Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 91 B LAXMI NAGAR AIRPORT ROAD INDORE INDORE MADHYA PRADESH 452005 UDYAM MP 23 0000211 | INDORE | MADHYA PRADESH | 452005 | ₹14.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹15.4 L+₹1.3 L (9.13%)Rejected-Finance | ₹15.4 L+₹1.3 L (9.13%) | L2 | Rejected-Finance HIGHEST BIDDER |
| 3 | L3₹15.7 L+₹1.6 L (11.1%)Rejected-Finance MADHUPUR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹15.7 L+₹1.6 L (11.1%) | L3 | Rejected-Finance HIGHEST BIDDER |
| 4 | L4₹16.9 L+₹2.8 L (20.0%)Rejected-Finance SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | ₹16.9 L+₹2.8 L (20.0%) | L4 | Rejected-Finance HIGHEST BIDDER |
Tender Value
₹15.4 L
EMD Value
₹30,900
Closing Date
20 Mar 2023, 6:00 pmClosed
Shri Amit Kumar, AE QS C
Garrison Engineer South RK Gram Diglipur North Andaman 744202
PROVISION OF CERTAIN B/R AND E/M WORKS AT ICGS MAYABUNDER UNDER GE (SOUTH) DIGLIPUR
2023_MES_581986_1
8910/E8
Open Tender
Civil Works
Item Rate
90 days
Garrison Engineer South
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
Garrison Engineer South
₹30,900
Yes
25 Mar 2023
20 Feb 2023
22 Mar 2023
20 Feb 2023
20 Mar 2023
6 Mar 2023
Amount
Taking down cement plastering on brick walls/stone walls/ ceiling etc incl racking out of joints hacking for key scrubbing down with water and disposal of rubbish out of the MOD land.
Material and labor for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished the surfaces even and fair complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying 2 coats of weather coat over a coat of approved primer on old plaster surface to walls complete all as specified and directed
M&L for complete removal of existing treatment of any type & applying 2 coats of weather coat over a coat of approved primer on old plaster surface to walls camouflage painting complete all as specified and directed
Surface excavation n. exc 30cm deep averaging 15cm deep and getting out in soft/loose soil complete all as specified
M&L hard core of gauge exc 63mm deposited ,spread and leveled in layers n exc15cm thick watered and rolled /rammed to a surfaces in broken stones
M&L for cement concrete 1:2:4 type B1 (20mm graded stone aggregate) as in flooring 100 mm thick.
M& L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes. for cement mortar (1:4).
M&L chequered designer tiles 300x300x 25mm size set and pointed in neat cement slurry and pointed in coloured cement to match.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Excavation in trenches n,exc 1.5m wide and 1.5m deep for foundation getting out in soft/loose of soil and complete all as specified and directed.
Excavation in trenches n,exc 1.5m wide and 1.5m deep for foundation getting out in hard/dense of soil and complete all as specified and directed.
M&L for PCC type D2 1:4:8 (using 40mm graded granite stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
M&Lfor pre-cast cement concrete masonry in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) with solid block, exceeding 10cm in width setting in CM 1:4 complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade and complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
Returning, filling in excavated soil including, spreading, leveling, watering, well ramming in layers not exceeding 25 cm all as specified.
M&L for rendering 15mm thick on fair faces of concrete surfaces in CM 1:4 and finished even and smooth without using extra cement (internal) complete all as specified and directed.
M&L Marble tiles 30cmx20cm x 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing types complete all as specified and directed.
Rough excavation n exc. 1.5m deep and getting out in soft/loose of soil and removing of soil to fill lowering area and complete all as specified and directed.
Rough excavation n exc. 1.5m deep and getting out in Hard/dense of soil and removing of soil to fill lowering area and complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30cm thick watering, ramming/ rolling and finishing to required size, shape exceeding 1.5m and not exceeding 3m high from base and rolling of the top layers complete all as specified and directed.
Excavation in post holes each n.exc 0.5 cum ,getting out ,returning ,filling in and ramming earth or broken rubble mixed in soft/loose soil complete all as specified
Excavation in post holes each n.exc 0.5 cum ,getting out ,returning ,filling in and ramming earth or broken rubble mixed in hard/dense soil complete all as specified
S&F stainless steel pipes railing/balusters etc made out of stainless steel pipe of grade 304 of approved dia and thickness pipe and other connected fittings including welding ,drilling complete all as specified and including polishing etc complete.
M&L for point wiring complete with 1.5 sqmm single core, PVC insulated, unsheathed, FRLS, 1100V grade multistranded copper conductor cable, ISI marked, drawn through and including medium grade rigid PVC casing & capping complete all as specified and as directed by the Engineer-in-charge. (a) One light point controlled by one way switch .
Supply and fixing ceiling rose, 3 terminal, PVC/Polycarbonate isolated body.
Supply and fixing of Switch piano, flush type single pole one way 5 Amp all as specified and as directed.
S&F MCB DB SPN 08 Way 230 Volts Double Door including cutting and chasing of wall for fixing of DB complete all as specified
S&F Amp rating 240V,10KA 'C' curve MCB 32 Amp of single poles neutral carrying capacity complete with connection in testing & commissioning
S&F Amp rating 240V,10KA 'C' curve MCB SP 6-20 Amp of single poles neutral carrying capacity complete with connection in testing & commissioning
S&F LED light fitting 1X20W, 220V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper ender for cable of suitable size for ceiling complete.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminum conductor of sizes 10 Sqmm x 2 Core.
Supply and laying of DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II , of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler,'O' Ring etc, for protection of cable complete all as specified and as directed.
M&L for earthling complete with galvanised steel plate electrode of size 600x600x6.30mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar funnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil with and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed. Note: (i) The Rate for Taking down the old unserviceable earthling shall be deemed to be included in the unit rate. (ii) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Supply and Fixing of Post Top Lantern LED Type of size 40 watt with IP 65 protection, Inverted pyramid tripod type LED bollard with soft 360 degree light distribution,Resistant to impact and corrosion,glare free and better uniformity complete all as specified and directed. Make: Crompton,Cat No: LPTO-40-CDL OR equivalent to Philips/Bajaj .
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity of 1.5 TR.
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA .
S&F new copper tubes of suitable size for suction and discharge lines for split type air conditioner including necessary brazing, wrapping up puff insulation, testing on completion all as specified and as directed by the Engineer-in-Charge. (Note : one run of suction, one run of discharge pipes shall be measured as one unit length)
S&F 25x25x6 mm angle iron frame fixed on brackets duly painted as directed by Engineer -in-Charge
M&L for sub main wiring with 2 run of 4 Sqmm PVC insulated coper coductor as main wire and 1 run of 2.5sqmm PVC insulated coper conductor as earth wire single core cable in surface type of working voltage 1100 Volts drawn in required size of PVC casing coping non- metallic complete all as specified and as directed. (Note : Two run of submain 4sqmm wiring cable, one run 2.5 sqmm and one run of PVC casing coping pipe shall be measured and paid as one unit length).
RADHA GOVIND CONSTRUCTION
Binod Hawlader
MOHAMMED SAFIQUE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .