Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹6.4 L+₹84,446 (15.2%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance Being Not Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
24 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Prabhat Kumar Singh, AGE (I)
AGE (I) Manauri Allahabad-212212
PRE-MANSOON MAINT SERVICES OF EXTERNAL ELECTRIC SUPPLY AND E/M INSTTALATION UNDER AGE(I) AF MANAURI
2020_MES_345674_2
8812/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Manauri, Allahabad
Class E, Cat b(i)
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
25 Sept 2020
7 Aug 2020
26 Aug 2020
7 Aug 2020
24 Aug 2020
7 Aug 2020
60 days
Amount
Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soil complete.
Removal of surplus excavated material to a distance n.exc. 50 metre and depositing where directed at a level n.exc. 1.5 metre above starting point complete.
M & L for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete. (Note-Punned thickness ie 180mm will be measured and paid)
M&L for brick protection cover over cable of old size Bricks” laid dry over LT cable width of brick shall be laid across the length of cable) complete all as specified and as directed.
Providing PCC 1:4:8, type D2 ( using 40 mm graded crushed stone aggregate) in foundation concrete encasing the pole upto GL. Note :- Volume of pole shall deducted for payment purpose.
PCC 1:3:6, type C-2 ( using 40 mm graded stone aggregate ) as in mass concrete, foundation of stay assembly/post.
Cutting / boring under road/ path/ hard standing etc for across the light grade GI pipe in size upto 80 mm dia drawn through cable run and making good to disturbed surface as per existed using cement concrete type B1 (1:2:4) 20 mm graded aggregate etc as site required specified and directed. Note:- (i) Depth shall be taken minimum 45 cms . (ii) Rate shall be deem to be inclusive cost of PCC.
M&L of trimming/ cutting to tree branches for making minimum arounded clear space 2 Mtrs from OH line / installation and other E/M assets in various location of AOR (area of responsible) as given by Deptt using mechanical machine/ manually with all safety measures including removing to waste materials from site 50 Mtrs distance apart minimum at given site making all clean as per existed complete as directed. Note : Distance between two poles shall be measured against one span.
Opening / tilting /jumpering / binding /re-stringing etc to over head line for any working pressure and No of ACSR runs with insulators/ cross arm/ bracing/ binding wire/ inter connection wire with safe guard and earth wire upto permissible sag using puller or other mechanical equipment between two poles including replacing to required spares such as jumpering and fuse wire / insulators etc all as site required complete and directed. Note : Insulator shall be measured against respective items.
S&F in replacement Pin type insulator 100 mm height, 65 mm dia, 1100 Volt Grade , porcelain, Vitreous, white, brown or green including 01 No. galvanised mild steel spindle, two galvanised iron washers and nuts as directed.
S & F in replacement shackle type insulator, porcelain, Vitreous, white, brown or green 100 mm high and 115 mm dia for working pressure 1100 Volts grade including galvanized mild steel strip of 31 MM x 5 MM size, 14 MM dia insulator bolts, washers, nuts etc. complete as directed.
Taking down/ dismantling of ACSR conductor of any size and any grade from the existing pole all as specified and directed.
Supplying, straining and stringing of aluminium conductor steel reinforced (ACSR) on existing pole/new pole of any size with supply and fixing aluminium binding wire not less than 2 mm dia and connection etc and jointing material for over head lines complete all as specified and as directed.
Dismantling of earth wire or service feeder or distributor span any type and size from the 24 ED area all as specified and directed.
Supply, fixing, cutting, straining, stringing, binding in safe guard etc as site required to galvanised steel wire 3.15 or 4 mm dia using as earth conductor with over head line or safe guard in three run longitudnal and 1 Mtr apart diagonal bracing support hanging on angle Iron / insulators in permisiable sag between two poles incl all site required work to be made seviceable as directed. Note:- Wire length required for sag shall be included in span lenght for measurement.
Dismantaling of old stay assembly and S&F stay assembly complete with accessories as shown in electrical plate no 1 with stay rod of dia 16mm (loop type insulators,stay clamps,excavation and concerete measured seprately)
S&F Loop type insulator small size with overall dimensions 65X90 mm, clearence of hole 16mm all as per specified and directed by engineer-in-charge
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nut and bolt, washers, back plate of any size/shape and Supply fixing cutting welding bolting etc as site to cross arms of mild steel channel or angle sections of required size and shape including clamps, D clamps, eye hooks, back plate with bolts, nuts and washers, welding, bending cold or hot drilling holes for bolts, insulator in any shape or size as required at site including painting using aluminium paint in two coats (one as finishing) over the coat of red primer oxide complete all as directed.
S&F in replacement Stay strand 7/4mm dia all as per specified and directed by engineer-in-charge
S&F in replacement for anti climbing device spikes type fabricated out MS bars (round/ Square and flat) including nuts bolts washers and welding in two halves made to shape to suit the cross section of the pole including painting using aluminium paint in two coats (one as finishing) over the coat of red primer oxide complete all as directed.
M&L for recharging to existed earthing in any type upto strandard value using required chemical such as Nacl/ MgSo4 / other approvad chemical incl reveting / welding/ bolting to earth lead incl testing etc by Tech rep with reveting bolting replacing to nut bolt and washer etc to GI earting strip for making earth continuty from transformer / panels to earting pit complete all as site required and directed.
M&L for cleaning of E/M installations by surface excavation to earth work in minimum 15 CM depth / cutting of grass / cutting of small trees available at installation yard using machine / manually as site required incl removal of waste material from yard not exceeding 50 Mtrs and spraying of antigrass chemical mix with water as per manufacturer instructions and making food of earth surface as per site requirement and all as per specified and directed by engineer-in -charge. Note : (i) Quoted rate shall be included cost required T&P/ antigrass Chemical etc all. (ii) Payment shall be made after burnout vegitation, grass, small tress & clear the earth surface of ground.
Supply and fix in replacement to Driver control plate in existed security light fittings for 45 watts LED light in original manufacture suitable for any model/ make etc all as site complete.
Supply and fix in replacement to Driver control plate in existed security light fittings for 60 watts LED light in original manufacture suitable for any model/ make etc all as site complete.
Supply and fix in replacement to Driver control plate in existed security light fittings for 100 watts to 150 watts LED light in original manufacture suitable for any model/ make etc all as site complete.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanized earth strip 32X6 by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 MM x 300 MM x 300 MM inside dimension) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15 MM thick plaster in CM 1:4, funnel with wire mesh , 80 MM thick PCC pit cover 320 MM x 320 MMof RCC 1:2:4 type B-1 using 20 MM graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 40 MM dia medium grade GI pipe for drawn through to strip and 15 MM dia of bore for watering medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main panel board as specified and testing on completion incl earth work complete including taking down/ dismantling of old earthing all as specified & directed. Note ; (i) RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 MM thick reinforced with XPM weighting not less than 4 Kgs / Sqm in lieu of CI cover (ii) Note :- Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included in the quoted rate.
Supply, laid in trench/ fix/ thembling/ glanding/ clamping on surface of wall / beam/ roof etc in replacement to XLPE insulated armoured heavy duty electric power cable (E) with aluminium conductor 1100 volts garde cross sectional area 35 Sqmm x 3.5 core (earhted) complete including taking down of old cable.
Supply, laid in trench/ fix/ thembling/ glanding/ clamping on surface of wall / beam/ roof etc in replacement to XLPE insulated armoured heavy duty electric power cable (E) with aluminium conductor 1100 volts garde cross sectional area 50 Sqmm x 3.5 core (earhted) complete including taking down of old cable.
Supply, laid in trench/ fix/ thembling/ glanding/ clamping on surface of wall / beam/ roof etc in replacement to XLPE insulated armoured heavy duty electric power cable (E) with aluminium conductor 1100 volts garde cross sectional area 95 Sqmm x 3.5 core (earhted) complete including taking down of old cable.
Supply, laid in trench/ fix/ thembling/ glanding/ clamping on surface of wall / beam/ roof etc in replacement to XLPE insulated armoured heavy duty electric power cable (E) with aluminium conductor 1100 volts garde cross sectional area 120 Sqmm x 3.5 core (earhted) complete including taking down of old cable.
Supply & Fix in replacement of PVC insulated inner sheathing heavy duty electric cable with aluminium conductor, 1100 volt grade cross -sectional area 10 Sqmm x 2 core muilti core stranded conductor ISI marked complete including taking down of old cable all as speicified.
Supply & Fix in replacement of PVC insulated electric cable with aluminium conductor, 1100 volt grade stranded conductor 6 Sqmm x 2 core muilti core stranded conductor ISI marked complete including taking down of old cable all as speicified.
Supply and fixing in replacement to steel water tubing 40 MM bore, galvanized, light grade with and including required fittings such as clamp made out by GI strip in size 32 MM , Nut bolts etc for fixing to cable protection / laid in trenches, under road crossing, fixed on poles /walls etc all as site required and directed.
All as above item No 35 but of size 50 MM bore dia
All as above item No 35 but of size 80 MM bore dia
Supply only aerial fuses porcelain type suitable for line wire with brass contact bolt and nuts maxium current rating 30 Amps in 3 mm dia of wire as directed. Note:- Fixing shall be done by DEL
Supply only aerial fuses porcelain type suitable for line wire with brass contact bolt and nuts maxium current rating 15 Amps in 3 mm dia of wire as directed. Note:- Fixing shall be done by DEL
Supply only Self adhesive PVC insulation tape suitable for 11 KV, 25 MM for HT. Scotch-70
M&L for lightening arrestor non linear resistor type confirming to Fe 410 W (gde -E-250) quality "A" complete line discharge class 3 nominal discharge current 10 KA & high discharge with stand 65 KA assembly suitable for 11 KV working pressure and mounted on hot dip galvanised steel structure including all clamp nuts bolt and washers etc connecting to earth 32 x6 mm GI strip including taking out the same complete all as specified and directed.
Supply , fixing , testing to cable jointing kit for 1100 volt grade (Earthed ) ,end termination/ straight through joiting kit out door type with jointing material and required accessories suitable under ground XLPE ,for 3.5 core 95 to 120 Sqmm complete as directed.
Supply , fixing , testing to cable jointing kit for 1100 volt grade (Earthed ) ,end termination/ straight through joiting kit out door type with jointing material and required accessories suitable under ground XLPE , 3.5 for 50 to 70 Sqmm complete as directed.
Supply and fix in replacement three pole power contactor type ML-6 suitable for 125 Amp range, 240 volt confirming to IS/ IEC 60947- 4-1 & IEC 60947 -4-1 size Fr -3 2 NO+ 2 NC including making connection complete as specified and directed. Make : L&T Model-SS90921 in equivelent Seimens/ Schneider /C&S/MDS
Supply of LED rechagable LED torch 30 W SOS with one year warranty for lead acid battery and connecting copper cable for day to day services complete. Make ; GENERIC cat No RST STR 030xCxRLN4N / Bajaj/ Havells / Usha
Supply only PVC insulated copper conductor muilticore 1.5 Sqmm three core flexible copper cable complete Note:- Fixing shall be done by DEL
M&L for repair maintenance servicing greasing to UNSV GOD in any make/ rating / model etc with replacing to defective spare such as operating handle with insulation , set of insulators/ copper strip fingers set (male and female) / baking nut bolts washer /operating rod riveting, locking arrangement / finger base etc all as site required for making functional smoothly complete all as directed.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
RK Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .