote Consoles
24 Port L3- LAN Switch for Remote Console
Video Projection System
Laser VPS (Modules)
Printers
A4 Size Multi Functional Display Printers
Auxiliary power Supply
40 kVA UPS System
40 kVA (32 kW at 0.8 pf) UPS running in parallel
VRLA type Battery banks for UPS (each bank of atleast 76.8 kVAH)
Input ACDB (150 kVA rating)
Output ACDB (100 kVA rating)
Accessories for maintenance of VRLA type batteries
Power Distribution and cabling work required to establish UPS
Mandatory Spares (As per Techincal Specification)
Mandatory Spares for VPS
Mandatory Spares for Auxiliary Power Supply system for the control centres
The following mentioned requirements are applicable to BoQ of all constituents specified under Appendix-G.
Above mentioned requirements are minimum, however, if bidder feels that some additional hardware/software is also required to meet the technical specification requirements. Same may be considered by the bidder without any additional cost to the Owner
All the supplied system shall be under OEM (Hardware and Software) warranty & support till the completion of entire contract period.
During entire contract period, if OEM discontinues/ ends support to any item supplied (software/hardware/security solution) under the contract, contractor has to replace such hardware, software (or both, depending on software or hardware dependency) without any additional cost to Owner. Replacement shall be of either same or higher configuration keeping required performance specified under the contract and from same OEMs
Bidder has to submit annually documentary evidence for the availability of OEM supports for the supplied items including continuity of security patches.
Commercial Off-The-Shelf (COTS) product means bidder has to quote product which is independently commercially available in the market. For all such products bidder has to provide at least three references in Govt/Public Listed companies at the time of bid submission and same shall have been sold as an independent product and solution shall be in successful operation for at least three years at the time of bid submission. For that Bidder has to submit copy of PO/LOA and installation/completion/ operational certificate issued by Customer for the relevant reference.
Prices mentioned during AMC period shall be released on actual basis asand-when services will be availed.
Bidder shall mention country of origin for each of the items proposed under the contract
Price of all the client licenses shall be included in end-point equipments (Laptops, Workstation etc) for which unit prices has not been asked in BoQ separately.
Configuration of Servers and Applications shall be configured as per the proposed architecture (as an critical and non-critical) and non-critical applications shall be distributed between redundant physical servers for proper utilisation of both the servers.
List of Mandatory Spares to be supplied under the project has been mentioned in Maintenance and Support Spares. If quantity for any line item is considered as zero then spares shall not be considered for that line item and price shall be quoted accordingly.
Virtualisation Software shall be considered for all the servers on which virtualisation is required as per design and architecture to meet the technical specification requirements stated in various sections.
Operating System (OS) shall be considered for all the servers (Physical as well as virtual) as per design and architecture to meet the technical specification requirements stated in various sections.
Host Based Intrusion Prevention System (HIPS) shall be provided for all machines on DMZ LANs and machines interacting from outside the network (ICCP & FEP server) and for rest of the systems End Point Security Solution shall be provided.
(Signature)….....................................
(Printed Name)…..............................
Package - I: Replacement/Upgradation of existing SCADA/EMS at ERLDC and SLDCs in Eastern Region under ‘Implementation of Unified Load Despatch and Communication (ULDC) Phase-III (SCADA/EMS upgradation project)-Eastern Region
CC/NT/W-SCADA/DOM/A06/23/05954
Fill up only green shaded cells in the relevent attachments.
Attachments 2(JV), 2(QR), 3, 3(A), 4, 4(A), 5, 7, 8, 9, 10, 11, 12, 14, 15, 16, 17 and Bid Form for 1st Envelope are included here.
Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
Attachment 12 Integrity Pact : To be submitted as per ITB Clause No. 9.3(l). (format given in the Vol.-III of Bidding Documents).
Attachment 13 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
Attachment 17 Safety Pact : To be submitted as per ITB/BDS Clause No. 9.3(q). (format given in the Vol.-III of Bidding Documents).
Attachment-18, Attachment-19 and Attachment-20, Attachment-21 format given in the Vol.-III of Bidding Documents.
Schedule-1 [Bill of Quantity (BOQ) (Unpriced)]: To be submitted as per ITB/BDS Clause No. 9.3(u). (excel given in the Vol.-III of Bidding Documents)
Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
Sole Bidder
2 or More
Sole Bidder
Attachment-2(JV)
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-2(QR)
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Schedule-QR 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Sole Bidder
Attached copies of original documents of Sole Bidder/ all Partner of the JV (if applicable) with the help of "Attach" Buttons provided in the table given herebelow in PDF format
The constitution or legal status;
The principal place of business;
The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
Important:
Bidders submitting their Bids in Joint Venture may note that they have to furnish the JV Agreement and Power of Attorney of JV in line with the provisions of Bidding Document alongwith Bid Security and Integrity Pact in physical form before deadline for submission of hard copy of documents.
Attach written Power of Attorney of the Signatory of the Bid (For sole bidder / Lead Partner of the JV) and signatories of other partners of the JV (Signing the JV Agreement / Attorney of the JV)
GENERAL INFORMATION
Particulars
For Partner – 1
Name of the Firm
Head Office/ Registered Office Address
Telephone
Contact Person
Place of Incorporation/ Registration
Year of Incorporation/ Registration
Nationality of
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
Case_Studies.pdf
TECHNICAL REQUIREMENTS
Technical Experience
{Reference para 1.1 of Annexure-A (BDS)}
The bidder shall have Successfully completed # physical construction of transmission line project(s) involving tower foundation, erection and stringing of not less than following cumulative route length of 345/400 kV Double Circuit or higher voltage class transmission line as a prime contractor or as a partner in a joint venture+ within the last seven (7) years as on the originally scheduled date of bid opening i.e. 07.04.2015.
The bidder should have strung not less than cumlative route length of fifty(50)Kms transmission lines involving Quad bundle conductor per phase with tension stringing equipment as on the originally scheduled date of bid opening as mentioned above.
Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (7) years. The information is to be summarised for each such contract separately. (In case of Joint Venture bidder, the information/details pertaining to each partners of the joint venture are to be furnished).
Single Firm
Name of Contract Undertaken/Name of Transmission line/projects
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (ii) of 2.1.1)
(In Meters.)
(In Meters.)
(Yes/No)
(In Nos.)
(In Meters.)
(In Meters.)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
KRA.pdf
Single Firm
Name of Contract Undertaken/Name of Transmission line/projects
Contract Reference No. & Date of Award
Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
Scope of work executed under the above contract (Tick only whichever is/are applicable)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (i) of 2.1.1)
(In kms.)
(In Nos.)
(Yes/No)
Details/features of the Contract undertaken relevant to the stipulated QR (as in Sl No (ii) of 2.1.1)
(In Meters.)
(In Meters.)
(Yes/No)
(In Nos.)
(In Meters.)
(In Meters.)
(Yes/No)
(In Meters.)
Date of Completion of Contract
Details of documents furnished in the Bid, in support of the aforesaid data/details/information
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Case_Studies.pdf
Manufacturing Facilities
{Reference para 1.2 of Annexure-A (BDS)}
The Bidder should have its own manufacturing facilities for the Transmission Line towers and tower parts having the following minimum manufacturing capacities and manufacturing experience :-
Alternatively, the bidder should have assured access from tower manufacture(s) (one or two for each package) collectively meeting the requirement of para 1.2(a) (i) & (ii) above. In such a case, the bidder shall furnish a Joint Deed of Undertaking (Format enclosed) along with the manufacturer(s) in the bid to guarantee quality & timely supply of tower parts and confirming to furnish a performance guarantee of 2% of the cost of such tower parts from each of the manufacturer(s). This will be in addition to 10% contract performance guarantee to be submitted by the contractor on award of contract. However, one of the manufacturer including bidder (Manufacturer A) may be having established manufacturing facilities for tower parts but may not have manufacturing experience subject to following conditions:-
The bidder is required to furnish data/details/information relevant to the stipulated QR as follows:
Whether tower parts are proposed to be supplied by bidder himself.
Whether tower parts are proposed to be supplied by other manufacturers.
Name Such Manufacturer
Whether the Joint Deed of Undertaking alongwith the manufacturer(s) to guarantee quality & timely supply of tower parts, as per format at Section-VI, `Sample forms and procedures’, has been furnished with the bid.
Manufacturing Capacities for tower/tower parts of bidder or other manufacturer, as the case may be are to be furnished in the following format:
Name of the Manufacturer (name of bidder may be written if bidder himself is proposing to supply tower parts)
Address of the Manufacturer
Manufacturing Capacity per year
Qty. Manufactured in last three years
Details of year wise current commitments of Manufacturing of Tower / Tower Parts in (MT)
Against POWERGRID Contracts awarded till date (Fill the date in next cell)
Against Contracts of other Utilities as on date of Bid Submission(excluding outsourced qty.)
Monthwise Declarations for above Yearly Commitments
KRA.pdf
Manufacturing Capacities for tower/tower parts of bidder or other manufacturer, as the case may be are to be furnished in the following format:
Name of the Manufacturer (name of bidder may be written if bidder himself is proposing to supply tower parts)
Address of the Manufacturer
Manufacturing Capacity per year
Qty. Manufactured in last three years
Details of year wise current commitments of Manufacturing of Tower / Tower Parts in (MT)
Details of Tower supply against POWERGRID Contracts
Name of Line/Pkg.
new.pdf
Equipment Capabilities
{Reference para 1.3 of Annexure-A (BDS)}
In accordance with the above, the bidder shall provide adequate information as per following:
Capacity of TSE
Name of the Manufacturer
Model & Rating
Current Location
Commitment Details
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
Case_Studies.pdf
Capacity of TSE
Name of the Manufacturer
Model & Rating
Current Location
Commitment Details
new.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\Case_Studies.pdf
Case_Studies.pdf
Financial requirement
{Reference para 1.4 of Annexure-A (BDS)}
Net worth for last 3 financial years should be positive.
Minimum Average Annual Turnover *(MAAT) for best three years i.e. 36 months out of last five financial years of the bidder should be
Bidder shall have liquid assets (L.A) or/and evidence of access to or availability of credit facilities of not less than
In support of its ‘Financial Position’, in line with the above, the Bidder (Individual firm or all the JV partners in case of JV bidder) must provide the relevant information, alongwith documentary evidence, in the following formats A & B:
For Partner – 1
Average Annual Turnover details:
Financial year
Liquid Assets
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
new.pdf
Joint Venture (JV) Firms
In case a bid is submitted by a Joint Venture(JV) of two or more firms as partners, joint venture must comply with the following minimum criteria:
All the partners of the JV shall meet individually the Financial Position criteria given at 3.1 (a) above.
The lead partner of Joint Venture shall meet not less than 50% of the Technical Experience criteria given at Para 2.1.1(i) above and not less than 40% of the Financial position criteria given at Para 3.1 (b) & (c) above.
Each of the other partner(s) shall meet individually not less than 25% of the Technical Experience criteria given at Para 2.1.1(i) above or not less than 50% of Manufacturing facilities criteria given in para 2.2 above and not less than 25 % of the Financial position criteria given at Para 3.1 (b) & (c) above.
In case the JV intends to participate in the package proposing supply of tower parts from a manufacturer(s) then the manufacturer(s) shall meet the Manufacturing Facilities criteria given at para 2.2.1 above.
The joint venture must collectively meet the criteria of para 2.1.1, 2.2.1, 2.3 and 3.1 above for which purpose the relevant figure of Technical Experience, Manufacturing Facilities, Equipment Capabilities and Financial Position (Para 3.1(b) & (c)) for each of the partners of the JV shall be added together.
In case of Joint Venture, the following conditions shall also apply:
In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the corresponding documents are attached with the help of "Attach" Buttons provided at relevant sections above . Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents attached are to be indicated below:
Doc Name
F:\KRA.pdf
F:\KRA.pdf
KRA.pdf
The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
For Partner – 1
Years preceding to the bid opening
F:\Orissa C\Rev\KRA.pdf
Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\new.pdf
KRA.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Case_Studies.pdf
F:\HVDC-Champa-Kurukshetra\Rev Bidding Doc\TW04\KRA.pdf
Case_Studies.pdf
Financial Qualification Data {Reference para 2.0 (a), (b) & (c) of Annexure-A (BDS)}:
Financial Parameters
Net Worth
Paid Up Capital
Free Reserves and Surplus *
Misc expenses to the extent not written off
Annual Turnover **
Liquid Assset (Total Current Asset - Inventories)
Free Reserve and Surplus should be Exclusive of Revaluation Reserve, written back of Depreciation Provision and Amalgamation.
Annual total Income/turnover as incorporated in the Profit and Loss Account excluding non recurring income, i.e. sale of fixed asset etc.
Bidder shall furnish a CA certificate in regard to the above details.
Printed Name :
Designation :
Attachment-3 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Equipments & Materials produced in [Name of countries]
[Name of Countries]
Printed Name :
Designation :
country.
Attachment-3(A) 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
For Equipment
Printed Name :
Designation :
Attachment-4(B) 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-4
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Item Description
Nationality
FALSE
Item Description
Address
Printed Name :
Designation :
Annexure I to Attachment-4
Item Description
Nationality
Printed Name :
Designation :
Annexure I to Attachment-4
Item Description
Nationality
Printed Name :
Designation :
Attachment-4A
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Item Description
Category
FALSE
Item Description
Address
Printed Name :
Designation :
Annexure I to Attachment-4A
Item Description
Nationality
Printed Name :
Designation :
Annexure I to Attachment-4A
Item Description
Nationality
Printed Name :
Designation :
Attachment-5
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Reference clause in the Specifications
Printed Name :
Designation :
Annexure I toAttachment-5
Reference clause in the Specifications
Printed Name :
Designation :
Attachment-7
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Description of the Question
FALSE
Item Description
Address
Printed Name :
Designation :
Annexure I to Attachment-7
Item Description
Nationality
Printed Name :
Designation :
Annexure I to Attachment-7
Item Description
Nationality
Printed Name :
Designation :
Attachment-8
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Description of Work
Detailed Engineering and drawing submission
Equipment Design and Specification
Procurement of raw materials
Type Tests
Manufacturing
Factory Test
Shipments & Delivery at site
Establishment of Site Office
Installation at Site
Testing & Pre-commissioning
Parralel Operation
Printed Name :
Designation :
Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Attachment-09
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-10
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
Printed Name :
Designation :
Attachment-10
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-10
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-11
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-12 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of Materials
Towers
For Fabricated Tower Parts (including bolts & nuts)
Steel Blooms, co-efficient a =
Electrolytic High Grade Zinc, co-efficient b =
Labour, Co-efficient l=
LINE MATERIALS
G. S. Earthwire
Raw Material
High Tensile Steel galvanized wire, coeffcient a=
Labour, coefficient l =
Flexible Copper Bond
For Erection Price Component
Installation Price Component {including civil works but excluding ‘supply & placement of reinforcement steel’, ‘concreting’, survey, soil investigation and aviation signal for river crossing towers(if any)}
High Speed Diesel, coefficient a =
Labour, coefficient l =
Supply & Placement of Reinforcement Steel
High Speed Diesel, coefficient a =
Labour, coefficient l =
Ferrous Metals, coefficient b =
For Concreting
High Speed Diesel, coefficient a =
Labour, coefficient l =
Cement & Lime, coefficient b =
Structural Clay Products, coefficient c =
Printed Name :
Designation :
Attachment-12
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
The requisite format of Integrity Pact is getting generated automatically and displayed here below.
Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
For further details bidders may please refer ITB Clause 9.3 (n).
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 1 of 8
POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 2 of 8
The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 3 of 8
If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 4 of 8
If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 5 of 8
The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 6 of 8
The word ‘IEM’ would include both singular and plural.
This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
Changes and supplements as well as termination notices need to be made in writing.
If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature)
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Page 7 of 8
Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature
(For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal)
Designation :
Witness 1 :
Designation :
Witness 1 :
Designation :
Page 8 of 8
Attachment-14
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
Name of the Supplier/ Contractor in whose favour payment is to be made
Address with PIN Code and State
Status – Company/others
Permanent Account (PAN) No.
GSTN Numbers
GSTIN in the States/UT from where the supply of goods take palce
GSTIN number
GSTIN in the States/UT from where the supply of services take place (states where sites under the subject package is situated)
GSTIN number
Rajasthan
PF Registration No. of the Company
PF Regional Office covered (with Address)
Name of Contact Person
Contact Details
Bank Details for Electronic Payment
Current Account
9 digit MICR code printed at bottom in middle, next to cheque no.
IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
Printed Name :
Designation :
Attachment-15
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
The Bidder shall furnish
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format)
Details of Banker:
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Letter Ref.
As per para BDS/ITB clause 9.3(q), bidder shall furnish the details of their Provident Fund Code Number
Name of Bidders/ JV Partners
Litigation History
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Name of client, cause of litigation/arbitration and matter in dispute
Details regarding previous transgressions of Integrity Pact
Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years:
Name of client
OTHER INFORMATION
Current Contract Commitments of works in progress
Value of outstanding work (Rs.)
Financial Data:
Actual (Previous five years)
Printed Name :
Designation :
Attachment-16
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Printed Name :
Designation :
Attachment-16
Gurgaon (Haryana) - 122001
Name of the person with designation in POWERGRID
Printed Name :
Designation :
Attachment-16
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name of the person with designation in POWERGRID
Printed Name :
Designation :
ATTACHMENT-17
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Name and Address of the Indian Agent:
Services to be rendered by the Indian agent:
Indian agent’s Income-tax Permanent Account Number:
Bidder’s Income-tax Permanent Account Number in the Employer’s Country:
Printed Name :
Designation :
Attachment-17
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Attachment-18 0
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Printed Name :
Designation :
Tick whichever is applicable:
CC/NT/W-SCADA/DOM/A06/23/05954
thirteen
fourteen
Package - I: Replacement/Upgradation of existing SCADA/EMS at ERLDC and SLDCs in Eastern Region under ‘Implementation of Unified Load Despatch and Communication (ULDC) Phase-III (SCADA/EMS upgradation project)-Eastern Region
Enter details here.
Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, engineering, manufacture, testing, supply on F.O.R. destination site basis including transportation & insurance, storage, erection, demonstration for acceptance and commissioning (including carrying out Performance & Guarantee Test as per provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents.
Attachments to the Bid Form
Pay Order
A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us.
The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (b) & (c) of BDS, the qualification data has been furnished as per your format enclosed with the bidding documents [Attachment – 2(QR)].
The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facility offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 3. Moreover, a list of Special Tools & Tackles to be furnished by us in case of award, is also enclosed as per your format as Attachment 3A.
The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. The details of Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises as per your format as Attachment 4A.
The variation and deviations from the requirements of the Conditions of Contract, Bid Data Sheet and other commercial conditions, Technical Specification and Drawings in your format enclosed with the Bidding Documents.
The details of Alternative Bid made by us indicating the complete Technical Specifications, the Bid price for the Alternative Bid and the deviation to contractual and commercial conditions.
Answers to Questionnaire, as per technical specifications.
Work Completion Schedule.
Guarantee Declaration.
Information regarding ex-employees of POWERGRID in our firm.
Declaration regarding Social Accountability
Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
Manufacturer’s Authorization Form.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance), Information for e-payment, PF details and declaration regarding Micro/Small & Medium Enterprises.
Additional Information
Declaration for tax exemptions, reductions, allowances or benefits.
Safety Pact, in a separate envelope, duly signed on each page by the person signing the bid.
Declaration of Key Managerial Person jointly with Power of Attorney holder
Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
Certification by the Bidder as per DoE Order in line with ITB Clause 2.1
Non Disclosure Agreement
Bill of Quantity (BOQ) (Unpriced)
We are a Micro and Small Enterprise (MSE) registered with
SCHEDULES
Bill of Quantities (unpriced): In line with the requirements of the Bidding documents, we enclose herewith the unpriced Bill of Quantity indicating item-wise break-down for each constituent and the item description, country of origin, type & designation, quantity etc. duly filled-in as per the Proforma given in Schedule-1, Section-I of Bid Form & Price Schedule, Volume-III of the Bidding Documents.
We are aware that the Price Schedules and the Bill of Quantities given in the Bidding Documents do not generally give a full description of the Work to be performed under each item and we shall be deemed to have read the Technical Specifications and other sections of the Bidding Documents and Drawings to ascertain the full scope of Work included in each item while filling-in the rates and prices in Second Stage (Price) Bid. We agree that the rates and prices to be quoted in Second Stage Bid shall be deemed to include and account for the full scope as aforesaid, including overheads and profit.
We declare that as specified in the ITB Clause 22.5, Volume-I of the Bidding Documents, prices to be quoted by us in the Price Schedules shall be Firm basis during the entire currency of contract and shall not be subject to Price variation what-so-ever during contract execution
We confirm that except as otherwise specifically provided our Bid Prices in Second Stage Bid shall include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
100% of applicable Taxes and Duties i.e. GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
We further understand that notwithstanding 4.0 above, in case of award on us, you shall also bear and pay/reimburse to us, GST in respect of supplies by us imposed on the Plant & Equipment including Mandatory Spare Parts to be incorporated into the Facilities including Type Test charges for Type test to be conducted specified in Schedule No. 1 (of Second stage bid), Instalation Services specified in Schedule No. 3 (of Second Stage bid), Charges for Training to be imparted in India specified in Schedule-4a (of Second Stage bid) and Maintenance Charges during Defect Liability Period and Annual Maintenance Charges after Defect Liability Period Schedule-4b (of Second Stage bid) by the Indian Laws.
We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods
Construction of the Contract
We declare that we have studied GCC Sub-Clause 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us three separate Contracts for each SLDC and ERLDC viz. ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares , ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, unloading, storage, handling at site, installation, testing and commissioning including parallel Operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents and ‘Third Contract’ for Comprehensive maintenance services for one year warranty period and 6 years thereafter for the equipments and services delivered under ‘First Contract’ and ‘Second Contract’. We declare that the award of three contracts will not in any way dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that all three Contracts will have a cross-fall breach clause i.e. a breach in one contract will automatically be classified as a breach of other contracts which will confer on you the right to terminate the other Contract at our risk and cost.
@ We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us
Appendix 2 to Form of Contract Agreement
Appendix 2 to Form of Contract Agreement
We undertake, if our Second Stage Bid is accepted, to commence the work on Facilities immediately upon your Notification of Award to us, and to achieve Completion within the time stated in the Bidding Documents.
If our Second Stage Bid is accepted, we undertake to provide Advance Payment Security and a Performance Security(ies) in the form and amounts, and within the times specified in the Bidding Documents.
We further undertake, if invited to do so by you and at our own cost, to attend a clarification meeting at a place of your choice for the purposes of reviewing our First Stage Bid and duly noting all amendments and additions thereof and noting omissions there from that you may require.
We further undertake, upon receiving your written invitation, to proceed with the preparation of our Second Stage Bid, updating our First Stage Bid in accordance with the requirements from the Memorandum of the clarification meeting and completing our commercial bid for performing the Facilities in accordance with our updated technical bid.
# (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Printed Name :
Designation :
Other Partner -2
Printed Name :
Designation :
Note: Bidders may note that no prescribed proforma has been enclosed for
Three
Seven
Eight
Eleven
Twelve
Thirteen
Fourteen
Fifteen
Sixteen
Seventeen
Eighteen
Nineteen
Twenty
Twenty One
Twenty Two
Twenty Three
Twenty Four
Twenty Five
Twenty Six
Twenty Seven
Twenty Eight
Twenty Nine
Thirty
Thirty One
Thirty Two
Thirty Three
Thirty Four
Thirty Five
Thirty Six
Thirty Seven
Thirty Eight
Thirty Nine
Forty
Forty One
Forty Two
Forty Three
Forty Four
Forty Five
Forty Six
Forty Seven
Forty Eight
Forty Nine
Fifty
Fifty One
Fifty Two
Fifty Three
Fifty Four
Fifty Five
Fifty Six
Fifty Seven
Fifty Eight
Fifty Nine
Sixty
Sixty One
Sixty Two
Sixty Three
Sixty Four
Sixty Five
Sixty Six
Sixty Seven
Sixty Eight
Sixty Nine
Seventy
Seventy One
Seventy Two
Seventy Three
Seventy Four
Seventy Five
Seventy Six
Seventy Seven
Seventy Eight
Seventy Nine
Eighty
Eighty One
Eighty Two
Eighty Three
Eighty Four
Eighty Five
Eighty Six
Eighty Seven
Eighty Eight
Eighty Nine
Ninety
Ninety One
Ninety Two
Ninety Three
Ninety Four
Ninety Five
Ninety Six
Ninety Seven
Ninety Eight
Ninety Nine
One Hundred
Item Description
Unit Insurance Charges
As finalized during First Stage Biding Process
The item-wise break-down of price components for various items is required to be furnished by the bidder. For the said purpose, the item-wise break-down together with Bill of Quantities (BOQ) shall be finalised during First Stage Bid evaluation. The same shall be issued along-with invitation for Second Stage Bid to those bidders from whom Second Stage Bids are invited.
The actual quantity in Lot will be calculated based on the quantity as mentioned in specification.
Signature
Printed Name
Item Description
As finalized during First Stage Biding Process
The item-wise break-down of price components for various items is required to be furnished by the bidder. For the said purpose, the item-wise break-down together with Bill of Quantities (BOQ) shall be finalised during First Stage Bid evaluation. The same shall be issued along-with invitation for Second Stage Bid to those bidders from whom Second Stage Bids are invited.
The actual quantity in Lot will be calculated based on the quantity as mentioned in specification.
HSN stand for Harmonised System of Nomenclature and SAC stands for Service Accounting Code, used for classification of Goods for GST Purpose.
Signature
Printed Name
Description
Total Charges
As finalized during First Stage Biding Process
The item-wise break-down of price components for various items is required to be furnished by the bidder. For the said purpose, the item-wise break-down together with Bill of Quantities (BOQ) shall be finalised during First Stage Bid evaluation. The same shall be issued along-with invitation for Second Stage Bid to those bidders from whom Second Stage Bids are invited.
Signature
Printed Name
All figures are in Indian Rupees
Description
Total Charges
As finalized during First Stage Biding Process
The item-wise break-down of price components for various items is required to be furnished by the bidder. For the said purpose, the item-wise break-down together with Bill of Quantities (BOQ) shall be finalised during First Stage Bid evaluation. The same shall be issued along-with invitation for Second Stage Bid to those bidders from whom Second Stage Bids are invited.
HSN stand for Harmonised System of Nomenclature and SAC stands for Service Accounting Code, used for classification of Goods for GST Purpose.
Signature
Printed Name
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
All prices are in Indian Rupees
Description
To and fro charges and accommodation for the Instructor (Trainer) and Training material for the Trainees shall be included in the prices quoted by the bidder.
Signature
Printed Name
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
All prices are in Indian Rupees
Description
To and fro charges and accommodation for the Instructor (Trainer) and Training material for the Trainees shall be included in the prices quoted by the bidder.
Signature
Printed Name
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Description
Signature
Printed Name
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Description
Signature
Printed Name
Item Nos.
Total Customs Duty (including Basic Custom Duty, cess, levies and GST)
Total GST on if any, applicable on reverse charge basis on Marine freight which is not included in the freight charges as per the provision of the Bidding Documents. (for Items identified in Schedule 1a)
TOTAL GST on Goods
Total GST on Installation Charges (identified in Schedule 3') as per the provisions of the bidding documents
Total GST on Training Charges for Training (indentified in Schedule-4(a)), as per the provisions of the bidding documents.
Total GST on AMC charges (indentified in Schedule-4(b)), as per the provisions of the bidding documents.
GRAND TOTAL [1+2+3+4]
Signature:
Printed Name:
Description
Signature:
Printed Name:
Description
TOTAL SCHEDULE NO. 1(a)
TOTAL SCHEDULE NO. 1
TOTAL SCHEDULE NO. 2
Port handling & Custom clearance charges (applicable only for CIF supplies covered under Schedule-1a)
TOTAL SCHEDULE NO. 3
TOTAL SCHEDULE NO. 4a
TOTAL SCHEDULE NO. 4a
TOTAL SCHEDULE NO. 4b
TOTAL SCHEDULE NO. 4d
TOTAL SCHEDULE NO. 5
TOTAL SCHEDULE NO. 6
TOTAL SCHEDULE NO.7(b)
GRAND TOTAL
Signature:
Printed Name:
Description
Total Charges
Printed Name:
Designation:
Description
Total Charges
Printed Name:
Designation:
One Hundred
Three
Seven
Eight
Eleven
Twelve
Thirteen
Fourteen
Fifteen
Sixteen
Seventeen
Eighteen
Nineteen
Twenty
Twenty One
Twenty Two
Twenty Three
Twenty Four
Twenty Five
Twenty Six
Twenty Seven
Twenty Eight
Twenty Nine
Thirty
Thirty One
Thirty Two
Thirty Three
Thirty Four
Thirty Fivr
Thirty Six
Thirty Seven
Thirty Eight
Thirty Nine
Forty
Forty One
Forty Two
Forty Three
Forty Four
Forty Five
Forty Six
Forty Seven
Forty Eight
Forty Nine
Fifty
Fifty One
Fifty Two
Fifty Three
Fifty Four
Fifty Five
Fifty Six
Fifty Seven
Fifty Eight
Fifty Nine
Sixty
Sixty One
Sixty Two
Sixty Three
Sixty Four
Sixty Five
Sixty Six
Sixty Seven
Sixty Eight
Sixty Nine
Seventy
Seventy One
Seventy Two
Seventy Three
Seventy Four
Seventy Five
Seventy Six
Seventy Seven
Seventy Eight
Seventy Nine
Eighty
Eighty One
Eighty Two
Eighty Three
Eighty Four
Eighty Five
Eighty Six
Eighty Seven
Eighty Eight
Eighty Nine
Ninety
Ninety One
Ninety Two
Ninety Three
Ninety Four
Ninety Five
Ninety Six
Ninety Seven
Ninety Eight
Ninety Nine
One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Volume-II_PART_3_TS.pdf
pdf • 6.71 MB
Volume-II_PART_2_TS.pdf
pdf • 8.96 MB
Volume-II_PART_1_TS.pdf
pdf • 8.88 MB
02-Volume III_Attachment-13 First Stage.doc
doc • 0.03 MB
02-Volume III_Attachment-2_QR First Stage.doc
doc • 0.15 MB
02-Volume III_Attachment-21 First Stage_NDA.pdf
pdf • 0.66 MB
02-Volume III_Attachment-5 First Stage-extra sheet.doc
doc • 0.04 MB
02-Volume-III_Attachment-12-IP.doc
doc • 0.07 MB
02-Volume-III_Attachment-17-SAFETY PACT.docx
docx • 0.04 MB
02-Volume-III_Attachment-18_KMP Declaration.doc
doc • 0.03 MB
02-Volume-III_Attachment-19_Declaration regarding events encountered pursuant to ITB Clause 2-1.docx
docx • 0.03 MB
02-Volume-III_Attachment-20-Certification by the Bidder per DoE Order in line with ITB Clause 2-1.docx
docx • 0.02 MB
03-Volume-III_Schedule-I-Unpriced BOQ 1st_Stage.xlsx
xlsx • 0.19 MB
1a-Volume-III_First Stage Bid form and Attachments.xlsx
xlsx • 1.33 MB
01_Price Schedules_Second Stage final.xls
xls • 0.90 MB
01_Volume III_Bid Form Second Stage.doc
doc • 0.05 MB
01-01_Volume III_Attachment-4 to 11 (Second Stage).doc
doc • 0.11 MB
01-12_Volume-III_Attachment-12_Undertaking by the bidder regarding Compliance of DMI&SP policy.docx
docx • 0.02 MB
01-13_Volume-III_Attachment-13_Affidavit for self-certifictaion (Second Stage).DOCX
docx • 0.02 MB
01-14_Volume-III_Attachment-14_Certificate by Auditor (Second Stage).docx
docx • 0.02 MB
01-15_Volume-III_Attachment-15_Compliance to the process related to the e-RA (Second Stage).docx
docx • 0.02 MB
01-16_Volume-III_Attachment-16_Bid Securing Declaration.docx
docx • 0.02 MB
01_Main index Volume - I.doc
doc • 0.03 MB
02_Volume I Section I IFB.docx
docx • 0.04 MB
03_Volume I Section - II ITB Two Stage S&I Rev 2-for e-pro..docx
docx • 0.07 MB
04-Volume I _ Section - III BDS.docx
docx • 0.12 MB
05-Annexure-A (BDS).docx
docx • 0.03 MB
06-Annexure-B(BDS).docx
docx • 0.02 MB
07-Annexure-C(BDS).docx
docx • 0.03 MB
08-Annexure-D (BDS).docx
docx • 0.02 MB
09-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
10-Section-V-SCC.docx
docx • 0.06 MB
11-Appendix -I to SCC.doc
doc • 0.16 MB
12-Section VI FORMS.doc
doc • 0.56 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
Letter of Confirmation from Bidders_Rev1.doc
doc • 0.04 MB
Invitation_for_Second_Stage_Bids.docx
docx • 0.01 MB
Annexure II (Appendix G BoQ).pdf
pdf • 1.10 MB
Amendment-III.pdf
pdf • 0.29 MB
OBD_extension.doc
doc • 0.03 MB
Amendment No-II.pdf
pdf • 0.12 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
Clarification No-II_Part-2.pdf
pdf • 0.38 MB
Clarification-_1.pdf
pdf • 0.78 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
OBD_EXTENSION_NOTICE.docx
docx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .