| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.8 L+₹2.1 L (7.67%)Rejected-Finance 21 KAWARDHA COLLECTORATE ROAD KAWARDHA KABIRDHAM CHHATTISGARH 491995 | KABIRDHAM | CHHATTISGARH | 491995 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹28.9 L+₹2.1 L (7.86%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹30.4 L+₹3.6 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.7 L+₹5.9 L (22.1%)Rejected-Finance 103 1ST FLOOR PAYAL RIDDHI CHS PLOT NO 51 SECTOR 27 KHARGHAR RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | Ms Kailash Chandra Babulal L4 | S.S. Engineers L1 | sanjay traders L2 | SAHYOG ELECTRIC L6 | M/s Pratik Enterprise L3 | ENVIRO TECH SERVICES L7 | Manu Enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil concrete all as specified and directed. | 660 | Cum | 85 ₹56,100 | 120 ₹79,200 | 80 ₹52,800 | 80 ₹52,800 | 55 ₹36,300 Lowest | 100 ₹66,000 | 105 ₹69,300 |
| 2.00 | All as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.50m | 2.5 | Cum | 150 ₹375 | 100 ₹250 | 90 ₹225 | 200 ₹500 | 66 ₹165 Lowest | 100 ₹250 | 120 ₹300 |
| 3.00 | M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. | 1.2 | Cum | 3,500 ₹4,200 | 3,000 ₹3,600 | 2,500 ₹3,000 | 3,400 ₹4,080 | 2,000 ₹2,400 Lowest | 5,500 ₹6,600 | 3,500 ₹4,200 |
| 4.00 | M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed. | 1.1 | Cum | 2,500 ₹2,750 | 3,000 ₹3,300 | 2,000 ₹2,200 Lowest | 3,000 ₹3,300 | 2,000 ₹2,200 Lowest | 4,500 ₹4,950 | 2,500 ₹2,750 |
| 5.00 | M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges concrete all as specified and directed. | 0.8 | Cum | 3,000 ₹2,400 | 3,500 ₹2,800 | 4,200 ₹3,360 | 3,200 ₹2,560 | 1,500 ₹1,200 Lowest | 4,500 ₹3,600 | 3,000 ₹2,400 |
| 6.00 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each concrete all as specified and directed. | 412 | Cum | 30 ₹12,360 | 35 ₹14,420 | 60 ₹24,720 | 30 ₹12,360 | 60 ₹24,720 | 10 ₹4,120 Lowest | 30 ₹12,360 |
| 7.00 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point concrete all as specified and directed. | 236 | Cum | 30 ₹7,080 | 35 ₹8,260 | 60 ₹14,160 | 30 ₹7,080 | 60 ₹14,160 | 10 ₹2,360 Lowest | 30 ₹7,080 |
| 8.00 | M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables concrete all as specified and directed.
Note: Punned thickness shall be measured and paid. | 198 | Cum | 600 ₹1,18,800 | 580 ₹1,14,840 | 1,000 ₹1,98,000 | 1,000 ₹1,98,000 | 122 ₹24,156 Lowest | 850 ₹1,68,300 | 600 ₹1,18,800 |
| 9.00 | Supply and laying flyash brick modular size, laid in trenches as cable covers concrete all as specified and directed. | 19.5 | 1000 Nos | 5,000 ₹97,500 | 5,000 ₹97,500 | 6,000 ₹1,17,000 | 6,000 ₹1,17,000 | 4,500 ₹87,750 Lowest | 5,500 ₹1,07,250 | 5,000 ₹97,500 |
| 10.00 | S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall concrete all as specified and directed. | 60 | RM | 300 ₹18,000 | 280 ₹16,800 | 300 ₹18,000 | 275 ₹16,500 | 120 ₹7,200 Lowest | 450 ₹27,000 | 320 ₹19,200 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
12 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
REPAIR MAINTENANCE OF LT DISTRIBUTION SYSTEM OF MECH DEMO AMU NODE SARAGARHI PW DIV SW DIV MT AREA DANN MARG HPP OF INF AREA UNDER GE M INF SCHOOL MHOW
2025_MES_714161_1
8798/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
180 days
GARRISON ENGINEER (MIS)
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹72,000
Yes
23 Aug 2025
13 Jun 2025
14 Jul 2025
13 Jun 2025
12 Jul 2025
27 Jun 2025
Amount
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil concrete all as specified and directed.
All as per item No 1.00 above but for each additional 1.5 m or part thereof in depth beyond the first 1.50m
M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300x300 mm or chamfered on edges concrete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each concrete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point concrete all as specified and directed.
M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables concrete all as specified and directed. Note: Punned thickness shall be measured and paid.
Supply and laying flyash brick modular size, laid in trenches as cable covers concrete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall concrete all as specified and directed.
S&F in repairs Steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall concrete all as specified and directed.
M&L for dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size incl deposited at a suitable locations not more than 50 RM away complete all as specified and as directed by Engr-In- Charge.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 ,9.00 metres long, erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to view portion with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete all as specified and as directed. Note : Excavation and PCC will be measured and paid separately under respective items.
M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out the required length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge.
Note:- (A) The rate quoted shall deemed to be inclusive of the following:- (i) Necessary earth work excavation in any type of soil, returning, filling and removing extra soil. (ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacks neatly near site and same shall be re- laid after attending fault/defect. (iii) Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Required numbers of electrician and helper shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.1 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative. (B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW of genral condition of contracts. (C) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevent item.
M&L for dismantling / disconnecting / removing the faulty / burnt out overhead conductor of any type / size from insulator of HT / LT pole any type by making proper shutdown from department and removing of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all the loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion complete all as specified and directed by Engineer in charge.
NOTE: The rate quoted shall deemed to be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Required numbers of Elecrician and helper shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 1 (iv) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items.
S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer in charge.
S&F in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer in charge.
Trimming/pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed. NOTE - (a) Prior shut-down shall be obtained from concerned JE / AGE E/M before taking out the trimming work , by contractor (b) span from one pole to next pole (30 to 50 m) will be considered and measured as a job. (c) T & P such as ladder , rope, cutter , axes and safety of workmen, will be provided by the contractor
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and directed.
S&F in replacement XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 10 sqmm,4.0 core in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified & directed. Note : (a) Excavation shall be measured and paid seperately under respective items of Sch 'A' . (b) All redq lugs of suitable sizes according to laying of cable measured and paid seperately under respective items of Sch 'A' /BOQ
All as above Item No. 23.00, but 16 Sqmm 4.0 core.
All as above Item No. 23.00, but 25 Sqmm 3.5 core.
All as above Item No. 23.00, but 35 Sqmm 3.5 core.
All as above Item No. 23.00, but 50 Sqmm 3.5 core.
All as above Item No. 23.00, but 70 Sqmm 3.5 core.
All as above Item No. 23.00, but 95 Sqmm 3.5 core.
All as above Item No. 23.00, but 120 Sqmm 3.5 core.
All as above Item No. 23.00, but 185 Sqmm 3.5 core.
All as above Item No. 23.00, but 240 Sqmm 3.5 core.
S&F in repairs Aluminium lugs of size 16 sqmm
S&F in repairs Aluminium lugs of size 25 sqmm
S&F in repairs Aluminium lugs of size 35 sqmm
S&F in repairs Aluminium lugs of size 50 sqmm
S&F in repairs Aluminium lugs of size 70 sqmm
S&F in repairs Aluminium lugs of size 95 sqmm
S&F in repairs Aluminium lugs of size 120 sqmm
S&F in repairs Aluminium lugs of size 185 sqmm
S&F in repairs Aluminium lugs of size 240 sqmm
S&F in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified & directed.
All as above Item No. 33.00, but capacity of 125 amps.
S&F in replacement MCCB 3- pole, 415 volts, adjustable type 160 amps with breaking capacity 36 KA complete all as specified & directed.
All as above Item No. 35.00, but 200 amps.
All as above Item No. 35.00, but 250 amps.
All as above Item No. 35.00, but 350 amps.
All as above Item No. 35.00, but 400 amps.
S&F in replacement MCCB 4 pole, 415 volts, adjustable type 250 amps with breaking capacity 36 KA complete all as specified & directed.
All as above Item No. 40.00, but 350 amps.
All as above Item No. 40.00, but 400 amps.
S&F in replacement pin type polymer, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified & directed.
S&F in replacement shackle type polymer, vitreous, insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade complete all as specified & directed.
S&F in replacement of aluminium conductor steel re inforced, any sizes over head line conductor of any type and length as required at site including removing of foreign objects/ obstacle, if any on the over head line complete all as specified & directed.
Restringing of loose over head conductor/GI earth wire of any size and type after untyeing binding wire from insulators/cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) One job consist one span of 3-phase, 4-wire over head line. (ii) The distance of one span is approx 30 to 50m.
M&L for repalcement straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium cable complete for following sizes :-
(a) 3.5 core, 50 sq mm
(b) 3.5 core , 70 sqmm
(c) 3.5 core , 95 sqmm
(d) 3.5 core , 120 sqmm to 150 sqmm
(e) 3.5 core , 185 sqmm
M&L for painting and welding (both weldind and painting whenever required) of old exiting LT panel of any size with two coat of synthethic enemelled paint of approved colour internally and externally , after cleaning to rusted portion of panel and finishing the surfaces including one coat of primer by Skilled Painter complete all as specified and as directed. NOTE-Repairs to LT panel boards complete incl. necessary welding works to door , replacement of unserviceable hings and all drop bolt , etc.
S&F in replacement mild steel galvanised stay assembly set complete comprising of 20mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 2009 complete all as directed.
S&F in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size for HT,25X20cm size complete all as directed by Engineer-in-charge.
M&L for Painting to street light pole of steel tubular swaged/ swan neck type with two coat of aluminium paint after cleaning to rusted portion of pole and finishing the surfaces including one coat primer top to bottom, painting on cross arms/FI clamps/street liht brackets of any type including making alternative blak and yellow strip with synthethic enemelled paint up to 1.5 Mtr height from ground level & writing of pole numbers with black paint on poles all as specified and directed.
M&L for painting of LT PCC poles 09 Mtr. with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed.
Supply and Errecting LT Panel outdoor type mounted and fixed with PCC foundation , made out of MS sheet factory assembled and factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angle duly spray painted with two coat of gray synthetic enamel paint over one coat of red oxide zinc chrome primer after preparation of surface , with required civil work & wiring with copper cable of suitable size, connecting including indication lamp LED type for each phase , including 3 -Pole MCCB 200 Amps, 36 KA capacity -01 Nos, ( as incommer ) & Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 400 Amp rating - 01 No. for neutral, incl inbuilt industrial type locking arrangments , front openable incl necessary arrangments for fixing with suitable, clamps,nuts, bolts wahers etc, & incl Danger notice board , feeder marked,testing and commissioning , size 600 x600x 300 mm, complete all as specified and directed by Engr-in-Charge.
S&F in replacement cable path indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick and spot welding with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-1( using 12.5 mm graded granite stone aggregate) including providing one coat of synthetic enamlled black paint over one coat of red oxide primer and sign writing with white paint showing size of cable HT /LT complete all as specified & directed.
Cutting the Existing bituminouse road for passing of UG Cable in road crossing and making good of disturbed surgace of road to match the existing all as specified and directed by Engr-in-Charge.
M&L for Earthing (in replacement) complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.5 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.
Supply, installation, testing and commissioning out door type LT panel board ,made out of 3.15mm thick CRCA sheet , factory made, cubical type,with slanting top at leaset 10 Cm projection all around, fedder pillar type,fabricated with 50x50x6mm angle iron frame work with independent door for each feeder,busbar chamber cable tray on both side fully compartmentlized design, double door type & commen openable hinged door from rear side, floor mounting type, busbars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for connecting suitable earth strips,painting with one coat of anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), Confirming to IP 54 protection and confirming relavent IS, comprising the adequate arrangement to supply & fix the following accessories,including connecting cable glands and cable lugs,fixing of earth lead to earth terminal of panel including necessary excavation & PCC foundation complete all as specified & Directed by Engr-in-Charge. Note:- Cost of all accessories are deemed to be included in the rate quoted.
Incoming (a) Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 250 Amps, 415 volt, 36 KA - 01 No ( incoming) Make - Legrand /L&T/ABB/Schenider
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 4- pole 160 Amp, 415 volt, 25 KA - 01 Nos Make - Legrand /L&T/ABB/Schenider
(b) MCCB 4 pole 100 Amp, 415 volt, 25 KA - 02 Nos Make - Legrand /L&T/ABB/Schenider
(c) MCCB 4 pole 63 Amp, 415 volt, 16 KA - 02 Nos Make - Legrand /L&T/ABB/Schenider
(d) MCB TPN 40 Amp, 415 volt, - 2 Nos Make - Legrand /L&T/ABB/Schenider
sanjay traders (BID ID -3348237)
M/s Pratik Enterprise (BID ID -3354581)
Ms Kailash Chandra Babulal (BID ID -3344001)
Manu Enterprises (BID ID -3356226)
SAHYOG ELECTRIC (BID ID -3348213)
ENVIRO TECH SERVICES (BID ID -3348021)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .