| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC 53 A KAKURGACHI ROAD KOLKATA 700054 | KOLKATA | KOLKATA | WEST BENGAL | 700054 | ₹1.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.9 LRejected-Finance | ₹1.9 L | L2 | Rejected-Finance Rejected |
| 3 | L3₹2.0 LRejected-Finance 332 RABINDRASARANI BANKURA | BANKURA | BANKURA | WEST BENGAL | ₹2.0 L | L3 | Rejected-Finance Rejected |
| 4 | L4₹2.0 LRejected-Finance VILL CHANDANA PO KHATRA PS KHATRA DIST BANKURA | KHATRA | BANKURA | WEST BENGAL | 722140 | ₹2.0 L | L4 | Rejected-Finance Rejected |
| 5 | L5₹2.0 LRejected-Finance | ₹2.0 L | L5 | Rejected-Finance Rejected |
Tender Value
₹2.0 L
EMD Value
₹4,002
Closing Date
6 Feb 2026, 2:00 pmClosed
Executive Officer Sabang Panchayat Samity
Sabang Panchayat Samity
INSTALLATION OF HIGH MAST LIGHT IN FRONT OF KHALAGERIA PRIMARY SCHOOL MOUZA KHALAGERIA JL NO-164 PLOT NO-46/249 UNDER DANRRA GP WITHIN SABANG PANCHAYET SAMITI
2026_ZPHD_991601_4
WB/PMZP/SBG/NIET-52/2025-26
Open Tender
CIVIL WORKS
180 days
DANRRA
Please refer Tender documents.
2 documents required · 2 mandatory
₹750
₹4,002
Yes
9 Mar 2026
20 Jan 2026
9 Feb 2026
20 Jan 2026
6 Feb 2026
20 Jan 2026
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
Suppling fitting fixing 16 Amp Analog Timer in Pillerbox
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
Excavation of soil for installation of Earth Electrode and filling & ramming.For soft soil
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (s) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
Supplying, fitting and fixing 1.1 KV 4 sq mm 2 core PVC insulated amounted Aluminium conductor cable for hanging make-Havells/Polycab/KEI/Gloster
Supplying and delivery at site of 11 mtr GI octagonal pole including arrangement of monkey ladder, arms fixing with octagonal cross section and gradually tappered with single longitudinal welding. Total length of poll will be 11 mtr, thickness of sheet should not be less than 3mm, diameter of the pole at bottom and top will be 340 mm and 150 mm respectively, base plate 520 X 25 mm. Pole shafts shall be provided with fixed flange plate of minimum 16mm thickness with a provision of minimum 4nos fixing foundation hot dipped galvanised bolts. All other hardwares i.e. nuts and bolts, washer, spring washer, flats, split pin etc should be hot dipped galvanised. (UTKARSH/BPP/CG/BAJAJ as approved make.
Supplying and fixing LED flood light luminaries 150W LED (IP65 with efficiency > 100 Lumen/Watt and < 20% Lumen depreciation over minimum 2 years) with pressure die cast Aluminium housing and heat resistant toughened flat glass complete approved make with constant current LED driver. Make-Crompton or equivalent make of Phillips/Havells/ Bajaj
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (a) For 2 core upto 4 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (i) 2 core 4 sqmm cable
Supply and fitting of Powdercoated pillar box made of 3 mm th. MS Sheet as per Direction, 450 mmx300 mm cement brick foundation including excavation as per direction of EIC having single leaf and outer door with hinge locking arrangement oparated through allen Key incl. painting 16 A DP -1 No suitable rating of contactor and incl. fixing of 16 A switch and socket one set inter connection of above make accessories with suitable standard copper wire with socket,lugs ,gussket ,glands -1 set circuit diagram of controllpanel or feeder pillar box to be submitted before fixing of materials (MCB/L&T/ABB/SIEMENS/SCHEINDER)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by through Saturation with water,ramming complete including the cost of supply of sand (Payment to be made on measurement of finished quantity)
Cement concrete with Graded Stone ballast(40mm. Size) Excluding shuttering,if any ground floor(A) Pakur Variety(a)1:3:6
Ordinary cement concrete(mix 1:1.5:3) with graded stone chips(20mm nominal size)excluding shuttering and reinforcement if any, in ground floor as per relevant IS Code
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 25 mm to 30 mm shuttering without staging in foundation
Display Board made of plan of GI Shet 4 mm th,Supplying fitting & fixing at site,size 750 mm x 600 mm
Labour Cess 1%
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.57 MB
BOQ_2424641.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid