Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Jul 2024, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR/MAINT OF MECHANICAL LAUNDRY, INCINATOR, BOILER, CONNECTED EM WORK, MISC E/M SERVICES AND ALLIED WORKS AT AF STN JAISALMER
2024_MES_658959_1
8242/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹40,000
Yes
2 Sept 2024
11 Jun 2024
13 Jul 2024
11 Jun 2024
11 Jul 2024
27 Jun 2024
Amount
Repair /maintenance/servicing of oil fired incinerator installed at 15 AFH, having 20 Kg/hours burning capacity horizontal/vertical type comprising of primary chamber, secondary chamber designed on "controlled air" incineration principle and provided with minimum temperature of 100 degree centigrade in the primary chamber and 1200 degree in secondary chamber , one fully automatic pressure jet type burner for each chamber of mild steel plate of adequate thickness (minimum 5mm thick ) 30 metre high chimney exhuast system high pressure ventury scrubber, PLC base control panel droplet separator etc including all other accessories and piping equipments and civil works required for installation of incinerator chimney complete all as specified and directed. Notes :- 1. The entire incinator plant is required to be kept serviceable during the entire period of CA. 2. 30 days duration of months shall be considered as one job ie from the date of work order plus 30 days will be measured as one job and so on upto ten months. 3. The Cost of spare parts (except the spare considered in CA as supply only), labour charges shall be deemed to be included in unit quoted rates, All repair work shall be carried out by rep of OEM/Authorised service centre of OEM.
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for the following :- (i) PLC based control panel droplet separator.
(ii) Fuel pump suitable size.
(iii) Emergency stack push button of power failure.
(iv) Interconnection piping .
(v) Valves as per site requirement.
(vi) Dampers and fiittings etc.
(vii) garbage dumping jaali made out of stainless steel rod, steel grade 315 (Melting range1480-1530 degree centigrade) not less 8mm dia stain less steel rod .
Repair/maintenance/servicing of laundry plant consisting of under mentioned plant/machinery/equipments including replacement of spare parts such as nuts, bolts, washers, oil, greaseing, PVC pressure pipe, PVC pipe connector etc and any other parts necessrily required for keeping the plant functionalother than major parts as mentioned in subsequent items for the following equipments installed at 15 AFH Jaisalmer. :- (a) Industrial washer extractor, heavy duty high spin, Model AXS 30 of capacity 30 Kg (steam heated) - 02 Nos (Fabcare) (b) Drying tumbler, front loading type, open pocket SS inner cyliner, reversible, double walled out drum Model DS300 of capacity 30 Kg (steam heated) (Fabcare) - 01 Nos (c) Flat work roatry drying ironer, chest heated, front feed front return penumatically operated ironing chest, adjustable ironing pressure, varriable freqency, inverter drive, conveyer belt feed, 530 dia x 3000L Model FRS53-300 (Steam heated) Fabcare- 01 Nos (d) Vacuum finishing table Model VF 120, table top size 1200x750mm electric steam iron model ERS220, teflon shoe Model TF220 Fabcare- 02 Nos (e) Dry linen trolley, overall size 850x650x1670mm heigh Model DTR50 Fabcare- 02 Nos (f) Air compressor reciprocating type, tank capacity 100 litre, 8kg/sqcm, fully automatic complete with driving mechanisim, Elgi -01 Nos (g) Steam boiler of capacity 200 Kg with all accessories, including plumbing work, Thermax - 01 Nos Notes :- 1. The entire laundry plant is required to be kept serviceable during the entire period of CA, 2. 30 days duration of months shall be considered as one job ie from the date of work order plus 30 days will be measured as one job and so on upto ten months. 3. The Cost of spare parts (except the spare considered in CA as supply only), labour charges shall be deemed to be included in unit quoted rates, All repair work shall be carried out by rep of OEM/Authorised service centre of OEM
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for the following :- (a) Supply only Transformer suitable for 30kg laundry machine.
(b) Supply only Sequence Controller RBL (Oil Burrner Part) .
(c ) Supply only Temperature 101 controller .
(d) Supply only Solenoid valve .
(e) Supply only rubber.
(f) Single piston water pump with safety valve and vessel.
(g) Steam glove/gate valve 25mm IBR.
(h) Steam glove/gate valve 20mm IBR.
(j) Ball valve 15mm .
(k) Water limit switch.
(l) Steam pressure switch.
(m) Blow down switch.
(n) Steam pressure gauge 4 inch.
(o) Fuel pressure gauge 2.5 inch.
(p) Hose pipe high pressure 1 inch .
(q) Hose pipe high pressure 3/8 inch.
(r ) Steem heating coils stainless steel tube as per sample for boiler of 200 kg Thermax.
(s) Burner suitable for 200 kg thermax boiler as per sample.
(t) V belt as per sample.
(u) Pneumatic pipes & fittings suitable for FABCARE make drying tumbler as per sample.
(v) Heater suitable for FABCARE flat bed press as per existing.
(w) GIC timer suitable for FABCARE make flat bed press as per existing.
(x) Glass with rubber packing and ss screw suitable for Fabcare make drying tumbler as per existing.
( y) Ball valve 25mm IBR.
(z) Gate valve 50mm dia.
(aa) Spring flat bed press main for flat bed press suitable for fabcare flat bed press as per existing.
M&L for disconnecting, dismantling, taking down and transporation of unserviceable UPS of capacity 10 KVA, 3 phase system installed at 15 AFH near OT and Repair/complete overhauling of unserviceable UPS 10 KVA at workshop and make it completely serviceable in and including all spare parts like required to make the UPS serviceable except the following spare complete and reinstallation of UPS at site after repair work complete and making the UPS fully functional complete all as directed. Note :- 1. The unserviceable UPS is required to be made fully functional including all spare parts except the sapre parts considered in CA here in after, these shall be measured and paid seperately under relevent items. The JOB includes complete labour/Technician cost, dismantling, transportation and all other items required to make it serviceable, nothing extra shall be payable on this regard
Supply and fix in replacement of battery,12 V 26 AH capacity, suitable of UPS duty including testing for its proper functioning as specified and directed by Engineer-in-Charge. Make Exide/Amron/Sukam/Okaya Note :- Battery shall be original make accepted No substitute of battery.
Supply and fix in replacement of AVR Card suitable for UPS 10 KVA as per existing at site (15 AFH, near OT Room) including testing for its proper functioning as specified and directed by Engr-in-Charge
Supply and fix in replacement of main Card suitable for UPS 10 KVA as per existing at site (15 AFH, near OT Room) including testing for its proper functioning as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Card transformer suitable for UPS 10 KVA as per existing at site (15 AFH, near OT Room) including testing for its proper functioning as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of main transformer suitable for UPS 10 KVA as per existing at site (15 AFH, near OT Room) including testing for its proper functioning as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of capacitor suitable for UPS 10 KVA as per existing at site (15 AFH, near OT Room) including testing for its proper functioning as specified and directed by Engineer-in-Charge.
Supply fixing and connecting, LED flood light of capacity 150 watt, aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED's should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file, in and including taking down of old unserviceable light fitting complete all as specified and directed.
S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) complete all as specified and directed.
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 including taking down of old unserviceable connection wire complete all as specified and directed.
Supply and fix junction box made out of Fiber reinforced plastic with IP 55/IP 65 protection of size not less 200 x 140 x 95 mm (in side dimensions) , having 5 way terminals mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
Material and labour for taking down gear assembly of EOT cranes, connected induction motor, servicing, greasing of motors etc complete and dismantling gear box assembly taking out gear and other worn out parts, replacement of worn out parts refilling of gear oil, over hauling, oil seal replacement including lathe work as required at site re-assembly, re-fixing the same and testing including repair of EOT cranes installed above the height of 5.0m from working level, thoroughly cleaned of all dirt, grease, scale and rust by shot blasting or chemical cleaning methods, removing old paint from EOT cranes and attachments parts such as double girders, motors, crane rail, Gearbox cabinet, LT panel board and all moving parts. A single coat of primer shall be given to all parts exposed to the weathering effects and two coats of paint as approved by GE for indoor/outdoor cranes shall be given on all primer painted surface. The bright exposed parts of the crane shall be given one coat of rust inhibitor. Interior of all gear boxes shall be painted with one coat of oil resisting paint. Writing the Technical details of respective crane as per existing data available on each cranes with paint as approved by GE, complete all as directed by Engineer-in-Charge. The capacity of Crans with their locations are as under :- Note :- (Spare parts shall be measured and paid seprately) (a) Capacity 1 to 3 TON.
(b) Capacity 5 ton to 10 TON.
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for Cranes/Hoists of Capacity 01 TON TO 3 TON :- (i) Magnetic Coil.
(ii) Over load relay 0.6 to 1 Amps Make- L&T/Siemens.
(iii) TP Contactor 25 Amps,ML 1.5, 110 Volts, Coil Voltage. Make – L&T
(iv) Brake Pads.
(v) Push Button with auxiliary contacts. Make – L&T
(vi) Limit Switch with two contacts in oil tight die cast aluminium housing. Make – Siemens.
(vii) Drive as per existing.
Supply only Spares/Components after approval and as directed by Engineer-in-Charge for Cranes/Hoists of Capacity 5 to 10 TON :- (i) Oil Seal.
(ii) Gasket.
(iii) Brake for CT/LT Coil.
(iv) Pedant Push Button. Make – Siemens/L&T.
(v) Pedant Push Button with auxiliary contacts. Make – Siemens/L&T.
(vi) No Volt Coil 1100 volts Make L&T suitable for contactor ML-4 Make- L&T or equivalent.
(vii) Carbon Brushes.
(viii) Over Load Relay 42 Amps. Make – L&T.
(ix) Contactor 45 Amps, 110 volts, ML-4 Make – L&T
(x) Drive as per existing.
Load Testing of HOT cranes/EOT Cranes with full load and 25% over load all as specified in IS No 301 of 1977 and 3177 of 1977 and writing the date of load testing all as directed by the Engineer-in-Charge for the following capacity :- (i) Capacity 01 TON to 03 TON Note :- Load will be provided by the Department except EP shop the Contractor will be responsible for provision of load materials in EP shop.
(iii) Capacity 10 TON.
M&L for annual maintenance of EOT cranes of capacity 1 to 10 TON installed at Hangers in tech area at a height of 4 to 8 mtrs by opening of brackets of ball bearing, cleaning/removing of old lubricants/ grease using thinner from the moving parts of the cranes, checking of moving parts for its serviceability, cleaning of rail using sand paper and applying of new castrol grease/AP3 grease on all the moving parts/ Ball bearing and refixing of brackets and making the crane fully functional and smooth complete all as specified and directed at site by Engineer-in-Charge.
M&L for annual maintenance of HOT cranes of capacity 1 to 3 TON installed at Bldgs in tech area at a height of 3 to 6 mtrs by opening of brackets of ball bearing, cleaning/removing of old lubricants/ grease using thinner from the moving parts of the cranes, checking of moving parts for its serviceability, cleaning of rail using sand paper and applying of new castrol grease/AP3 grease on all the moving parts/ Ball bearing and refixing of brackets and making the crane fully functional and smooth complete all as specified and directed at site by Engineer-in-Charge.
Supply, fixing and connecting conventional optical smoke Detectors Complying with and type certified complete with standard base for conventional detector complete all as specified and directed.
Supply, installation, commisioning and testing 02 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, installation, commisioning and testing 04 zone conventional fire alarm control panel with features such as non latching zones, false alarm management, EN 54-2, EN 54-4 LPCB approved complete all as specified and directed.
Supply, fixing and connecting conventional type manual call point resettable complete all as specified and directed.
Supply, fixing, connecting and testing conventional wall sounder complete all as specified and directed.
Supply and fix Remote response indicators complete all as specified and directed.
Supply, fixing and connecting in replacement analog addressable type smoke detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed by Engineer-in-Charge .
Supply, fixing and connecting in replacement analog addressable type multi criteria combination of (smoke & heat) heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed by Engineer-in-Charge.
Supply, fixing and connecting in replacement analog addressable type heat detector with in built short circuit isolator multiple senstivity level, dual LEDs for 360 degree view , complete with junction box for mounting on surface/false ceiling complete with necessary fixing accessories all as specified and directed by Engineer-in-Charge.
Supply, fixing and connecting intelligent (Addressible) manual call point resettable operating element, in built isloator, Bi colour LED status complete all as specified and directed.
S&F in replacement 2x1.5 sq. mm +1x1.0 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed complete as per site requirement and as directed by Engr-in-charge
S&F in replacement 2x2.5 sq. mm +1x1.5 sq. mm earth wire for circuit/submain wiring alongwith earth wire, FRLS-H, PVC insulated copper conductor, single core cable drawn through existing conduit/casing caping of any type or size in surface/recessed complete as per site requirement and as directed by Engr-in-charge
Supply and fixing in repair air termination, single pointed copper rod 12 mm dia and 300 mm long all as specified and as directed
M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw all as specified and directed .
M&L in repair copper strip 20x3.0 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground .
M&L for porceiline insulator suitable for fixing earthing strip to the wall / floor etc all as specified and as directed .
Supply only GI Pipe light grade, 40mm dia , galvanized, with all fittings complete all as specified and directed.
Manisha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .