Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC RSD STREET HALL BAZAR AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L1 | Accepted-AOC Being L | |
| 2 | L2₹19.4 L+₹44,495.20 (2.35%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.7 L+₹75,768.70 (4.00%)Rejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
HQ 138 Works Engineers PIN-914138 C/O 56 APO
PROVN OF THREE PHASE POWER SUPPLY CONNECTION FOR STATIC OXYGEN GENERATION PLANT OF 600 LPM CAPACITY UNDER GE 865 EWS AT LEH
2022_MES_532283_1
138WE/L-35/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹40,000
Yes
22 Aug 2022
20 Jun 2022
3 Aug 2022
20 Jun 2022
27 Jul 2022
4 Jul 2022
Amount
Supply install, test and commissioning, floor mounted transformer of capacity 250 KVA, step down outdoor type 50 Hz AC, oil immersed naturally air cooled having no load voltage ration 11 KVA/433V complete with standard fittings, HT 11 KV/433 V corresponding to principal tapping, copper wound,delta connected primary side (HV side) and star connected on secondary side (LV side) in constant out put so as to alter/vary secondary voltage in steps of + 2.5% to 7.5% by means of manual of OFF LOAD taps changing arrangments, the limit of teperature rise after continous full load run as measured by oil thermometer shall not exceed 50 degree centigrade over maximun ambient temparature prevalling at site as per IS-2026 and BEE level-3 type (IS-1180), complete with following fittings and accessories including Burnt clay fly ash building bricks designation 75(Kg/Cm2) platform of size 1.75 m x 1.75 m (0.5 mtr below ground level and 1.25 mtrs above ground stone aggregate) below foundation, RCC 1.2.4 type B-1(using 20 mm graded stone aggregate) 15 cm thick flooring over platform plastering to exposed surface of masonary work incement mortar 1:4, 15 mm thick and finished with two coats of cement base paint over a coat primer including excavation returning filling in and removing all as directed including the following:- (a) Three Nos porcelain bushings HT 11 KV with brass bushing roads nuts and wahsers inside cable end box. (b) One cable terminals LV side consisting of 04 Nos porcelain bushing rods, complete with nuts and washers with two Nos cable gland suitable 3.5 core 185 Sqmm LT U/G cable. (c) Oil conservator filter type drain valve and oil level gauge. (d) Dehydrating breather with fast fill of dehydrating agent. (e) Explosion vents. (f) Thermometer pocket on tank cover. (g) Rating plate and terminal marking plate. (h) The earthing terminal two nos to tank to failat fixing of earth strip. (j) Oil level gauge. (k) Lifting lugs. (l) Oil filling hole with cap/plug with connection plate complete. (m) Air relief valve plug. (n) Initial filling of transformer oil.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric Power cables (Heave Duty) with stranded aluminium conductor,11000 Volts grade,of Size 3 Core 95 Sqmm complete.
M&L for steel tubular swaged poles complete with cost iron base plate, finial taper plug, bolts, nuts &screw as specified type 410 SP-55 (11.00 meters long) complete all as specified and directed
M&L for cable joint kit for 11 KV (Earthed) grade cable for outdoor terminaiton heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.
M&L for cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-0-310/Fe-0-410 including nuts, bolts and washers welding, drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified and directed
M&L for ACSR conductor any size drawn straight horizontal on over head lines on existing ploes including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and lenght by adding 3% extra for sag, jointing jumpers, etc complete all as specified
M&L for stay assembly complete with stay plate bow, stay rod of dia 20 mm and galvanised iron standed of size 7/4 mm and accessories as shown in electric plate no of SSR plates (loop type insulator, stay clamps, excavation and concrete shall be measured separately) complete all as specified and directed
M&L for galvanized steel wire 4 mm dia for continous earth wire complete all as specified
Supply and fixing pin type, procelain, vitreous, white, brown or green insulator, size 150 mm height, 150 mm dia for 11000 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, confirming to IS:7321-1931, complete all as specified and as directed by Engr-in-charge.
M&L for Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and soket type, white brown or green Two-in-series disc assembly for tension with clamps for conductor working pressure 11000 volts complete all as directed by Engr-in-charge.
M&L for Anti-climbing devices comprising of 2.24 mm dia galvanised steel 2 strand barbed wie with 2.00 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 meter clamped and properly secured or as ordered (clamps measured separately)
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in singla red colour and fixed with MS Clamps bolts and Nuts of approved size for HT 25 x 20 cm size
Supply and laying of tubes light grade size 80 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified
Supply and fix HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 200 Amps incl opearating rod of GI pipe 25 mm of medium grade with necessary clamps to be operated from ground level
Supply and fix lighting arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp complete
M&L for earthing of machinery/equipment installed at power house/substation, using galvanised iron strip 32 x 6 mm as earthing lead with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for earthing for poles & other machinery/equipment using 4 mm GI wire as earthing lead with using galvanised iron strip 25 x 4 mm as earthing lead with galvanised steel earth plate electrode 60 x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric Power cables (Heave Duty) 1100 Volts grade with stranded aluminium conductor of Size 300 Sqmm 3.5 Core complete.
Supply & Fixing for loadline MCCB Enclosures suitable for 'C' Frame FP (400A) with complete fixing all accessories
Supply and fix 4 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete
Excavation in trenches not exc, 1.5 cm wide and not exc, 1.5 m in depth,for foundation etc, or for shaft, wells cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5 m in depth in hard/dense soil and getting out, complete all as specified and as directed
Excavation in trenches not exc, 1.5 cm wide and additional 1.5 m or part there of in depth beyond the first 1.5 m
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 m, complete all as specified.
Removing excavated material to a distance not exc, 50 m and depositing where directed at a level not exc. 1.5 m above the starting point, complete all as specified
M&L for sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
M&L for factory made, machine pressed, unreinforced, pre-cast concrete cable cover HV, type 1, flat, size 300 mm x 180 mm x 40 mm complete all as specified and directed.
M&L for factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV, type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and directed.
M&L for galvanised iron strip 32 x 6 mm for earthings buried in ground complete.
M&L for Cement concrete in foundations of Poles all as directed as in type D-2 1:4:8 (40 mm graded aggregate).
M&L for Cement concrete in filling and mass concrete / coping of Poles all as directed, type C-2 1:3:6 (40 mm graded aggregate).
M/S ZTECH
RND ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .