Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.1 L+₹2.8 L (7.57%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.0 L+₹4.6 L (12.6%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹41.1 L+₹4.7 L (13.0%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹41.4 L+₹5.0 L (13.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
27 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
Addn/ Altn to Bldg No P-III at AFA Hyderabad
2022_MES_559605_2
8297/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) Hyderabad
As per tender documents
3 documents required · 3 mandatory
₹500
GE (AFA) Hyderabad
₹87,000
Yes
16 Mar 2023
10 Nov 2022
29 Dec 2022
10 Nov 2022
27 Dec 2022
12 Dec 2022
10 Nov 2022 - 23 Nov 2022
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete and removing servicable slabs to store and unservicable debris to a distance exc 1.5 km and non exc 5 km all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish to a distance exc 1.5 km and n.exc 5 Km all as specified and directed.
M&L for Cement concrete 1:3:6 type C1, using 20 mm graded stone aggregate laid in sub base, sub floors as padding concrete for levelling etc complete all as specified and directed.
M&L for Granite (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, laid over and including screed bed or bedding layer in cement mortar ( 1:6) 20mm thick complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick set and jointed in cement slurry and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer in cement mortar (1:6) 20mm thick for laying floor finishes complete all as specified.
M & L for glazed ceramic coloured tiles of size 450 x300x 7mm thick, in vertical surfaces of dado, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including rendering / backing coat 10mm thick in cement mortar 1 : 4 on fair faces of brick or concrete surfaces, rough finished to receive over wall tiling complete all as specified and as directed..
Taking down chowkats or frames with shutters exc 1.5 sqm but n exc 4 sqm each of any description, any material (without taking off shutters from the frame) complete all as directed
Taking down chowkats or frames with shutters n exc 1.5 sqm each of any description, any material (without taking off shutters from the frame) complete all as directed
S&F powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing complete all as specified
S&F of Pressed steel frames size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., not less than 1.25 mm thick complete all as specified and directed.
S&F 35mm thick second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial venneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated all as specified in Sl No.8.24 (a) of SSR Part I and as directed.
S&F of factory made 35 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F for 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats all as directed.
S&F powder coated aluminium door shutters, aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc, complete all as specified and directed (Powder coating should not be less than 50 micron)
S & F powder coated aluminium windows and ventilator shutters, sliding type, without sash bars aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips , rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as rollers, locking arrangement, handles etc complete all as specified and directed. (Powder coating should not be less than 50 micron)
S & F 12mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice lamination in aluminium doors/partition complete all as specified and directed
S&F of 5 mm thick sheet glass, ordinary quality and glazing in aluminium door frames with beading, not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 Sqm and in aluminium frames in each pane complete all as specified and as directed.
S & F of stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
M & L for prepartion of new wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F of 300mm mild steel , ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and directed.
S & F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F of Aluminium anodised,barrel tower bolts of extruded section of size 200 mm long complete all as specified and as directed.
S&F of Aluminium handles, cast type, anodised of size 200 mm long complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type)of size 300mm and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor overall length of cover plate 140 mm all as specified and directed,
S&F of Armstrong Ceiling Classic Lite 600x600x16mm, NRC-0.55, with grid size 600x600mm consisting of main tee 32x24mm @1200 c/c, cross Tee of 1200mm of size 27x24 mm and cross Tee of 600mm of size 25x24 mm and wall angle of size 19x19mm and fixed all around the wall to form a grid of size 600x600 ceiling tiles shall be inserted in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/C all as per manufactures instruction and as directed.
S&Fof Armstrong Suprafine Metal ceiling of 600x600mm panes 0.50mm thick with grid size 600x600mm consisting of main tee 32x15mm @1200 c/c, cross Tee of 1200mm of size 29x15mm size and cross Tee of 600mm length of size 27x15mm and wall angle of size 19x19mm and fixed all around the wall to form a grid of size 600x600 ceiling tiles shall be inserted in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/C all as per manufacturers instruciton and as directed.
Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removing serviceable materials to store and undserviceable debris to a distance exc 1.5 km and n.exc 5 km all as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil all as specified and directed.
M & L for 200 mm dia salt-glazed stoneware drain pipes laid in trenches and jointed set in cement mortar including demolition and breaking up existing drain pipe and removing debris to a distance exc 1.5 km and n.exc 5 km all as directed by Engr-in-Charge.
M&L for providing Cement concrete bed 1:4:8 type D-2 mix using 40 mm graded stone aggregate to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested of 200 mm bore pipe complete all as specified and as directed.
M & L for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete (1:3:6) complete all as specified and directed.
M&L for pre-cast cement concrete block masonry of Type C1 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4 aomplte all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement all as specified and directed
M & L Mild steel TMT bars 6 mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for Precast reinforced cement concrete (1:2:4 ) type B-1, (using 20 mm graded stone aggregate) as in cover slabs (for manholes, shelves etc)) set in cement mortar 1:6 complete all as specified and directed including demolition and removal of old covers of any description
M&L for providing Cement concrete 1:2:4, type B-1 mix using 20 mm graded aggregate as in coping, benching/channels including necessary formwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Returning, filling of excavated soil including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick all as specified and as directed.
M & L for PVC (SWR) gully trap 125/110 mm size,setting and jointing with solvent cement complete all as specified
Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) and making good the disturbed surface to match with existing complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC conduit of suitable size but not less than 20mm dia. and all accessories fixed to be consealed in wall & surface of the roof etc., including MS box made out of 1.2mm thickness with 3mm thick laminated sheet for fixing switches, fan regulators, socket outlets etc complete all as specified and as directed for the following:-
(a) One light point controlled by one switch
(b) One ceiling / Exhaust fan / Wall Fan point controlled by one switch
(c ) One 5A socket on independent board
All as per Ser item No-43 above but with 4 sqmm copper cable in and including PVC conduit for 15A socket complete all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal complete all as specified and as directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed.
M&L for Sub Main wiring with four runs of 06 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings on surfacs of walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly incl taking down old sub main wiring any type any size complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(iii) Five runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
M&L for Sub Main wiring with four runs of 16.0 sqmm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor 1100 Volts drawn through and including stove enamelled steel conduit of suitable size but not less than 40mm dia, with all fittings, on surfaces of wall / ceiling / roof duly fixed with fixing clamps including and duly earthed with 01 run of 16sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable green in colour as continuous earthing wire incl taking down old sub main wiring any type any size complete all as specified and directed by Engineer-in-Charge. Note :(i) Necessary stove enamelled steel conduit junction boxes for identifying junction as required on site/directed by Engr-in-charge for sub main wiring work with dummy plates shall deemed to be included in the quoted rate. (ii) 5 runs of 16 sqmm copper wire and one run of steel conduit shall be measured as one unit. (iii) The wiring shall be done strictly as per IS standard
M&L for Sub Main wiring with two runs of 06 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings on surfaces of walls/roof/floor duly earthed with 01 run of 06 sq.mm. (nominal area) single core PVC insulated unsheathed FRLS cable multi-stranded copper conductor cable but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(iii) Three runs of 6sqmm wire and one run of PVC conduit / casing caping will be measured as one uint.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using 4 mm GI wire connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of MES Schedule Part-I (2009) and all as directed. Note:
S &F in repair of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor all as specified and as directed. Note : Old ceiling fan to be deposited in E/M store yard
S & F in repairs exhaust fans with lowers of metal body AC single phase 230/ 240 V of size 380 mm sweep complete fixed to the existing opening on wall duly modifying the opening as required to suit the fan incl finishing the opening to match with existing finish complete all as specified and as directed. Note : Old exhaust fan to be deposited in E/M store yard
S & F storage type water heater, electric, capacity 50 ltrs, BEE 5star rating including adjustable thermostat, thermal cut off, heating element and insulated storage tank of 50Lts capacity including necessary fitting/ fixtures, hot water flexible pipe etc complete all as directed
S & F in repairs of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S &F in repairs LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof / ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed..
S&F of MCB DB 8 way SPN (in repairs) type 230 volts 50 Hz AC supply with suitable provision for MCB and fixed to the existing wall (concealed) and making good the disturbed surfaces of wall to match with existing wall complete all as specified and as directed. Note: MCB/ MCCB will be measured seperately
S&F of MCCB DB 4 way(in repairs) triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface wall to match with the exsting wall complete all as specified and as directed. Note: MCB/ MCCB will be measured seperately
S&F Fix MCB(in repairs) SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
S&F Fix MCB (in repairs) SPN 63 A 16 KA rupturing capacity complete all as specified and as directed.
S&F Fix Isolator (in repairs) TPN 63 A 16 KA rupturing capacity complete all as specified and as directed.
S&F Fix Isolator (in repairs) TPN 100 A 16 KA rupturing capacity complete all as specified and as directed.
S&F (in repairs) Plug and socket DB's with MCB and TPN suitable of 8 module for flush mounting with neutral link of capacity 32Amps (3P+N+E-FP). Complete all as specified and directed.
S&F (in repairs) Plug and socket DB's with MCB and TPN suitable of 8 module for flush mounting with neutral link of capacity 100 Amps (3P+N+E-FP). Complete all as specified and directed.
S&F (in repairs) Plug and socket DB's with MCB and TPN suitable of 8 module for flush mounting with neutral link of capacity 32Amps SPN 4 pole. Complete all as specified and directed.
Supply, fabricating and Fixing of GI Sheet of size 22 guage for fresh air ducting all as specified and directed
S&F of MS angles flanges of suitable size for duct of GI Sheet of size 22 guage all as specified and directed
S&F of double deflection aluminium grill with complete control damper all as specified and directed
Supply and Installation of AHU model fresh air Unit with 5 H.P motor 3 phase 50 hz AC 415 volt including 01 No Air filter with complete fixing/erection arrangement such as base plate/ angle iron , nut bolt and wahser with PCC 1:3:6 & civil work as required on site all as specified and directed
Supply and Installation of fresh air Unit with vibrator starter with complete fixing/erection arrangement such as base plate/ angle iron , nut bolt and wahser with PCC 1:3:6 civil work as required on site all as specified and directed
M&L for canvas cloth of suitable size for above AHU all as specified and directed
M&L for hardware threaded rods and complete packing materials for GI ducting all as specified and directed
Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm dia on walls/floors/ceiling etc complete all as specified and directed
Supply and lay pipe galvanized, “Medium class”, including necessary fittings 25 mm dia fixed on walls/floors/ceiling etc complete all as specified and directed .
S&F PPR Gate Valves (Brass Insert) of 25 mm bore all as specified and directed .
S&F PPR Gate Valves (Brass Insert) of 40 mm bore all as specified and directed .
S & F of Stop Valve, brass chromium plated, screwed for 25 mm dia pipe all as specified and directed .
S&F pressure pumps of size 0.50 HP of discharge range 2000 -3000 L/H for pipe size 25 x 25 mm incluing mounting iron base complete with nut bolt and washer all as specified and directed
Cutting into exisitng GI pipe line and providing equal Tee of 40 mm dia pipe with complete fixing arrangement all as specified and directed
M/S NAVEEN BUILDERS
S J REDDY
TARUN CONSTRUCTION COMPANY
M/s D.Krishna Varma
Hari Om Construction
Saiansh Associates
POWER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .