Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance H NO 18 7 599 32 A VIVEKANANDA NAGAR CHATRINAKA HYDERABAD 500 053 | HYDERABAD | HYDERABAD | TELANGANA | 500053 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
6 May 2024, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
REPAIRS TO ROOF SHEET, ROOF TREATMENT, EXTERNAL PLASTERING AND OTHER MISC WORKS OF OTM / MD ACCN AT MH/MD AREA OF AGE B/R-II UNDER GE GOLCONDA
2024_MES_648768_1
8772/E8
Open Tender
Civil Works
Item Rate
270 days
HYDERABAD
As Per Tender
8 documents required · 8 mandatory
₹500
GE GOLCONDA
₹70,000
Yes
10 May 2024
1 Apr 2024
8 May 2024
1 Apr 2024
6 May 2024
29 Apr 2024
Amount
Dismantling Asbestos cement sheet (Corrugated/Semi-corrugated etc.) in roof covering complete all as specified and directed.
M&L for 6 mm thick non Asbestos cement fibre corrugated sheet in roof, fixed with J or L hook or cranked bolt with washers complete all as specified and directed.
Fixing only 6 mm thick Asbestos cement corrugated sheet in roof, fixed with J or L hook or cranked bolt with washers complete all as specified and directed.
S & F 6 mm thick non Asbestos cement fibre two pieces adjustable serrated ridge fixed with J or L hook or cranked bolt with washers complete all as specified and directed.
Dismantling plain or corrugated steel/alluminium sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc complete all as specified and directed.
S&F 0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F for MS Framed work as in Flat iron supports to hold the valley gutters of rain water etc. with ends shouldered and/or riveted and similar work conforming to Fe.290.Gde-E-165 including taking down complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm dia complete all as specified and directed.
S&F for 110 mm PVC (SWR) pipes single socket length fixed as spouts on roof including cutting holes in brickwork/stone masory/concrete surface and making good with rich cement mortar and sealed with bitumen complete all as specified and directed.
Disconnecting existing tanks of capacity exc 250 ltr & n exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately),etc complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500 ltr & n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately),etc complete all as specified and directed.
Demolition of cement concrete on roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work etc complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof padding with WPC complete all as specifed and directed. (NOTE : Supply of WPC will be paid under the respective Item)
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bitumnious primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminium paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including rendering 10mm thick in cm 1:4 on concrete surfaces of roofs, parapet etc. finishing to surfaces even and smooth without using extra cement and provinding necessary slope with using WPC @ 3% by weight of cement complete incl taking down existing froof treatment and cement plaster of any description, roughing, preparing the surface by cleaning the surface with wire brushing scrubbinbg down with water to receive new treatment all as specified and directed. (NOTE : Supply of WPC will be paid under the respective Item)
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bitumnious primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminium paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including taking down existing roof treatment on parapet walls, preparing the surface by cleaning with wire brushing, scrubbinbg down with water to receive new treatment all as specified and directed.
Supply only integral water proofing compound.
Dismantling single layer mangalore pattern or similar tiles laid dry in roofing complete all as specified and directed.
M & L roof tiles mangalore pattern interlocking at side joints laid dry complete all as specified and directed.
Fixing only roof tiles mangalore pattern interlocaking side joints laid dry complete all as specified and directed.
M & L for Ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6, etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc.) or insulation boards/ slabs/ blankets any thickness, incl cover filltets and grids and S&F for true horizontal level 600x600mm panels false ceiling system using hot dipped galavnized steel sections exposed surface with pre-coated capping, Main Tee of size 24x32mm at every 1200mm c/c maximum, rotary stitched cross Tee of size 24x 27mm at every 1200mm c/c and wall angle of size 19x19mm fixed to perimetre wall. The complete grid is to be suspended at every 1200mm c/c in both directions by using 2mm dia pre straightened GI wire at every 1200mm interval at the main Tee using fine finished tagular edge including 9 mm thick Gypsum boards of size 600x600 mm with rear side Aluminium fril and front side PVC lamination complete all as specified and directed.
Dismantling Battens for tiles exc 15 cm, shingles etc, of any size including tilting fillets complete all as specified and directed.
M&L for 2nd class hard wood Clean sawn batten for tiles sectional area exc 15 & n. exc 25 Sqcm at 30 cm C / C complete all as specified and directed.
M&L for Tiles or slate battens , any size and spacing, prepared (Old / New) and treated all over (measured overall on one side only, spaces not deducted) with two coat of creosote complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L Weather boarding of 2nd class H.W of 20mm to 25mm thick and rebated of thick edge to give 20mm lap and fixed with screws/nails including one coat primer and two coat synthetic enamel paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new or untreated wooden surfaces exc 10 cm in width or girth including preparation complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc completed all as specified.
S&F Rolled mild structural steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W (Gde-E) all as specified and directed.
Taking down cement plaster on brick wall/stone wall, ceilings etc, racking out joints, hacking for key & scrubbing with water complete all as specified and directed.
M&L rendering 15mm thick in CM 1:4 with WPC on fair faces of brick surfaces of walls finished the surfaces even & smooth without using extra cement complete all as specified and directed. (NOTE : - WPC will be measured and paid separately)
Preparing newly plastered surfaces and applying two coats of cement based paint on walls complete all as specified and directed.
Preparing newly plastered surfaces and applying two coats of colour wash on walls complete all as specified and directed.
S&F for 110 mm PVC (SWR) pipes as in rain water pipes single socketed in any length with rubber ring joints fixed to wall including taking down existing pipe complete all as specified.
Cutting out V-groovesin plaster / masonary and inserting the waterproofing membrane and making good in CM 1:3 complete all as specified and directed.
M&L for Cleaning of roof/ terraces (accessible/non accessible) including removal of dirt, mud, debris, shrubs, grass (if any) etc. and disposing off the waste outside of cantonment complete all as specified and directed.
harshraj and co
M/s Amit Associates
Dwarka Pershad Radhey Ramanlal
RAM CHARAN CONSTRUCTIONS
VACON INFRASTRUCTURES
SM CONSTRUCTIONS
M/S Veerabhadra Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .