RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Solar Water Heating System ( 2 pieces ) Technical Specifications 1/6 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment * BIS Approved Yes Yes
RequiredNo If Yes
RequiredMention CM/L No. otherwise write NA - * Model Number of Solar Water Heater System - * Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with Heat Exchanger Solar water Heating System with Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C * Rated Capacity in Litres per Day (LPD) 500 500 Warranty (Years) 1 Year 1 Year
Required5 Years CONSTRUCTIONAL Aperture area of collector
RequiredSq. Meteres (Sq Meter) 1.8 1.8
Required3.6 Electrical Heater ( Back up ) Capacity (kw) 9 2
Required9 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) 10.0 5.0
Required10.0 Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes * Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum Solar Transmittance for cover plate at normal Incidence (%) 92 * Material for Collector Box CRCA Aluminium
RequiredCRCA Numbers of collectors - * 2/6 Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based * Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based * Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based * Thickness of Sheet for entire body >/= 1.0 mm for aluminium based * CRCA Material Thickness >/= 0.91 mm for CRCA * Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa * Number of absorber sheets per collector - * Numbers of Header Tubes - * Numbers of Riser Tubes - * Diameter of Header Tube (mm) >/= 24.5 mm * Diameter of riser tube (in mm) >/= 11.5 mm * Thickness of Header Tube (mm) >/=0.71 * Thickness of Riser Tube (mm) >/= 0.56 mm * Material of Riser Header for Absorber Copper Only * Distanace Between Risers from center to center (mm) >/= 120 (mm) * Material of sheet for absorber Copper Copper Collector Box Insulation Back and sides * Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km * Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km * 3/6 Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes * Material for Hot water storage Tank Cold Rolled Steel (other material as per MNRE Notification year2011) Cold Rolled Steel (other material as per MNRE Notification year2011) Name the Material if choose others - * Non Pressure Type Hot water Storage Tank Yes * Position of Hot water tank Horizontal * Thickness of sheet of Hot water tank (mm) - * Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 * Hot water Welding MIG * Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint * Thickness of Coating (micron) - * Tank stand Material Mild Steel * Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes * Type of Heat Exchanger cage Type * Material for Heat Exchanger Copper Copper Thickness of tube of heat Exchanger
RequiredMinimum 22 SWG Yes * Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity * Numbers of Electrical Heaters ( Back Up Type ) provided 5 5 Collector Stand Material Mild steel * 4/6 Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes * System Interconnecting Pipes material Other Material * if other mention the Material for interconnecting pipes - * Size of interconnecting Pipes (mm) - * Tank test Pressure (bar) 2 * System Working Pressure (Bar) 2 * Inlet and Outlet Valve Yes * Temp Gauge( for Hot Water ) Yes * Gun Metal Strainer ( for Cold Water ) Yes * Water Meter Yes * Gasket for Flanges Synthetic gasket used between flanges * Electrical Back up Control panel Yes * Make of Control Panel Others * if others
Requiredmention the make of Control Panel - * Weight of solar water heater system (kg) 450 * CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools
RequiredPart 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes * Test Report No. - * Test Report Date - * Name of the Lab - * Address of the Lab - * 5/6 Availability of Schematic Drawing Yes * Instruction Manual for installation
RequiredRepair and maintanance Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.