Executive Engineer MHD, Srinagar
Office of Executive Engineer, MH Division Srinagar
Providing, fitting and testing of Oxygen and Vaccum Points along wih allied works in various section of Labour Room of Govt. L.D Hospital, Srinagar
2024_PWDJK_244218_1
MHDS/TS/2023-24/180/ e-tendering Dated02-02-2024
Open Tender
Repair and Maintenance Works
Item Wise
10 days
Govt LD Hospital
As detailed in NIT
4 documents required · 4 mandatory
₹100
Executive Engineer MHD SGR
₹2,500
15 Mar 2024
2 Feb 2024
14 Mar 2024
2 Feb 2024
14 Mar 2024
2 Feb 2024
Amount
Providing, fitting and testing of ward vaccum units (600ml)complete with suction regulator and compatible probe. The ward vaccum units of 600ml capacity shall be designed for minimum servicing and high efficiency. The body shall house an ON/OFF knob, vaccum guage graduated in millibars. The jar of the vaccum unit shall be transparent made of polycorbonate, unbreakable to the temperature of 134 degree centigrade. The unit shall be provided with fluid control trap(safety)fitted on the unit and wall automatically and efficiently shut off vaccum fully, preventing the transfer of liquid to the vaccum regulator,pipe line and pump. The vaccum units are to be fitted on walls with the help of brackets. The job shall be inclusive of high pressure vaccum pipe of length not less than one metre/job.
Dismounting of old malfanctioning of wall suction points. Providing, fitting, and testing of self sealing of (front load doubled locking)includinh cover for suction supply, The valve shall be installedon the wall with its inlet connected to the copper tubing carrying suction pipe by means of brazing with silver electrode. The job includes Providing and fitting of necessary copper fitting along with isolation valve complete in all respects. The valve shall be noninterchangable, self sealing. quick connect gas outlet for suction suitable for head wall units/walls. The front facia of valves shall be non interchangable and gas colour coded
Providing, fitting, and testing of new BPC oxygen flow metre with humidifier bottles connected to the self sealing valves of oxygen and compatible probe. BPC oxygen flow metre shall be offering the latest techinical improvements for a precise measuring of the flow with +/-5% accuracy. The body of the flow metre shall be chrome plated brass graduated flow tube and cover made of polycarbonate. The flow metre shall have adjustable flow by needle valve with micro metrical regulation. The flow metre shall be able to compensate back pressure and shall have standard flow of 0-15 LPM The inlet filter of flow metre shall be made of staimless steel wire net and is connected to the outlet of self sealing valve with humidifier bottles. This includes Providing and fitting of necessary copper fittings complete in all respects
Dismounting of old malfanctioning of wall oxygen points.Providing, fitting, and testing of oxygen self sealing valve assembly (front load doubled locking) including cover for oxygen supply, The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen pipe by means of brazing with silver electrode. The job includes Providing and fitting of necessary copper fitting along with isolation valve complete in all respects. The valve shall be noninterchangable, self sealing..quick connect gas outlet for suction suitable for head wall units/walls. The front facia of valves shall be non interchangable and gas colour coded.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .