CEO ZP THANE
CEO Office Z P Thane
M and R TO VAJRESHWARI R.R.W.S. SCHEME Tal.Bhiwandi Dist. Thane
2026_THANE_1308019_1
E-TENDER NOTICE NO 07/EE/RWSD/ZPTHANE/2025-26POEN 3rd Call
Open Tender
Electrical and Maintenance Works
Percentage
Bhiwandi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹28,200
31 Aug 2026
11 Jun 2026
15 Jun 2026
11 Jun 2026
14 Jun 2026
11 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour salaries to paid to M&R staff for operating and repairing Pise Dhamangav R.R.Water Supply Scheme Tal. Bhiwandi and making water supply to all villages without interruption as far as possible as per terms & conditions as well as sallent features of work to be maintained operuted & repairs.1) Pump operator/Driver- 3 Nos. with daily rate Rs. 641/- 2) Ass. Fitter- 4 Nos. with daily rate Rs. 641/- 3) Helper- 2 Nos with daily rate Rs. 622/-, Total Monthly Amount Rs. 114240/- Total Yearly Amount Rs. 1370880/- | 1 | One Number | 13,70,880 | ₹13,70,880 |
| 2 | PART- ACurrent Repairing to existing pumping machinary of raw water and pure water pump 10 HP 2 No and 15,20 HP including all necessary repairing.Daily maintenance of existing motor pump at Regional Water Supply Scheme. In case of malfunction of motor and panel, repairing and restarting water supply from time to time, maintaining necessary power plant, adopting electrical deadlock and anti-static, less electricity should be used, employing trained pump operator to handle motor pump, informing the department in case of malfunction of motor pump and repair. Repair orders should be recorded and a pump logbook should be maintained. Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR/MCBCOS | 2 | One Number | 3,255 | ₹6,510 |
| 3 | Supplying and erecting iron clad cut out HC type 415V 200A erected on polished wooden block complete. | 9 | One Number | 1,259 | ₹11,331 |
| 4 | Supplying & erecting HRC fuse cartridge 415V 200A complete. | 6 | One Number | 295 | ₹1,770 |
| 5 | Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq. mm. cable, with necessary material as per specification no. CB-JT/LT | 4 | One Number | 2,229 | ₹8,916 |
| 6 | Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU | 16 | One Number | 58 | ₹928 |
| 7 | Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA | 2 | One Number | 15,734 | ₹31,468 |
| 8 | Supplying & replacing contactor for Star Delta motor starter from 12.5 H.P. to
15 H.P. | 2 | One Number | 1,083 | ₹2,166 |
| 9 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined ammeter/voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proof
enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc. | 1 | One Number | 7,461 | ₹7,461 |
| 10 | Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C.Submersible/centrifugal pump set up to 20 HP consisting of Star Delta starter having relay range 28-42 Amp, S.P.P., Combined ammeter/ voltmeter,phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc . | 1 | One Number | 18,375 | ₹18,375 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.46 MB
BOQ_2244342.xls
BOQ • 0.30 MB
TENDERDOCUMENTmerged.pdf
Tender Documents • 1.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .