Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
31 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT OF E/M NATURE OF WORKS OF OTM ACCN AND MANEKSHAW CENTRE UNDER AGE (P) MC OF GE (SOUTH) DELHI CANTT-10
2022_MES_566938_1
GE/DS-94/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
17 Jan 2023
2 Dec 2022
2 Jan 2023
2 Dec 2022
31 Dec 2022
17 Dec 2022
Amount
Attending complaints for checking the existing electrical items for continuous electric supply including carrying out minor repair etc as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. Attending minor repair such as testing, electric connections, fittings, nut, bolts and screws etc to ceiling fan, exhaust fan at its initial position (without taking down) etc, emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electrical system of main building/block for uninterrupted electric supply including carrying out minor repairs etc. required to make the system in order/functional with insulation tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and as directed.
Notes :- 1. The site for attending complaints are OTM Accn and Manekshaw Centre at Manekshaw Centre Contractor shall provide adequate (miniumum one) Tradesmen (Electrician) alongwith Helper to attend the complaints all the above areas in all working days between 0830 Hrs to 1630 Hrs including holidays and sundays if required of the direction of Engr-in-Charge. 2. The Manekshaw Centre is a prestigeious building have ceiling height varying from 4.00 mtr to 8.50 mtr. It is therefore necessary movable ledder/scaffolding upto 4 mtr height arrangment are be made by the contractor to attend the complaint which should be readly available and contractor quoted rate are inclusive for the same. However where it is inescapable necessary 4 leg scaffolding shall also be provided by the contractor and the same shall be measured and paid under Srl items 74 of this schedule. 3. Contractor shall ensure the security passes for his staff, to be obtained from concern authority for attending complaints. 4. The contractor will ensure that the team of electricians with necessary tools bag, shall always remain present at complaint cell to attend the complaints. 5. The complainted are to be attended immediately i.e. within 30 minutes. If the complaint not attended within 30 minutes necessary recovery (panelty) per complaint for not attending the complaint within stipulated time shall be made from the contractors claim as under :- (a) Not attending the complaint 30 minutes to 2 Hrs - Rs.240/complaint. (b) Not attending the complaint beyond 2 Hrs & upto 4 Hrs - Rs.480/complaint. (c) Not attending the complaint beyond 4 Hrs - Rs.2400/complaint.
Notes (Contd.....) 6. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 7. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 8.The above tradesmen shall also be utilize for taking down of unsv and fixing of fitting/fixture, lights etc where specified "supply only in replacement" under respective item of this schedule. 9. Store shall be provided to electrician against supply only items here in below. 10. The rates quoted by the tenderers are deemed to be included for necessary 4 legs steel/bamboo scaffolding and safety precuatisions upto 4 mtr height. Beyond 4 mtr height scaffolding shall be measured and paid seperately. 11. The complaints per day may vary from NIL complaint to 10 complaint per day appx. The manpower may be sitting idle when no complaint are received and no claim shall be entertained while sitting idle or not getting complaint. The quoted rate by the contractor are deemed to be included for this provision.
All as per Srl item No. 1 above but attending complaints in between 1630hrs to 2300hrs.
Taking down burnt/unserviceable copper/aluminium point wiring (light, fan, socket or pwer) complete including fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of modular sunken pressed steel terminal boxes 2mm thick of required size and modular white cover plate with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete and making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and as directed. Note :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per Srl item No 4 above but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on independent board.
All as per Srl item No 4 above but one 3 pin 5 Amps socket outlet point controlled by one No one way modular switch and modular socket on same board.
All as per Srl item No 4 above but point wiring for 16 Amps for modular socket point with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amps modular switch/socket outlet point on independent board.
All as per Srl item No 4 above but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing.
All as per Srl item No 4 above but for one AC point controlled using cable of 4 Sq mm for phase and neutral and 4 sqmm for earthing.
S&F in repais Switch modular type, 1Module, 6 Amps one way as per sample complete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs of Switch modular type 1M 6 Amp 2-way as per sample complete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs of Socket outlet modular type 2M, 2/3 pin, 6 Amp as per samplecomplete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs of Switch modular type 1M, 16 Amp as per sample complete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs of Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp as per sample complete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs of Electronic fan regulator, modular type 2M, 4 steps, as per sample complete all as specified and as directed. Make :- Model Crabtree of Havells/Model - Unica of Schneider/ Model - Marius of Legrand
S&F in repairs Modular box with MCB 20 Amp complete with metal box and 3 Pin top plug as per sample complete all as specified and as directed. Note : Rates are inclusive of cutting / chases for mounting modular metal box concealed in wall and making good to disturbed surfaces with OBD / Colour wash / white wash and wall putty where ever required complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing) complete all as specified and as directed. One light/fan/bell point/security light conrrolled by one way switch. Note:- The rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 adn same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash completed.
All as per Srl item No.17 here-in-before but one 3 pin socket outlet, 5/6 Amps, independent, with cable 1.5 Sqmm size complete all as specified and as directed.
All as per Srl item No.17 here-in-before but 5 Amp socket outlet on same board complete all as specified and as directed.
All as per Srl item No.17 here-in-before but for one socket outlet 15 Amps on independent board with cable 2.5 Sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and as directed.
All as per Srl item No.17 here-in-before but for one light controlled by 2 Way switch using cable 1.5 Sqmm size for phase and neutral and 1.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and as directed.
Supply only in replacement switch piano flush type 5/6 Amps SP one way complete all as specified and as directed.
Supply only in replacement switch piano flush type 5/6 Amps SP two way as per sample complete all as specified and as directed.
Supply only in replacement socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose as per sample complete all as specified and as directed.
Supply only in replacement switch piano flush type 15/16 Amps SP one way as per sample complete all as specified and as directed.
Supply only in replacement universal socket outlet 2-in1 (multipurpose) 5 pin 6/16 Amps flush mounted type as per sample complete all as specified and as directed.
Supply only in replacement 0-4 step type electronic regulator for ceiling fan 1200/1400 sweep, 240 V as per sample complete all as specified and as directed.
Supply only in replacement decorative wall light mounting suitable for LED lamp upto 15 Watt complete all as specified and as directed.
Supply only in replacement rose surface bakelite 65x25 mm two to three terminals complete all as specified and as directed.
Supply only in replacement of lamp holder bakelite insulated body with back plate suitable for batten fitting complete all as specified and as directed.
Supply only in replacement wall mounted LED integrated batten T-5 20 Watt - 4ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
Supply only in replacement wall mounted LED integrated batten T-5 10 Watt - 2ft white 6500K, indoor decorative PVC extruded T-5 LED batten - integrated type as per sample complete all as specified and as directed.
Supply only in replacement surface mounting round/square shape LED down lighter 10 Watt any type complete with including new flexible wire as requried on site in replacement of old unsv existing ceiling light fitting complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit including taking down of old unsv submain complete all as specified and as directed.
S&F in repairs submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit including taking down of old unsv submain complete all as specified and as directed.
S&F in repais submain wiring PVC insulated FRLS single core unsheathed, multistrand copper conductor cable of size 2.5 Sqmm in 2 runs and 2.5 Sqmm one run for earth drawing through existing PVC concealed conduit including taking down of old unsv submain complete all as specified and as directed. Note for Srl item No 34, 35 & 36 (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Supply only in replacement MCCB 63 Amps 4 pole 415 volts fixed type with breaking capacity 10 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
Supply only in replacement MCCB 100 Amps 4 pole 415 volts fixed type with breaking capacity 10 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
Supply only in replacement MCCB 125 Amps 3/4 pole 415 volts fixed type with breaking capacity 16 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
Supply only in replacement MCCB 160 Amps 3/4 pole 415 volts fixed type with breaking capacity 16 KA 415 Volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc as per sample complete all as specified and as directed.
Supply only in replacement for MCB SP 10 to 40 Amps 240 Volts, 10 KA, `C' curve, all as per site requirement and complete all as specified and as directed.
Supply only in replacement for MCB SPN 63 Amps, 240 Volts, 10 KA, `C' curve, all as per site requirement and complete all as specified and as directed.
Supply only in replacement MCB TPN 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and complete all as specified and as directed.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement and complete all as specified and as directed.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 2.5 Sqmm single core for any type of wiring as per site requirement in green colour and complete all as specified and as directed.
Supply only in replacement PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm single core for any type of wiring as per site requirement complete all as specified and as directed.
S&F in repairs Audio cable including all connection as per sample complete all as specified and as directed.
S&F in repairs video cable including all connection as per sample complete all as specified and as directed.
S&F in repairs HDMI cable including all connection as per sample complete all as specified and as directed.
S&F in repairs cordless Mike including charging set as per sample complete all as specified and as directed.
Taking down of old unserviceable ceiling fan/exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation and testing complete all as specified and as directed. Note : Rewinding will be measured and paid separately under this Schedule.
M&L for Rewinding of ceiling fan 1200 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required complete all as specified and as directed.
All as per Srl item No.52 above but exhaust fan 230/300/450 mm sweep as per sample.
S&F in repairs MCB DB SPN 8 Way double door type, (IP 43 Protection) flush mounting as per sample complete all as specified and as directed.
S&F in repairs LED Building security light fitting 40W including GI 25mm bracket in replacement of old unsv existing security light fitting any type complete all as specified and as directed.
Supply only in replacement LED Bulb 12 Watt B-22 Cap, AC 230V, 50 Hz, suitable for Batten Holder/Bulk head/SK light fittings as per sample complete all as specified and as directed.
S&F in repairs of distribution board V-TPN 4 way for fixing MCCB 125 Amps as incommer and MCBs as out goings with metal door and IP 43 Protections and connecting in replacement complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 x 600 x 6mm thick burried directly in ground in ground (earth pit plate kess than 2.5 mtrs below ground level) with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade with funnel and locking arrangement complete all as specified and as directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicate dsituation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
S&F in repairs of earth continuity conductor or main earthing lead fixed to roof wall other indicate situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron strip as per site requirement compelte complete all as specified and as directed. Note :- Staircase arrangement for fixing of earth continuity upto to second floor shall be made by the contractor without any cost.
S&F in repairs of track mounting light including all connection as per sample complete all as specified and as directed.
S&F in repairs of thermostat 9/11" (ISI Marked) for 25 Litres capacity Geyser as per sample complete all as specified and as directed.
S&F in repairs MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and as directed.
Supply only in replacement heating element of 1.5 KW including rubber washers (ISI marked) etc as per site requirement complete all as specified and as directed.
S&F in repairs of storage tank made out of SS Steel sheet of appropriate thickness and confirming to IS 208 (1974) or as per sample for 25 litre capacity geysers with collar, duly tested at required pressure complete all as specified and as directed.
S&F in repairs of safety plug and nut for high pressure release as per sample complete all as specified and as directed.
S&F in repairs of non return valves 15mm dia made up of brass as per sample complete all as specified and as directed.
Supply only in replacement ceiling fan capacitor of 2.5 mfd complete all as specified and as directed. Make : TIBCON/AE/ EPCOS/Havells
Supply only in replacement exit light including all connection as per sample complete all as specified and as directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip armoured ,electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 16 sqmm, 4 core including taking down of old unsv cable complete all as specified and as directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip armoured ,electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 25 sqmm, 3.5 core including taking down of old unsv cable complete all as specified and as directed.
Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip armoured ,electric power cable (heavy duty ) 1100 volt grade with stranded aluminium conductor of size 35 sqmm, 3.5 core including taking down of old unsv cable complete all as specified and as directed.
Hiring and providing (aluminium/steel) scaffolding with suitable size to attend the complaints where the room it is more than 5.00 mtr complete all as specified and as directed. Note :- 1. The rate quoted by the tenderer are deemed to be included for hiring, transporting (both side), assembling & dismantling of scaffolding after attending the complaint. 2. The complaint shall be measured and paid seperately under Srl item No. 1 & 2 of this schedule. 3. This item shall applicable only Srl item No.1 & 2 of this schedule.
M&L for comprehensive maintenance and overhauling quarterly (every four months commencing from actual date of commencment of work) of scissor lift platform mounted of size 1500 x 1000 mm capacity 250 Kg stage height 1200 mm with hydrulic pump, motor suitable for to take a wheel chaired person alongwith one attendent installed in Zorawar Auditorium of Manekshaw Centre by performing following task complete all as specified and as directed:- (a) Inspection of brakes, Drive Control. (b) Cleaning of contraol panel. (c) Inspection of control Panel. (d) Electrial Panel. (e) Insepction of safety indication light. (f) Insepction of platform. Note :- Each comprehensive maintenance shall be measured and paid as one Job.
Dismantling/disconnection of curtain motor 3 phase, 415 volt, 1.5/2 HP from plateform on roof height complete over hauling/servicing of electricmotor for front/middle/rear curtain including replacement of bearing/brush and unserviceable SWR rope of suitable size and greasing of pullies/gears and refixing after repair the same location in auditorium complete all as specified and as directed.
S&F in repairs of pressure pipe suitable for existing scissor lift (any capacity and size) matched with system/machine fitted in Manekshaw centre complete all as specified and as directed.
Supply only compressor oil suitablefor existingscissor lift/curtain motor (any capacity & size matched with system/machine fitted in Manekshaw Centre complete all as specified and as directed.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
Microsys Controls India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .