Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹22.0 L+₹1.4 L (6.85%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹22.6 L+₹2.1 L (10.2%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹22.9 L+₹2.4 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹23.2 L+₹2.7 L (13.0%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Oct 2021, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
GE/C-37/2021-22 REPAIR/REPLACEMENT OF UNSV PARTS OF LT PANEL INCLUDING SUB MAIN WIRING DB AT RRRC AND ADJOINING AREA AND PETTY REPAIR MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS AT PRATAP CHOWK TAURUS ENCLAVE ADJOINING AREA UNDER GE(CENTRA
2021_MES_475500_1
GE/C-37/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt-10
₹90,000
Yes
29 Oct 2021
15 Sept 2021
13 Oct 2021
15 Sept 2021
6 Oct 2021
30 Sept 2021
15 Sept 2021 - 30 Sept 2021
Amount
Taking down carefully unserviceable LT panel including disconnecting of incoming and outgoing connections complete all as specified and directed.
M&L earthing with galvanized steel earth plate 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 40 mm bore for protection of G.I. strip from earth electrode to the Main switch/Distribution Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 (20 mm graded stone aggregate) reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25x4 mm thick galvanised strip duly fixed on suitable size of porcelain/ PVC insulator complete all as specified and directed.
Taking down carefully unserviceable distribution boards including disconnecting of incoming and outgoing connections complete all as specified and directed.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB SPN 40 to 63 Amp Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified and confirming to IS : 8623 complete all as specified and directed.
Supply and fix Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through new PVC conduit in walls all as specified and as directed. Note: 2 run of 1.5 sqmm 01 run of 1.5 sqmm single core and 1 run of PVC conduit shall be measured as 1 length
Supply and fix Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed. Note: 2 run of 4 sqmm 01 run of 2.5 sqmm single core and 1 run of PVC conduit shall be measured as 1 length
Supply and fix Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through new PVC conduit in walls all as specified and as directed. Note: 2 run of 6 sqmm 01 run of 4 sqmm single core and 1 run of PVC conduit shall be measured as 1 length
Supply and fix Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed. Note: 2 run of 10 sqmm 01 run of 6 sqmm single core and 1 run of PVC conduit shall be measured as 1 length
S&F blank plate of suitable size for open space in distribution boards complete all as specified and directed.
M&L providing protection pipe PVC or flexible pipe as reqd at site to out going cables, cleaning of LT panel boards with air blower cleaning inside, dressing in proper alignment, replacement of rusted iron parts with new one with suitable size of angles/strips tightening of fixing bolts and nuts, providing thimbles to whole bunch of wires uniformly clean manner etc complete all as specified and directed.
Supply and Fix in replacement of 45W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 100 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 63 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 20 A capacity complete all as specified and directed by Engineer in charge.
M & L in replacement for only twin core PVC insulated unarmoured cable 10 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
M & L in replacement for only twin core PVC insulated unarmoured cable 6 Sqmm Flat 1100 Volts with Aluminium multi stranded conductor complete all as specified and directed by Engr-in-Charge.
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Pratap chowk and adjoining area.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 27 to 29 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Pratap Chowk Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this. (h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am). Notes for Item No. 30 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Pratap Chowk Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only switch piano 6 amp SP two way, ISI marked Make:Havells Reo or equivalent in legrand/Schneider.
Supply only socket piano outlet 6 Amp flush button type all as specified
Supply only bell push single pole 6 Amps all as specified
Supply only switch piano flush button type single pole 16 Amps.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete. Make : Anchor/ Havells/ cona
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge.
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge.
Supply only ceiling rose surface PVC type with three terminals.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed. Legrand/Havells Reo/ Anchor
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply only relacement plug top 16 Amps 3 pin 230- volts Make:- Crabtree/Havells Reo.
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting.
Supply only MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) . Make- Legrand /Havells/Crabtree/Polycab.
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code completed all as specified.
Supply only copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge
Taking down sub main wiring off sizes etc complete all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 4.00 sqmm (Main Cable and neutral) and one run of 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 6.00 sqmm (Main Cable and neutral) and one run of 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 10 sqmm (Main Cable and neutral) and one run of 10 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Note :- Total amount of Sch of credit is Rs. 55661.50 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
Pall Associates
M/s Sohanil Construction
AMIT BROTHERS
M/S ANIL KUMAR
S. S. CONSTRUCTION CO.
POONAM ENTERPRISES
Mani Control System
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .