Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.9 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹17.3 L+₹98,204.55 (6.00%)Rejected-AOC | 2 | Rejected-AOC NOT L1 BIDDER | |
| 3 | 3₹20.2 L+₹3.9 L (23.6%)Rejected-AOC | 3 | Rejected-AOC NOT L1 BIDDER | |
| 4 | 4₹20.4 L+₹4.0 L (24.7%)Rejected-AOC 35 P C MUKHERJEE STREET PO KONNAGAR DIST HOOGHLY PIN 712235 | KONNAGAR | HOOGHLY | WEST BENGAL | 712235 | 4 | Rejected-AOC NOT L1 BIDDER | |
| 5 | 5₹21.3 L+₹4.9 L (30.0%)Rejected-AOC | 5 | Rejected-AOC NOT L1 BIDDER |
Tender Value
₹14.5 L
EMD Value
₹28,980
Closing Date
5 Mar 2024, 4:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
REPAIR MAINTENANCE OF TILING JOINERY PLUMBING AND CERTAIN BR ALLIED WORKS AT DS CELL ICHAPORE UNDER GE (NORTH) KOLKATA
2024_MES_641154_1
8322/23-24/GE(N)/KOL/E8 of 2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
ISHAPORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹28,980
Yes
14 Mar 2024
7 Feb 2024
6 Mar 2024
8 Feb 2024
5 Mar 2024
20 Feb 2024
Amount
Taking down and re-fixing of shutter after easing and necessary cutting of any description in same opening area exc 1 sq.m and n exc 2 sq.m each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off premises complete all as specified and directed.
Demolition of concrete in ground floor & paving not exc. 15 cm thick (above or below GL) complete all as specified and directed.
M&L for 40mm thick cement concrete (1:2:4) type B2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15 mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade / colour / matrix of the tiles complete all as specified and directed.
Material and labour for light shade vitrified tiles not less than 8.50 mm thick with double charge (square/rectangular) polished, area of each tiles exc 0.18 sqm and n exc 0.38 of each tile in floor set and jointed in neat cement slurry & pointed in white cement and pigment to match the colour of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete as specified and directed.
Material and labour for light shade vitrified tiles not less than 8.50 mm thick with double charge (square/rectangular) polished, area of each tiles exc 0.18 sqm and n exc 0.38 of each tile as in skirting/ dado laid over 10mm thick rendering of mortar in CM (1:4) complete all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade/ colour/ matrix of the tiles complete all as specified and directed.
Supply and applying a glass fibre reinforced acrylic modified cementitious coating system including prepration of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as Top coat: SikaTop Seal-107 @ 1.5 kg/m2 over reinforcement: Sika Fab-1 over base coat: SikaTop Seal-107 @ 1.5 kg/m2 etc including Supply and apply a protection plaster (12 – 15 mm) admixed with appropriate integral waterproofing compound Sika Plastocrete Plus @0.10 kg per bag of cement. The product should conform to IS 2645, system should have compressive strength : 20 N/mm2; bond strength : 2.0 N/mm2 complete all as specified and directed.
Dismantling of stone slabs and tiles, laid bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed.
M&L for 50 mm thick sand filling under floors or in foundation including watering & consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size with grey cement & pigment conforming to IS 15658- 2006 of 60 mm thickness, M-35 Grade & polishing complete all as specified and directed.
Removing of plants & shrubs girth not less than 3 cm including roots by dismentling of brick work, PCC/ RCC work including necessary scaffolding any type in any location/ position (i.e) roof, parapet wall, near pipes etc. after removal of roots, trees, scrubs etc from any location of wall and making good to the disturbed portion using PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) and 10mm thick plaster in CM (1:3) including applying acid after removing roots for preventing the regrowth complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces of ceiling and finishing the surfaces even & smooth without using extra cement etc. complete all as specified and directed.
M&L for 15mm thick rendering on concrete/ brick surface in cement mortar (1:4) surface finished even and smoooth without using extra cement and using liquid WPC complete all as specified and directed. (Note : WPC shall be measured and paid separately).
M&L for preparation of newly plastered surfaces of wall with one coat of alkali resistant primer, and applying two coats of anti fungal paint (weather coat) white or coloured by using roller, including necessary scaffoldings up to 2th storey height of building complete all as specified and directed as per manufacturers instructions complete all as specified and directed.
M&L for complete removal of existing treatment from old decorated plastered surfaces of wall by suitable sanding machine, removal of nail etc. & filling cracks/hole with putty, and applying two coats of anti fungal paint (weather coat) white or coloured by using roller over one coat of alkali registant primer, including necessary scaffoldings upto 2nd storey height building complete all as specified and directed as per manufacturers instructions etc. complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Taking down existing aluminium door and carrying out all necessary repair work including tightening, adjusting and replacement of hinges, screw, aluminium tower bolt and refixing in the same/ modified opening complete all as specified and directed.
S&F in repair for door closer, aluminium (extruted section body), hydraulically regulated, designation No, 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
M&L for applying two coats of oil bound distemper by using roller over a coat of primer over a coat of sanded prepared surface of wall care putty not less than 1mm thick, over prepared wall surface (After complete removal of existing treatement surface) prepared with sanding machine by using mechanical means as per manufacturers instructions complete all as specified and directed.
S&F 18 mm thick medium density fibre board (MDF), Pre-laminated exterior grade both side laminated board fixed to frame as in shutters to cupboards including suitable 2 mm thick lipping / beading all round shutters complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth and applying with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surface not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down door/ window frame with shutter (without taking of shutter from the frame) area not exc 1.5 sqm complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, with wood free EPS 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain coloured PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F 125 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 125 mm long aluminium anodised handle cast type and fixed complete all as specified and directed.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for the frame doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings complete all as specified and directed.
S&F 5mm thick sheet glass, ordinary quality in square but exceeding 0.5 sqm in each panel for aluminium frame complete all as specified and directed.
S&F 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed aluminium frame complete all as specified and directed.
Dismantling of Wall boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick Wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
S&F steel window with side hung shutters including projecting or box style hinges with steel handle peg stay and divided into square with glazing bars dovetailed or welded, to receive glazing, or gauzing including one coat of primer including etc all complete all as specified and directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe. 290 Gde-E-165 complete all as specified and directed.
Dismanting wrought iron or mild steel work of any description not otherwise provided for etc. complete all as specified and directed.
S & F 3.0mm thick figured glass pin headed type and glazing with oil putty in squares n exc 0.5sqm in each pane complete all as specified and directed.
Demolition of boundary wall of brick work built in cement mortar including all quions arches, pillar etc. but excluding ashalar facing dressed stone and pre-cast concrete articles complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Fixing only serviceable bricks obtained from Item No. 42 here-in-before in CM (1:6) complete all as specified and directed.
Excavation in trenches for soft/lose soil n.exc 1.5 m wide and n.exc 1.5m depth for foundation complete all as specified and directed.
Retuning filling including spreading, leveling, watering and ramming in layers n.exc 25 mm thick complete all as specified and directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (design mix) M25 using 20mm graded stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. complete all as specified and directed. Note: Reinforcement and formwork shall be measured and paid separately.
M&L for reinforced cement concrete (design mix) M25 using 20mm graded stone aggregate in columns, pillars, piers, posts and struts etc. complete all as specified and directed. Note: Reinforcement and formwork shall be measured and paid separately.
M&L for reinforced cement concrete (design mix) M25 using 20mm graded stone aggregate in Beams, cantilevers, bressummers, lintels etc. complete all as specified and directed. Note: Reinforcement and formwork shall be measured and paid separately.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for TMT bars 10mm dia and over upto and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No. 55 above but 6mm to 8mm dia TMT bars complete all as specified and directed.
S&F in repair galvanized, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia, barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel pins etc. complete all as specified and directed.
Dismantling of MS "Y" section from old boundary walls and re-fixing in new boundary wall complete all as specifed and directed.
M&L for cement concrete (1:2:4) type B1 (using 20 mm graded aggregates) as in copings rounded or chamfered on edges etc including necessary formwork complete all as specified and directed.
S&F in repair GI tubing 15mm bore medium grade with all fittings and fixed to wall complete all as specified and directed.
S&F in repair GI tubing 20mm bore medium grade with all fitting and fixed to wall complete all as specified and directed.
S&F in repair bib tap 15mm bore fancy type chromium plated with capstan head screwed down for iron pipe or for brass ferrule fixed to iron pipe etc complete all as specified and directed.
S&F in repair stop cock/ angle cock 15mm bore fancy type chromium plated with capstan head high pressure screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed.
S&F in repair pillar tap 15mm dia fancy type cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shank and fly nuts, screwed for iron pipe and fixed Cat no of Essco-APR-101001M, Parryware-T4601A1 & Hindware-F360001 complete all as specified and directed.
S&F in repair Vitreous China wash basin, white, flat back, size( 550X400) mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, 32mm dia CP waste coupling and 32mm dia flexible waste pipe and PVC Connection 15mm size with PTMT nuts of length 450mm & with suitable padestel type complete all as specified and directed.
S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern' size (580 x 440) mm white with integral foot rests (excluding flushing cistern), including flush pipe of polyethylene of low or high density, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete trap set in concrete and including 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed.
S&F in repair 10 Ltrs capacity PVC low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed.
S&F PVC (SWR) floor trap, 110 mm outlet dia, plain with CP grating incl jointing with solvent cement complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socked in any length with rubber ring joints fixed to wall including taking out old broken/ unserviceable pipe of any description including fittings complete all as specified and directed.
S&F PVC (SWR) 110 mm bore bends of any radius complete all as specified and directed.
S&F 40mm dia high density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm etc complete all as specified and directed.
S&F stack clamps made out of (25x 3) mm thick flat iron made to shape as directed including plug and screws for securing ends of stay to walls for sanitary pipe for 75/100 mm bore dia of pipe including taking down old clamps etc complete all as specified and directed.
S&F chromium plated gratings size 75/100 mm with waste hole complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
M&L for anti termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300 mm intervals including drilling holes at 45 degree and replugging them with CM (1:2) to match the existing floors etc. complete all as specified and directed.
Material and labour for cleaning and removing all scale,dirt and fungas etc. from tanks and mouth of circulating pipes, with suitable cleaning chemical and brushing the wall and bottom of tanks, washing with clean water, writing letter i.e. "TANK CLEANED ON ......................(Date)" not exc. 100mm height with synthetic enamel paint for tanks of capacity 250 ltrs to 500 ltrs complete all as specified and directed.
S & F in repair rotational moulded polyethylene water storage tanks (multi layered) 500 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed including Ball brass valves 25 mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair Ball brass valves 25 mm, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.45 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 100mm thick cement concrete (1:2:4) type- B2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
Supply and install hi wall split units indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified and directed.
Supply and fix automatic voltage stablizer single phase 220 volt 50 Hz of capacity 5 KVA complete all as specified and directed.
Supply, installation, commissioning of water cooler partially stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs complete all as specified and directed.
S&F in repair for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside serviceable materials for reuse including making good of the disturbed surfaces, complete all as specified and directed.
Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLSH unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC casing-N- caping (medium duty) double lock type,size of casing caping as required at site but not less than 20mm with fittings and accessories pressed steel sunken terminal box in concealed made out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light point controlled by one, one way 5 Amp switch complete all as specified and as directed.
All as per Item No. 89 above but for One fan point controlled by one, one way 5 Amp switch complete all as specified and as directed.
All as per Item No. 89 above but for one 5 pin socket outlet 5 Amp on independent board complete all as specified and as directed.
All as per Item No. 89 above but for one 5 pin socket outlet 05 Amp on same board complete all as specified and as directed.
All as per Item No. 89 above but for one bell/ buzzer point controlled by one push button same board with other switch or independent complete all as specified and as directed.
All as per item No 89 above but for one 15 Amps socket outlet using 2.5 sq mm, copper conductor with 1.5 sq mm, PVC insulated single core cable for earth continuity conductor complete all as specified and directed.
M&L for concealed point wiring complete with 1.5 sq mm FRLSH, PVC insulated multi standard copper conductor single core cable 1100 volts grade,drawn into non metalic PVC rigid conduit medium grade of size not less than 20mm bore and conduit accessories fixed on wall roof etc, and including provn of PVC insulated 1.5 sq mm copper conductor cable for each continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6 mm thick MS sheet concealed in wall and laminated sheet cover of 3 mm thick on top for housing the switches socket,outlet etc., for one light point controled by one, one way 5 Amp switch complete all as specified and directed. Note :- PVC conduit, making good to disturbed wall surfaces including finishing with cement mortar (1:4) matching with existing shade of the painted surface are deemed to be included in the quoted rate.
All as per item No 95 above but for One fan point controlled by one, one way 5 Amp switch complete all as specified and directed.
All as per item No 95 above but for One 5 pin socket outlet 05 Amp on independent board complete all as specified and directed.
All as per item No 95 above but for One 5 pin socket outlet 05 Amp on same board complete all as specified and directed.
All as per item No 95 above but for One bell/ buzzer point controlled by one push button same board with other switch or independent complete all as specified and directed.
All as per item No 95 here-in-before,for one 15 Amps socket outlet but using 2.5 sq mm,copper conductor with 1.5 sq mm,PVC insulated single core cable for earth continuity conductor complete all as specified and directed.
Supply and fix switch piano flush button 6 Amp single pole, one way complete all as specified and as directed.
Supply and fix socket outlet 5 Pin, 6 Amps flush type complete all as specified and as directed.
Supply and fix Switch socket combination 5 Pin, 6 Amp flush type complete all as specified and as directed.
Supply and fix switch socket combination 5 Pin 15/16 Amp flush type with complete all as specified and as directed.
Supply and fix lamp holder insulated body with back plate for angle/ batten fittings complete all as specified and directed.
Supply and fix ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and directed.
Supply and fix bell push, flush type, 6 Amps complete all as specified and directed.
Supply and fix electronic fan regulator stepped type flush type AC 240 volt complete all as specified and as directed.
Supply and fix in repair call bell Ding Dong, AC, 230V single pole complete all as specified and directed.
S&F white cover plate with frame, 2 module complete all as specified and directed.
Supply & fix Modular socket, 6A-2/3 pin combined 2 Module complete all as specified and directed.
Supply & fix Modular socket, 6A/16A-2/3 pin combined 2 Module complete all as specified and directed.
M&L for sub-main wiring (concealed type) with two run of PVC insulated, unsheathed, FRLS single core, multistranded copper conductors of size 4.0 Sq mm and one run of 4.0 Sqmm copper conductor as continuity earth wire, drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site and taking down old sub main wiring with conduit complete all as specified and directed. Note:- (i):Two run of 4.0 sqmm and one run of 4.0 sqmm copper conductor ( for Phase, Neutral and Earth) + One run of PVC conduit shall measured as one unit).
S&F LED tube light fitting, 1 x 18 watt bipin holders, connector block etc. complete and connecting the same to ceiling rose with using copper conductor 23/0.0076 flexible twisted twin core cable ,and fixing the light fitting to walls / roof complete all as specified & directed
Supply and fix in repair powder coated sheet metal enclosure (in concealed) single pole & neutral for DBs (Double door) 8 way, 240 V with 200 amps rated busbar DIN channel, neutral link & earth link superline complete all as specified as directed. Note: (Chase cutting & make good to disturbed surface is deemed to be included in quoted rate)
Supply and fix in repair MCB single pole & neutral/ Double Pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed
Supply and fix in repair MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified and directed.
M&L for cutting hard standing / road for laying of pipe, not exc 30 cms wide and not exc 30 cms deep, and getting out in soft/loose soil, etc complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) not exc 30 cm wide and not exc 30 cm deep for filling and making good to disturbed surfaces of road/ hardstanding etc. complete all as specified and directed.
Taking out from trenches or taking down from wall GI steel tubing and connections, 25 mm bore, setting aside and cleaning the serviceable pipe for re-laying/ re-fixing or removal of unserviceable pipe from site of work complete all as specified and directed.
S&F 20 mm bore GI tubing, medium grade with all new fittings as required fixed to walls and ceilings or laid in floors/ trenches including testing complete all as specified and directed.
All as per item No 121 above but for 25 mm bore of pipe complete all as specified and directed.
M&L for Minor leakage rectification work of water supply line for GI pipe of size ranging from 15 to 25 mm complete within 4-6 hrs. of raised complaint complete all as specified and directed.
Supply and fix 20mm bore gun-metal, gate valves, with iron wheel head, screwed both ends for iron pipe and fixed after taking down old unserviceable one complete all as specified and directed.
All as per item No. 124 above but 25 mm bore gun-metal gate valve complete all as specified and directed.
Taking down carefully ceiling fans of any make, model and capacity from their existing places for replacement of bush, bearing, capacitor, servicing (i.e) lubricating / greasing and for rewinding/ painting by dismantling the same and keep the blades, canopy, split pin and other parts and components in safe custody and hanging / fitting on previous position after repair/ rewinding/ painting/ replacement of spares etc. complete all as specified and directed. Note:- i) The unit rate quoted is deemed to include for the labour element involved in replacing the spares. (ii) The spares replaced shall be measured and paid as supply only items herein below. (iii) The spares shall suit the exisiting makes of fans or as per existing make of spares, as approved by the GE. (iv) Rewinding and painting shall be measured and paid separately. Existing makes :- Bajaj, Khaitan, Usha, Himadri
All as per item No. 126 above but for Exhaust Fans complete all as specified and directed.
All as per item No. 126 above but for Air Circulators wall mounted Fan complete all as specified and directed.
All as per item No. 126 above but for floor mounted pedestal fan complete all as specified and directed.
Supply only GM Bush for ceiling fan 1200/1400 mm sweep/ Exhaust Fan 230/300/350/450 mm sweep/or any type fan complete all as specified and directed.
Supply only Ball bearing (CAT No. 6201) for ceiling Fan/ Exhaust Fan / or any type fan complete all as specified and directed.
All as per item No. 131 above but ball bearing CAT No. 6202 complete all as specified and directed.
All as per item No. 131 above but for ball bearing CAT No. 6203 complete all as specified and directed.
Supply only capacitor 2.5 mfd, 220 volts complete all as specified and directed. Make:Tipcon / Universal / Sarda / Usha. / C&S).
All as per item No. 134 above but of capacity 3.0/4.0 mfd complete all as specified and directed.
Supply and fix in repair louver shutter 300 mm sweep exhaust fan, of existing make, made of MS sheet folded type complete all as specified and directed.
All as per item No 136 above but 450 mm sweep exhaust fan complete all as specified and directed.
Material and labour for painting by spraying with synthetic enamel paint to Ceiling Fans / Exhaust Fans/ Air Circulators wall mounted Fans/Floor mounted pedestal Fans including Blades/Down rods/ Canopy/Stand, Casing/ Cage and all accessories after preparation of surface including thoroughly rubbing /cleaning old rusted spot complete all as specified and as directed. Make of paint:- Asian / Berger / Jenson & Nicholson / Shalimar.
Material and labour for Rewinding of ceiling fans armature of 1200 mm /1400 mm sweep of any make & Model with replacing the burnt out winding by new super enameled high grade copper wire of existing gauge and number of turns and all insulating materials including heat varnishing and testing complete all as specified and directed.
All as per item No.139 above but for exhaust fan 230mm/ 300mm sweep, single phase, 230 volts complete all as specified and directed.
All as per item No. 139 above but for exhaust fan 450 mm sweep, three phase, 230 volts complete all as specified and directed.
Supply and fix in repair fan blades for exhaust fan of 300 mm sweep as per existing make and type complete all as specified and directed.
All as per item No. 142 above but for exhaust fan of 450 mm sweep complete all as specified and directed.
Material and labour for lathe work for worn out spindle of ceilling fan/ Exhaust Fan/ Air Circulators/ Wall mounting Fan of any sweep, make & Model with replacing the worn out spindle by new one of existing size and materials including testing for free motion of fans complete all as specified and directed.
Material and labour in replacement of incoming twin core copper flexible wire ( not more than 45cm) of size 14/0.0076 from ceiling rose to ceiling fan / exhaust fans complete all as specified and directed.
Supply and fix in repair 3 pin plug top 6 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in repair 3 pin plug top 16 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed.
Supply and fix in repair 2.5 Mfd fan capacitor, 220V complete all as specified and directed.
SHARMA CONSTRUCTION
PUJA ELECTRICALS
M/S MAHENDRALALL DUTTA
RUNJEN CONSTRUCTION
MASTER BUILDERS
MOTHER LUMIER INDUSTRIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .