Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.3 L+₹20,157.89 (1.54%)Rejected-AOC SUBHAS ROAD BANKURA 722101 W B | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹13.6 L+₹50,202.56 (3.83%)Rejected-Finance INDARAGORA BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L3 | Rejected-Finance Rejected | |
| 4 | L4₹13.9 L+₹83,844.45 (6.40%)Rejected-Finance JOGESHPALLY BANKURA 722101 W B | BANKURA | BANKURA | WEST BENGAL | 722101 | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹39,100
Closing Date
18 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, BMD, P.H.E.Dte.
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Restoration flood effected Tube well along with other allied electro-mechanical works for newly sunk Tube Well at Radhaagar water supply scheme, Bishnupur Block under B.M.D. PHE Dte. Dist Bankura
2022_PHED_385954_2
WBPHED/EE/BMD/NIeT- 6 OF 2022-2023
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹39,100
Yes
2 Aug 2022
24 Jun 2022
21 Jul 2022
24 Jun 2022
18 Jul 2022
24 Jun 2022
120 days
Amount
Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034 (and as amended threreafter) with standard MOC for potable clear cold water capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) as per following specification and as per technical specification given in NIT a) Discharge-53 M3/Hour, Head -22 Mtr (Manufacturer test certificate and Warranty certificate along with curve chart should be submitted at the time of delivery)
Supply and delivery of the following materials at site as per direction: -
Safety device for the above pump set by supplying MS cage with proper clamping arrangement and nylon rope as per requirement including supply of all required materials with nuts and bolts as required
MS E.R.W as per IS:1239 100mm. Ф. Heavy type Column pipe with one end socketted and both end threaded.
3 mtr long
1.5 mtr long
Heavy type MS fabricated suspension clamp suitable for above 80 mm Ф column pipe with necessary nuts and bolts.
Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland
Supply and delivery CIDF Non return valve 100 mm dia PN 1.0 as per relevant IS - As per technical specification
Supply and delivery CIDF Non rising type sluice valve 100 mm dia PN 1.0 as per relevant IS As per technical specification
Supply and delivery of three phase actuator and actutator operated 100mm dia flange type butterfly valve (PN-1.0) as per BS-5155 As per technical specification
102mm Ф 0-7 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings
Supply and delivery of 100mm Φ following GI specials
Cross
100 mm x 200 mm long nipple
100 mm dia G.I heavy type flange
Socket
Supply and delivery of 40mm Φ following GI specials for cable protection
100mm long nipple
Union
Pipe ( Medium) including necessary socket.
Supply and delivery at site following M.S. fabricated cubical type wall mounted motor control center with hinge type front door cover made of 2mm thick CRCA sheet and suitable locking arrangement having fully automatic programmable logic control system based on PLC with manual and fully auto bypass mode, suitable for operation of butterfly valve through actuator along with submersible pumping machinery, and capacitor bank according to preset time and technical specification given in NIT N.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel.
Supply, delivery and storage at site of following cables
4 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date.
1.5 sq mm , 12 core , 1.1 KV Grade PVC insulated Copper Armoured control cable Armoured and As Per IS-7098 (Part 1) 2011 with Up To Date Amendments. From MCC panel to two nos actuator
10mm2 3Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments From MCC panel to kiox box
6mm2 2 Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments For Yard lighting
25mm2 3.5 Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments From MCCB to MCC panel N.B- All cables should be purchased as per site condition
Supply and delivery of following lights Fixture
Out dooor 170 watt LED Based flood light luminaries suitable for existing high mast lighting arrangement . Model No-BVP192 LED 160 of Philips make/ or equvalant model
Outdoor street pole light, Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set. M.No-BRP062 LED 84 CW SLC S1 PSU of Philips make/equivalent model.
Laying of cable
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting from main panel to new MCC panel.
Laying of above 6sq mm 2 core cable through the under ground trench having depth 760mmX width 460mm and laying 8 nos brick for per mtr length of the cable for protection of the cable including sand filling ramming complete as per IE rules as per direction of the EIC.
Laying of two nos 10 sqmm and Controll cable in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. i) 100 Amp (Legrand)
Supply and delivery of 450mm(H) x 300(B) x 250mm(H) size out door CRCA sheet steel fabricated cubical type kenopy top cable jointing box inside fitted 6 nos 63 Amp rated bus bar and hinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C
Making 300mm(W) x 300mm(B) x 900 mm (H) size rising main supporting brick pillar at least 300mm depth from ground level to pumping floor level and neat cement finish all complete as per direction.
Installation of Cable jointing box by the making 450mm(W) x 450mm(B) x 1000mm(H) size brick pillar at least 300mm depth from ground level or as per requirement including plastering and net cement finish all complete as per direction.
Making double Earthing arrangement of MCC Panel in complience with I.E rules by G.I pipe electrode with G.I funnel(50mmx 3 mtr long) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 25mmx 6 mm GI strips for continuty to installaled MCC Panel and making suitable size earth pit etc all complete. as per technical specificaion
Making Earthing arangement of out door kiox box in complience with IE rules by the 50 mm dia x 3mtr long G.I pipe(ISI Medium) including drawing between Kiox box to earth pit by the 20mm x 3 mm G.I Strip and making suitable size earth pit etc all complete. as per technical specificaion
Installation of the above pumping machineries and MCC panel of item no (1 to 10.1 and 11) by necessary jointing materials and interconnection of the sub–cable, and specials Light Fixture including making cable finishing, cable gland, and G.I Submersible cable protection pipe from Kiox to T/W cover, bricks foundation of surrounding area of T/W etc and supply of all necessaries materials and painting of anti corrosive paint after using primer of delivery line etc as per direction of E.I.C
Testing commissioning of the whole installation and PLC system and other electrical equipments to ensure performance of the equipment in running satisfactiory as per direction of E. I. C.
Add: 12% GST
Add: 1% Cess
RAJIB COMPANY
M/S NABIN GOPAL SENGUPTA
KASHI NATH DEY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .