| Sl No | Description | Qty | Unit | ELECTRO TRADING CO. L1 | ROY CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00Testing of Electrical Equipment such as Transformer, Switch Gear and HT Induction motor of Khottadih Colliery Under Pandaveswar Area. (Inclusive of EPF/CMPF) | |||||
| 1.01 | Cost of testing by Megger insulation tester of following Transformer :-
a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No.
c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No. h) 1600 KVA, 6.6KV/1100V TSU- 2 Nos. i) 315 KVA, 6.6KV/550V TSU- 18 Nos. j) 500 KVA, 6.6KV/550V TSU- 1 No. | 30 | Nos | 2,000 ₹60,000 | 5,800 ₹1,74,000 |
| 1.02 | Cost of testing by High Voltage Pressure Test of following Transformer :-
a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No.
c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No. h) 1600 KVA, 6.6KV/1100V TSU- 2 Nos. i) 315 KVA, 6.6KV/550V TSU- 18 Nos. j) 500 KVA, 6.6KV/550V TSU- 1 No. | 30 | Nos | 5,200 ₹1,56,000 | 5,800 ₹1,74,000 |
| 1.03 | Cost of testing of Transformer oil by dissolved gas analysis Test, Acidity Test, Di-electric Test, Water content measurement slag contest of following Transformer :-
a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No.
c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No. | 9 | Nos | 18,000 ₹1,62,000 | 5,800 ₹52,200 |
| 1.04 | Cost of testing by Megger insulation testing of following Switch gear:-
a) 6.6KV V.C.B. - 82 Nos. b) 11KV V.C.B.- 4 Nos. c) 33 KV MOCB.- 3 Nos.
d) 33KV SF6 Breaker- 1 No. e) 6.6KV Capacitor Bank- 1 No. f) 6.6KV Starter-17 Nos. | 108 | Nos | 2,000 ₹2,16,000 | 5,800 ₹6,26,400 |
| 1.05 | Cost of testing by high voltage pressure testing of following Switch gear:-
a) 6.6KV V.C.B. - 82 Nos. b) 11KV V.C.B.- 4 Nos. c) 33 KV MOCB.- 3 Nos.
d) 33KV SF6 Breaker- 1 No. e) 6.6KV Capacitor Bank- 1 No. f) 6.6KV Starter-17 Nos | 108 | Nos | 5,200 ₹5,61,600 | 5,800 ₹6,26,400 |
| 1.06 | Cost of Testing of Current Transformer (C.T.) by Primary current Injection Test set. | 108 | Nos | 4,200 ₹4,53,600 | 5,850 ₹6,31,800 |
| 1.07 | Cost of repairing, testing & calibration of Earth leakage relay by secondary current Injection Test Set including supply of necessary spares in place of damaged spares. | 108 | Nos | 4,800 ₹5,18,400 | 2,100 ₹2,26,800 |
| 1.08 | Cost of testing by Megger insulation testing of following Motors:-
a) 190KW 6.6KV Induction Motor.- 3 Nos.
b) 150KW, 6.6KV Induction Motor- 10 Nos.
c) 140KW, 6.6KV Induction Motor-1 No.
d) 225KW, 6.6KV Induction Motor- 3 Nos.
e) 365KW, 6.6KV Induction Motor – 2 Nos.
f) 300KW, 6.6KV Induction Motor – 2 Nos.
g) 90KW, 6.6KV Induction Motor – 1 No.
h) 250KW, 6.6KV Induction Motor – 1 No.
i) 420KW, 6.6KV Induction Motor -1 No. | 24 | Nos | 2,000 ₹48,000 | 5,800 ₹1,39,200 |
| 1.09 | Cost of testing by high voltage pressure testing of following Motors:-
a) 190KW 6.6KV Induction Motor.- 3 Nos.
b) 150KW, 6.6KV Induction Motor- 10 Nos.
c) 140KW, 6.6KV Induction Motor-1 No.
d) 225KW, 6.6KV Induction Motor- 3 Nos.
e) 365KW, 6.6KV Induction Motor – 2 Nos.
f) 300KW, 6.6KV Induction Motor – 2 Nos.
g) 90KW, 6.6KV Induction Motor – 1 No.
h) 250KW, 6.6KV Induction Motor – 1 No.
i) 420KW, 6.6KV Induction Motor -1 No. | 24 | Nos | 5,200 ₹1,24,800 | 5,800 ₹1,39,200 |
Tender Value
₹41.5 L
EMD Value
₹51,900
Closing Date
9 Jan 2026, 6:00 pmClosed
Area Engineer(E and M)
Office of the General Manager Pandaveswar Area , P.O. Pandaveswar, Dist.-Paschim Bardhaman, West Bengal-713346
Testing of Electrical Equipment such as Transformer, Switch Gear and HT Induction motor of Khottadih Colliery Under Pandaveswar Area
2025_ECL_350305_1
GM-PND/EandM/25-26/233/1196 dated 27/12/2025
Open Tender
Electrical and Maintenance Works
30 days
Khottadih Colliery
Please refer Tender documents.
5 documents required · 5 mandatory
₹51,900
9 Mar 2026
30 Dec 2025
10 Jan 2026
30 Dec 2025
9 Jan 2026
30 Dec 2025
30 Dec 2025 - 2 Jan 2026
Amount
Testing of Electrical Equipment such as Transformer, Switch Gear and HT Induction motor of Khottadih Colliery Under Pandaveswar Area. (Inclusive of EPF/CMPF)
Cost of testing by Megger insulation tester of following Transformer :- a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No. c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No. h) 1600 KVA, 6.6KV/1100V TSU- 2 Nos. i) 315 KVA, 6.6KV/550V TSU- 18 Nos. j) 500 KVA, 6.6KV/550V TSU- 1 No.
Cost of testing by High Voltage Pressure Test of following Transformer :- a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No. c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No. h) 1600 KVA, 6.6KV/1100V TSU- 2 Nos. i) 315 KVA, 6.6KV/550V TSU- 18 Nos. j) 500 KVA, 6.6KV/550V TSU- 1 No.
Cost of testing of Transformer oil by dissolved gas analysis Test, Acidity Test, Di-electric Test, Water content measurement slag contest of following Transformer :- a) 5 MVA, 6.6KV/3.3KV- 3 Nos. b) 5 MVA, 6.6KV/11KV- 1 No. c) 2 MVA, 6.6KV/11KV- 1 No. d) 500 KVA, 11KV/550V- 1 No. e) 100 KVA, 11KV/440V – 1 No. f) 250 KVA, 6.6KV/440V- 1 No. g) 100KVA, 6.6KV/433V- 1 No.
Cost of testing by Megger insulation testing of following Switch gear:- a) 6.6KV V.C.B. - 82 Nos. b) 11KV V.C.B.- 4 Nos. c) 33 KV MOCB.- 3 Nos. d) 33KV SF6 Breaker- 1 No. e) 6.6KV Capacitor Bank- 1 No. f) 6.6KV Starter-17 Nos.
Cost of testing by high voltage pressure testing of following Switch gear:- a) 6.6KV V.C.B. - 82 Nos. b) 11KV V.C.B.- 4 Nos. c) 33 KV MOCB.- 3 Nos. d) 33KV SF6 Breaker- 1 No. e) 6.6KV Capacitor Bank- 1 No. f) 6.6KV Starter-17 Nos
Cost of Testing of Current Transformer (C.T.) by Primary current Injection Test set.
Cost of repairing, testing & calibration of Earth leakage relay by secondary current Injection Test Set including supply of necessary spares in place of damaged spares.
Cost of testing by Megger insulation testing of following Motors:- a) 190KW 6.6KV Induction Motor.- 3 Nos. b) 150KW, 6.6KV Induction Motor- 10 Nos. c) 140KW, 6.6KV Induction Motor-1 No. d) 225KW, 6.6KV Induction Motor- 3 Nos. e) 365KW, 6.6KV Induction Motor – 2 Nos. f) 300KW, 6.6KV Induction Motor – 2 Nos. g) 90KW, 6.6KV Induction Motor – 1 No. h) 250KW, 6.6KV Induction Motor – 1 No. i) 420KW, 6.6KV Induction Motor -1 No.
Cost of testing by high voltage pressure testing of following Motors:- a) 190KW 6.6KV Induction Motor.- 3 Nos. b) 150KW, 6.6KV Induction Motor- 10 Nos. c) 140KW, 6.6KV Induction Motor-1 No. d) 225KW, 6.6KV Induction Motor- 3 Nos. e) 365KW, 6.6KV Induction Motor – 2 Nos. f) 300KW, 6.6KV Induction Motor – 2 Nos. g) 90KW, 6.6KV Induction Motor – 1 No. h) 250KW, 6.6KV Induction Motor – 1 No. i) 420KW, 6.6KV Induction Motor -1 No.
Supply of New Transformer Oil/Insulating oil for Top up in Transformers, & Current Transformers etc to maintain its required oil level.
Overhead & Profit @ 10%
Cost of both side Transportation with handling & loading & unloading charges
Total impact of GST for the purpose of CTC
ROY CONSTRUCTIONS (BID ID -1208647)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.45 MB
BOQ_363055.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid