Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC BALIJAN PANIHARA GAON PO DINJOY CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC aoc | |
| 2 | L2₹20.0 L+₹2.2 L (12.3%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹20.2 L+₹2.3 L (13.0%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹20.9 L+₹3.1 L (17.3%)Rejected-Finance SUDHA RANI VILA GROUND FLOOR 65 NASKAR PARA ROAD KOLKATA 700041 | KOLKATA | KOLKATA | WEST BENGAL | 700041 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹21.1 L+₹3.2 L (18.2%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹16.5 L
EMD Value
₹33,100
Closing Date
3 Jun 2022, 6:00 pmClosed
GE (AF) Mohanbari
Garrison Engineer AF Mohanbari Mohanbari Post Dibrugarh Assam 786012
SPECIAL REPAIR TO STATION ARMOURY AT AFS MOHANBARI UNDER GE (AF) MOHANBARI
2022_MES_522153_1
8001/367/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Mohanbari
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Mohanbari
₹33,100
Yes
1 Jul 2022
6 May 2022
6 Jun 2022
6 May 2022
3 Jun 2022
20 May 2022
Amount
Demolition of cement concrete (unreinforced) in ground floors and paving of any description not exc 15 cm thickness (below or above GL) including removing materials obtained from demolition from worksite outside MoD land any distance complete all as specified and directed by Engineer-in-charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete including removing demolished material from work site complete all as specified and directed by Engineer-in-charge.
Material and labour for plain cement concrete type B-1 (1:2:4), using 20 mm graded crushed stone aggregate, 25 mm thick , as in roof complete all as specified and directed by Engineer-in-charge.
Material and labour for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but nexc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over and including screed bed or bedding layer 15 mm thick in cement morter 1:4 for laying tiles complete all as specified and directed by Engineer-in-charge. ( Note: Screed bed shall also deemed to be included in the quoted rate by the contractor.)
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular, area of each tiles exceeding 0.18 sqm but not exc 0.38 sqm and , in floors set and jointed in neat cement slurry and pointed in white cement and pigment to match over 15 mm thick screeding in CM 1:4 complete all as specified and directed by Engineer-in-charge. ( Note: Screed bed shall also deemed to be included in the quoted rate by the contractor.)
Material and labour glazed ceramic coloured (Printed) tiles, 450 mm x 300 mm x 7mm thick, in dado skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match including rendering 15 mm thick in cement morter 1:3 for laying tiles complete all as specified and directed by Engineer-in-charge. ( Note: Rendering shall also deemed to be included in the quoted rate by the contractor.)
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over 20 mm thick screeding in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge. ( Note: Screed bed shall not be measured and paid separately).
Material and labour Machine cut Kota Stone slab 20-25 mm thick in riser of steps, skirting, dado and pilar laid over 15mm thick rendering in CM 1:3 and jointed with and and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.( Note: Rendering shall not be measured and paid separately).
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc.including removing of rubbished material from work site complete all as specified and directed by Engineer-in-charge.
Material and labour for rendering 15 mm (10+5) thick on fair faces of brick work or concrete surfaces, in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions complete all as specified top surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. (Note: WPC shall be measured and paid separately)
Material and Labour for rendering 10 mm thick on other than fair faces of brick or concrete surfaces finishing surfaces even and smooth without using extra cement in Cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
Material and labour for rendering 5mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:4 complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound ( liquid ) conforming to IS : 2645-2005 complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of new surfaces of wall by washing, rubbing down, with sand papering surface to achier smooth surface and applying two coats of distemper oil emulsion of any tent/ shade over a coat of wall care putty including washing of floors cleaning of glass, joinery, electrical fitting etc of drops complete all as specified & directed
M & L for Preparation of old decorative plastered surfaces of walls by washing, rubbing down, stopping of distempered & painted surfaces after complete removal of existing treatment and applying two coats of distemper oil emulsion of any tent/ shade over a coat of wall case putty including washing of floors, cleaning of glass, joinery electrical fittings etc of drops complete all as specified & directed
Material and labour for preparation of newly plastered surfaces of ceiling by brooming, rubbing down with sand papering of surfaces to achieve smooth surfaces and applying three coat of white wash including washing of floors cleaning of glass, joinery, clectrical fitting etc of drops complete all as specified & directed
Material and labour for preparation of old plastered surfaces of ceiling by washing, rubbing down, stopping of decorative surfaces after complete removal of existing treatment and applying three coats of white wash including washing of floors, cleaning of glass, joinery, electrical fitting etc of drops complete all as specified & directed
Material and labour for preparation of newly plastered surfaces of walls by brooming, scraping down, smoke, soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying minimum two coats of exterior emulsion paint 100 % acrylic, in camouflage pattern any tinted, including washing floors, cleaning of glass, joinery, electrical fittings wiring etc of drops complete all as specified & directed
Material and labour for preparation of old plastered surfaces of walls by brooming, scraping down, smoke, soot, moulds, moss and efflorescent salts and treating oil and greasy spots after complete removal of existing treatment and applying minimum two coats of exterior emulsion paint 100% in camouflage pattern any tinted, including washing floors, cleaning of glass, joinery, electrical fittings wiring etc of drops complete all as specified & directed
Material and labour for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed by Engineer-in-charge.
Taking down existing unserviceable treatment of any description including cement plaster, any thickness from roof surfaces, cleaning the roof surfaces and prep[aring it for further treatment and removing rubbish from site, complete all as specified & directed
Material and labour for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engineer-in-charge.
Material and Labour for water proofing treatment to RCC roof with 3 mm thick weight not less than 3.5 kg/ sqm APP modified polymeric APP based polymeric membrane non wooven polyster reinforcement without mineral finish to be laid by torch application method. On the dried surfaces applying one coat of approved bituminous primer @ 300 grms/ sqm with torch application laid with over laps of 100 mm joints of traverse direction and 75 mm at longitudinal direction, duly thermofused by flame torch flame application method and over & including 15 mm thick screed bed or bedding layer in cm (1:4) on concrete surfaces mixed with WPC @ 3% by weight of cement or as per manufacture instructions, finished the surfaces fair and finished including onecoat of aluminimum paint @ 0.11 kg/sqm over APP membrane complete all as specified and directed. Note: WPC shall be measured & paid separately.
Material and labour for plain cement concrete 1:3:6 ,type C2 , using 40 mm graded crushed stone aggregate, 75 mm thick as in path / plinth protection complete all as specified and directed by Engineer-in-charge.
Taking down Chowkhats or frames not exc. 1.5 sq.m each with shutters ( without taking off shutters from the frames) and making good disturbed surfaces including removing disposable materials from work site to outside MOD land at any distance complete all as specified and directed by Engineer-in-charge.
Taking down chowkhats or frames exc. 1.5 sq.m and n exc 4 sq.m. each with shutters ( without taking off shutters from the frames) and making good disturbed surfaces including removing disposable materials from work site to outside MOD land at any distance complete all as specified and directed by Engineer-in-charge.
Supply and fixing framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165 including taking down existing complete all as specified and directed by Engineer-in-charge.
Supply, fabricating and fixed rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening .grade Fe-410-W ( Gde-E-250) quality -B including dismantling of old rusted steel and removing from site complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and AC/PVC rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning for refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-charge.
Supply and fixing Mild steel sheet eaves gutters, 1.25 mm thick, 150mm dia., galvanised class 3, half round with rounded edges complete all as specified and directed by Engineer-in-charge.
Dismantling of roof sheets (corrugated, semi corrugated) in roof coverings including removing of unserviceable material from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Dismantling wall and ceiling boards ( fibre, pulp, insulation ,etc. ) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-charge.
S & F 4mm thick designer ceiling ( E- board classic) board/ tiles for insulating and acoustic purpose 595 x 595 mm size fixed with staples on snap grid as in ceiling with dusting of surfaces and applying two coats of oil bound distemper over a coat of primer including S & F of powder coated GI snap grid frame work for false ceiling comprising of the following section for making partition of 605 x 605 mm size fixed to wall with rowel plug & screws and hanged to roof with and including 2 mm dia GI wire suspended of suitable length and butterfly clips, size of main T and cross T section shall be 28X24X0.30 mm thick and wall angle shall be of section 24X24X0.30mm thick complete all as specified.
Material and labour for preparation of old decorative ceiling board/ tiles by washing, rubbing down and stopping of distempered and painted surfaces of ceiling applying one coat of distemper oil emulsion of any tint / shade including taking down and refixing of same in position complete all as specified and directed by Engineer-in-charge
Demolition Brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles including removing of demolished materialfrom work site complete all as specified and directed by Engineer-in-charge.
Material and labour for Brickwork with old size sub class 'B' locally available bricks, having compressive strength 75Kg/sqcm, straight or curved on plan exc 6 M mean radius built in cement and sand mortar 1:6 complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide primer including cleaning, stopping and rubbing down and removing all dropings etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted steel and iron surfaces of any description , not otherwise described ,over 10 cm width or girth and painting one coat with synthetic enamel paint including cleaning, stopping and rubbing down and removing all drops etc. complete all as specified and directed by Engineer-in-charge.
M&L 2nd Class Hard wood Plain , solid , straight chowkhats and frames , wrought , framed rebated on the solid , rounded or chamfered , put together with glue, pinned at joints, supplied and fixed including tarring back of chowkhats with tar or coal tar black paint complete all as specified and directed by Engineer-in-charge.
Material and labour for 35 mm thick, IInd class HW, factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) ,edges of framing plain,chamfered or rounded, fitted with cut and mitred beads for securing glass,etc;size of members of shutters as specified in SSR part-I, Section-8, clause 8.24 (a) supplied and fitted to chowkhats complete all as specified.complete all as specified and directed by Engineer-in-charge.
Supply and fixing 4 mm thick sheet glass, ordinary quality, in squares not exceeding 0.5 Sqm in each pane, glazed with oil putty complete all as specified and directed by Engineer-in-charge.
Supply and fixing for galvanised steel wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.0 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in-charge.
Supply and Fixing solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply & fixing in opening as per specification complete all as specified and directed by Engineer-in-charge.
Supply and Fixing Factory Made Solid PVC Door Shutter, 30mm thick (stiles),manufactured as per SSR para- I specification and drawing consisting of frame made out of MS tubes for top & bottom rails. MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for topail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail , paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rail with the suitable PVC sheet beading and jointed together with solvent cement & fixing in the frame at site complete all as specified & directed.
Material and labour for preparation of new untreated wooden /wood based materials surfaces of any description , not otherwise described, over 10 cm width or girth and painting two coat with synthetic enamel paint over a coat of pink primer including cleaning, stopping and rubbing down and removing all dropings etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted wooden /wood based materials surfaces of any description, not otherwise described, over 10 cm width or girth and painting one coat with synthetic enamel paint (1st quality) including cleaning, stopping and rubbing down and removing all dropings etc. complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal of unserviceable pipe from work site,15 mm bore of pipe complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal of unserviceable pipe from work site, 20 mm bore of pipe complete all as specified and directed by Engineer-in-charge.
Supplying, laying, jointing and testing 15 mm nominal bore of pipe, steel water tubes, 'medium grade' galvanised, with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Supplying, laying, jointing and testing 20 mm nominal bore of pipe, steel water tubes, 'medium grade' galvanised, with all fittings, fixed to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs, chromium plated fancy type Bib taps, cast copper alloy with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair CP stop cock fancy type, screwed down for 15 mm bore dia. pipe, high pressure, with crutch or butterfly handle , screwed externally both ends for unions etc. and fixed complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs,15mm dia pilllar tap cast copper alloy chromium plated with capstan head ,screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe (bore of pipe 15mm) complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mm (1st quality) including brackets, waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply pipe and supply of taps complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repair 9-10 Litres capacity Low level flushing cistern with (dual flush, ISI Marked embossed) valveless, syphonic action type, low level white with inlet, ball valve, float and handle complete including brackets and connection to pipe complete including dismantling of existing flushing cistern including flush pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs vitreous China white wash down water closet (padestal pattern) , plastic water closet seat, black, closed pattern with recessed bottom and cover and mild steel CP hinging device, polyethylene flush pipe of low or high density 32 mm dia for cistern complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-charge.
Material and labour for RCC NP3 150 mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of brick masonary/RCC/Precast RCC with SFRC ventilating cover and frame including making sewer line functional avg depth 1.5 m. complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 20 mm bore dia. pipe or brass ferrule complete all as specified and directed by Engineer-in-charge.
Dismantling PVC water tanks exceeding 250 litres but not exceeding 500 litres capacity, including removing ball valve and removing unserviceable tank from work site complete all as specified and directed by Engineer-in-charge.
Supply and fixed rotational moulded poly-ethylene multilayer water storage tanks ( cylinderical vertical with closed top ) 500 litres capacity ,hoisted and fixed in position (ISI Marked embossed) complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair toilet paper holder of CP brass screwed fixed with wall complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repairs Salt glazed stoneware gully traps, size 150 mm x 150 mm, square or round mouthed , type 'P' complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement, 75 mm dia. outlet complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair PVC (SWR) vent cowl 75 mm bore complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs for 75 mm bore PVC (SWR) pipes single socketed ISI marked IS-13592, type 'B' in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-charge.
Supply and fixing butt Hinges, medium weight, cold rolled mild steel, 100 mm size complete all as specified and directed by Engineer-in-charge.
Supply and fixing butt Hinges, medium weight, cold rolled mild steel, 125 mm size complete all as specified and directed by Engineer-in-charge.
Supply and Fixing aluminium handle cast type anodised 150 mm size etc complete all as specified and directed by Engineer-in-charge
Supply and fixing Aluminium, anodised, barrel tower bolts of extruded section and fixed, 200 mm length of bolt complete all as specified and directed by Engineer-in-charge.
Supply and fixing 300 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-charge.
Material and labour for coloured chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, set, jointed in neat cement slurry and pointed with grey cement mixed with pigment in treads including 20 mm thick screed bed/bedding layer in CM 1:4 complete all as specified and directed by Engineer-in-charge. ( Note: Screed bed shall not be measured and paid separately).
Taking down carefully aluminium/copper conductor point wiring (light, fan, socket or powerpoint) complete including batten, conduit and fittings such as switches,ceiling roses, sockets, switch board etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed by Engineer-in-charge.
Taking down carefully ceiling / exhaust fans, sealing cable end, dismantling blades and removing fan and blades to store and refixing back to its original position and making good to the disturbed surface wall / floors and matching to the existing color complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for light point/ fan point/ bell point, one light/fan/bell point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade including all accessories including sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover, cutting chases for concealed conduits/sunken boxes and making good of disturbed surface not exc 15 cm girth and 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire, 1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
All as per item No. 81 above but One 5 pin 5 Amps switch socket combination point on independent board
Material and labour wiring for 6 pin 15/16 Amp switch socket combination point on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade including all accessories including sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch, socket and fan regulator with 3 mm thick hylum laminated sheet cover, cutting chases for concealed conduits/sunken boxes and making good of disturbed surface not exc 15 cm girth and 2.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire, 1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour for point wiring for metal clad socket using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed (FRLS) cables,1100 volts grade single core in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade including all accessories including cutting chases for concealed conduits/sunken boxes and making good of disturbed surface not exc 15 cm girth and 4.0 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed (FRLS) earth wire, 1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring for flameproof light point/ fan point, one light/fan point controlled by one, 16 Amp one way flameproof switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS (flameproof low smoke) cables,1100 volts grade single core in and including 20 mm dia or higher size ERW steel concealed conduits and fittings such as bend, elbow, tee, junction box etc and making good of disturbed surface not exc 15 cm girth and 1.5 sqmm nominal cross sectional area multistranded copper conductor PVC insulated unsheathed FRLS (flameproof low smoke) earth wire,1100 volts grade single core and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed by Engineer-in-charge. (Note for Item 81 to 85 : Conduit shall run on surface in case of passing through ceiling/beam/column.)
Supply and fixing switch socket combination 2 in 1, 5 pin, multipurpose type, (5/6 Amps) piano flush type 230 Volts controlled by one switch complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch socket combination, multipurpose type, 6 pin , (15/16 Amps ) piano flush type 230 Volts controlled by one switch complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole , 5/6 Amps, one way single pole complete all as specified and directed by Engineer-in-charge.
Supply and fixing ceiling rose (ISI marked) three terminal, PVC/polycarbonate, isolated body, surface type, 230 Volt complete all as specified and directed by Engineer-in-charge.
Supply and fixing stepped type electronic fan regulator flush type 230 Volts, five speed control, ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch flame proof rotary type with termination box in LM6 , 16 A, single pole 250 volts complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair sheet metal enclosure single pole and neutral with two pin and earth plug and socket, 20 Amps, 230 Volts, 50 Hz complete with one single pole MCB 20 Amps 230 volt, 50 Hz complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Bell push Switch, piano flush type , 5 amp complete all as specified and directed by Engineer-in-charge.
Taking down existing unservicebale service main / sub main wiring complete all as specified from electric poles to service brackets, wall etc. including removing of unserviceable wiring complete all as specified and directed by Engineer-in-charge.
Supplying and fixing two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC concealed conduit (ISI marked), including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge. Note :- Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item).
Supplying and fixing two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVCconcealed conduit (ISI marked), including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed by Engineer-in-charge. Note :- Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item. Note for Item 95 to 96 :- Conduit shall run on surface in case of passing through ceiling/beam/column
Supply and fixing in repairs LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose. complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs LED light fittings with high output diffuser 2 feet, 10 watt, 220V, AC decorative type with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs recessed mounted CIMFR certified LED 1x16/20 watt flameproof batten suitable for single and twin T8 tube of 16W/20W. Recommended for gas/vapor group of IIA & IIB and zone 1 & 2. IP-65 protected including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs recessed mounted CIMFR certified LED 2x16/20 watt flameproof batten suitable for single T8 tube of 16W/20W. Recommended for gas/vapor group of IIA & IIB and zone 1 & 2. IP-65 protected including necessary connection complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED street light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp with impact and corrosion resistant, IP 65/66 protection including assembling of complete fitting and its testing before and after mounting or erection etc for proper functioning and taking down existing complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair GI bracket for street light made out of 25 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required, fixed to pole/wall with two coats of aluminium paint over a coat of red oxide primer including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed by Engr-in-charge.
Supply and fixed in repairs epoxy concealed powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 2 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs epoxy concealed powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs epoxy concealed powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed by Engineer-in-charge.
Supply and fixed in repairs MCB SP, 10 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 415 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed by Engineer-in-charge. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc or for trench for laying under ground cables, poles, stay assemblies etc and getting out in Soft/loose soil, making the surface plain complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc or for trench for laying Galvanised Iron pipes used for cable protection and getting out in Hard/Dense soil, making the surface plain complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and labour for disconnecting unservicable under ground LT cable of any size/type from existing pole or building or any location including removing of dismentalled material from work site complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying LT under ground XLPE cable of size 10 sqmm, 2 core including testing and commissioning insulated, screened, PVC bedded, armoured steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed by Engineer-in-Charge. Note:- Excavation,sand cushioning,brick will be measured and paid separtely.
All as per Item No. 113 above but size 25 Sqmm, 3.5 core
All as per Item No. 113 above but size 50 sqmm, 3.5 core
Supply and Laying sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23 cm (15cm under the cable & 8cm over the cable) and gently punned down to 18 cm thickness all complete all as specified and as directed by Engineer-in-Charge. Note : Only punned down thickness of sand shall be measured for payment.
Material and labour for well burnt brick sub class 'B' of size 230 x 115 x 75mm having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed by Engineer-in-Charge.
Supplying and fixing in repairs 25 mm bore, galvanised mild steel pipe /tubing, light grade complete with all fittings, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and as directed by Engineer-in-Charge. Note :- Excavation & Earth work shall be measured and paid separately)
All as per item No.118 above but 50 mm bore
Supply and fixing in repairs Air termination, single pointed, copper rod 12mm dia and 300mm long fixed on galvanised iron pipes with copper/aluminium/GI strip for earth conductivity to ground complete all as specified and directed by Engineer-in-charge. Note: MS/PCC work shall be measured and paid separately.
Refixing of old serviceable tilted Air termination rod of any size and type after straightening and dressing with and including suitable nuts, bolts and washers to earth strip including taking down existing complete all as specified and directed by Engineer-in-charge. Note: 1) MS/PCC work shall be measured and paid separately. 2) Nuts, bolts and washers shall be deemed to be included in the quoted rate
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to buildings / equipments / plants or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators with fixing screw including brazing and nut, bolt at joints complete all as specified and directed by Engineer-in-charge.
Refixing of old serviceable copper/GI/aluminium strips of any type and size after straightening and dressing and fixing in existing position with new saddle/connector /insulators with screw and making good disturbed strip including taking down existing complete all as specified and directed by Engineer-in-charge. Note: saddle/connector /insulators with screw shall be deemed to be included in the quoted rate.
Material and labour for brazing of broken/ loose connected copper strip of any size and type not exceeding 3.2 cm in length and not exceeding 6 mm in thickness including bringing of necessary machine at site complete all as specified and directed by Engineer-in-charge.
D N ENTERPRISE
S K ENTERPRISE
R K CHAKRABORTY AND CO
M/s PRABIR ENTERPRISE
M/s Sashi Enterprise
M/S S. P. ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .