| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.2 LAccepted-AOC | L1 | Accepted-AOC Quoting Lowest rate | |
| 2 | L2₹55.2 L+₹2.0 L (3.67%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹67.0 L+₹13.8 L (26.0%)Rejected-Finance VILL ADHARMANIK P O BASUDEVKHALI P S BERHAMPORE DIST MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | 742101 | L3 | Rejected-Finance Quoting Higher Rate | |
| 4 | Rejected-Technical | - | Rejected-Technical Insufficient Documents |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
26 Dec 2023, 3:00 pmClosed
Superintending Engineer,Western El.Circle,PWD
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
SITC of Air Conditioning arrangement at different clinical area of Burdwan Dental College and Hospital, Purba Bardhaman.
2023_WBPWD_619598_1
WBPWD/SEWEC /BED /NIQ-86/2023-24_2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Purba Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.3 L
Office of the Superintending Engineer, Western Ele
7 Jul 2025
11 Dec 2023
28 Dec 2023
11 Dec 2023
26 Dec 2023
14 Dec 2023
11 Dec 2023 - 13 Dec 2023
13 Dec 2023
Amount
Supply, Installation, Testing & Commissioning of Split type AC machines having Cooling Capacity range (6.6 kw - 7.0 kw) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V,50Hz [ (+-)Tolerrance as per applicable standard ], both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc (Make- Mitsubishi Electric/ Mitsubishi Heavy Duty/O General ) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) P2 protected capacitor must be included in each RAC. iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor.
Supply, Installation, Testing & Commissioning of split type AC machines having Cooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V,50Hz [ (+-)Tolerrance as per applicable standard ] both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc (Make- Mitsubishi Electric/ Mitsubishi Heavy Duty/O General ) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) P2 protected capacitor must be include each RAC. iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor.
Supply, Installation, Testing & Commissioning of split type AC machines having Cooling Capacity range (8.72 kw - 8.79), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V,50Hz [ (+-)Tolerrance as per applicable standard ] both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc (Make- Mitsubishi Electric/ Mitsubishi Heavy Duty/O General ) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) P2 protected capacitor must be include each RAC. iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor.
Supply, Installation, Testing & Commissioning of split type AC machines having Cooling Capacity range (3.35 kw - 3.6 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -2/3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V,50Hz [ (+-)Tolerrance as per applicable standard ] both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc (Make- Mitsubishi Electric/ Mitsubishi Heavy Duty/O General ) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) P2 protected capacitor must be include each RAC. iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor.
The scope of work of above AC machines also includes supply of the following and others to be supplied with the machine
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and MS outdoor unit, duly painted, Labour charge for cutting of brick wall as per requirement with proper safety and mending good the damages to original finish incl. removal of rubish for installation of AC as per direction of EIC & Charging the extra refrigerant as required as per direction of the EIC. Sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand, Cement Plastery and painting (both inside & outside ) to match up with the original mending good the damages the complete the instn. & cutting of ms grill of window/wall (if needed) and mending good the damages incl painting also scaffolding arrangement as per requirement of all complete as per direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following HVAC grade nominal size of soft copper refrigerent piping [ Make Royku / Totaline/ Mandeep ] for RAC system, complete with fittings with adjustable ring type hanger supports, jointing/brazing after bending, swerazing, welding complete with fittings, elbows, bends, globe valve of suction & liquid line supporting arrangement on walls including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber [ Make Supreme/ Aroflex ] tubular sleeves sections of specified thickness as given below for suction and liquid lines with supports & brackets as per direction of EIC all accessories according to specification etc. as required.
5/8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) with tube thickness 0.6 mm mm incl. 13 mm thick insulation.
3/8" (9 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) with tube thickness 0.6 mm incl. 13 mm thick insulation.
1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22) with tube thickness 0.6 mm incl. 13 mm thick insulation.
1/2" (12.7 mm) dia (Soft drawn) Cu. Pipes (As per standard ASTMB-280,EN-12735 ) with tube thickness 0.6 mm incl. 13 mm thick insulation.
Wrapping the copper pipe, insulation, cable by 26 SWG aluminum sheet to make it vermin proof and all accessories as per specification etc. as required.
Supply & laying of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Supplying, fitting and fixing 40 mm dia PVC pipes of approved make of (medium duty) with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect and two coats of painting with approved paint in any position above ground - for water drainage system of AC machine. [For Exposed Work]
Dismantling the existing split type AC machine (1.5/2.0 Ton) along with the outer cover carefully by skilled labour from its position for necy. Servicing /overhauling incl cleaning the dust ete. due to dismantling operation and also Uninstalled & removing of unused old damaged windows AC unit from wall and covered the vacant space by gymsum board with necessary dimension with good mending and damages as per direction of EIC as per direction of E.I.C.
Supply & delivery of Multi-function Monochrome Laser Printer (Make - HP, Model : LaserJet M1005 Epson / Canon) including supply delivery of additional two nos. of genuine Cartridge and Dust Cover for printer unit. Printer type: Monochrome Laser; Functions: printer/scanner/copier; Printer Output: Monochrome; Connectivity: USB.
Supply & delivery of Computer UPS. Make: Emarson/Avo/Numeric
SITC of: Desktop Computers with the following Configuration: Processor: Intel Core i5 (10 Cores, 3.20Ghz or higher Base Frequency, 12 MB Cache, Chipset: Intel Q370 or higher, 2 DIMM slots or higher and minimum 4 PCle series expansion slots; RAM: DDR4, 8(1x8) GB 3200 MHz or Higher with support for expansion upto 32 GB; Storage : 256 GB PCIe NVMe M.2 SSD + HDD : 1 TB 5400 rpm SATA HDD; Integrated Graphics: Intel Iris Xe Graphics or higher; Operating System: Windows 11 64Bit preloaded with latest built in along with recovery media with Microsoft Office Pro (64bit) latest version & Quick Heal Total Security Antivirus single License for 05 Years; Connectivity: Integrated Dual Band Wi-Fi 802.11 a/b/g/n/ac & Bluetooth 4.2 Combo or higher; Display: 21.5 inch or higher, Full HD Or Better, Antiglare, Non-Touch, LED-backlit Monitor; 178° vertical / 178° horizontal Display Viewing Angle, Monitor stand should be height adjustable; should have at least one VGA, one Display port.
One HDMI port and four USB ports; Audio: Integrated Audio controller with Internal speaker; Keyboard: Standard Keyboard; Mouse: Optical Scroll Mouse; USB Integrated USB Port: Minimum 8 nos. (Min 4 nos of 3.1 Gen-1), out of 8 Nos |minimum 4 in front, 4 in back and should be easily accessible, ISO 9001 and 14001 Certified for OEM India Inclusive of MOUSE Pad, Dust Cover. Warranty - 03(Three) years onsite comprehensive OEM warranty with parts and service from the date of final bill completion ( Make Dell / HP / Lenovo / ASUS )
Lyric International
SRIDAM MONDAL
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .