Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.9 CrAccepted-AOC | ₹3.9 Cr Quoted ₹4.1 Cr | 1 | Accepted-AOC Awarded |
| 2 | 2₹4.2 Cr+₹8.4 L (2.04%)Rejected-Finance 62A OFFICER COLONY AZAD NAGAR HISAR 125001 | HISAR | HARYANA | 125001 | ₹4.2 Cr+₹8.4 L (2.04%) | 2 | Rejected-Finance Not Awarded |
| 3 | 3₹4.0 Cr−₹13.8 L (3.33%)Rejected-Finance R O VPO GHASWA DISTRICT FATEHABAD HARYANA 125051 | FATEHABAD | HARYANA | 125051 | ₹4.0 Cr−₹13.8 L (3.33%) | 3 | Rejected-Finance Not Awarded |
| 4 | Rejected-Technical FATEHABAD | - | - | Rejected-Technical The bidder does not fulfill the criteria of executing similar nature of works as per the tender condition |
| Sl No | Description | Qty | Unit | Shishpal Govt. Contractor L3 | Gurdeep Singh Contractor L1 | SHREE RAM BUILDERS L2 |
|---|---|---|---|---|---|---|
| 1.00Item Description | ||||||
| 1.01 | RECOVERY OF OLD STEEL | 500 | Kg. | 42 ₹-21,000 | 28 ₹-14,000 Lowest | 36.5 ₹-18,250 |
| 1.02 | Supply and installation of 20W, 220V, 6500K, LED tube light.
Make: Havells / Philips / Bajaj | 7 | Each | 500 ₹3,500 | 145 ₹1,015 Lowest | 400 ₹2,800 |
| 1.03 | Supply and installation of 12W, 220V, 6500K, AC round shape LED bulb.
Make: Havells / Philips / Bajaj | 19 | Each | 200 ₹3,800 | 125 ₹2,375 Lowest | 200 ₹3,800 |
| 1.04 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt). Supplying, Installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency greater than 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%, THD less than 10% as per IEC 61000-3-2, P. F.greater than or equal to 0.95, IP-66,IK-10, CRI greater than or equal to 70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 70 Watt. (DSR2025- 8.16.2) | 26 | Each | 1,200 ₹31,200 Lowest | 1,900 ₹49,400 | 1,800 ₹46,800 |
| 1.05 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt)
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency greater than 85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%,THD less than 10% as per IEC 61000-3-2, P. F. greater than or equal to 0.95, IP-66,IK-10, CRI greater than 70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
72 Watt (DSR2025- 8.13.13) | 31 | Each | 1,800 ₹55,800 | 1,800 ₹55,800 | 1,500 ₹46,500 Lowest |
| 1.06 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt)
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency greater than 85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%,THD less than 10% as per IEC 61000-3-2, P. F. greater than or equal to 0.95, IP-66,IK-10, CRI greater than 70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
45 Watt (DSR2025- 8.13.11) | 13 | Each | 1,200 ₹15,600 Lowest | 1,450 ₹18,850 | 1,250 ₹16,250 |
Tender Value
₹4.5 Cr
EMD Value
₹9.0 L
Closing Date
8 Jun 2026, 2:00 pmClosed
AMIT DUA
District office Hisar
Construction of 10427 MT Capacity Godown (without roofing) with E.I. work, CC road, Labour toilet block with septic tank and soak pit, Water tank and Injection well after dismantling of existing NCP at Hafed Complex Sehnal road Ratia (Fatehabad).
2026_HBC_524731_1
20268B4BFCB9 7CF9 475A 9EE3 BECF1EEF330058HAF
Open Tender
Civil Works
Works
240 days
Ratia
2 documents required · 2 mandatory
₹15,000
₹9.0 L
Yes
7 Sept 2026
27 May 2026
8 Jun 2026
27 May 2026
8 Jun 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Item Description | |||||
| 1.01 | RECOVERY OF OLD STEEL | 500 | Kg. | 100 | ₹50,000 |
| 1.02 | Supply and installation of 20W, 220V, 6500K, LED tube light.
Make: Havells / Philips / Bajaj | 7 | Each | 100 | ₹700 |
| 1.03 | Supply and installation of 12W, 220V, 6500K, AC round shape LED bulb.
Make: Havells / Philips / Bajaj | 19 | Each | 10 | ₹190 |
| 1.04 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt). Supplying, Installation, Testing and Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency greater than 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%, THD less than 10% as per IEC 61000-3-2, P. F.greater than or equal to 0.95, IP-66,IK-10, CRI greater than or equal to 70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 70 Watt. (DSR2025- 8.16.2) | 26 | Each | 10 | ₹260 |
| 1.05 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt)
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency greater than 85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%,THD less than 10% as per IEC 61000-3-2, P. F. greater than or equal to 0.95, IP-66,IK-10, CRI greater than 70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
72 Watt (DSR2025- 8.13.13) | 31 | Each | 10 | ₹310 |
| 1.06 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt)
Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency greater than 85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5°C to 50°C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency greater than 85%,THD less than 10% as per IEC 61000-3-2, P. F. greater than or equal to 0.95, IP-66,IK-10, CRI greater than 70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) less than 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy greater than or equal to 120 and less than 135 lm/Watt output . LM79 and LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
45 Watt (DSR2025- 8.13.11) | 13 | Each | 10 | ₹130 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_603681.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .