Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
30 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where:- V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work -"Any Signalling work"
26 conditions · 7 needing a document upload
Statement of Deviation
Power of Attorney
Certificate to be submitted / uploaded by tenderer along with the tender documents (Annexure V), Part I of GCC.
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
EMD Submitted
Copy of PAN card
Documents for Turnover for financial eligibility criteria
Documents for technical eligibility criteria - Performance certificates for single similar nature of work
NEFT Details
GST Registration Certificate Copy
Bid Security Declaration in lieu of EMD Submitted
Organization details
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where:- V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
Power of Attorney
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
NEFT Details
Copy of PAN card
Organization details
GST REGISTRATION/ A CERTIFCATE FOR NON-APPLICABILITY OF GST REGISTRATION
Bid Security Declaration in lieu of EMD Submitted
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Signaling and Telecommunication portion of work in connection with various engineering works in AJJ-JTJ Section over Chennai division (AJJ-JTJ-01/2026)
M-SG-2026-499-AJJ-JTJ_1
M-SG-2026-499-AJJ-JTJ_1
Open
Works - General
12 Months
Chennai, Tamil Nadu
₹0
₹2.3 L
30 Mar 2026
6 Mar 2026
16 Mar 2026
45 items across 1 schedule · ₹57,19,223.38 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply o f earth electrodes (GI) a s p e r Drg no SG/CN/02/13 | Numbers | 12.00 | 1,618.75 | 19,425 |
| 2 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 12.00 | 1,707.55 | 20,490.6 |
| 3 | Supply o f 2 4 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 1500.00 | 388.15 | 5,82,225 |
| 4 | S u p p l y o f 1 2 C x 1 . 5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable a s p e r IRS: S-63/2014 REV.4 | Metre | 2000.00 | 215.92 | 4,31,840 |
| 5 | " S u p p l y o f 2 x 2 . 5 s q . m m P V C insulated Armoured, unscreened, underground Railway S i g n a l l i n g C o p p e r c a b l e a s p e r spec IRS.S.63/2014(Rev.4.0) or latest" | Metre | 1000.00 | 98.76 | 98,760 |
| 6 | Supply o f 1 6 Sq.mm multistrand Flexible APC PVC insulated copper cable as per IS 694 | Metre | 45.00 | 228.14 | 10,266.3 |
| 7 | S u p p l y o f P o l y t h e n e I n s u l a t e d Polythene Sheathed armoured Jelly Filled Telephone Cable with Poly-AL Moisture Barrier, 20 Pairs, 0.63 MM Conductor Diameter as per RDSO Specification No. IRS:TC-41/97 with amendment 1 or latest | Metre | 500.00 | 258.2 | 1,29,100 |
| 8 | Laying o f STP/OFC/Power Cable/ switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case c a p i n g a n d clamping on the wall/Roof tops/ Shelters with suitable clamping a n d hose t o b e provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor) | Metre | 5820.00 | 37.3 | 2,17,086 |
| 9 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 3400.00 | 64.1 | 2,17,940 |
| 10 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ram m ing a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 174.00 | 385.45 | 67,068.3 |
| 11 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 80.00 | 208.54 | 16,683.2 |
| 12 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Metre | 182.87 | 182.87 | 33,441.44 |
| 13 | Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 13500.00 | 18.18 | 2,45,430 |
| 14 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 3400.00 | 62.99 | 2,14,166 |
| 15 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 3100.00 | 15.4 | 47,740 |
| 16 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of the f o u n d a t i o n a n d r e fi l l i n g t h e p i t and consolidating it by ramming. The cable markers shall b e provided a t a n interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers | 45.00 | 123.35 | 5,550.75 |
| 17 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: T h e pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DW C pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 220.00 | 1,351.45 | 2,97,319 |
| 18 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid l u b r i c a t e d H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre | 5800.00 | 23.43 | 1,35,894 |
| 19 | Supply of cable termination box (FRP type) with necessary inspection a s per specification/ drawing/ description enclosed in this document. | Numbers | 38.00 | 7,788 | 2,95,944 |
| 20 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 3.00 | 23,192.34 | 69,577.02 |
| 21 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 1.00 | 33,510.29 | 33,510.29 |
| 22 | S u p p l y o f Ro d o m e t e r a s p e r Technical specification | Numbers | 4.00 | 4,252.24 | 17,008.96 |
| 23 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 226.00 | 1,119.16 | 2,52,930.16 |
| 24 | S u p p l y o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s per specification N o . I S 4984: 2016 with latest amendments and Material Grade:PE 80 | Metre | 358.00 | 853.55 | 3,05,570.9 |
| 25 | Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre | 5800.00 | 60.93 | 3,53,394 |
| 26 | Supply and Installation of Wall/Rack mountable 1 2 F i b r e m a n a g e m e n t system (FMS) conforming t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE make o r b e t t e r , s u i t a b l e for splicing and front patching 12F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length ( A l l other materials required for splicing are to be supplied by contractor) | Numbers | 12.00 | 10,502 | 1,26,024 |
| 27 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary i n s p e c t i o n a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 142.00 | 1,622.5 | 2,30,395 |
| 28 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 1630.00 | 61.44 | 1,00,147.2 |
| 29 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 270.00 | 93.02 | 25,115.4 |
| 30 | Supply o f PBT terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 210.00 | 103.84 | 21,806.4 |
| 31 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed in this document a)Supply of apparatus case - Full size | Numbers | 6.00 | 18,821 | 1,12,926 |
| 32 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection a s p e r specification/ drawing/ description enclosed in this document b)Supply of apparatus case - Half size | Numbers | 4.00 | 15,576 | 62,304 |
| 33 | Excavation o f pit, casting concrete foundation and erection of apparatus case full size a s per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 6.00 | 11,333.1 | 67,998.6 |
| 34 | "Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]""" | Numbers | 4.00 | 8,787.04 | 35,148.16 |
| 35 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing t h e opening created f o r entry o f new cables i n the apparatus cases w i t h masonry b r i c k work and sealing t h e b o t t o m o f the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, s e a l i n g compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 800.00 | 73.59 | 58,872 |
| 36 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination on 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 600.00 | 172.14 | 1,03,284 |
| 37 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood i t e m s , fi x i n g of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 80.00 | 209.93 | 16,794.4 |
| 38 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. a)Termination o f c a b l e s on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 1300.00 | 151.09 | 1,96,417 |
| 39 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level and the bottom surface shall be sealed with sealing compound. b)Termination of cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 130.00 | 188.86 | 24,551.8 |
| 40 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 5800.00 | 26.11 | 1,51,438 |
| 41 | Releasing o f existing point lay-out with facing point lock,split stretchers, electrical detector, l o c k b a r s , point/trap indicators cranks, rods etc., carefully without Damaging the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 1.00 | 2,852.7 | 2,852.7 |
| 42 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 120.00 | 847.59 | 1,01,710.8 |
| 43 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cable s, m i n o r patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing e t c a s per instruction of Railway representatives at size. | Man- Days | 60.00 | 1,073.45 | 64,407 |
| 44 | Transportation o f Signalling materials more than 100km | MT-Km | 4500.00 | 13.91 | 62,595 |
| 45 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e form atio n, dismantling a n y infringing structures, clearing a n d removing debris etc., with all leads and lifts etc., complete and as per t h e instruction o f Railway representative at site. | Hour | 30.00 | 1,202.5 | 36,075 |
| Schedule total | ₹57,19,223.38 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
GCCCorrectionslip1to10.pdf
ATTACHMENT
SOR2011BOOKLET.pdf
ATTACHMENT
VolumeIIBOOKLET.pdf
ATTACHMENT
JPOforundertakingtheDiggingwork1.pdf
ATTACHMENT
CopyofTenderDocumentforSTworkInconnectionwithEnggWorksinAJJ-JTJ-1section.docx1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .