Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.5 Cr+₹2.7 L (1.80%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹1.5 Cr+₹2.7 L (1.80%) | L2 | Rejected-Finance Other than being lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical Three Class below |
| 4 | Rejected-Technical ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | - | - | Rejected-Technical Adverse remarks in WLR |
| 5 | Rejected-Technical SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | - | - | Rejected-Technical Having c(vi) repairs only |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
13 Apr 2022, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
PROVISION OF AFDS SYSTEMS for BLDGS P 39 32 35 38 AND 72 72A AT NAVAL DOCKYARD MUMBAI AND PROVISION OF AFDS SYSTEMS FOR BLDGS P188 AND 198 AT NAVAL DOCKYARD MUMBAI AND PROVISION OF AFDS SYSTEM FOR BLDGS P 40 41 47 44 45 45A 67 68 AT NAVAL DOCKYARD MU
2022_MES_500421_3
8448/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
Class B and above and category c (vi)
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹2.2 L
Yes
2 May 2022
23 Mar 2022
15 Apr 2022
23 Mar 2022
13 Apr 2022
6 Apr 2022
23 Mar 2022 - 5 Apr 2022
Amount
Supplying installation, Testing & Commissioning of Microprocessor based 2 loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required and panels shall have provision of intigraton with BMS System.(UL/EN Approved) Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and as directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Microprocessor based 4 loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required and panels shall have provision of intigraton with BMS System.(UL/EN Approved) Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and as directed. Make : Honeywell/Bosch/Schneider
LANDLINE FIRE ALARM AUTO DIALER WITH sms and Memory Available To Store 10 Phone Numbers dialing facility to reach the fire brigade to get the intimation about the location of the area Builtin Emergency Speech Dialer with 8 Numbers & 1/ 2 Messages,NO/NC contacts for both fire and fault, Automatic changeover arrangement to standby supply with battery charger with low battery indication,Fault/ failure indication such as MAINS FAIL, short, open, Battery FAIL etc,Micro-Controller Based System,Both Dialling Modes Can Be Used (Pulse/Tone),Recorded Message Playback Speaker Provision Available complete all as sprcified and as directed. Make : Agni/Ravel/Atss
Supply, Installation, testing and commissioning addressable Manual call point(Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be underwritters laboratories listed, semi flush type complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Addressable monitor modules for Sprinkler Flow Switch and Door Holders complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supply fix and commissioning and test of addressable electronic hooter with built in amplifier unit with two tone generator of 100 meter range complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Analog addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC(Above Ceiling & below ceiling) complete all as specified and as directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Conventional Beam detector complete as required for hall & indoor open area complete all as specified and directed.Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes etccomplete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supply and fix fault isolator module with automatic resetting arrangement complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supply & laying PVC FRLS armoured cable 1.5sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as specified and as directed. (Note : The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it).
Supplying installation, Testing & Commissioning of Response indicator for Above ceiling detectors & Cabin Detectors complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supplying installation, Testing & Commissioning of The GUI based main network software must be capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’locations. The GUI software shall be located in control room in one of the blocks and shall monitor all the blocks panel connected with each other along with workstation complete all as specified and directed.
Supplying installation, Testing & Commissioning of Microprocessor based 6 loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved).Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode complete all as specified and directed. Make : Honeywell/Bosch/Schneider
Supply, install, Test and commissioning wall mounted Split type AC1.5 TR capacity units indoor/outdoor complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor air ioniser and Plasma filter for better indoor air quality with 5 star rating complete all as specified and directed. Note :(a) Rate of supporting brackets for outdoor unit is deemed to be included in rate quoted.
Supply and fix Single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240V complete all as specified and directed.
Supply and fixing clamping jointing copper tubing for suction line and for liquid discharge incl duly insulated with suitable insulation material including making hole in wall for passing through and making good the disturbed surface complete all as specified and directed.
Material and labour Submain wiring with 2x 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 4.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed.
Supply and fixing for Rigid non-metallic PVC conduit 20mm dia with complete of all tees, bends,elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs complete all as specified and directed.
Supply and fixing in repair MCB DB double door SPN 8 Way with 200 Amps rated copper bus bar, IP 54, IK 09 suitable for flush mounting and surface mounting complete etc all as specified and as directed.
Supply and fixing MCB SP 25 Amps,10KA, 'C' curve, type suitable for 240 volts, 10 KA including making Connection complete all as specified and directed.
Supply and fixing MCB TP 40 Amps,10KA, 'C' curve, type suitable for 240 volts, 10 KA including making Connection complete all as specified and directed.
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 16 sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as specified and directed. Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and fixing in repair sheet metal enclosure TPN DB VTPN 6 Way,415V with 250A copper busbar, double door type IP-54, IK-09 protection suitable for housing MCCB 100Amp 4 pole incl required numbers of suitable size of gland complete etc all as specified and directed by EIC. Note : DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
Supply and fixing MCCB FP 125 Amps,16KA, thermal magnetic,415volts complete all as specified and directed. Make : Legrand cat No 420016 or equivalent in Seimens/ABB/L&T
Supply and fixing MCB TP 50 Amps,10KA, 'C' curve, type suitable for 240 volts, 10 KA including making Connection complete all as specified and directed.
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
cooltech engineering services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .