Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | -28.00% | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.9 CrAdmitted-Finance | -26.20% | ₹1.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹1.9 CrAdmitted-Finance KEDAR BADI KHAIRAGARH ROAD DONGARGARH DISTT RAJNANDGAON CHHATTISGARH 491445 | RAJNANDGAON | CHHATTISGARH | 491445 | -25.00% | ₹1.9 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.0 CrAdmitted-Finance LADAKH AUTONOMOUS HILL DEVELOPMENT COUNCIL LEH OFFICE OF THE EXECUTIVE ENGINEER RURAL ENGINEERING WING LEH | -21.56% | ₹2.0 Cr | L4 | Admitted-Finance |
| 5 | L5₹2.0 CrAdmitted-Finance | -20.00% | ₹2.0 Cr | L5 | Admitted-Finance |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
22 Dec 2025, 4:00 pmClosed
Executive Engineer PWD Rnb division Leh
Office of the Executive Engineer PWD Rnb division Leh
Construction of NCC complex at Phyang Leh ( Staff quarter at NCC campus ) Under SDP
2025_PWD_18096_1
E Tender 170 of R and B Division Leh
Open Tender
Civil Works - Buildings
730 days
Leh
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
Executive Engineer PWD Rnb division Leh
₹5.0 L
9 Apr 2026
3 Dec 2025
24 Dec 2025
3 Dec 2025
22 Dec 2025
3 Dec 2025
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. Ordinary or hard rock.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
450 mm dia. R.C.C. pipe
Carriage of Materials by Mechanical Transport including loading,unloading and stacking beyond 5 km
Providing & laying cement concrete in retaining wall , return walls ( any thickness ) ,including attached pillasters,columns peirs, abuttments ,pillars ,posts , struts, buttresses , string or lacing courses,parapets ,coping , bed blocks , anchor blocks,plain window sills,fillets , sunken floors,etc.upto floor five level , excluding the cost of centring , shuttering & finishing.1:2:4 ( 1 cement :2 coarse sand :4 stone aggregate20mm nominal size
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
All works above plinth level up to floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within permissible utilization of 20% each, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts
Shelves (Cast in situ)
Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Weather shade, Chajjas, corbels etc., including edges
Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand)
Providing & fixing upto floor five level compressed stabilized earth blocks (CEB) made an appropriate mix of dry inorganic subsoil, non-expansive clay, sand, and aggregate with 5% cement as stabilizer, in mud mortar, including cost of materials complete.
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size betweencavity wall, complying with ISO 4898:2008 & ASTM C 578- 08b - type VI, having thermal conductivity of0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed asper ASTM D 1621, density of 34-36 kg/m3 as per ASTM D 1622, water absorptions < 1% by volume as perASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) asper ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 classA, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panelsmade of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density not less than15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in apreset mould. The outer face on both sides of the panels will be non asbestos fiber cement board confirming to IS14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mmthick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall bethick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall bepreferably fixed into 'C' channel made of 1.2mm thick MS plate screwed / fastenened to the slab /column/ beam etc.The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor & roofing withadditional structural support, steel or RCC depending upon the design. All the operation shall be completed in allrespect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Costof all the material is included except "C channel" which will be paid seperately). Non load bearing panels 75mm thick of required size
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade Red sand stone
Area of slab above 0.50 sqm
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class teak wood
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the likeWeather shade, Chajjas, corbels etc., including edges
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminum doors of approved quality with necessary screws etc. complete as per direction of Engineer-in-charge.
Providing and fixing Drapery rod shall be made of 20 gauge cold rolled steel strip. Which is electrical resistance welded, The section will be available 25.4 mm diameter the section shall be coated with acid resistance polymer finial shall made from ABS material in nearest matching colour of rod. The ring shall be made from ABS material in nearest matching colour to rod. Brackets of made of galvanized steel.
Providing and fixing traditionally carved wood work (Shingstak) over doors and windows including all accessories as per the direction of the Engineer in-charge, complete with; Local willow wood
Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS :15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing ofracks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction ofEngineer-incharge.
Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thickPVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loadedhinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing andfixing auto closing hinges shall be paid separately)
Providing and fixing 19mm thick both side balancing lamination factory pressedBWP grade marine plyas per IS 710 of approved brand boxes,shelves,racks, almirah, cupboard and drawer etc. includingnecessary nails,screws etc. complete as per direction of Engineer-in-charge.
Providing and fixing stainless steel fancy handle of approved make fixed with SSscrews etc. complete as per direction of Engineer-in-charge. 200 mm
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40 x40 x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer.
Providing and fixing factory made uPVC white colour fixed glazed windows / ventilators comprising ofuPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from roll forming process of required length (shape & sizeaccording to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extrudedinterlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (whitepowder coated) handle with key on one side of extreme panels along with zinc plated mild steel multipoint locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (ifrequired), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearingcapacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessarystainless steel screws etc. Profile offrame & sash shall be mitred cut and fusion welded at all corners,including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backerrod of required size and of approved quality, all complete as per approved drawing & direction ofEngineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid 9.147F.1 Two track two panels sliding door made of (big series) frame 67 x 50 mm & sash 46 x 82 mm both havingwall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door above 2.00 sqm upto 5.00 sqm) separately).Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.uPVC profile should be tested by BSI(UK) & SKZ(Germany) @25000 weathering hours
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75 mm deep chase
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in heightdimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extrudedprofiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll formingprocess of required length (shape & size according to uPVC profile), appropriate dimension of uPVCextruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required),EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along withzinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powdercoated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size forcoated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body withmitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainageof water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled withweather proof silicon sealent over backer rod of required size and of approved quality, all complete asper approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh andsilicon sealent shall be paid separately). Variation in profile dimension in higher side shall be acceptedbut no extra payment on this account shall be made.Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm bothhaving wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriatedimension. (Area of window above 4.00 sqm upto 8.00 sqm).
Shoe (Plain) 110 mm
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle tee with door 110 mm
Grading roof fo
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work a
r water proofing treatment with Cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete.
Providing and fixing of LVT click N lock 3MM as per ASTM F 386 with .50MM wear layer vinyl floorings of FLOORS series with dimensions of 169MM and length of 1210MM or Tiles 305MMX615MM size as per company standard should be approved by architech. 3MM LVT with additional 2mm thick cork sheet (If required) to laid on hard, levelled, smooth and moisture free sub floor. Vibrant LVT Vinyl flooring should have traffic classification 32 . LVT should be floor score and T abrasion class approved. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It shoukld be ASTME662 qualified on Smoke density test. Product should be fire rating of the product should be Bfl-S1. and Wear Group of T Class. As per approved shade and colour as per the satisfaction of the Architect.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost ofcutting and making good the walls and floors : Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100 mm inlet and 100 mm outlet
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer ), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting , risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix : :6 (1 cement: 6 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Making grooves as per design in plaster 10mm to 20mm wide.
nd fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Providing material and labour for laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150mm dia R.C.C pipe
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size
Painting with enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan.
Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever requireWhite Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps.
Providing & fixing cockcroch trap S.S grating of approved design for floor traps SS grating of approved design for floor traps etc. including setting in floor with cement mortar 100 mm dia Make ( make Kick / jaquar / Cardin.
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing material and labour for fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810gms. 15 mm nominal bore.
Providing and fixing SS AISI-316 Grade Designer Double Towel Rack bottom hanging complete with brackets fixed with CP brass screws PVC sleeves etc. Complete: 650 mm long .Model No- RDA-018, of Acquaviva or equivalent,(Make: Kich/Jaquar/Cardin
Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) conforming to IS : 1322 and sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic dm per sqm including preparation of surface but excluding grading, complete.
Providing and fixing toilet paper holder : C.P. brass
PN - 16 Pipe, 32mm OD (SDR-7.4)
PN-16 Pipe, 40 mm OD
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Chajge. (Concealed work including cutting chases and making good the walls etc.,)18.5.1 PN-16 Pipe, 20 mm OD (SDR-7.4)
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings i/c trenching .refilling & testing of joints complete as per direction of Engineer in Charge. (External work) PN-10 Pipe, 50 mm OD
Providing material and labour for fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing material and labour for placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
32 mm nominal bore
40 mm nominal bore
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Internal workexposed on wall) Internal work-exposed on wall with clamps at 1.00 meter spacing- 16 Pipe, 25mm OD (SDR-7.4)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
Providing and fixing brass stop cock of approved quality : 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357mm
75mm diameter :
75mm diameter :
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore
Providing and fixing soil, waste and vent pipes : Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905100 mm dia
75 mm dia
100 mm inlet and 75 mm outlet
Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5mm flat of specified shape, projecting 75mm outside the wall surface and fixed on wall with 4 Nos, 6mm dia expansion hold fasteners including drilling necessary holes in brick wall/CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30mm x 1.6mm galvanized M.S. flats of specified shape and of total length 420mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6mm, one bolt on each side of the pipe. Total bracket length 580mm of approved shape and design (for single 100mm dia pipe)
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 (1 cement :4 coarse sand): 100 mm dia.
Providing and fixing square- mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.20.3.3 180 x 150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Heel rest sanitary bend , Sand cast iron S and S as per IS:1729 100 mm dia
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal si
ze),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
75 mm dia Sand cast iron S&S as per IS- 3989
250mm dia R.C.C pipe
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.50 MB
BOQ_43758.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid