Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.4 LAccepted-AOC SAYED MUSTAFA ALI ROAD HAKIMPARA P O SILIGURI 734001 DISTT DARJEELING W B INDEX NO E 139 BENG 2010 | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹76.8 L+₹13.1 L (20.6%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | Rejected-Technical NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | - | Rejected-Technical NOT ELIGIBLE | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ELIGIBLE | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ELIGIBLE |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
9 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE BINNAGUEI
HQ CWE BINNAGURI
REPAIR/MAINT OF ELECTRIC SUPPLY INSTALLATION AND CONNECTED WORK AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2021_MES_409846_1
8010/CWE/BIN(SEV)/ 76 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE SEVOKE ROAD
₹1.4 L
Yes
26 Feb 2021
6 Jan 2021
10 Feb 2021
6 Jan 2021
9 Feb 2021
28 Jan 2021
60 days
Amount
Schedule 'A'
M&L for dehydration of transformer oil through on load mobile stream line transformer oil filtration plant at site with all accessories connected to transformer and carrying out filtration of oil for desired dielectric strength i.e. not less than 55 KV at 2.5 mm gap complete all as specified and as directed. Note:- Oil to be tested before and after filtration and test report to be submitted by the contractor all as directed by Engineer- in- charge.
M&L for disconnecting power supply, Preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of 33 KV 02/04 MVA power transformer and its accessories with spraying machine in the yard including writing description of equipment in block English letter with white/Black synthetic enamel paint and re-connection after painting complete all as specified and directed.
Supply only transformer oil for topping up of transformers any capacity all as conforming to IS - 335 at different transformers & different locations. Note : The dielectric strength of the transformer oil must be 45 KV r.m.s (min). Make: Power oil / HP/ BP. Note : i) Test certificate in respect of the same to be submitted by the contractor duly signed by the Engr-In-Charge. ii) The dielectric strength of the transformer oil must be more than 45 KV (min).
Material and labour for spreading 40 mm graded stone aggregate in layers n.exc 15 cm thick around the 2 pole/ 4 pole structure, in power house at different area complete all as directed by Eng-in-charge.
Material and labour for servicing /testing of line breaker/control panel including outdoor CT, PT and relays in control panel of outdoor VCB of capacity 1250 Amps and rating 36 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required. (iii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iv) Checking the contact for wear. Replace if the contact piece has worn out. (v) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (vi) Check for rust and wear. (vii) Checking of spring charge mechanism (viii) Visual check for rust and deformation. (ix) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (x) Check for loosened connections, rust, damaged lead wires. (xi) Checking of control circuit & tighten the connections if any. (xii) Check close & trip coil. (xiii) Replacement of Dashpot/shock absorbers . (xiv) Replacement of carbon brush of spring charging motor (xv)Cleaning of porcelain bushing (xvi)Checking of limit switch (b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (d) Testing of followig Aux relay (i) Master trip relay. Note: All equipment used for tested should be calibrated within 1 year.
S&F in replacement of closing coil assembly 110 volts DC for outdoor VCB of rating 36 KV complete all as directed by Engr -in-Charge.
S&F in replacement of tripping coil assembly 110 volts DC for outdoor VCB of rating 36 KV complete all as directed by Engr -in-Charge.
Material & labour for repair /servicing of marshalling box panel of 33KV/11KV Power transformer of capacities 2/4 MVA including follwing :- (a) Testing & repair to control wiring. (b) Replacement of OTI, WTI gauge/ meter matching with OTI, WTI indicator in RTCC panel. (c) Replacement of fuse with MCBs (d) Repalacement of gaskets & locks including preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) on all sides of etc complete all as specified and directed.
Material and labour for Preparation of old painted surfaces of 33 KV MRS Switch yard including all outer steel structures/ frame/gate of bus bay at Grid, having by brushing/cleaning stains, greasy spots with thinner, applying two coats of spray painting (synthetic enamel paint) with spraying machine in the yard including writing description of equipments in block English letters 100 mm high with white/black synthetic enamel paint complete all as specified and directed.
Supply installation & commissioning in replacement of 30V/40A Float Cum Boost Battery Charger unit including battery bank comprising 15 Nos of 02 Volts-100 AH VRLA maintenance free battery. The CCCV battery charger consisting of copper wound, air cooled transformer, 01 Set single phase full wave bridge rectifier consisting of diodes and SCRs, liberally rated mounted on heat sink and complete with resistor/condenser network for surge supperssion . During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller, DC digital ammeter, DC digital voltmeter, Potentiometer, DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility for fuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom . The battery charger shall be divided into two compartments. The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:- (a) Input working voltage-180 -270 Volts (b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor - > 0.8 (d) On load unit watt efficiencies-> 80% (e) No load losses of complete charge-< 10% (f) Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j) Float charging -2.15 V/Cell (k) Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l) Reverse polarity -No damage will caused . A visual indication for reverse polarity will appear with an audio alarm. (m) Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of Battery: Exide
Supply, installation and testing of Numerical Relay draw out type in HT 11 KV VCB Panel comprising of new and modern numerical scheme for detecting, indicating and tripping the breaker on faults over-current and earth-fault in any of the three phases, Trip circuit supervision relay, 5% pick up for OC and 5% for EF. The relay shall also have the following features as minimum :- (i) Programmable rated current 1A & 5A, (ii) Last 8 fault record & 200 event record with time stamping, (iii) 4 analog CT input, 8 DI & 8 DO, (iv) Communicable on IEC61850 protocol, (v) Disturbance recording upto 300 cycles, (vi) Self supervision function. (vii) Auxiliary power supply 24-110 V DC. The relay shall be fully integrated with the feeder, internally capturing feeder statuses if available including Breaker On, Off, Spring Chrgd, Test, Service, AC-Fail, DC supervision relay, Trip circuit healthy relay, inter panel tripping, Master trip relay, local remote and display the same locally on a built-in LCD screen and suitably labeled status LEDs. Relay shall have facility to locally Trip/Close the breaker as a backup to TNC switch provided separately on the panel. The relay shall be fixed on new 2mm CRCA sheet of matching existing VCB panel color and suitable size covering all blank space formed by removing old mechanical type IDMT relay complete including associated wiring and integration with existing HT VCB panel complete all as specified and directed.
S&F power transformer radiator fin complete set for 4MVA PTR of make CG installed at 33KV MRS by draining out oil from defective radiator in clean cantainer, disconnecting radiator from PTR and connecting new factory made radiator fin with all connected accessories and refilling/toping up of drained oil after dehydration complete incl spray painting it with existing PTR colour synthetic paint complete all as specified and directed by EIC.
Supply, laying & testing inn repair XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm, 3 core incl taking down unsv one complete all specified and directed. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 70-120 sq mm of make denson item code XSO-12 incl taking down unsv one complete.
M&L for replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screw as specified type 410 SP-55, 11.0 meter long all as specified and directed by Engr-in-Charge. Make: Jindal/ Kwality steel Industries / Bansal Metal Works/ Calcutta Poles & tubes.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of UG cable/pipe in soft loose soil complete all as specified and directed.
M & L for Returning and filling in trenches including spreading, leveling watering and ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and as directed.
M & L for Removing surplus soil to a distance not exceeding 50m and depositing where as directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for providing sand cushioning for protection of UG cable in trenches with dry (coarse) sand approved quality including filling, spreading and punning down to desired thickness complete all as specified and directed.
Supply and laying unreinforced precast concrete cable cover class HV type 1 flat size 300x180x40mm complete all as specified and directed.
Supply and fixing GI pipe 80 mm medium grade for UG cable protection with all fitting fixed to pole or laid in trenches or laid in floor/rood complete all as specified and directed.
Supply only discharge rod suitable for 33 KV with extendable arm, end hook, suitable wire and clamps all as specified and directed.
M&L for boring holes 2mtr deep in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m complete all as specified and directed. (Note: Connected items like Pipes is measured and paid seperately under relevant items).
Supply and fixing thermoplastic cable junction box with terminals having protection IP 66/67 "weather proof" for outside installation with metric knockout entry for cable of size 16 sqmm 4 core and size 155x210x92mm with terminals and provision of one MCB SP 6A complete with all pole brackets and fixing arrangements all as specified and as directed of Make Hensel DK1616G or equvilent.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings with MCB SP in junction box, complete all as specified and directed.
S&F in repair 3 phase street light panel made of CRCA sheet IP54 with digital 24hrs timer, 65A triple pole contactor, 63A MCB triple pole and necessery complete wiring with max load 12KW of frame size 2 incl all connection and fixing arrangements on wall/floor/pole mounted of make Havells cat part no: IHXTS09120 Engr in charge.
S&Fin repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petrolium jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.
Supply, installation, testing and commissioning in replacement 33 KV current transformer oil cooled out door single phase, oil immersed and self cooled type of ratio 60/1-1-1A confirming to IS 2705 suitable for metering and protection equipment installed on control panels terminal block as specified below :- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary current- 60 Amp (d) Rated secondary current- 1 Amp (e) Nos of Core - 3 (f) Type: NP-OCT (g) Class: 1/5P10/PS (h) Burden: 20VA/20VA (i) Vk>150V (core 3), IO<30mA at Vk/4 (core 3) (j) STC: 26KA for 1 sec (k) Continuous thermal current rating 120 % of rated primary current (l)Temp rise at rated contineous thermal current over ambient at site - Less than or equal to 45 degree C (m) Insulation Level- 36/70 KV.170 KVP (n) 1.2/50 Micro second impulse withstand test voltage- 170 KV (peak) (o) Ins. class: A (p) Creepage distance of HV bushing - 900 mm (min) (q) Primary & Secondary winding material - Copper
Supply installation, testing and commissioning in replacement Potential Transformer (PT) oil cooled out door single phase (Earthed type) of voltage ratio 33 KV/110 V, accuracy class 3P - 0.5-3, 50Hz, burden 200/100 VA insulation level of 70kV/170 Kp as specified below:- (a) Normal System Voltage-33 KV (b) Highest System Voltage-36 KV (c) Rated Primary voltage- 33 KV/√3 (d) Rated secondary voltage- 110 V/√3 (e) Nos of Lt winding 2 (f) Metering Core Accuracy class - 0.5 (g) Metering Core Rated Burden- 200/100 VA (h) Nos of Phase- Single (Earthed Type) (j) Protection core accuracy class - 3P (k) Conforming to IS: 3156 (l) Rated Voltage Factor - 1.2 continuous & 1.9 for 30 Sec (m) Insulation Level- 70 KV.170 KVp (n) Temp rise at rated contineous thermal current over ambient at site - 45 degree. (o) Porcelain Bushing type - Hollow Cylinder (p) 1.2/50 mcro second impulse withstand test vol -170 KV (Peak) (q) Creepage distance of HV bushing - 900 mm (min) (r) Primary & Secondary winding material - Copper
M&L for cross arms bracings supports, clamps and back plates fabricated from structural steel sections incl nuts bolts washers welding, bending cold or hot, drilling holes for bolts in any shpae or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer and two coats of aluminium paint incl preparation of surfaces incl dismantling complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 coping 20 mm graded aggregate for grouting, finished even and smooth without using extra cement complete all as specified directed.
M&L for cement concrete in foundation, filling mass concrete type-C2, 1:3:6, (40mm graded aggregate) complete all as specified and directed.
M&L for PCC (1:4:8) (40 mm graded aggregate) Type C2 for base foundation of pole, stay incl frame work where reqd complete all as specified and directed.
Supply and fix lightning arrester, metal oxide type suitable for 33 KV system, discharge current 10 KA station class III, with surge monitor and base type mounted on steel structure all as directed.
M&L in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all specified and directed.
M&L in repair for earthing complete with copper earth plate electrode 60 x 60 cm 3.15 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all specified and directed
Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium Conductor, 11000 volts grade cross sectional area of size 185 Sqmm 3 core complete. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the luner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply and laying PVC insulated sheathed galvanised steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 2.5 sqmm 2 core 1100 volts grade. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply and laying PVC insulated sheathed galvanised steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 2.5 sqmm 4 core 1100 volts grade NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply and laying PVC insulated sheathed galvanised steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 2.5 sqmm 6 core 1100 volts grade.NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
M & L for aluminium hollow tube bar 32 mm dia 1mm wall thickness with connections to all equipments complete all as directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 185 sq mm of make denson incl taking down unsv one complete.
S&F PG clamps/flat pad connectors/sub stn connectors made of aluminium alloy for making connection on 33 KV bus bar (OH lines), CTs, PTs, VCBs etc complete.
M&L for aluminium conductor steel reinforced (ACSR) for overhead HT/LT line incl taking down unsv one complete all specified and directed
S&F disc insulator with harware fittings 11 KV grade 70 KN to be used for power lines. The insulators covered by this specification should conform to the latest editions of Indian Standard Specification IS: 731, IS: 2544 and IS: 5350. The Porcelin shall be sound free from defect, thorougly vitrified and smoothly glazed. The insulator shall be brown in clour and following specificationn:- (a) Nominal system Voltage - 11KV (b) Highest system Voltage -11 KV (c ) Minimum failing load - 10KN (d) P.F visible Discharge Voltage - 27 KV rms (e) P.F Minimum flash over voltage(Dry) - 130 KV rms (f) P.F Minimum flash over voltage (wet) - 90 KV rms (g) Impulse flashover voltage 1.2/50 micro second wave (Positive) -210 Kvp (h) Impulse flashover voltage 1.2/micro second wave (Positive) -230 Kvp (j) Power Frquency puncture withstand voltage on single unit -150 KV rms
All as per item no 45 here in before but pin insulator with hardware fittings 33 KV grade complete all specified and directed
PURBANCHAL BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .