Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 792 2 A CIVIL LINES NEAR BABULAL MILL GWALIOR ROAD JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹36.8 L+₹2.6 L (7.69%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹37.8 L+₹3.6 L (10.6%)Rejected-Finance 05 BABA PALACE MUSRIGHARARI JANDAHA ROAD MUSRIGHARARI SAMASTIPUR BIHAR 848101 | SAMASTIPUR | BIHAR | 848101 | L3 | Rejected-Finance not become lowest bidder |
Tender Value
₹44.0 L
EMD Value
₹88,100
Closing Date
12 Jul 2023, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
SPL REPAIR TO SEWAGE LINE AT PLASSEY LINE, ORs MD ACCN AT PLASSEY LINE, REWIRING OF BLDG NO. P 29, REPLACEMENT OF PIPE LINES UNIT WATER POINT AND PROVN OF WALL CLADDING IN OFFRS ACCN OF AGE B/R- II UNDER GE JHANSI
2023_MES_602224_1
GE/JHA/TOK/59 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹88,100
Yes
14 Aug 2023
9 Jun 2023
15 Jul 2023
9 Jun 2023
12 Jul 2023
23 Jun 2023
9 Jun 2023 - 16 Jun 2023
Amount
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) complete all as specified and directed
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed complete all as specified and directed
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Taking down eaves gutter and rain water pipes including all fittings any size and pattern.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed
Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed
Taking up or down 25 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed
Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed
Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.00 Sq. M each complete all as specified and directed
Demolition of RCC Not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, Cover slab and similar suspended work complete all as specified and directed
Demolition of cement concrete of any description and in any position of WC’s/Bathroom etc in sunken portion area above ground floor, removing demolished material completely and old waste pipe from sunken portion and cleaning the side/bottom surface of sunken floor with wire brush, complete all as specified and directed.
Demolition existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime concrete etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed.
Dismantling water tank and removing to store exc. 250 litres & not exc. 500 litres capacity of tanks, complete all as specified and directed.
M & L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers(first coat 10 mm & second coat of 5 mm ) mixed with WPC as per menufacturers intructions, finished even and smooth without using extra cement complete all as specified and as directed. ( Note: Water proofing compound shall be measured & paid separately)
M & L rendering 5 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed..
M & L preparing newly plastered surfaces of wall and applying two coats of oil bound distember over 1 mm putty and a coat of chalk whitening primer preparing to make the surface to be plain and smooth before primer complete all as sppecified and directed.
M & L for preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M & L for preparing old plastered surfaces of ceilings and applying two coats of white wash complete all as specified and directed.
M & L for complete removal of exisiting treatment, washing and rubbing of old distempered surfaces and applying two coats of oil bound distember over over 1 mm putty and a coat of chalk whitening primer preparatory to distempering complete all as specified and as directed.
S&F Window ECO 4000, of double rebate openable/fixed window/Ventilator made of galvanised steel colour coated/powder coated (base steel as per IS 513 Of 'D' quality, galvanised as per IS 277 with zinc of 120 gms/sqm) with total thickness of coating 0.58 microns thick and back coated with alkyd backer 5-7 micron thick or powder coated with pure polyster powder up to 50-60 micron thick. Outer frame section 72 x 55 mm , center mullion section 72 x 50 mm, shutter section 47 x 20 mm, fly mesh section 40 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consist rebate for glazed shutter, fly mesh and 20 mm provision for guard bars/grills, the section cut to length mitre joined with corner bracket, center millions fixed with mullions cap, stay, handle, latch, 2 nos of heavy duty stainless steel pivot hinges per shutter and paneled with 5 mm thick plain float glass and S. S. mesh for fly mesh shutter (304 grade), fitted using EPDM (Ethyl Propyelene Diamine Monomer) gaskets including fixing windows in the Concrete /Masonry wall by means of self expanding screw, including 10 mm square bars welded to 6 x 12 mm flat at a distance 150mm C/C (Pitch) etc complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete.all as specified and directed.
M&L for Coloured Glazed ceramic tiles 600x 300 x 7 to 8 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick redering in CM 1:4 on wall complete all as specified and directed..
M&L for jointless Virified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but n xc 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6.complete all as specified and directed
All as per item here-in-above but in skirting including 10mm thick backing coat in CM 1:4 on wall complete all as specified and directed..
M&L for machine cut Kota stone slab flooring 20-25 mm thick and laid over and incl 20 mm thick screed bed in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab, with and including Cutting / Griding / mirror Polishing on Kota stone as per local trade practice, complete all as specified and directed.
All as per item here-in-above but on vertical surfaces such as skirting/dado over 10mm thick CM rendering in CM 1:4. complete all as specified and directed.
M&L for Granite 20 mm thick over including 10 mm thick CM 1:4 (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rubbing and polishing complete all as specified and as directed.
M&L for 75mm PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in plinth protection and path laid in alternate panels not more than 3 mtr in length, laid to slope 1:30 finished even and smooth without using extra cement including forming joints 10 mm wide and upto full depth of PCC and filled with bitumen mastic (1:3) 1 part bitumen 85/25 and 3 parts of sand complete all as specified and directed. {Note:-Bitumen mastic will measured and paid seperately }
M&L for grade A forming construction joint 30 mm deep x 10 mm wide and filled with bitumen mastic all as specified and directed.
S&F in repair Aluminium Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed
S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, complete all as specified and directed.
S&F 20 mm dia of Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iorn pipe and fixed. (minium weight 20 mm-210 gms) etc, complete all as directed.
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 15 mm bore, complete all as specified and directed
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm bore, complete all as specified and directed
S&F gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 25 mm bore, complete all as specified and directed
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches complete all as specified and directed.
Supplying and laying OD 16 mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches complete all as specified and directed.
Supply, fixing, laying & testing 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid in trenches complete all as specified and directed.
Supplying and laying OD 20 mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP waste copling, 32 mm PVC Waste pipe 600mm long complete all as specified and directed
Supply and fixing in repair vitreous china squatting pan, Orissa pattern, long pan size 580 x 440mm with CI trap, long neck 100mm with integral foot rest & fixing including making good floor to match complete all as specified and directed.
Supply and fixing in repair PVC low level flushing cistern 10ltrs capacity, syphonic action type white with inlet ball valve, float and handle including brackets with 32mm dia flush pipe of polythelene of low or high density complete all as specified and directed.
S & F in repairs 15 mm bore Bib taps, fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repairs 15 mm bore Bib taps long body fancy type cast copper alloy,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repairs 15 mm bore stop/angle cock fancy type,chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repairs 15 mm bore conceald stop cock fancy type,chromium plated with long shank and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S&F in replacement of pillar taps, 15 mm dia, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, complete all specified and directed.
S&F SS grating of square/round shape, overall size of 150x150mm with hinge type openable jali of 100 mm dia size with and incl fixing with CM to floor/nahani traps etc, complete all as specified and directed
S&F in replacement of PVC connection 450 x 15mm dia PTMT (PVC), complete all as specified and directed
S & F in repair Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair SS Towel Rail 600mm Long fixed with and including chromium plated brass screws complete all as specified and directed
S&F in repair of Brass CP connection 15mm dia and 45cm long with 2 Nos brass check nuts with washers for geyser, complete all as specified and directed
S&F of Ringfit PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.
S&F of PVC (SWR) pipe of 110 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as directed.
S&F of Ringfit PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end as self socketed with an integral groove to hold the rubber gasket, with and incl rubber tighten gaskets, ringfit sockets etc, complete pipe duly fixed to wall, complete all as specified and directed.
S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as directed.
S&F 110 mm bore PVC (SWR) bends with access door of any radius, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC(SWR) vent cowl 110mm bore, jointing to waste pipe, complete all as specified and directed.
S&F PVC Nahani/ floor trap of 75 mm outlet, jointing to waste pipe, complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm (± 5 mm tolerence in dimension) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)., supplying & fixing in opening as per specification & drawing complete all as specified in SSR Part-II 2020 section 8.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid moulded flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
S & F for Factory made double extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified & directed.
S&F 35 mm thick Factory Made 100% Solid WPC ( Wood polymer Composite ) Glazed and skeleton Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), alcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured and an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company
S&F 18/19mm thick pre-laminated WPC board , exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work for cupboard shutter complete all as specified and directed by Engr-in-charge
S&F Continuous (piano) hinges, SS 304, 30 mm width of flap (when open), bright finish or electro galvanised, complete all as specified and directed
S&F magnetic catcher for fixing in cupboard, to hold the shutter in closed position, complete all as specified and directed
S&F of 100mm butt hinges Stainless Steel fixed with SS wood screws or welded to angle frame, complete all as specified and directed.
S&F of 200 mm long Stainless Steel barrel tower bolts, , with bright bolt and fixed with screws, complete all as specified and directed.
S&F of 150mm long Stainless Steel pressed handles, oval type, stove enamelled black and fixed with screws, complete all as specified and directed.
S&F of 300mm long Stainess steel, sliding door bolt clip and bolt type, with bright bolt not less than 12mm dia with and incl minimum of 6 bolts and nuts, complete all as specified and directed.
S&F 200 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F of 150mm long barrel tower bolt aluminum anodized extruded section fixed with cadmium plated screws complete all as specified and directed.
S&F of 150mm aluminum handle cast type anodized complete all specified and directed.
S&F of mild steel ordinary rat tail rod pattern springs of size 300mm including roller and roller plate complete all as specified and directed
S&F for Door stopper 140 mm of aluminium alloy body anodised with tongue of rubber bush at one end fixed to door complete all as specified and directed
S&F Rubber bush of 25mm long fixed to door complete all as specified and directed
S&F 125 mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S&F 3mm thick sheet glass frosted/figured and pin headed glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or galvanized wire staples complete all as specified and directed
M&Lin repair for stainless steel curtain rod 25mm dia with caps/lobs and wall mounting bracket cutting in to length required at site complete all as specified and directed by Eng-In-Charge
S & F for stainless steel kitchen plate rack size 750x 600x230 mm including fixing arrange ment to walls with rawel plug or wooden plugs complete all as specified and directed
Providing and fixing Handmade Double Bowl Stainless Steel Sink (SKU KS140DBD(R10) With Sound Reduction Pad on Bottom and All Sides With Anti-Condensation Coating Depth :228 mm (9″) Thickness :1 mm Radius : R10 Product Dimensions Over all Size : 1400×500 mm(55″x20″) Bowl Size : 460x460x228 mm (18″x18″x9″) i/c with Plastic double bowl Sink Connector of Required size and sink waste of approved brand i/c painting fitting & brackets, cutting and making good the wall wherever required complete all as specified and directed
Supply only integral liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed Make : Dr Fixit LW + Professional or equivalent of Fosroc / Sika
M&L for RCC M-25 (Nominal Mix) (using 20 mm graded stone agg) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
All as per item here-in-above but for chajja only all as specified and directed
M&L for mild steel deformed TMT bars 5 mm To 10mm dia (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
Form work to flat soffits of suspended slabs such as roof slabs, floor slabs and lintels, landingand similar work n exc 200mm thick complete all as specified and directed
Form work to flat chullah hoods, chajjas, troughs and similar items including edges etc. complete all as specified and directed
Form work to sides and soffits of flat floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed
All as per item here-in-above but exc 5cm but not exc. 10cm wide
M&L for 15mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces mixed with liquid water proofing solution to vertical surface complete all as specified and directed Note:-liquid water proofing solution shall be provided in 150ml in 50 Kg of Cement by weight and cost of liquid water proofing solutionmeasured and paid seperate item
M&L for 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in padding levelling etc and roof kerbs with liquid water proofing solution finished even and fair with proper slope as prepatory works to water proofing treatment complete all as specified and directed Note:-liquid water proofing solution shall be provided in 150ml in 50 Kg of Cement by weight and cost of liquid water proofing solutionmeasured and paid seperate item complete all as directed.
M&L for application/forming of waterproofing liquid membrane moistening the prepared surface for proper dispersion and penetration and applying two component cementitious elastomeric water proofing coating damp block 2k as per manufacturers specifications. The treatment shall be carried out to the entire bottom surface and vertical surface upto the bottom height of wall tiles. Adequate curing to be done on vertical surfaces and ponding test for 48 hours on the bottom surface to be carried out complete all as specified and directed. Make: M/S Asian Paint Ltd/ Choksey Chemicals Pvt Ltd./Sika India Pvt Ltd./Bostic India Pvt Ltd/Fosroc Chemicals/STP Limited / Maruti Bitumen Pvt Ltd/IWL India Limited/Berger Paints India Ltd.
NOTE : (a) Treatment shall be done through authorised applicator/representative of the manufacturer only. (b) Warranty for water proofing to be submitted by the contractor as per manufacturer norms (c) The contractor shall have MOU with any one of manufacturer and also with their authorised applicator mentioned in the tender. Authorised applicator shall have valid authorisation letter from the manufacturer and shall have been issued not less than 30 days from the date of commencement of the work. The authorisation letter needs to be valid for the complete period of execution work. (d) After preparation of the surface, Engr-in-Charge shall approve the same before applying finishing coats. (e) Building wise stage passing register shall be maintained and shall be signed by Engr-in-Charge and contractor. (f) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU has been entered into. (g) Contractor shall submit approved company generated 05 years warranty card at the time of submission of Final Bill.
M&L PCC 1:5:10 Type E2 using 40mm graded stone aggregate as in mass filling in two layer in sunken portion complete all as specified and directed
.M&L 50mm dia G.I pipe as in spout to drain out if any leakage occures in the sunken portion complete all as specified and directed
Note:(a) The work shall be carried out by the authorized applicator of Manufacturer by using modern techniques. The contractor shall also furnish warranty of quality, finish work and effectiveness of waterproofing treatment under this item for a periof of 8 years from the date of completion along with manufacturer warranty of material for the same period. (b) Height of bldg may be more than 10 meters and roof have continous series of trapizium with no staircase to reach at the top of the building (c) The contractor shall have MOU with any one of manufacturer and also with their authorised applicator mentioned in the tender. Authorised applicator shall have valid authorisation letter from the manufacturer (Minimum regional HQs) and shall have been issued not less than 30 days from the date of commencement of the work. The authorisation letter needs to be valid for the complete period of execution work. (d) After preparation of the surface, Engr-in-Charge shall approve the same before applying finishing coats. (e) Building wise stage passing register shall be maintained and shall be signed by Engr-in-Charge and contractor. (f) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. (g) Contractor shall submit approved company generated 8 years warranty card at the time of submission of Final Bill.
Demolition of brick/stone masonary built in cement mortar incl all quoins arches pillars etc complete all as specified and directed
M&L for brick work with sub-class B bricks straight or curved on plan exc 6 Mtr mean radius built in CM (1:6) complete all as specified and directed
S&F in replacement of 3-in-1 wall mixer with provision for overhead Shower with 115mm long bend pipe on upperside, connecting legs & wall flanges made of cast copper alloy, chromium plated fancy type, complete all as specified and directed. Make : Hindware(Cat No-F390020)/ Cera(F1003401)/ Prayag(Cat no-8175Niagara) or equivalent
S&F of toughned glass corner shelves Shelf of size 300x300 mm fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed
Preparing newly plastered surfaces of new wall and applying two coats of weather proof exterior grade emulsion over and including a coat of primer complete all as specified and directed.
Complete removal of exisiting treatment, washing and rubbing of old surfaces of wall and applying two coats of weather proof exterior grade emulsion over and including a coat of exterior grade cement based primer complete all as specified and directed.
M&L 75 mm thick cement concrete type C2 1:3:6 (using 40 mm graded stone agg) in sub base of flooring/ hard standing complete all as specified and directed
M&L for factory made PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of PVC moulded (or rubber mould) with vibrating system, with and including 50mm thick sand cushioning, including in CM (1:3) in edges of pavers, complete all as specified and directed. Note : The cost of sand cushion is measured and paid separately.
M&L for sand filling under floor or in foundations incl watering and consolidation, complete all as specified and directed
M&L for PCC Type B-1, 1:2:4 (20 mm graded Stone Aggregate) , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, kerb stop rounded or chamfered in edges complete all as specified and directed
Excavating in trenches not exc 1.5m wide & not exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes etcand getting out Hard/dense soil complete all as specified and directed
Excavating in trenches not exc 1.5m wide & exc 1.5m and not exc 3.0m depth for foundation etc or for shafts, wells, cesspits, manholes etcand getting out Hard/dense soil complete all as specified and directed
Demolition and breaking of drains pipe (Salt glazed stone were, AC or reinforced concrete) set in cement mortar 150/200 mm internal dia pipe complete all as specified and directed
M&L DWCPE pipe 150mm dia complete laid in trenches including earthwork, removal and return filling and jointed including testing alongwith necessary jointing material tees/ union / socket etc complete laid on PCC bed 150 mm thick PCC in 1:3:6 type C-1 of avg depth 2.0 m including packing under and haunching against the side of pipes after they are laid and tested all as specified in IS 16098:2013 complete all as specified and directed
M&L DWCPE pipe 200mm dia complete laid in trenches including earthwork, removal and return filling and jointed including testing alongwith necessary jointing material tees/ union / socket etc complete laid on PCC bed 150 mm thick PCC in 1:3:6 type C-1 of avg depth 2.0 m including packing under and haunching against the side of pipes after they are laid and tested all as specified in IS 16098:2013 complete all as specified and directed
Returning / filling in incl spreading, levelling, watering and well ramming in layers not ext 250mm of Hard/dense soil complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not ext 1.5 m complete all as specified and directed
M & L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm internal dia of pipe complete all as specified and directed
M & L Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs set in cement mortar 1:6 complete all as specified and directed
M&L PCC 1:4:8 type D-2 ( with using 40mm graded stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed
Providing and fixing SFRC (Steel fibre Reinforced Concrete) cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter confirming to IS-12592, total weight of cover and frame not less than 182 Kg fixed in cement concrete 1:2:4 type B-1 using 20mm garded stone aggregate complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, as in hard/dense soil including removal of surplus soil to a distance not exc 50m complete all as specified and directed.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L mild steel work as roof trusses (framed) trussed, purlins, crane gantries ,rails and fastenings and heavy brackets framing (beams, tee, angle, channels or flat sections) etc confirming to Fe 410-W (Gde E - 250) quality -B complete all as specified and directed .
M & L filleting of section exc 25 Sqcm but not exc 50 Sqcm in any position to any shape in cement mortar 1 : 4 including excavation and earth work with all mitres, stops etc complete all as specified and directed.
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc including provision of electrogalvanised steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
One light point controlled by one switch
One exhaust fan controlled by one switch
One ceiling fan controlled by one switch and one regulator
One bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item no. 140 here-in-before but with 4.0 sq mm FRLSH copper wire with 4.0 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 10 sqmm + 1 run x 10 sqmm with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 142 here-in-before but 2runsX6 Sqmm +1runX6Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 142 here-in-before but 2runsX4 Sqmm +1runX4Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Notes for item No. 140.00 to 144 (i) Quoted rate shall deemed to incude the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & caping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing caping may be used in that portion.
S&F, Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F, Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F, Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F, Socket, two-in-one, 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F, angle holder, metal cased, bakelite body, 240 volts, complete all as specified and directed.
S&F, bell push Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F electric bell of DINGDONG type, 240 volts, single pole and making all necessary connections, complete all as specified and directed.
Supply and fix electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F, Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
S & F 7W White LED retrofit lamp suitable for B-22 holder base with polycarbonate diffuser and aluminium heat sink complete all as specified and directed.
Supply and fix in replacement of integrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fix LED building security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP 65degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of LED bulkhead luminaire 10W in die-cast aluminium alloy/ PVC body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 25A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB / MCB distribution board, VTPN, 4 way with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCCBs / MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix MCB distribution board, SPN, 12 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix MCB distribution board, SPN, 4 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix MCCB, 125A, 16 KA, 4 Pole with fixed thermal and magnetic setting complete all as specified and directed.
S& F MCB TPN 63 Amp, 10 KA, 'C' curve, 230 V, 50 Hz complete all as specified and directed.
S& F MCB SPN 40 Amp, 10 KA, 'C' curve, 230 V, 50 Hz complete all as specified and directed.
S& F MCB SP 6 to 32 Amp, 10 KA, 'C' curve, 230 V, 50 Hz complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 35 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 16 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing service cable of any description complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Taking down ceiling fan of any size carefully, sealing cable end, dismantling blades and removing fan and blades to store for servicing including supply, replacing bearings/bushings, capacitor and terminal connector including capacitor holder suitable for any model of existing fan, Painting of ceiling fans complete, with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc and Hanging ceiling fan in its existing or new location or deposited to E/M store yard as per site requirement and connecting up including provision of 3 core flexible copper conductor cable 0.5 sqmm from ceiling rose or connector to fan and testing for satisfactory functioning complete all as specified and directed by Engineer-in-Charge. Note :- If winding of ceiling fan is found burnt it shall be deposited to EM store yard for winding and same shall be measured and paid seperately. After rewinding the fan shall be fixed at site as per directions of Eng-in-Charge.
All as per item No. 173 here-in-before but of exhaust fan of any size up to 380mm sweep. Note: Rewinding if required shall be measured and paid separately.
Material and labour for Rewinding of Ceiling Fan of size 1200mm / 1400mm sweep by shifting to E/M Yard, cutting and removing of old burnt/damaged winding( Al/Cu), cleaning of slots and other parts and rewinding the ceiling fan motor with super enameled copper winding wire of existing gauge with suitable class of insulation, applying varnish, heating, drying, assembling and testing for satisfactory performance complete all as specified and directed by Engineer-in-Charge. Note :- The work is to be carried out in E/M store yard to the entire satisfaction of Engr-in-Charge
All as per item No. 175 here-in-before but exhaust fan of size up to 380mm sweep.
Supply and fix in replacement of Hot Press Molded SMC meter box of size not less than 700mm x 480mm x 210mm for accommodating 04 Nos of Single Phase energy meters including cutting the wall surfaces for flush mounting of meter box and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. complete all as specified and directed.
Supply and fix ceiling fans (BLDC Type), complete with three blade, down rod, accessories 230V, 1200mm sweep, BEE star rated complete all as specified and directed by Engineer-in-Charge.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
S & F MS clamp made out of 75mmx5mm flat with 20mm bore hole for taking branch connection with and including fixing of 25mm bore GI socket duly welded and fixing the clamp on existing GI/DI/CI pipe line of size 80/100mm dia with suitable rubber gasket packing to ensure leak proof joint, including nut, bolt and washers etc complete all as specified and directed.
FTH Traders
M/S BABA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .