Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.0 Cr
EMD Value
₹2.0 L
Closing Date
23 Feb 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Construction of 24x7 PHC Building at Mahadevpali of B.MPUR Block under National Health Mission in the Sonepur district of Odisha (Scope of work in addition to above is uploaded separately along with this NIT)
NBCC/ODISHA/ZO/NHM/NIT/22-23/34
NBCC/ODISHA/ZO/NHM/NIT/22-23/34
Open Tender-Domestic
Civil Works General
Sonepur, Odisha
₹11,800
₹2.0 L
23 Feb 2023
8 Feb 2023
23 Feb 2023
23 Feb 2023
9 Mar 2023
Head Description of Item Unit Qnty. Rate Amount
Earthwork in excavation in hard soil for site
leveling, foundation, pits, trenches and
other civil works upto and including
1.5metre lift and stacking the soil upto a
2 1 lead of 100 metre and including Cum 769.08 235.53 1,81,138.81
dewatering, removing slush, shoring and
strutting (as required), complete as per
specification and as directed by the
Engineer-In-Charge.
Filling in foundation trenches and plinth,
with excavated earth including laying the
earth in layers not exceeding 23.5 cm thick
ramming & watering with all leads & lifts
including cost of all labour,T&P completed
as directed by the Engineer-in-charge.
Supplying and filling sand in foundation and
over areas including watering, ramming,
consolidating and dressing, labours, tools,
taxes etc. all complete as per the
specification and direction of Engineer-In-
Diluting and injecting chemical emulsion for
PRE CONSTRUCTIONAL Anti-termite
treatment and creating a continuous
chemical barrier under and all-round the
column pits, wall trenches, basement
excavation, top perimeter of building,
expansion joints, over the top surface of
consolidated earth on which apron is to be
laid, surroundings of pipes and conduits
etc. complete as per specifications (plinth
area of the building at ground floor only
shall be measured for payment).
Providing and laying plain cement concrete
1:3:6 (1 cement : 3 sand : 6 stone
agregate 40mm nominal size) as levelling
course in floor and plinth including
tempering, curring, shuttering etc.
complete all depth and height.
Providing and laying plain cement concrete
1:2:4 (1 cement: 2 sand: 4 stone
aggregate 12mm nominal size) as levelling
course in foundation and plinth etc.
including tempering, curring, shuttering
etc.complete all depth and height.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
First class Fly ash Brick masonry using
bricks of size 25 cm. x 12 cm. x 8 cm.
having crushing strength not less than 75
kg. Per. Sqr. Cm. in cement mortar of mix(
1:6) with ordinary Portland slag
cement(PSC) and screened & washed sand
for mortar after immersing the bricks for 6
(Six) hours in water before use in
8 7 Foundation & Plinth including splays Cum 38.81 5727.13 2,22,270.63
cutting, circular moulding, corbelling,
chamfering and similar such type of works,
watering and curing etc. including cost,
conveyance, loading, unloading, royalties
and taxes of all materials, cost of all labour,
scaffolding, sundries, T&P required for the
works etc. complete in all respect as
directed by the Engineer-in-Charge.
Fly Ash. brick masonry of size 25 cm. x 12
cm. x 8 cm. having crushing strength not
less than 75 kg. Per Sqr. Cm. in cement
mortar of mix (1:6) with approved grade
cement and screened & washed sand for
mortar after immersing the bricks for 6
(Six) hours in water before use in
Superstructure including splays cutting,
circular moulding, corbelling, chamfering
and similar such type of works, watering
and curing etc. including cost, conveyance,
loading, unloading, royalties and taxes of
all materials, cost of all labour, scaffolding,
sundries, T&P required for the works etc.
complete in all respect as directed by the
Engineer-in-charge
Half brick work with Fly Ash brick masonry
in cement mortar (1:4) in super structure
having a crushing strength of not less than
75 kg./sqcm with dimensional tolerance ±
2% including splays cutting circular
moulding chamfering and corbelling and
similar such type of works with all
12 12 necessary projections watering and curing 0 0.00 0.00 0.00
after immersing the bricks in water at least
for six hours before use including cost,
conveyance, royalties and taxes of all
materials with all labour,labour cess and T
& P required for the work complete in all
respect as per direction of Engineer-in-
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Providing, lifting, hoisting and laying
Reinforced cement concrete of M-20 grade
as per approved designs and drawings
having a minimum compressive strength
(in work test) 200 Kg. / Square cm. in 15
cm. cubes at 28 days after mixing and test
conducted in accordance with I.S. 516
using 12 mm. to 20 mm. size black hard
crushed broken granite stone chips and
screened and washed sharp sand for
mortar of approved quality from approved
quarry, washed and cleaned ( 20mm. size
chips not to exceeds 25 % ) to be mixed in
concrete mixture with Portland slag
cement (PSC) including hoisting, lowering,
laying and compaction concrete by using
vibrators, watering and curing for 28 days,
centering and shuttering then after
dismantling and removing debris from the
work site and finishing the exposed surface
smooth providing grooves or beads
wherever necessary including cost,
conveyance, loading, unloading, royalties
and taxes of all materials and cost of all
labours, sundries, T & P required of the
work etc. complete in all respect as
directed by the Engineer-in-Charge. But
excluding cost and conveyance of M.S. rods
or Tor steel and binding wires and labour
charges for straightening, cutting, bending
etc. of M.S. rods or tor steel tying the grills
and placing in proper position.
17 17 b) Column up to plinth Cum 18.87 13580.62 2,56,220.17
19 19 f) Column above plinth Cum 19.87 13580.62 2,69,807.60
Cutting, straightening coiled or bent up
M.S. Rod or tor steel of including bending,
binding, welding and joining if necessary
and tying the grills and placing in position
as required for R.C.C. Work and for
providing fan hooks as required, hoisting,
lowering, laying including cost,
conveyances, taxes of M.S. Rod or tor steel
and binding wires of 18 to 20 gauge and
29 29 labour required for the work for bending, 0 0.00 0.00 0.00
binding and tying the grills in all floors
(Linear measurement will be taken and
quantity will be calculated basing on the
standard weight of B.I.S. for M.S. Rods or
tor steel only. Wastage if any, including
weight of binding wire will not be
considered for measurement) etc. complete
as per specification & direction of Engineer-
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
12mm cement plaster to out side of brick
surfaces with cement mortar of mix 1:6 (1
32 33 cement : 6 fine sand) including necessary 0 0.00 0.00 0.00
scaffolding, curing etc. all complete at all
floors and all heights.
16mm cement plaster to inside of brick
surfaces with cement mortar of mix 1:6 (1
35 37 cement : 6 fine sand) including necessary 0 0.00 0.00 0.00
scaffolding, curing etc. all complete at all
floors and all heights.
6 mm cement plaster on RCC surfaces at
ceiling/slab soffit and other locations with
cement mortar of mix 1:4 (1 cement : 4
coarse sand) including necessary
scaffolding, curing etc. all complete at all
floors and all heights.
Supplying, fitting & fixing of Granite Tiles of
minimum Above 0.40 sqm. (20mm thick) of
approved make in floors laid on 20 mm
thick cement mortar (1:4) (1
41 45 cement : 4 course sand) and filling joints 0 0.00 0.00 0.00
with slurry including cost of all materials,
labour T&P etc. required for the work all
complete incl. rubbing as per direction of
the Engineer-in-charge.
Supplying, fitting & fixing of Granite Tiles of
minimum Above 0.10 Sqm & up to 0.4 sqm
(10mm. thick) of approved make in dadoes
laid on 12 mm thick cement mortar (1:3)
43 48 (1 cement : 3 course sand) and filling joints 0 0.00 0.00 0.00
with slurry including cost of all materials,
labour T&P etc. required for the work all
complete incl. rubbing as per direction of
the Engineer-in-charge.
Supplying, fitting & fixing of 8-10 mm thick
& size of 600x600 mm vertified floor tile
of matt finish with veilcraft (VC/FT )
shield( Scratch free/stain free) with water
absorption limit between 0.08% to 3% and
conforming to IS : 15622:2006 (Group B
45 51 Ib). laid on 20 mm thick cement mortar 0 0.00 0.00 0.00
(1:4) (1 cement : 4 course sand) and filling
joints with white cement of approved
quality including cost of all materials,
labour T&P etc. required for the work all
complete as per direction of the Engineer-in-
charge (for New Work only )
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying, fitting & fixing of 8-10 mm thick
and size of 600x600 mm vertified wall tile
of in dadoes, skirting and risers of steps of
laid on 12 mm thick cement mortar (1:3)
(1 cement : 3 course sand) jointed with
slurry mixed with pigment to match the
shades of the tiles etc. complete including
cost of all materials, labour T&P etc.
required for the work all complete as per
direction of the Engineer-in-charge.
Providing and fixing seasoned sal wood
work in frames at any locations including
doors, windows,cupboard, clerestory and
other frames fixing in position including
cost of hinges, M.S. flat (30mm x 6mm)
hold fasts lugs or dash fasteners of
required dia and length as per drawing /
specification, at all floors and all heights.
Factory made 30mm/32mm flush door
shutter (Laminates both side of frame) with
51 59 all labour, iron fittings, and wooden hinged 0 0.00 0.00 0.00
cleats etc fitted and fixed complete in all
Providing & fixing of Factory fabricated
WINPLUS® Aluminium Door Systems - For
sliding windows, made from 6063 alloy and
T-6 tempered aluminium profile, in
approved shade of hybrid /purepolyster
surface coating (50-60micron Powder
Coat), mechanically mitred & jointed with
casted / aluminium extruded corner cleats
along with Sliding window Flush Lock,
Bearing Rollers , Siliconised Weather strip
and 5mm ET 125 toughened glassas infill
shall be fitted into Shutter using siliconised
microwave treated EPDM gaskets excluding
taxes of all materials and cost of all labours
required for the work etc. complete in all
respect as desired by the Engineer in
charge. Note - conveyance, T&P and
scaffolding are not included herein.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Providing and fixing factory made 2 track 2
panel KOMMERLING uPVC white colour
sliding window comprising of uPVC multi-
chambered frame having section Frame
58mm x 49mm, Window sash: 37mm x
61mm, made out of lead free green profiles
with corners fusion welded, fully reinforced
with Galvanized steel 1.5/2.0 mm. The
windows profile should fulfill the
requirements of Viny 2010. The physical
properties of the profiles like Vicat
softening temperature, density, tensile
strength, hardness, weatherability, impact
strength and Modulus of Elasticity should
be tested in accordance with ASTM/DIN-
ISO standards and the thermal conductivity
as per IS standards. The window
comprising of uPVC extruded glazing beads
of appropriate dimension, EPDM gasket, G.I
fasteners 100 x 8 mm size for fixing frame
to finished wall, plastic packers, plastic
caps and necessary stainless steel screws
etc. After fixing frame the gap between
frame and adjacent finished wall shall be
filled with weather proof silicon sealant
over backer rod of required size. The sash
will be fitted with 5mm clear glass ( float
).complete in all respect as per
specification and direction of the Engineer
in Charge. etc. complete
Supplying and Fixing of M.S. Grills,
M.S.Doors, M.S. Gate etc including
cost,conveyance of all
materials,priming,and labour for fitting
fixing etc.complete as per the instruction of
Engineer-in-Charge
Priming one coat with wall cement primer
(water bound) to make an even finished
surface in all floors and heights to wall
surface of approved make and shade
including sand papering, applying putty
wherever necessary & cost of scaffolding,
staging charges with cost, conveyance,
taxes of all materials, cost of all
labour,labour cess T&P etc. complete as per
the direction of the Engineer-in-charge.
Painting two coats with approved anti-
fungal weather seal paints (ISI) of
approved colour, shade on wall surface
over a coat of wall primer(ISI) water bound
64 74 including sand papering, polishing the 0 0.00 0.00 0.00
surface, cost, conveyances of all materials
and cost of all labour,labour cess with T&P
etc, complete as per specification &
direction of Engineer-in-charge.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Finishing plastered surfaces of walls with
cement based wall putty (Water based) of
approved make and finishing the surface
smooth and even by sand papering to
receive painting in walls, at all heights with
staging wherever necessary with cost,
conveyance, taxes of all materials, cost of
all labour,labourcess, all T&P etc. required
for the work complete in all respect as per
the direction of the Engineer-in-charge.
Painting two coats with approved plastic
emulsion paint over a coat of wall primer
of make Dulux / Berger / Asian to inside
surface of walls finished with Acrylic Wall
putty (water based) of makeand finished
smooth & even surface to receive painting
using roller to the final coat including cost
of scaffolding staging charges with cost,
conveyances, taxes of all materials, cost of
labour, T&P required for the work etc.
complete for all floors as per specification &
direction of the Engineer-in-charge.
Note :- Sample of Paint & Primer shall be
approved before procurement and use.
Painting two coats with approved Enamel
73 86 Paint on wood work over a coat of Wood 0 0.00 0.00 0.00
Primer in Ground Floor
Painting two coats with approved Enamel
Paint on Steel work in Ground Floor
77 91 Terrace floor Sqm 4.01 173.22 694.63
Supplying, fitting and fixing of Stainless
steel of 304 grade in hand ralling using
50mm dia of 2mm thick circular pipe with
Balustrade of size 32mm X 32mm X 2mm
@ 0.90mtr. C/C and stainless square pipe
78 93 bracing of size 32mm X 32mm X 2mm in 3 0 0.00 0.00 0.00
rows in stair case as per approved design
and specification, buffing, polishing etc with
cost, conveyance, taxes, all materials,
labour, T&P etc. required for the complete
in all respect.
2.5 cm thick grading concrete (1:2:2) on
roof slab with 6.7mm & down grades size
hard granite crusher broken chips on new
work in Ground Floor
82 0 Sub-Total of Civil Works 0 0.00 0.00 1,39,91,237.45
83 0 Plumbing Works 0 0.00 0.00 0.00
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials , labour, T&P and
fixing rotational moulded polyethylene
cylindrical vertical water storage tanks
conforming to IS:12701/1996 including
cutting holes through the tank and fixing
mild steel tubes and fittings and providing
extra sockets and jam nuts, fixing ball
valve etc. including hoisting upto a height
of 5 metres above ground level and placing
the tank to the required position and
providing 5.40 mtr. lengthx0.25 mtr width
KB brickwork in cement mortar (1:6) of
0.46m height in staging and 0.13mtr thick
circular protection wall of 0.46mtr height to
support the tank,12mm thick cement
plaster in cement mortar (1:6) over brick
work, RCC slab of size 1.60mX1.60m and
0.10m thick ,RCC beam of 0.25mx0.30m
and 3.40m average length in cement
concrete (1:2:4) using 12mm size crusher
broken hard black granite chips and
required steel reinforcement including
centering and shuttering,watering,curing
,cost of all materials,conveyance of all
materials to worksite , payment of royalty,
all taxes etc.all complete as per approved
drawing , P.H. specification and direction of
Engineer-in-charge
2000 liters capacity PVC water storage
supplying all materials, labour, T&P and
cutting holes through existing brick work
including making good the damages in
cement mortar (1:4) for taking G.I. Pipes
and fittings/ P.V.C. pipes and fittings
including watering, curing, cost &
conveyance of all materials to worksite,
payment of royality, taxes etc. all
complete as per direction of Engineer-in-
Supplying all materials , labour, T&P and
cutting holes in RCC floors and roofs upto
19cm thick for passing P.V.C pipes and G.I
fittings etc. , and repairing the holes after
87 4 insertion of pipe etc. with cement concrete Each 12.00 187.74 2,252.86
(1:2:4) including finishing complete so as
to make it leak-proof as per P.H.
specification and direction of Engineer-in-
Supplying all materials, labour, T&P and
cutting grooves in pucca floors and walls for
taking G.I./P.V.C. pipes and making good
the damages including watering , curing ,
cost & conveyance of all materials to
worksite, payment of royality, taxes etc all
complete as per direction of the Engineer-in-
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and
fixing vitreous china water closet, squatting
pan (Indian type W.C pan/Orissa pattern
squatting pan) duly embedded in cement
concrete (1:5:10) using 4cm size hard
granite metal including fixing a pair of
vitreous china 250mm x 130mm x30mm
footrest, fixing 100mm dia HCI 'p' or 's'
89 1 trap (with/without 50mm dia horn) for 0 0.00 0.00 0.00
water colset squatting pan including
jointing the trap with pan in cement mortar
(1:1) cutting the floor and mending good
the damages , cost & conveyance of all
materials to worksite, payment of royality ,
taxes etc. all complete as per P.H
specification and direction of the Engineer-
90 1 580mm size Orissa pan Each 4.00 2940.80 11,763.18
Supplying all materials , labour, T&P and
cutting holes through existing brick or
laterite masonry wall for taking U-PVC
91 1 pipes and fittings including making good Each 30.00 210.28 6,308.28
the damages etc. all complete as per P.H.
specification and direction of Engineer-in-
Supplying all materials , labour, T&P and
cutting of RCC chajja for taking HCI or U-
PVC pipe and fittings including making good
the damages etc. all complete as per P.H.
specification and direction of Engineer-in-
Supplying all materials labour T&P filling
93 1 sand in lavatories well watered and 0 0.00 0.00 0.00
rammed including lead of materials to work
Supplying all materials, labour, T&P and
providing cement concrete ( 1:2:4 ) with
12mm size crusher broken hard black
granite chips including watering,
95 1 curing,cost of all materials, conveyance of 0 0.00 0.00 0.00
all materials to work site with payment of
royalty, all taxes etc all complete as per
P.W.D specification and direction of
Engineer-in-charge
Supplying all materials, labour, T&P and
providing and fixing ceramic tiles in floors,
treads or steps and landing on 25mm thick
bed of cement mortar (1:1) ( 1 cement : 1
sand ) jointed with neat cement slurry
mixed with pigment to match the shades of
the tiles including watering, curing,cost of
97 1 all materials, conveyance of all materials to 0 0.00 0.00 0.00
work site , payment of royalty, all taxes etc
all complete as per P.W.D specification and
direction of Engineer-in-charge ( ceramic
floor tiles of premium grade having
thickness 7mm to 8mm conforming to IS
13755 of size 30cmx30cm to be pre-
approved by the Engineer-in-charge )
99 1 Ground floor Washrooms Sqm 44.27 1418.01 62,775.13
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials,labour,T&P and
providing 12mm thick cement plaster(1:4)
on brick work including
watering,curing,cost of all materials,
conveyance of all materials to
worksite,payment of royalty,all taxes
etc.all complete as per PWD specification
and direction of the Engineer-in-charge.
Ground floor - (Qnty same as Wall Tiles in
Supplying all materials, labour, T&P and
providing and fixing porcelain glazed tiles in
dado skirting on 12mm thick cement
plaster (1:3) jointed with neat cement
slurry mixed with pigment to match the
shades of the tiles including watering,
curing,cost of all materials, conveyance of
102 1 all materials to work site , payment of 0 0.00 0.00 0.00
royalty, all taxes etc all complete as per
P.W.D specification and direction of
Engineer-in-charge( ceramic wall tiles of
premium grade having thickness 6.5mm to
6.7mm conforming to IS 13753 of size
30cmx45cm to be pre-approved by the
Engineer-in-charge )
Providing fitting, fixing of Aluminium door
with anodized AL. door section of 9202 as
vertical member,9201 as top and 9200 as
middle bottom member with frame section
105 1 No. 9221 and tapered clip no. 4660 and the Sqm 24.57 6065.64 1,49,032.69
frame to be completed by means of jointing
angle No. 1855 Including all Cost of Labour.
T&P hire charges of drilling machine. labour
charges etc. complete.
Supplying all materials, labour, T&P and
laying in trenches (to level or slope)
unplasticized P.V.C. pipe conforming to IS
4985/2000 of the following out side dia for
class- 3 (0.60mpa ) including jointing with
supply of approved solvent cement by non-
heat application method/as per
106 1 manufacture's specification, provoding and 0 0.00 0.00 0.00
laying in trench cement concrete (1:4:8)
with 40mm size hard granite metal in the
type C-1 standard bedding surrounding or
encasing including concrete for bedding and
curing etc all complete as per P.H.
specification and direction of the Engineer
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials ,labour ,T&P and
constructing Inspection Chamber of inside
size 760mmx760mmx460mm with cement
concrete (1:3:6) using 40mm size crusher
broken hard black granite metal on bed ,
KB brick work in cement mortar (1:6) in
foundation and plinth, moulding and
shaping the channel inside and benching
with cement concrete (1:2:4) using 12mm
size crusher broken hard black granite
chips, 12mm thick cement plaster (1:3)
with cement punning to inside, cement
flush pointing (1:3) to outside, R.C.C cover
slab (1:2:4) using 12mm size crusher
broken hard black granite chips with R.C.C
man hole cover, earth work in excavation in
all kinds of soil and refilling the cavity
around the chamber including
watering,curing,cost of all materials,
conveyance of all materials to worksite,
payment of royalty,all taxes etc.all
complete as per approved drawing, P.H
specification and direction of Engineer-in-
Inside size 76cmx76cmx46cm with 18” dia
Supplying all materials labor T&P and
constructing MH chamber of sizes earth
work in excavation in all kinds of soil
CC(1:1:8) with black granite chips size
46mm brick work with K.B. brick having
crossing strength not less than 75 Kg /CM2
inside MH chamber over benching with
cement slush pointing (1:3)outside the MH
chamber providing painting MS or CI step
iron RCC(roof of slab with CC(1:2:4)with
black granite chips size 12mm bending
binding tying the grills placing of the
reinforcement providing RCC color of
required size refilling the cavity around the
MH chamber with excavated earth including
channeling the bed of MH etc all complete
as per PH specification.
MH size 0.91m x 0.91 m with 0.45 m (18”
dia RCC Cover )
Supplying all materials labour T&P and
constructing 1.40m dia x 2.00 m deep soak
way pit with dry brick having crossing
strength not less than 75Kg/CM2 to
99Kg/CM2 in CM(1:6) for the remaining
0.4572mm height of wall at top
CC(1:3)inside and outside inside fill with
dry brick khoa size 38mm ,CM thick RCC
perforated slab to a height of 1.9012m from
bottom covered by means of 50mmthick
RCC wall cover in pieces filled with iron
plugs including earth work in excavation
refilling of cavity around the pit and
painting the iron works complete as per
PHD design and specification including
carriage of all materials to site.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials ,labour ,T&P and
constructing gully trap chamber of inside
size 250mmx250mm with 8cm thick RCC
precast cover slab in cement concrete
(1:2:4) mix using 12mm size crusher
broken HG chips, foundation concrete
(1:4:8) using 40mm size crusher broken
HG metal on bed and around trap, KB brick
work in cement mortar (1:6) in foundation
and plinth and inside 12mm thick cement
plastering (1:3) finished with a floating
coat of neat cement including fixing
100mmx100mm size HCI gully trap,
150mmX150mm size CI grating etc.all
complete as per drawing, specification and
direction of Engineer-in-charge
115 1 2 no 50 users RCC septic tank 0 0.00 0.00 0.00
Earth work in excavation of foundation in all
kinds of soil within 50m initial lead and
1.5m initial lift including rough dressing &
116 1 breaking clods to maximum 5cm to 7cm Cum 55.89 249.40 13,939.23
and laying in layers not exceeding 0.30m in
depth and as per direction of the Engineer-
Extra lifts of 1.50 mtr or part thereof over
the initial lift of 1.5 mtr in all kinds of
embankments and road works and ordinary
earthwork in general.
Supplying all materials, labour, T&P and
providing shoring and shuttering foundation
118 1 trenches, pits etc with close wooden planks Sqm 91.58 320.61 29,361.10
or sheets shuttering etc all complete as per
direction of the Engineer in charge.
Supplying all materials, labour, T&P and
filling in foundation and plinth with sand
well watered and rammed including
conveyance of all materials to worksite,
payment of royalty, taxes etc.all complete
as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and
providing cement concrete (1:3:6) with
4cm size hard granite metal including
120 1 watering, curing, conveyance of all Cum 6.16 5515.79 33,977.28
materials to worksite, payment of royalty,
taxes etc all complete as per specification
and direction of the Engineer in charge
Supplying all materials, labour, T&P and
providing cement concrete (1:1.5:3) with
12mm size hard broken granite chips for
R.C.C works including hoisting, laying,
watering, curing, conveyance of all
materials to worksite, payment of royalty,
taxes etc all complete as per specification
and direction of the Engineer in charge
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and
providing M.S reinforcement for R.C.C work
including cutting, bending, binding, and
tying the grills and placing in position
122 1 including cost of binding wire 18 to 20 Qntl 32.70 10156.97 3,32,132.85
gauge, conveyance of all materials to
worksite, payment of royalty, taxes etc all
complete as per specification and direction
of the Engineer in charge
Supplying all materials, labour, T&P and
providing rigid and smooth centering and
shuttering for R.C.C works including false
work and dismantling them after casting
including conveyance of all materials to
worksite, payment of royalty, taxes etc all
complete as per specification and direction
of the Engineer in charge
R.C.C floor and roof slabs, landings,
124 1 balconies, projecting sunshades and chajjas Sqm 16.00 515.54 8,248.67
up to 4.30 mt height
R.C.C beams,columns,girder and bressmer
Supplying all materials, labour, T&P and
providing 6mm thick cement plaster (1:4)
on RCC work including watering, curing,
126 1 conveyance of all materials to worksite, Sqm 79.36 188.56 14,964.44
payment of royalty, taxes etc all complete
as per specification and direction of the
Engineer in charge
Supplying all materials, labour, T&P and
providing cement punning including
watering, curing, conveyance of all
materials to worksite, payment of royalty,
taxes etc all complete as per specification
and direction of the Engineer in charge
Supplying all materials, labour, T&P and
providing 12mm thick cement plaster (1:4)
on brickwork including watering, curing,
128 1 conveyance of all materials to worksite, Sqm 10.56 182.43 1,926.44
payment of royalty, taxes etc all complete
as per specification and direction of the
Engineer in charge
Supplying all materials, labour, T&P and
providing brick work with K.B bricks having
crushing strength not less than 75kg/cm²
with dimensional tolerance ± 8 percent in
129 1 cement mortar (1:4) including watering, Cum 1.20 5157.78 6,189.34
curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all
complete as per specification and direction
of the Engineer in charge
Supplying all materials, labour, T&P and
making MS step iron in 20mm diameter MS
steel bars and fixing into walls of man
130 1 hole/septic tank duly embedded in cement Each 16.00 297.12 4,753.98
concrete (1:3:6) complete as per
specification and direction of the Engineer
Filling in foundation and plinth with
excavated materials, moorum including
watering and ramming as directed by the
Engineer in charge
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Pump House of size 8'-0''x8'-0'' (Internal)
Earth work in excavation of foundation in all
kinds of soil with in 1.5m initial lift
including dressing and leveling of bed and
breaking the clods and the excavated
materials with in 50m initial lead as per
direction of Engineer in charge.
Supplying all labor T&P & filling sand in
foundation and plinth with well watered &
rammed etc. all complete as per direction
Supplying all materials, labor T&P providing
CC (1:4:8) with 4 cm HG metal including
watering curing lead of all materials to site
Supplying all materials labour T&P and
providing 1st class Fly Ash brick work in CM
(1:6) in F&P including watering and curing
and lead of materials to site.
Supplying all materials, labour, T&P &
providing 2.5cm thick D.P.C. flooring with
cement concrete (1:2:4) 12mm hard
137 1 broken granite chips including conveyance Sqm 4.03 344.09 1,386.67
of all materials, watering curing payment of
royalty taxes etc. all complete as per
direction of Engineer-in-charge.
Supplying all materials, labor T&P providing
CC (1:2:4) with 4 cm HG metal including
watering curing lead of all materials to site
Supplying all materials labour T&P and
providing 1st class Fly Ash brick work in CM
(1:6) in Super Structure including watering
and curing and lead of materials to site.
Providing C.C. (1:1½:3) with 12mm size
hard granite chips of RCC work including
hoisting and laying and curing with lead of
all materials to site.
Supplying all materials, T&P and providing
MS reinforcement for RCC work including
141 1 cutting, bending, binding and tying the Qtl 1.22 10156.97 12,391.50
grills and placing in position including cost
of binding wire 18 to 20 gauges.
Supplying all materials labour T&P and
providing 12mm thick C.P (1:6) including
watering curing and conveyance of all
materials to site.
Rigid & smooth centering & sheltering for
RCC work including falls work & dismantling
than after casting including cost of
materials in ground floor.
RCC floor, roof slab chhaja up to 4.430 m
Supplying all materials, labour, T&P &
providing 2.5cm thick A.S. flooring with
cement concrete (1:2:4) 12mm hard
145 1 broken granite chips including conveyance Sqm 5.76 356.71 2,054.67
of all materials, watering curing payment of
royalty taxes etc. all complete as per
direction of Engineer-in-charge.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all labor T&P & filling foundation
and plinth with excavated materials well
watered & rammed etc. all complete as per
direction of EIC.
Supplying all materials labour T&P
147 1 providing on two coats of white washing 0 0.00 0.00 0.00
148 1 Same as Plaster Area Sqm 62.15 14.63 909.38
Supplying fitting, fixing in position angle
iron window frame made out of 35mm x
35mm x 5mm, M.S. angle with required
nos. of hinges and steel shutter made out
of 25mm x 25mm x3mm, M.S. angle fitted
with 20 gauge G.P. sheet/ steel plate and
welded with tower bolt, handle hold fast &
149 1 M.S. flat of 19mm x 3mm & welded with K.G. 103.00 101.57 10,462.16
entire grill on windows and one coat of red
oxide primer and fixing with C.C. (1:3:6)
using 12mm size HBG CB Chips and making
good to the damages and finishing the
exposed surface smooth with watering
curing etc. as per direction of the Engineer-
Supplying all materials, labour, T&P and
providing and fixing to wall or ceiling and
floor PVC pipes conforming to ASTM-D-
1785/89 of the following nominal bore, tube
150 1 fittings and clamps including making the 0 0.00 0.00 0.00
wall good. ceiling and floor, testing all
complete as per specification and direction
of the Engineer in
charge.(Oriplast/Supreme/Finolex)
151 1 20mm dia PVC ASTM pipe (sch-80) Mtrs. 50.00 160.36 8,018.10
152 1 25mm dia PVC ASTM pipe (sch-80) Mtrs. 150.00 220.54 33,081.30
153 1 32mm dia PVC ASTM pipe (sch-80) Mtrs. 80.00 289.93 23,194.08
154 1 40mm dia PVC ASTM pipe (sch-80) Mtrs. 75.00 381.26 28,594.35
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes conforming to
IS:15778, having thermal stability for hot &
cold water supply, including all CPVC plain
& brass threaded fittings including fixing
the pipe with clamps at 1.00 m spacing.
This includes jointing of pipes & fittings
with one step CPVC solvent cement and
testing of joints complete as per direction
of Engineer-in-Charge
Supplying all materials, labour T&P and
fitting and fixing brass/CP fittings of the
following nominal bore with supply of all
joiniting materials including cost &
conveyance of all materials to worksite,
payment of taxes etc. all complete as per
P.H specification and direction of the
Engineer-in-charge.
158 1 15mm dia CP angle stop cock Each 26.00 1016.33 26,424.68
159 1 15mm dia CP two in one bib cock Each 6.00 1480.90 8,885.40
160 1 15mm dia CP Bib cock Each 6.00 1306.73 7,840.39
161 1 15mm dia CP Long Body Bib cock Each 16.00 1713.24 27,411.87
162 1 15 mm dia CP Bib cock Elbow Action Each 10.00 2700.43 27,004.30
163 1 20mm dia CP concealed stop cock Each 4.00 894.56 3,578.23
164 1 25mm dia brass full way valve Each 8.00 1094.21 8,753.71
32mm dia brass full way valve
166 1 40mm dia brass full way valve Each 4.00 2034.32 8,137.28
167 1 15mm dia CP Health faucet Each 6.00 1945.47 11,672.80
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
168 1 15mm CP Extension piece Each 64.00 69.97 4,478.34
170 1 15mm size C.P. flange Each 64.00 47.55 3,043.46
Supplying all materials, labour, T&P and
fitting and fixing U-PVC SWR soil waste
ventilating pipes and fittings of the
following outside diameter conforming to
ISI No 13592/1992 to walls with nails,
bobbins and wooden plugs or laying in
trenches including jointing with supply of
171 1 approved rubber lubricant by non-heat 0 0.00 0.00 0.00
application method/as per manufacturer's
specification, testing, earthwork in
excavation in all kinds of soil and refilling of
trenches , cost & conveyance of all
materials to worksite, payment of taxes
etc. all complete as per P.H specification
and direction of the Engineer-in-charge.
110mm U-PVC ‘P’ Trap
174 1 110mm U-PVC door bend Each 20.00 273.76 5,475.20
110mm U-PVC Plain bend
176 1 110mm U-PVC Plain tee Each 10.00 380.79 3,807.86
178 1 110mm U-PVC offset without ear Each 20.00 480.73 9,614.64
100mm U-PVC Cowl
110mm U-PVC Socket
Supplying all materials, labour, T&P and
fixing the following vitreous china Wash
Down Water Closet (European type W.C
pan) with integral ‘P’or ‘S’ trap to the floor
with wooden plug and chromium plated
pedestal screws including jointing the trap
with soil pipe in cement mortar (1:1), fixing
183 1 plastic seat and cover for wash down water Each 1.00 14170.27 14,170.27
closet with chromium plated brass hinges
and rubber buffers including polishing etc
all complete as per specification and
direction of the Engineer in charge.SINGLE
PIECE-WATER COLSET P TRAP - LYS-WHT-
Supplying all materials, labour, T&P and
fixing the following vitreous china Wash
Down Water Closet(European type W.C.
pan)with integral 'p' or 's' trap to the floor
with wooden plug and chromium plated
pedestal screws including jointing the trap
with soil pipe in cement mortar (1:1) fixing
plastic seat and cover for wash down water
closet with chromium plated brass hinges
and rubber buffers including polishing , cost
& conveyance of all materials to worksite,
payment of royality, taxes etc. all
complete as per P.H specification and
direction of the Engineer-in-charge
European water closet with 's' trap plain
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour T&P and and
fixing 12.50 liters/10 liters capacity low
level flushing cistern with a pair of cast iron
or M.S. brackets complete with fittings
such as siphonic arrangements 15mm
nominal size brass/pvc ball valve with
polythene float CP brass handle,unions and
couplings for connection with inlet, outlet
and overflow pipes, 32mm dia CP long flush
bend, 15mm dia pvc inlet connection pipe
including cutting holes and making good
the same and connecting the flush bend
with cistern and closet and connceting the
inlet pipe with suupply main , cost &
conveyance of all materials to worksite,
payment of taxes etc. all complete as per
P.H specification and direction of the
Engineer-in-charge
10 ltr. Capacity pvc L.L. cistern with 32mm.
Dia CP long flush bend
Supplying all materials, labour T&P and
fixing wash basins with hole for pillar taps
with cast iron or M.S.brackets painted
white including cutting holes in walls and
making good the damages with supply of
wooden plugs, screws and cement etc,
fixing pedestal for wash basin recessed at
the back for the reception of pipes and
fittings, fixing PVC waste pipe of 32mm
nominal diameter for wash basin including
brass check nut complete, fixing pillar taps
capstan head screw down high pressure
lettered 'Hot' and 'Cold' with long screws,
shanks and back nuts of 15mm dia nominal
bore, fixing 15mm dia PVC inlet connection
pipe and making connection with pillar
cocks and supply mains for wash basin,
fixing 32mm dia CP brass waste, cost &
conveyance of all materials to worksite,
payment of taxes etc. all complete as
perP.H specification and direction of the
Engineer-in-charge
550mmx400mm W.H.basin with 15mm dia
C.P.pillar cock with PEDESTRAL
Supplying all materials, labour, T&P for
fitting & fixing Kitchen sink of all standard
sizes with a pair of bracket, C.P. waste,
190 1 trap & P.V.C. waste pipe & painting Each 4.00 5789.08 23,156.32
brackets including supply of cement
concrete & mortar etc. all complete. 24” x
Supplying all materials, labour, T&P and
fixing standard sized CP towel rail complete
191 1 with CP brass brackets fixed to wooden 0 0.00 0.00 0.00
plugs with CP screws as per specification
and direction of the Engineer in charge
192 1 25mmx600mm long CP towel rail Each 11.00 824.70 9,071.72
Supplying all materials, labour, T&P and
fixing standard sized glass-shelf with CP
brass brackets and guard rail complete
fixed to wooden plugs with CP screws as
per specification and direction of Engineer
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
195 1 600mmx125mm plate glass shelf Each 14.00 707.29 9,902.09
Supplying all materials, labour, T&P and
fixing mirror of superior glass mounted on
6mm.thick A.C. sheet or ply wood sheet
and fixed to wooden plugs with CP screws
and washers complete as per specification
and direction of Engineer in charge.
600mmx450mm size B.E mirror (swivelled
Supplying all materials, labour, T&P and
fixing CP soap holder complete with CP
198 1 brass brackets fixed to wooden plugs with 0 0.00 0.00 0.00
CP screws as per specification and direction
of the Engineer in charge
199 1 CP soap holder Each 11.00 209.92 2,309.14
Supplying all materials labor T&P & Fitting
& fixing CP shower with rim with supply of
red lead and yarn nail complete as per
direction of Engineer in charge.
Supplying all materials, labour, T&P and
providing fitting and fixing (Aqua guard)
pure chill 120 PSS UV of size 750 x 570 x
1350mm hight with water storage capacity
202 1 120 liter's along with 3 noa of faucets 2 for 0 0.00 0.00 0.00
cold water and 1 for normal water including
a flow of 1.5 ltr per munite etc all complete
as per approved drawing , specification and
direction of the Engineer in charge
203 1 Aqua guard pure Chill 120 PSS UV Each 2.00 119528.10 2,39,056.20
Construction of 1 nos production well
including scientific source finding through
consolidated and unconsolidated rock with
down the ODEX drilling rig with PVC, GI,
MS pipe and installation of submersible
pump set with all accessories.
Labour for drilling a perfectly vertical bore
hole of specified dia for a specified depth
below ground level through consolidated
and unconsolidated rock with combination
drilling rig as required to suit the site
condition as per the direction of Engineer-in-
charge including supply of own rig with its
accessories, tools and plant and
consumables etc. for lowering of 200mm
/150mm dia M.S. Pipe / PVC casing fitted
205 1 with socket and with or without well screen 0 0.00 0.00 0.00
as per the necessity for sub-medium hard
and boulder formation (M.S./PVC casing
pipe if required to prevent collapse of over
burden is to be provided by contractor
including lowering and withdrawing after
completion of the tube well) 200mm dia x
400mm dia in over burden position
inlcluding packing of gravel supplied by
Contractor for 400mm bore only etc as per
direction of Engineer incharge.
206 1 Drilling for 200mm dia bore 0 0.00 0.00 0.00
209 1 Drilling for 150mm dia bore 0 0.00 0.00 0.00
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Lowering the following size of G.I. / PVC /
M.S. housing pipe with or without slotted
pipe as per the necessity for ground level
upto 45 mtr depth and fitted and fixed up
perfectly vertical position including cutting
211 1 and threading of pipes and slotted pipes 0 0.00 0.00 0.00
and supplying and fixing all jointing
materials, tools and plants etc all complete
and keeping the top of the casing pipe
threaded including plugging tube wells to
prevent entry of foreign materials.
Lowering 200mm dia M.S.ERW pipe casing
cleaning and developing the tube well with
supply of compressor worked till clear and
adequate discharge in obtained from the
tube well including supply and use of all
necessary equipment and labour as per
direction of Engineer-in-charge.
Supplying all labour, materials and T&P for
providing sanitary sealing by cement
concrete grouting of annular space around
216 1 M.S. casing pipe uptp 5 mtr below groun No. 1.00 1902.11 1,902.11
dlevel to plug the bore hole excluding cost
of cement etc all complete as per direction
Supplying all materials, labour, T&P and
providing, fitting and fixing submersible
pump with squirrel cage induction type
submersible type submersible electric
motor to run on 3 phase/1 phase line
voltage ranging from 320 volt to 450 volt
conforming to IS: 8034/89 with following
specifications with suitable control panel,
jointing with GI/PVC/HDPE pipes,
electrification, testing, commissioning, trial
running, conveyance of all materials to
worksite, payment of taxes etc all complete
as per specification and direction of the
Engineer in charge
2 H.P. Single phase/ three phase 7 stage
head renge of 20 to 35 mtr with discharge
capasity 145 to 110 L.P.M With outlet dia
219 1 DOL Control panel Each 2.00 4490.49 8,980.98
220 1 40mm dia steel short piece Each 2.00 179.71 359.43
222 1 50mm size CI bracket Pair 1.00 107.73 107.73
224 1 20mm dia rigid UPVC pipes Mtr 90.00 8.14 732.78
225 1 Steel rope with cover Mtr 90.00 31.51 2,835.54
Labour charges for lowering including
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying all materials, labour, T&P and
providing and fixing to wall or ceiling and
floor HDPE pipes and pipe fittings
conforming to IS: 4984/2000 (10kgf/sqcm)
of the following nominal bore with clamps
and jointing by Fusion welding method
including testing, making good the wall,
ceiling and floor all complete as per
specification and direction of the Engineer
229 0 Sub-Total of Plumbing Works 0 0.00 0.00 34,50,672.30
230 0 Electrical Works 0 0.00 0.00 0.00
Point wiring in Recessed wirring to light
point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FRLSH/LSZH PVC
insulated copper conductor of ISI marked
20 mm dia PVC flexible non metallic conduit
FRLS type ISI marked with 6A modular
type(( falme retradant type)) switch ISI
marked , and ceiling rose ISI marked of
modular type G.I box with metallic cover
plate (both side) falme retradant type) ,
of suitable size, modular box with 1.5 sq.
Mm FRLS PVC insulated single core
231 1 multistandard copper conductor as earth 0 0.00 0.00 0.00
wire including all accessories and
connection as per direction of Engineer -in -
Charge. CATAGORY AS FOLLOWS ,complete
suitable for Office.(Maximum 02 nos point
in one circuit).All the switches & sockets
should be warrantied for a replacement
period of 10 years against defects with
ncessary test report & Warrnaty certificate
to be submitted to the department for
genuinity of product & to avail free after
sales service within warranty period for
acceptance of materials.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Group control of point in Recessed wirring
to light point/ fan point/ exhaust fan point/
call bell point with 1.5 sq.mm FRLSH/LSZH
PVC insulated copper conductor of ISI
dia PVC flexible non metallic conduit FRLS
type ISI marked with 6A modular type((
falme retradant type)) switch ISI marked
and ceiling rose ISI marked of modular
type G.I box with metallic cover plate
(both side) falme retradant type) of
suitable size, modular box with 1.5 sq. Mm
FRLS PVC insulated single core
multistandard copper conductor as earth
wire including all accessories and
connection as per direction of Engineer -in -
Charge. CATAGORY AS FOLLOWS ,complete
suitable for Office.(Maximum 02 nos point
in one circuit).All the switches & sockets
should be warrantied for a replacement
period of 10 years against defects with
ncessary test report & Warrnaty certificate
to be submitted to the department for
genuinity of product & to avail free after
sales service within warranty period for
acceptance of materials.
Supplying ,fixing of 6A Plug on the same
board in existing switch board with
complete fitting by 01 no of 6A switch &
socket (modular type)( ( falme retradant
type)) & other required accessories of ISI
marked as approved as per direction of
Engg. -in -Charge. , complete suitable for
for HOSTEL.(Maximum 02 nos point in one
circuit).All the switches & sockets should be
warrantied for a replacement period of 10
years against defects with ncessary test
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free aftersales service
within warranty period for acceptance of
Supplying,fixing of 6A Plug on the separate
board with complete fitting by 01 no of 6A
switch & socket(modular type)( ( falme
retradant type)) with suitable size modular
box & cover( falme retradant type)
including supplying of all required
accessories of ISI marked as approved as
per direction of engg-in-charge. , complete
237 1 suitable for Residence.(Maximum 02 nos Nos 66.00 597.08 39,407.28
point in one circuit).All the switches &
sockets should be warrantied for a period of
10 years against manufacturing defects
against which ncessary test report &
Warrnaty certificate to be submitted to the
department for genuinity of product & to
avail free aftersales service within warranty
period for acceptance of materials.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying,fixing of 1x16A Plug on the
separate board with complete fitting by 01
no of 16A switch & socket(modular type)(
falme retradant type)) with suitable size
modular box & cover( falme retradant type)
including supplying of all required
accessories of ISI marked as approved as
per direction of engg-in-charge.. , (For
equipement power)All the switches &
sockets should be warrantied for a
replacement period of 10 years against
defects with ncessary test report &
Warrnaty certificate to be submitted to the
department for genuinity of product & to
avail free aftersales service within warranty
period for acceptance of materials.
Receass wiring for circuit/submain wiring
with the following mentioned size PVC
FRLSH/LSZH insulated, copper conductor,
single core cable or equievalant reputed
make A catagory ISI marked as approved,
in recessed PVC conduit Heavy duty FRLS
239 1 of mentioned size as required as per 0 0.00 0.00 0.00
direction of Engg.-in-Charge. Ncessary test
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free after sales service
within warranty period for acceptance of
2 nos single core 1.5 sq. mm copper wire
for phase and neutral and 01 no of single
core 1.5 sq. mm copper wire for earth
continuty conductor. In 20 mm dia non
metallic heavy duty flexible conduit (LDB
to LSB/LIGHT CKT)(2X1.5+1X1.5)
2 nos single core 2.5 sq. mm copper wire
for phase and neutral and 01 no of single
core 1.5 sq. mm copper wire for earth
241 1 continuty conductor in 20 mm dia non Mtr 233.00 169.92 39,591.36
metallic heavy duty flexible conduit.(BDB
to LSB/LIGHT CKT/5A PLUG/INVERTER
POINT TO EACH QTR) (2X2.5+1X1.5)
4 nos single core 2.5 sq. mm copper wire
for phase and neutral and 02 nos of single
core 2.5 sq. mm copper wire for earth
continuty conductor .in 25 mm dia non
metallic heavy duty flexible conduit(LDB to
LSB/5A SOCKET) (4X2.5+2X2.5)
2 nos single core 4 sq. mm copper wire for
phase and neutral and 01 no of single core
1.5 sq. mm copper wire for earth continuty
conductor in 20 mm dia non metallic heavy
duty flexible conduit .(PDB to PSB/ GAYSER
POINT/AC POINT/ROOM LIGHT CONTROL
TO CORRIDOOR POINT/DG PANEL
ESSENTIAL LOAD) (2X4+1X1.5)
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
4 nos single core 4 sq. mm copper wire for
phase and neutral and 02 nos of single core
2.5 sq. mm copper wire for earth continuty
244 1 conductor in 32 mm dia non metallic heavy Mtr 35.00 287.92 10,077.20
duty flexible conduit.(PDB to PSB/GAYSER.
POINT/AC POINT/DG PANEL ACCL TO EACH
QTR ESSENTIAL LOAD) (4X4+2X2.5)
2 nos single core 6 sq. mm copper wire for
phase and neutral and 01 no of single core
2.5 sq. mm copper wire for earth continuty
conductor in 25 mm dia non metallic heavy
duty flexible conduit .(LFDB TO LBDB)
4 nos single core 6 sq. mm copper wire for
phase and neutral and 02 nos of single core
2.5 sq. mm copper wire for earth continuty
conductor in 32 mm dia non metallic
heavy duty flexible conduit.(LFDB TO
LBDB/power unit/point) (4X6+2X2.5)
4 nos single core 10 sq. mm copper wire for
phase and neutral and 02 nos of single core
4 sq. mm copper wire for earth continuty
conductorin 32 mm dia non metallic heavy
duty flexible conduit .(LFDB TO FLOOR
PANEL TO TPN BDB light ) (4X10+2X4)
Supplying and fixing 20 amps, 240 volts,
SPN, industrial type socket outlet, with 2
pole and earth metal enclosed plug top
along with 32 amps. C-series, SP MCB, in
sheet steel enclosure, on surface or in
recess, with chained metal cover for the
socket outlet, and complete with
connections, testing and commissioning
248 1 etc. as required as per direction of Engg.-in- Nos 13.00 723.34 9,403.42
Charge.. . ,All the Components should be
warrantied for a replacement period of 5
years against defects with ncessary test
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free aftersales service
within warranty period for acceptance of
Supplying and fixing following size/
modules, GI box along with modular base &
metallic cover plate (both side) plate for
modular switches in recess etc as required
as per direction of Engg.-in-Charge. MAKE-
.All the Components should be warrantied
for a replacement period of 5 years against
defects with ncessary test report &
Warrnaty certificate to be submitted to the
department for genuinity of product & to
avail free aftersales service within warranty
period for acceptance of materials.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying and fixing of following sizes of
medium class PVC FRLS conduit ISI
marked along with accessories in
253 1 surface/recess including cutting the wall 0 0.00 0.00 0.00
and making good the same in case of
recessed conduit as required as per
254 1 direction
20 MM of Engg.-in-Charge mtrs 26.00 114.46 2,975.96
Supply and fixing modular type indicator
on the existing switch box/cover .
Equievalant higher make or equievalant
reputed make & model A catagory ISI
marked as approved as required as per
direction of Engg.-in-Charge.All the
256 1 Components should be warrantied for a Nos 6.00 121.54 729.24
replacement period of 5 years against
defects with ncessary test report &
Warrnaty certificate to be submitted to the
department for genuinity of product & to
avail free aftersales service within warranty
period for acceptance of materials.
Supplying and installation of AC starter
Modular type, or equievalant reputed make
& model A catagory ISI marked as
approved coil voltage-415 Volt A.C. & O/L
range of 9-14A range on mod Box of
suitable size including modular coveras
required as per direction of Engg.-in-
257 1 Charge .All the Components should be Nos 13.00 724.52 9,418.76
warrantied for a replacement period of 5
years against defects with ncessary test
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free aftersales service
within warranty period for acceptance of
Supply and fixing CALL bell (Ding dong
type) /Buzzer on the existing switch
box/cover. .as required as per direction of
Engg.-in-Charge.All the Components should
be warrantied for a replacement period of 5
258 1 years against defects with ncessary test Nos 6.00 240.72 1,444.32
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free aftersales service
within warranty period for acceptance of
S/F of Bakelite angle holder/batten holder
of ISI marked conforming to IS-1258/1987
in place of ceiling rose as per direction of
Engg.-in-Charge .All the Components
should be warrantied for a replacement
259 1 period of 5 years against defects with EACH 21.00 70.80 1,486.80
ncessary test report & Warrnaty certificate
to be submitted to the department for
genuinity of product & to avail free
aftersales service within warranty period
for acceptance of materials.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying,fixing of Blanking plate(modular
type)( falme retradant type)) in existing
switch box(anti bactorial & falme retradant
type) including supplying of all required
accessories of ISI marked as approved as
per direction of engg-in-charge.., complete
suitable for IPH standard hospital.It should
be warrantied for a period of 10 years
against manufacturing defects against
which ncessary test report & Warrnaty
certificate to be submitted to the
department for genuinity of product & to
avail free aftersales service within warranty
period for acceptance of materials.
Sub-Head II (Light fitting Fixture & Fan)
Supplying, installation, of exhaust fan of
heavy duty 300 mm sweep of exhaust fan
in the existing wall, including fixing &
conntection as required as per direction of
Engg.-in-Charge. Replacement Warranty
will be 5 years.
Supplying, installation, testing and
commssioning of 1400 mm sweep
white/milky colour ceiling fan including
wiring the down rod of standard length
(upto 30 cm) with 1.5 sq mm PVC
insulated, copper conductor, single core
cable etc. as required.(With fan Regulator)
as required as per direction of Engg.-in-
Charge.Replacement Warranty will be 5
Supplying, installation, testing and
commssioning of 1200 mm sweep
white/milky colour ceiling fan including
wiring the down rod of standard length
insulated, copper conductor, single core
cable etc. as required as per direction of
Engg.-in-Charge,Replacement Warranty will
be 5 years.. .(With fan Regulator)
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying and fixing of Energy
efficient surface mounted square shape 18
W LED luminaire of dimension of 225x 225
x 35 mm consists of white powder coated ,
die-cast Alluminium housing with high
quality frosted diffuser for glare-free
uniform lighting distribution with wattage
not more than 20 watt and lumen output of
1500 lumens, , CRI not less than 80,CCT of
6000 degree K,THD less than 10%, with
electronic driver, internal surge protection
of 2.5 KV , L70 B50: 30000 hrs (2 yrs
warranty) and all other accessories
suitable for operation on 220 V to 240 V
supply as required as per direction of Engg.-
in-Charge. ( Make : (Make: wipro LD80-171-
60-XX-SM or similar .The luminaire should
be Replacement Warranty will be 5 years
SITC of energy efficient LED tube light
fittings with decorative alluminium batten
and LED tube light having power rating not
more than 20 watt and lumen output not
less than 2200 lumen complete with
electronic driver and all other accessories
with diffuser having 5 years warranty i/c
connection etc as required as per direction
of Engg.-in-Charge.. The luminaire should
be Replacement Warranty will be 5 years .
SITC of Sleek LED 10-12 watt mirror light
fitting with extruded polycarbonate
housing,High optically efficient
diffuser,above wash basin complete with all
accessoriesetc. directly on wall, including
267 1 connection with 1.5 sq. mm FRLS PVC Nos 6.00 861.40 5,168.40
insulated, copper conductor, single core
cable and earthing etc. as required as per
direction of Engg.-in-Charge.
The luminaire should be Replacement
Warranty will be 5 years
Supplying and fixing of Energy
efficient recess mounted LED luminaire with
white powder coated ,pressure die-cast Al
housing ,with high transmititivity,non-
yellowing PMMA diffuser, with wattage not
more than 20 watt and lumen output not
less than 2600 Lumen ( 120 lumens/watt )
of size240 x240 x 40 mm , ,CRI not less
than 80,CCT of 5700-6500 degree K,THD
less than 10%, with Non integrated isolated
driver (protects the output /secondary side
from any disturbance on the input /
primary side ensuring safe operation), all
other accessories , life : 50,000 burning
hours (5 years warranty) , Internal surge
protection of 3 KV suitable for operation on
230 V, 50 Hz supply as required as per
direction of Engg.-in-Charge. The
luminaire should be Replacement Warranty
will be 5 years.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supplying, installation, testing and
commssioning of 400 mm sweep wall fan
including wiring with 1.5 sq mm PVC
269 1 insulated, copper conductor, single core Nos 6.00 2542.90 15,257.40
cable etc. as required as required as per
direction of Engg.-in-Charge.Replacement
Warranty will be 5 years.
Supplying and fixing extra conduit down
rod of 20 cm length G.I. pipe 15 mm dia,
heavy gauge including painting etc. as
requiredas required as per direction of
(Note : More than 5 cm length shall be
rounded to the nearest 10 cm and 5 cm or
less shall be ignored)of ISI mark as
SITC of energy efficient LED 45W for
lighting from top having power rating not
more than 45 watt and lumen output not
less than 4500 lumen complete with
271 1 electronic driver and all other accessories Nos 6.00 4363.64 26,181.84
with diffuser having 2 years warranty i/c
connection etc as required as per direction
of Engg.-in-Charge. . The luminaire should
be Replacement Warranty will be 5 years .
272 1 BDBS,DB,AC DB,FLOOR PANELS,MCBS 0 0.00 0.00 0.00
Supplying and fixing of following mentioned
way, three pole/single pole and neutral,
sheet steel,double door MCB distribution
board, 415 volts/240 volts shall be as per
IEC 61439-3,integrated door earthing
system offering additional safety to the
user,High quality polyurethane Gasket,the
box and cover shall be fabricated to
withstand IK09,the DB should be properly
273 1 pre-treated with 7 tank process and duly 0 0.00 0.00 0.00
powder coated, phosphatized with powder
coated finish, on surface/recess, complete
with terminal blocks,with suitable size FR
PVC insulated copper conducter up to
terminal blocks, tinned copper busbar,
neutral busbar, earth bar, din bar. . as per
direction of Engg.-in-Charge. The
Distribution boards should be Replacement
Warranty will be 5 years
4 Way(8+12) Way TPN MCB DD DB
Horizontal Type as per IEC 61439-3
suitable for Flush mounting and Surface
mounting with 100A Copper Bus Bar for
each phase, with neutral Bus bar, Earth Bar
& Cable ties for cable management,
prefitted masking sheet, IP43-IK09 with
metal door(FOR LIGHT,POWER INDOOR,3-
PH,POWER LOAD) Warranty on DB is 2
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply and fixing of 12 way DD single pole
and neutral sheet steel MCB distribution
board 250V on surface/recess complete
with tinned copper bus bar, neutral bus
bar, earth bar, din bar, detachable gland
plate, interconnections, phosphatized and
powder painted including earthing etc. as
required (but with out MCB/ RCCB/
Isolator) (ALL LIGHT WITH
CORRIDOOR/COMMON AREA,EM LIGHT,UPS
LOAD, EM LOAD LIGHT LOAD,POWER LOAD
2+4 way MCB Enclosure DB (GLAZED
276 1 door)(only each EM. CONNECTION UPS Nos 2.00 1923.40 3,846.80
Supplying and fixing 20 amps rating, 240
volts, C series, Double poles MCB of in the
existing MCB DB complete with connections
as per direction of Engg.-in-Charge. The
MCB should be Replacement Warranty will
be 5 years .MCB should have the fault
indication system in different colour for ON,
OFF & TRIP condition or Mid trip position for
Trip conditions for easier identification of
fault.Warranty on MCB is 5 years.
Supplying and fixing 6 amps to 32 amps
rating, 240 volts, C series, single poles
MCB of Make-LEGRAND-Ekinox3 DB/
Siemens-Betaguard/ Schneider- Acti 9/L&T
(Equievalant model)/Panasonic(Equivalant
model) /ABB(Equivalant model) or
equievalant reputed make & model A
catagory ISI marked as approved. the
existing MCB DB complete with connections
as per direction of Engg.-in-Charge. The
MCB should be Replacement Warranty will
be 5 years.MCB should have the fault
indication system in different colour for ON,
OFF & TRIP condition or Mid trip position for
Trip conditions for easier identification of
fault.Warranty on MCB is 5 years.
Supplying and fixing 25Amps DP 240 volts,
RCCB,300mA in the existing MCB DB in
the existing MCB DB complete with
connections as per direction of Engg.-in-
Charge. The RCCB should be
Replacement Warranty will be 5 years
Supplying and fixing 40Amps DP 240 volts,
RCCB,300mA in the existing MCB DB in
the existing MCB DB complete with
connections as per direction of Engg.-in-
Charge. The RCCB should be Replacement
Warranty will be 5 years
Supplying and fixing 63Amps TPN 415
volts, RCCB,300mA in the existing MCB DB
in the existing MCB DB complete with
281 1 connections as per direction of Engg.-in- Nos 2.00 3114.02 6,228.04
Charge.(for power BDB & AC ODU, 8 way
TPN BDB IC).The RCCB should be
Replacement Warranty will be 5 years
282 1 (Earthing) INSTALLATION 0 0.00 0.00 0.00
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
S/IT/C of materials and installation of pipe
earth electrode made out of 50mm dia
class B G.I. pipe of 3.0 metre long with
arrangements for fitting/ termination of
G.I. flat / wire with G. I. nut bolts &
washers including cost of burnt wood
charcoal, salt, foreign soil, water pouring
arrangements, brick masonary enclosure
on top with removable RCC cover complete
with labour for excavation of pit in all kinds
of soil & rock as required and as per
direction of Engineer-in-charge.The entire
earthing system should be Replacement
Warranty will be 5 years
Providing and fixing 4 mm dia copper wire
284 1 on surface or in recess for loop earthing as Mtr 122.00 112.10 13,676.20
required.as per direction of Engg.-in-
Providing and fixing 25mm x 5 mm copper
strip on surface or in recess for connections
etc. as required as per direction of Engg.-in-
CABLING AND END TERMINATION MAIN
Supplying of one number PVC insulated
armoured and PVC sheathed XLPE property
AL. conductor power cable of 1.1 KV grade
equievalant reputed make ISI marked as
approved of following size cables as per
287 1 direction of Engg.-in-Charge. Ncessary test 0 0.00 0.00 0.00
report & Warrnaty certificate to be
submitted to the department for genuinity
of product & to avail free after sales service
within warranty period for acceptance of
4core x 16 sq mm (MDB TO FDBL/FDBU
4 core x 4 sq mm (for small power/LIGHT
290 1 3.5core x 70 sq mm (To power MDB) Mtr 155.00 450.28 69,792.81
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size not
exceeding 25 SQ. MM direct in ground in
the trench in one horizental formation
including excavation ,sand coushing
protection covering and refilling the trench
etc as required as per direction of Engg.-in -
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size not
293 1 exceeding 25 SQ. MM direct in ground in Mtr 33.00 48.38 1,596.54
the EXISTING PIPE etc as required as per
direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size
exceeding 25 SQ. MM but not exceeding
400 SQ. MM direct in ground in the
EXISTING PIPE etc as required as per
direction of Engg.-in -charge.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size not
295 1 exceeding 25 SQ. MM in open duct etc as Mtr 12.00 40.12 481.44
required as per direction of Engg.-in -
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size
296 1 exceeding 25 SQ. MM in open duct 400 SQ. Mtr 12.00 53.10 637.20
MM direct in ground in the EXISTING PIPE
etc as required as per direction of Engg.-in -
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size not
297 1 exceeding 25 SQ. MM in surface with Mtr 15.00 94.40 1,416.00
shaddle and screw etc as required as per
direction of Engg.-in -charge.
Laying of PVC Insulated PVC Seated /XLPE
power cable of 1.1 kv grade size not
298 1 exceeding 120 SQ. MM From 25 SQ. MM in Mtr 23.00 149.86 3,446.78
surface with shaddle and screw etc as
required as per direction of Engg.-in -
Supplying and making end termination with
brass compression gland and aluminium
lugs for following mentioned size cable.as
per direction of Engg.-in-Charge.
Providing,fixing and laying of fallowing dia
G.I. pipe (medium class) in ground
302 1 complete with G.I fitting incl. trenching(75 0 0.00 0.00 0.00
mm depth)and refilling as per direction of
Engg.-in-Charge.
Providing,fixing and laying of fallowing dia
HDPE pipe (medium class) in ground
304 1 complete with fitting incl. trenching(75 0 0.00 0.00 0.00
mm depth)and refilling as per direction of
Engg.-in-Charge.
S/I/T&Commissioning of LT indoor floor
mounted cubical type electrical main panel
(for both light and power circuit) made out
by 2mm CRCA steel sheet duly derusted &
pented by simens gray powder cote paint is
307 1 designed as G.A drawing as per direction Set 1.00 99774.90 99,774.90
of Engg.-in-Charge. Warrentee period of
replacement of panel & accessories must
be 5 years & compelete test certificate
must be submitted along with panel board
including component list.
In commer Main- 01 number of 125(80-
125) Amps 4P MCCB with Rom & sprader
link,25 Ka & 01 nos of40A 4P O/L
changeover switch for DG & Servo with 40A
4P MCB. .(Icu=100%Ics)with shunt
trip.with axulary for BMS
Busbar- 04 numbers of 200Amps
Electrolytic copper busbar duly sleeved by
color coaded PVC sleeve & supported by
suitable size DMC insulator.
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Busbar DG - 04 numbers of 60 Amps
Electrolytic copper busbar duly sleeved by
color coaded PVC sleeve & supported by
suitable size DMC insulator.
Out going- (i) 63A 4P MCB 6 NOS FOR
Out going- (ii) 06 nos 32A 4P MCB LIGHT
312 1 BDB AC IDU BDB/LIGHT 0 0.00 0.00 0.00
BDB,LIFT,WATER,solar,ups
Out going- (iii) 06 no 32A 2P MCB LIGHT
313 1 BDB AC IDU BDB/LIGHT 0 0.00 0.00 0.00
BDB,LIFT,WATER,solar,ups
Instrument- (i)3 numbers phase indicating
lamp with toggle switch & HRC fuse.
(ii) 01 set of digital type multifunction
voltage,current,frequency,PF,THD
HOT DIPP GALVANIZED(GC) AS PER EN-
ISO-1461 , CARBON STEEL WIRE MESH
CABLE TRAYS with internal dimensions of
size 54mm(H) x 200mm(W), of or
equievalant reputed make & model A
catogory, ISI marked as approved .The
Load bearing capacity of the Cable Trays
should be minimum of 104.8Kg/meter at
the span of 1.5Meter as per UL
specifications.(With all
accessories,bend,cover,supporter)WITH
REQUIRED SIZED JUNCTION BOX ,COVER
CONNECTOR as required as per direction
of Engg.-in-Charge. Warrentee period
oftray must be 5 years & compelete test
certificate must be submitted .
HOT DIPP GALVANIZED(GC) AS PER EN-
ISO-1461 , FLOOR RACE WAY WITH
JUNCTION with internal dimensions of
size 54mm(H) x 200mm(W), of or
equievalant reputed make ISI marked as
approved .The Load bearing capacity of the
Cable Trays should be minimum of
104.8Kg/meter at the span of 1.5Meter as
per UL specifications.(With all
accessories,bend,cover,supporter)WITH
REQUIRED SIZED JUNCTION BOX ,COVER
CONNECTOR as required.
10 KVA UPS SYSTEM(OFFICE &
EMERGENCY ROOM)
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Supply ,installation ,testing &
commissioning of 10 KVA ON LINE UPS
SYSTEM WITH suitable size battery bank,
rated of battery & isolation transformer,
IGBT based inverter system with inbuilt
isolation transformer & automatic phase
sicuency corrector of 3ph in put to 3 ph
output,415V,protection for fault by
OL,UV,EF,GF,OC,Ph. Sicuency release of
319 1 equievalant model of including supply of Set 1.00 498697.50 4,98,697.50
rack inverter stand with sufficient backup
upto 30 MINUTES with all required
accessories to complete the job including
all connection.LOAD OF CONF.) as per
direction of Engg.-in-Charge. Warrentee
period of all accessories & component &
system must be 5 years & compelete test
certificate must be submitted along with
ups including component list & SLD.
320 1 20 KVA DG WITH AMF PANEL 0 0.00 0.00 0.00
Supply, Transportation, erection, testing
and commissioning of 3 Phase, 415V, 50Hz,
water cooled multi cylinder diesel generator
set with alternator of 20 KVA with suitable
AMF panel out put contineous rating
directly coupled Engine and Alternator with
guard and mounted on a common base
plate of Robust construction and complete
without AMF panel having IP-52 protection,
Acoustic Enclosure as per CPCB norms ,
sound absorbing material, to restrict sound
level up to 75 dB up to 1 mtr distance and
as per CPCB norms etc as per following
specifications mentioned below.
A. Alternator as per direction of Engg.-in-
Charge. Warrentee period of panel must be
5 years & compelete test certificate must
be submitted along with DG set including
component list & smoke exhaust system
drawing,certified ISO 8528
ALTERNATOR:The alternator of the output
rating shall be 3 Phase, 415V, 50Hz, Ac ,
0.8 P.F. lagging at 1500 RPM. The
322 1 alternator is self excited, self regulated, 0 0.00 0.00 0.00
and shall confirm to IS: 13364 of 1992 with
regulation of +5% from no load to full load.
degree of protections shall be IP21.
ENGINE: Diesel Engine . Diesel Engine
start, developing suitable BHP output at
1500 RPM with mechanical / electronic
governing so as to enable the alternator to
give 20 KVA continuous output at 0.8 P.F.
lagging at NTP conditions. The diesel
engine shall be capable of providing 10%
O/L for 1 Hr for every 11 Hrs of continuous
323 1 running at full load. The engine with 1st 0 0.00 0.00 0.00
filling of oil and Diesel etc.
01. Exhaust pipe of required size and
length with insulation or clading.
02. Diesel tank suitable for 8 to 10 Hours
running capacity.
03. Residential Silencer.
04. SMF Batteries with leads as per the
Manufacturer standards
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
BASE PLATE: Common Base Plate of
required size for mounting of Engine
Alternator Set fabricated from MS Channerl
and vibration damping arrangement with
cushy foor mounting including paintng etc.
FOUNDATION: Suitable size Cement
Concrete (1:2:4) foundation duly plastered
and finished with neat coat Cement as
required along with smoke exhaust system
piping including base frame of structure &
lightening protection system. *It also
325 1 includes 2 nos GI pipe earthing for body 0 0.00 0.00 0.00
and 2 nos copper plate earthing for neutral,
control cable of 15mtr 2.5sqmm 6core ,
civil foundation work.
(The Manufacturing of DG set shall not in
any case be more than six months old from
the date of award of work)
AMF PANEL: Cubical, Compartmentalized,
AMF Panel Baord with all Power & Control
Contractors, Switches, Meters and other
accessories, Internal Wiring, connection,
inter-connection etc. for Trouble Free
smooth function for 20KVA DG Set
complete with Battery Charger & leads as
327 0 Sub-Total of Electrical Works 0 0.00 0.00 23,90,481.35
Supply of A,C with indoor and outdoor unit
330 1 1.5 TR high wall split A.C Each 3.00 55445.84 1,66,337.52
331 1 2 TR high wall split A.C Each 3.00 65711.84 1,97,135.52
332 1 REFRIGRANT PIPING 0 0.00 0.00 0.00
Supply,installation of hard/soft copper
refregrant piping,complete with fitting of
bends and other nesessary material to
complete the job.
334 1 1 TR to 3 TR high wall split A.C mtr 12.00 988.84 11,866.08
Supply,installation & fabrication of MS
base frame for both indoor and outdoor unit
and other nesessary material to complete
337 1 1 TR to 3 TR high wall split A.C no 16.00 1984.76 31,756.16
Supply,installation & fabrication of
Insulated drain water piping from indoor to
339 1 nearestdrain point separate to all and 0 0.00 0.00 0.00
other nesessary material to complete the
341 1 SHEET METAL WORKS 0 0.00 0.00 0.00
Supply,laying of control cable and other
nesessary material to complete the job.
344 1 For 1 TR to3 TR high wall split A.C mtr 22.00 145.14 3,193.08
345 0 Sub-Total of HVAC Works 0 0.00 0.00 4,13,139.24
346 0 Firefighting Works 0 0.00 0.00 0.00
347 1 EXTINGUISHER SYSTEM 0 0.00 0.00 0.00
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Head Description of Item Unit Qnty. Rate Amount
Portable Fire Extinguisher System
Supplying, installation, testing and
commissioning of CO2 type Fire
Extinguisher 4.5 kg capacity confirming to
IS: 2878 made from ISI marked seamless
348 2 cylinder confirming to IS: 7285, fitted with Nos 4.00 12302.68 49,210.72
ISI marked controlled valve confirming to
IS: 3224, high pressure 1mtr discharge
hose & horn complete with initial gas
charged with carrying handle & wall
mounting bracket as per direction of
Engineer-in-charge.
349 3 FIRE SIGNAGES SYSTEM 0 0.00 0.00 0.00
Providing and installing in position the
following type of sign boards made out of
3mm thick "Opaque" PVC foam board with
computer cut, PVC non-reflective self
adhesive vinyle painted foam board,
complete with mirror fasteners.
Providing and fixing the signages "Fire Exit,
Fire Exit Arrow Down,Fire Exit Arrow
Left,Fire Exit Arrow Right" of 1.5in height
letters in white with green back ground.The
size of the board shall be 25cm x 15 cm
and shall be fixed at the height of 2 mts
352 0 Sub-Total of Firefighting Works 0 0.00 0.00 55,696.00
353 0 Sub-Total of Other Works 0 0.00 0.00 0.00
354 Grand Total 2,03,01,226.34
354 Grand Total 2,03,01,226.34
Digitally signed by
Rakesh Rakesh Narayan Sinha
Narayan Sinha Date: 2023.02.08
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
5 NIT.pdf
Tender Document
3a GCC PMC Contracting Works.pdf
Tender Document
3b SCC.pdf
Tender Document
8 Milestone.pdf
Tender Document
11 BOQ SON 004 NHM.pdf
Tender Document
13 List of Approved Makes NHM Project Odisha.pdf
Tender Document
14 Scope of Work.pdf
Tender Document
Drawings Sonepur PHC.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .