Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Techno commercially qualified |
| 2 | Accepted-Technical | Accepted-Technical Techno commercially qualified |
| 3 | Accepted-Technical | Accepted-Technical Techno commercially qualified |
| 4 | Accepted-Technical | Accepted-Technical Techno commercially qualified |
Tender Value
₹8.4 L
EMD Value
₹16,800
Closing Date
18 Feb 2026, 1:00 pmClosed
REGISTRAR
JADAVPUR UNIVERSITY MAIN CAMPUS
Thorough renovation for making Smart Factory Lab at Ground Floor of Production Engineering Department, Jadavpur University Main Campus.
2026_JU_1001875_1
JU/e-Tender/C/62/25-26
Open Tender
CIVIL WORKS
Percentage
60 days
JADAVPUR UNIVERSITY MAIN CAMPUS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹16,800
Yes
25 Feb 2026
10 Feb 2026
20 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
Stripping off worn out plaster and raking …… the compound as directed. PCS [Item B 10 ] Page 11
Plaster (to wall ,floor, ceiling etc.) with sand cement …. where necessary (ground floor) with 4:1 cement mortar, 20 mm thick PCS [Item I 2 (ii)(a) ] Page 50 of 3rd Corrigenda
Removal of rubbish, earth, etc. from the working site …. .as per direction of the EIC PCS [Item B 13 ] Page 12
Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing ... in proportion (1 liquid: 4 cementitious material) ... in water tank etc. PCS [Item C (C) 8 (b) ] Page 45
Welding in M.S. structural work with gas or electric:Tack Weld PCS [Item F B 2 (a) ] Page 111
Hire & labour charges for shuttering …. completion of work.above 30 mm & upto 37 mm thick wooden shuttering ..… EIC. PCS [ Item C 36 (b) ] Page 42
Reinforcement for reinforced concrete work in all sorts of structures … as per drawing and direction.For works in foundation ….. upto 4m, Tor steel/ mild steel PCS [ Item C 40 (a) (i) (III)] Page 2 of 2nd Corrigenda
Labour for Chipping of concrete surface before taking up Plastering work. PCS [Item I B 1 ] Page 192
Brick work with 1st class bricks …(6:1) In superstructure, ground floor PCS [ Item C A 8 ] Page 2 of 3rd Corrigenda
Ordinary cement concrete M 20 ( mix 1:1.5:3)...….as per I.S 456 - 2000 Pakur/ Chandil variety PCS [ Item C A 7 Page 10 of 3rd Corrigenda ]
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) ... and direction of EIC. With polymerised adhesive…including spacer 2 mmDeep Colour & White PCS [Item D 36] Page 66
Rendering the surface of walls and ceiling with white cement based wall putty... (thickness not less than 1.5 mm.) PCS [Item K 5 (b) ]
Applying exterior grade Acrylic Primer of approved quality…manufacturer's specification and as per direction of the EIC One coat, Water based interior grade acrylic primer PCS [Item J 8 (a) ] Page 196
Protective and decorative acrylic exterior emulsion paint ……… all incidental charges but excluding the cost of primerPremium 100% Acrylic Emulsion PCS [Item J 17 (a) ] Page 197
Repairing steel shutter with new rivets including taking out and refixing, adjusting, welding, cleaning cutting holes,mending good damage to match with the existing one. PCS [Item F 22 ] Page 113
Renewing M.S. members of steel shutters by weldingincluding taking out the old,mending good damages complete, including taking out and refixing the glass panes PCS [Item F 22 ] Page 113
Priming one coat on timber ….sand papering etc. PCS [Item K 1 (b) ] Page 200
Priming one coat on steel or other….sand papering etc. PCS [Item K 1 (a) ] Page 200
Painting with best quality synthetic enamel paint …. surface where necessary.Two coats ( with any shade except white) With super gloss (Hi-gloss) On timber or plastered surface….other than white PCS [Item K 2 (A) ] Page 200
On steel or other metal surface…other than white PCS [Item K 2 (A) ] Page 200
Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections ... all complete as per architectural drawings and direction of EIC 10-12 Micron thickness Annodizing film Natural white PCS [Item R 15 ] Page 245
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of allaluminium sections …. direction of EIC. 10-12 Micron thickness Annodizing film Natural white PCS [Item R 16 ] Page 246
Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections ... complete as per architectural drawings and direction of EIC. 10-12 Micron thickness Annodizing film. Natural white.Unsupported length of vertical member more than 1.50 m PCS [Item R 17 (b) ] Page 247
Providing, fitting and fixing in position, medium density fibre board …. approved make and brand as per direction of EIC Plain, Interior Grade, 6 mm thick PCS [Item G 13 (A) (b) (1) ] Page 178
Supplying, fitting and fixing in position fibre glass panes … as per IS:12866-1989 (In all floors…for external wall) 1.6 mm thick (2.5 kg / Sqm) PCS [Item L A 7 (b) ] Page 206
Extra for fixing glass panes in steel window PCS [Item L A 7 (b) ] Page 206
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 8 mm thick 8mm thick coloured / tinted / smoke glass. PCS [Item R 9 (vii) ] Page 243
Supplying and affixing optically clear polyester sun control window film .... complete in all respect as per manufacturer's specification & direction of EIC. Superior Quality. Film Thickness 2.0 mil. PCS [Item L A 8 (b) ] Page 206
P.V.C Partition: Supplying, fittingand fixing the partition, frame will be made with rectangular steel tube of size 50mm x 25mm …. complete in all respect as per direction of EIC with all labour and materials. In ground floor.. PCS [Item G G 20 ] Page 181
Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid T 2430 or …. all complete as per the drawing & directions of EIC False Ceiling (with 6mm thick Fibre Cement Designer Board) PCS [Item G F 3 (A) ] Page 158
Wood work in posts, post plates, rafter … fitted and fixed complete. (excluding the cost of …nails, screws etc.) Sal : Malayasian PCS [Item G C 1 (a) (iii) ] Page 135
Supplying solid flush type doors of commercial quality, …... excluding the cost of hinges and other fittings in ground floor. 35 mm thick shutters (double leaf) PCS [Item G B 11 (a) ] Page 124
Supplying fitting & fixing Vertical Blinds in windows Non Schedule Item. Vide Tender No C-1(A)/07-08
Supply of Mazdoor PCS [Item B 3 ] Page 303
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
Declaration.pdf
Tender Documents • 0.39 MB
BOQ_2455417.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .