Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹26.1 L
EMD Value
₹52,155
Closing Date
7 Oct 2023, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Corporation Limited
Giribabu M C
Replacement of damaged/worn-out ISM Beams and Channels of Belt Feeder floor, replacement of damaged Stringers, short supports of Con-16/57, Fabrication and erection of chute for clearing bunker coal at feeder floor of U-2, replacement of Con-12A/B takeup channel and guide at CHP-1
KPCL/2023-24/PS/WORK_INDENT112/CALL-4
KPCL/2023-24/PS/WORK_INDENT112/CALL-4
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer CHPM two Office RTPS Raichur
4 documents required · 0 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
The bidder should have executed at least one similar work like structural fabrication and erection works in any Thermal Power Station/coal mines/ process industry costing not less than Rs. 13.0 Lakhs (single/multiple work orders) in any year during the preceding 5 years (2018-19, 19-20, 20-21,21-22 & 2022-23). The bidder should furnish satisfactory work done Certificate issued by Chief Engineer or the competent authority (Work done of previous years shall be given weightage of 10% per year to bring them to the present price level of the financial year in which the tenders are invited).
The bidder should have carried out similar works like structural fabrication and erection works, Certificate of proof shall be provided.
The bidder should have an average minimum annual turnover of Rs.26 Lakhs in any two years during the preceding 5 financial years (2018-19, 19-20, 20-21,21-22 & 2022-23). As a proof of turn over the bidder should furnish Profit & Loss Account / balance sheet duly certified by the Chartered Accountant (Financial turnover of previous years shall be given weightage of 10% per year to bring them to the present price.
₹660
₹52,155
27 Sept 2023
27 Sept 2023
9 Oct 2023
3 Oct 2023
Replacement of damaged/worn-out ISM Beams and Channels of Belt Feeder floor, replacement of damaged Stringers, short supports of Con-16/57, Fabrication and erection of chute for clearing bunker coal at feeder floor of U-2, replacement of Con-12A/B takeup channel and guide at CHP-1
Supply of ISMB 300 x 140 mm
Supply of ISMB 200 x 100 mm
Supply of ISMB 150 x 75 mm
Supply of ISMC 200x75 mm
Supply of ISMC 100 x 50 mm
Supply of ISA 75 x 75 x 8mm
Supply of Chequered Plate 8mm
Supply of 450nb x 8mm MS ERW Pipe
Supply of 400nb x 8mm MS ERW Pipe
Supply of 125nb x 5.4mm MS ERW Pipe
Scaffolding and Dismantling of chequered plates, damaged ISM Beams and ISM channels of BF floor at SCH
Fabrication & Erection of ISM Beams, ISM Channels, IS Angles, Chequred Plates at BF floor and erection of Stringers and short supports at Con-16/57
Scaffolding & Dismantling of old damaged stringers and short supports of Con-16 & 57
Scaffolding and Dismantling of damaged Vertical gravity takeup of Con-12A/B
Fabrication and Erection of new Vertical gravity Take up for Con-12A/B
Scaffolding & Dismantling of existing chute pipe installed at Feeder floor of U-2 to zero meter.
Fabrication & Erection of 400nb New Chute pipe from Feeder Floor of U-2 to zero meter. Fabrication and erection of Chute door at feeder pipes of U-3& 4 for chokage clearing
Scaffolding & Dismantling of existing chute pipe installed at Surge Hopper Floor to Roller Screen Floor (2 Nos.) and Belt Feeder floor to First Floor of SCH (2 Nos.).
Fabrication and erection of 450nb chute pipe at Surge Hopper Floor to Roller Screen Floor (2Nos.) and Belt Feeder floor to First Floor of SCH(2 Nos.) and One Number at JT-3 First Floor to zero meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
N3 AMP 2023-24.pdf
Tender Document • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .