Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L1 | Accepted-Finance BEING L1. | |
| 2 | L2₹12.5 L+₹2.0 L (19.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1. | |
| 3 | L3₹13.0 L+₹2.4 L (23.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1. | |
| 4 | L4₹13.1 L+₹2.6 L (24.8%)Rejected-Finance 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | L4 | Rejected-Finance OTHER THAN L1. | |
| 5 | L5₹13.6 L+₹3.0 L (28.9%)Rejected-Finance FIRDOUS ABAD BATMALOO SRINAGAR PIN 190004 J K | SRINAGAR | SRINAGAR | J K | 190004 | L5 | Rejected-Finance OTHER THAN L1. |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
REPAIR / MAINT AND REPLACEMENT OF LT OH AND UG NETWORK AT BB CANTT SRINAGAR.
2021_MES_448936_1
864/WS-28/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
BB CANTT SRINAGAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹30,000
Yes
22 Jul 2021
5 Jun 2021
5 Jul 2021
5 Jun 2021
3 Jul 2021
19 Jun 2021
60 days
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out for foundation, laying of cables/pipes etc. in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1 above but exc 1.5 mtr and not exc 3.0 mtr in depth.
M&L for dry sand as in cushioning to under ground cable, 8cm thick before laying the cable and 15cm thick after laying the cable and stretching the cable, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Dry fine sand of best quality shall be used. (b) Punned thickness shall be measured and paid.
M&L for sub class 'B' old size brick, well burnt as covering to underground cable, laid dry, flat over the cable on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed.
Returning, filling in including spreading levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement galvanised iron pipe of 80mm bore, medium grade with all fittings for cable protection, laid under road / culvert / drain and fixed with clamps, made out of 50x6mm MS FI including nuts, bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material, complete all as specified and directed.
S&F in replacement galvanised iron pipe of 50mm bore, medium grade with all fittings for cable protection, laid under road / culvert / drain and fixed with clamps, made out of 50x6mm MS FI including nuts, bolt of appropriate size including closing of ends with soft wooden wedge duly preformed with bitumenous material, complete all as specified and directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete etc., complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in foundation, filling in, mass concrete and copings etc. including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces of steel tubular poles of 9 Mtr long (LT) and applying one coat of aluminium paint and including painting black and white strips 04 Nos (each strip of 30cm height) with synthetic enamel paint of black and white colour round the steel tubular pole alternatively from the bottom of the pole also including numbering of pole, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces of steel tubular poles of 11 Mtr long (HT) and applying one coat of aluminium paint and including painting black and white strips 04 Nos (each strip of 30cm height) with synthetic enamel paint of black and white colour round the steel tubular pole alternatively from the bottom of the pole also including numbering of pole, complete all as specified and directed by Engineer-in-Charge.
Taking up or down XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cable for reuse includng shifting or rerouting of LT/HT cable (heavy duty) with stranded aluminium conductor 1100 volts grade earthed, cross section area 120-240 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge. Notes :- Earth work and PCC work shall be meaured and paid seperately.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 volts grade earthed, cross section area 240 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade earthed, cross section area 95 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing and Commissioning of XPLE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade earthed, cross section area 16 Sqmm 4 core, complete all as specified and directed by Engineer-in-Charge.
Dismantling of PCC / steel tubular pole 9.0 or 11.0 mtr long, complete all as specified and directed by Engineer-in-Charge.
Refixing or shifting only steel tubular pole of any type (9/11 Mtrs long), complete all as specified and directed by Engineer-in-Charge. Note :- Earthwork and PCC shall be measured and paid seperately under relevant items.
Supply & Erecting in vertical position steel tubular swaged pole type 410 SP-31 (9 metre long) with 300x300x6mm mild steel base plate continuously welded to pole, finial taper, nuts, bolts and screws including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5 Mtr from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5 Mtr from ground level/coping, complete all as specified and directed.
Supply & Erecting in vertical position steel tubular swaged pole type 410 SP-55 (11.0 metre long) with 300x300x6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5 Mtr from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5 Mtr from ground level/coping, complete all as specified and directed by Engineer-in-Charge.
Supply, Fixing, Commissioning & Testing ACSR conductor of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed by Engineer-in-Charge.
Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including refixing / readjusting line spans, line separators, cross arms on poles, complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed by Engineer-in-CHarge.
S&F in replacement 1100 volts grade aluminium solid conductor cable with PVC armoured and overall PVC sheathed 6.0 Sqmm 2 core nominal cross section as in service connection, complete all as specified and directed.
S&F in replacement 1100 volts grade aluminium solid conductor cable with PVC tape armoured and overall PVC sheathed 10 Sqmm 4 core nominal cross section as in service connction, complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 16 KA breaking capacity, thermal magnetic type of capacity 63 Amps including all jointing materials like thimbles, tapes etc. complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 36 KA breaking capacity, thermal magnetic type of capacity 400 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
S&F in replacement MCCB 4 Pole, 50 KA breaking capacity, thermal magnetic type of capacity 630 Amps including all jointing materials like thimbles, tapes etc., complete all as specified and directed.
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engr-in-Charge. Note :- All required T&P shall be included in the quoted rates.
S&F in replacement street light panel (Timer) range 6 KW confirm to IS/IEC 60947-4-1 including internal wiring in built short circuit protection astronomical type 40 Amps MCB with IP-54, complete all as specified and directed.
S&F in replacement street light panel range 12 KW confirm to IS/IEC 60947-4-1 including internal wiring in built short circuit protection astronomical type 63 Amps MCB TPN with IP-54, complete all as specified and directed.
S&F in replacement busbar chamber wall mounted 8 way 100 Amps cubical type, complete all as specified and directed. Make :- Havells Cat Part No. IHBC006308 or technocommercially equivalent make of L&T / Legrand / Indo-Asian / Hager
S&F in replacement switch disconnector panel mounting cubical type, three pole and neutral of capacity 63 Amps, 50 Hz, 415 Volts with bolted type fuse unit with sheet enclosure, complete all as specified and directed. Make :- Havells Cat Part No. IHKDTW4063 or technocommercially equivalent make of L&T / Legrand / Indo-Asian / Hager
S&F in replacement switch disconnector panel mounting cubical type three pole and neutral of capacity 125 Amps, 50 Hz, 415 Volts with bolted type fuse unit with sheet enclosure, complete all as specified and directed. Make :- Havells Cat Part No. IHKDTW4125 or technocommercially equivalent make of L&T / Legrand / Indo-Asian / Hager
S&F in replacement switch disconnector panel mounting cubical type three pole and neutral of capacity upto 400 Amps, 50 Hz 415 Volts with bolted type fuse unit with sheet enclosure, complete all as specified and directed. Make :- Havells Cat Part No. IHFSTW4400 or technocommercially equivalent make of L&T / Legrand / Indo-Asian / Hager
M&L for repair/replacement of the following accessories in panel of high mast light :- (a) Indicating light in Green, Red, Yellow
Terminal block up to 6 way.
Combined multimeter voltmeter and ammeter.
Selctor switch.
Timer On / Off.
Contractor
Control cable 1.5 Sqmm FRLS.
Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connecting to the galvanised iron earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 20mm bore medium grade GI pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, layers of common salt and charcoal filling, test point made out of 40x6mm flat iron with fixing arrangement funnel, wire mesh and earth work in hard/dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electircal plate No. 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion.
S&F in replacement bracket, made out of GI tubing medium grade 32/40mm bore, 90cm long including MS clamp made out of flat iron of size 25x10mm including nuts, bolts and washers etc. and including applying two coats of aluminium paint over a red oxide primer, complete all as specified and directed.
S&F in replacement bracket, made out of GI tubing medium grade 25mm bore, 60cm long including MS clamp made out of flat iron of size 25x10mm including nuts, bolts and washers etc. and including applying two coats of aluminium paint over a red oxide primer, complete all as specified and directed.
S&F in replacement LED lamp 40/50 Watt capacity B-22 base, complete all as specified.
S&F LED driver suitable for street light 60 Watt to 72 Watt, complete all as specified.
S&F LED driver suitable for street light 90 Watt to 120 Watt, complete all as specified.
S&F LED flood light (lense type) of capacity 120 Watt, complete all as specified and directed.
M/S VALLEY ENTERPRISES
M/S Kaleem Constructions
M/S ZENITH TRADE LINK
VEDA INFRASTRUCTURE
M/S Khan Hussain & Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .