| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.9 L+₹94,720 (5.58%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC L2 | |
| 3 | L3₹18.7 L+₹1.7 L (10.0%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹19.3 L+₹2.3 L (13.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹19.4 L+₹2.4 L (14.2%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Jun 2022, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair to security light Street Light and connected items at Sewar Fort, Mallah Pump House, Parade Ground in Mil Stn Bharatpur
2022_MES_524206_1
8150/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
Yes
GE Bharatpur
₹40,000
Yes
18 Jul 2022
14 May 2022
20 Jun 2022
14 May 2022
11 Jun 2022
28 May 2022
17 May 2022 - 25 May 2022
Amount
Dismantling and taking down non functional/ unserviceable /energy inefficient street /security light fittings of capacity upto 200W existing and fixing after minor repair '' such as loose connection replacement of unsv parts, replacement of connector , cleaning of glass, replacement of gasket if required to existing / directed location complete all as specified and directed by Engineer-in-Charge. Note:The items required to be replaced to make the light functional shall be measured and paid searately as supply only under respective items.
Supply only LED surge protector 10 KV multiple type 2 surge arrestors with thermal monitaring device and connector,dual visual fault indicator for the discharge path of the supply voltage and control the phase
Supply only LED drivers rated voltage 12/24 volt maximum out put power 90 W typical efficiency 93% .
Supply only LED drivers rated voltage 12/24 volt max out put power 150 W typical efficiency 93% .
Dismantling old U/S GI bracket of any size & length complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down non functional/ unserviceable /energy inefficient street /security light fittings of capacity upto 400W existing complete all as specified and directed by Engineer-in-Charge.
Taking out old un-servicable/ faulty PVC armoured LT under ground cable of any size any core complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 M wide but exc 1.5 M in depth for pipe line/pole, etc in soft / loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L Protection to cable with one layer of bricks laid flat abutting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge. (Note: the gap between two adjustable bricks should not be exceed 10 mm )
M&L Un washed dry river sand as cushioning of under ground cable (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) and punned after laying complete all as specified and as directed by Engineer-in-Charge. Note: Only punned thickness will be measured
M&L for cement concrete 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foudation,filling and mass concrete complete
M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles/ coping including necessary formwork, fair finishing to exposed surfaces using extra cement.
S & F street light GI bracket of 1.2 mtr long made out of 40mm dia light grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of flat iron 40 x 6mm including nuts bolts & washers for fixing on wall pole complete all as specified as directed.
S & F in replacement PVC insulated and PVC sheathed cable with aluminium solid conductor of size 4 SqmmX2 core from over head ACSR conductor/junction box to street light fitting complete all as directed by Engineer-in-charge.
S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 40mm bore complete all as specified and as directed by Engineer-in-Charge.
S&F and laying cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm X 4 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.(Note: :- (i) Necessary excavation and earth work, brick protection, sand cushioning and cover and GI pipe shall be measured and paid for separately.)
do but size 10 sqmm X 2 core
Supplying, errecting and fixing steel tubular swaged poles with MS base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. incl taking out old unsv PCC Pole. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with terminal incl Aluminium bus bar of 63amp-04 Nos and MCB SP 6amp-01 No of make sintex/Universal/Hansel inlc taking out old unsv any type..
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts (Surge protection of the light should be 10 KV )with suitable drivers etc complete all as specified and directed. Make:- Crompton / Philips/Bajaj/Havells.
Ditto all as per item No 24 here-in-above but 90 watt LED fittings.
Ditto all as per item No 24 here-in-above but LED flood light fittings 150 watts 230 volt complete and all assy duly prewired and pressure die cast aluminium housing,heat resistant tough glass with frame,IP 66 protection and better optic for uniform distribution. Make:- Crompton / Philips/Bajaj/Havells
Supply and fixing of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc complete as reequired.Make: AXXON/HAVELLS/PHILLIPS/CG incl taking out old Unsv light any type of size. Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. (Excavation & earth work shall be measured separately)
S&F in replacement MCCB 04 pole 100 Amp, Thermal magnatic, breaking capacity not less than 25KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420055 in Legrand or equivalent makes mentioned in Appex 'B')
S&F in replacement MCCB 04 pole 160 Amp, Thermal magnatic, breaking capacity not less than 25KA,415 volts complete all as specified and as directed by Engineer-in-Charge. (Cat Part No 420057 in Legrand or equivalent makes mentioned in Appex B)
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 2.25 Mtr below the ground level with the top edge of earth plate, depth not less than 1.65 Mtr below the ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates with 8mm dia bars@ 15cm reinforcement bars both way and on handle of 10 mm dia MS roundbars complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus site and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip.
M&L for road cutting in 300mm width & 450mm depth & repair to existing with bitumen premixed incl 150mm WBM complete all as specified and as dirceted
M&L for painting on steel pole initially scraping deteorated paint by emery paper and complete removal of rusted suface, painted with one coat of red oxide zinc chrome primer on exposed prepared surface and providing 03 Nos of 30 cm wide circular bands with black and yellow ( Two Coats)paint starting from bottom level at a gap of 30 cm in between 2 bands and numbering of pole with yellow paint over black painted background at the height of 02 meter from the bottom of pole with 02 cm larger Bold letter of height 2 inch wide complete all as specified and as dirceted
PD GUPTA AND COMPANY
GLOBAL ENGINEERS AND INNOVATORS
M/S NAVIN & ASSOCIATES
krishna Associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .