Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹1.7 LQualified Make: microtek
Model: MICROTECK 5 KVA 192V WITH 16 BATTERIES OF 26AH 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: MICROTECK 5 KVA 192V WITH 16 BATTERIES OF 26AH | L2 | Qualified | |
| 2 | L3₹1.9 LQualified Make: BPE
Model: BPE PB Series AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE PB Series | L3 | Qualified | |
| 3 | L4₹1.6 LQualified Make: BPE
Model: BPE PB1105L16 DIAMOND COLONY NEW PALASIA INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: BPE
Model: BPE PB1105L16 | L4 | Qualified | |
| 4 | Qualified Make: BPE
Model: BPE PB Series 109 DIAMOND TRADE CENTRE DIAMOND TRADE CENTRE DIAMOND COLONY NEW PALASIA NEW PALASIA INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: BPE
Model: BPE PB Series | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Nov 2018, 2:00 pmClosed
Online UPS
Online UPS MSME Exemption For Years Of Experience And Turnover No Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 1/7 Backup time (Minutes) 60 60 Minimum VAH (VAH) 12000 12000 Warranty for UPS (Years) 2 1
2
3
4
5 Movable trolly for Batteries With With
Without
Without trollery but with rack Warranty for battery 1 1
2 Degree of Protection IP20 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Yes * 2/7 Current Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/7 1 Ajay Kumar Pandey 411021
Dr Homi Bhabha Road Pashan 1 30 Online UPS ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15
30
60
90
120
180
240 Minimum VAH (VAH) 800 400-640000 Warranty for UPS (Years) 1 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of 1.0 * 4/7 M.S.Sheet Enclosure duly painted (mm) Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
Battery Voltage and Current Yes * Indicators for mains presence
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 Yes * 5/7 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ajay Kumar Pandey 411021
Dr Homi Bhabha Road Pashan 2 30
777834
GEM/2018/B/109159
Online UPS,Online UPS
30 days
Maharashtra; Pune
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS | - | - | - |
| Online UPS MSME Exemption For Years Of Experience And Turnover No Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 1/7 Backup time (Minutes) 60 60 Minimum VAH (VAH) 12000 12000 Warranty for UPS (Years) 2 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries With With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 1 1 | - | - | - |
| 2 Degree of Protection IP20 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Yes * 2/7 Current Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/7 1 Ajay Kumar Pandey 411021 | - | - | - |
| Dr Homi Bhabha Road Pashan 1 30 Online UPS ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 800 400-640000 Warranty for UPS (Years) 1 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of 1.0 * 4/7 M.S.Sheet Enclosure duly painted (mm) Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains presence | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 Yes * 5/7 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ajay Kumar Pandey 411021 | - | - | - |
| Dr Homi Bhabha Road Pashan 2 30 | - | - | - |
Exempted
5 Nov 2018
24 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_777834.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .