Loading…
Loading…
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
COMPREHENSIVE MAINTENANCE TO REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION AND CONNECTED WORKS IN OTM AND MD ACCN UNDER AGE EM II OF GE (SOUTH) MEERUT
2026_MES_774826_1
95516/S/E8
Open Tender
Civil Works
180 days
Meerut
Please refer tender pages
9 documents required · 9 mandatory
₹500
GE (South) Meerut
₹96,000
25 Jun 2026
25 Jun 2026
18 Jul 2026
25 Jun 2026
16 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring of any type except batten or conduit, (Light, Fan, Socket or power) complete incl fittings, DBs, MCBs and making good the disturbed surfaces of walls, ceiling etc in cm and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as directed by Engineer - in- Charge. | 470 | Per Point | - | - | BI01010001010000000000000515BI0100001112 |
| 2 | Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, Fire Retardant conforming to IS 694-1990 PVC insulated, unsheathed copper conductor cable FRLSH in existing PVC concealed conduit of not less than 20 mm dia or higher, medium grade complete with and including brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for One light point controlled by one, one way switch 05/06 Amps. | 300 | Per Point | - | - | BI01010001010000000000000515BI0100001113 |
| 3 | All as per Item No 2 here-in-before but one bell point controlled by one bell push 05/06 Amps. | 15 | Per Point | - | - | BI01010001010000000000000515BI0100001114 |
| 4 | All as per Item No 2 here-in-before but one ceiling fan point controlled by one, one way switch 05/06 Amps. | 50 | Per Point | - | - | BI01010001010000000000000515BI0100001115 |
| 5 | All as per Item No 2 here-in-before but one exhaust fan point controlled by one, one way switch 05/06 Amps. | 15 | Per Point | - | - | BI01010001010000000000000515BI0100001116 |
| 6 | All as per Item No 2 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. | 40 | Per Point | - | - | BI01010001010000000000000515BI0100001117 |
| 7 | All as per Item No 2 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. | 30 | Per Point | - | - | BI01010001010000000000000515BI0100001118 |
| 8 | All as per item No 2 here -in- before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15/16 Amps socket outlet point on independent board. | 20 | Per Point | - | - | BI01010001010000000000000515BI0100001119 |
| 9 | Taking down carefully copper/aluminium point wiring of any type batten or conduit (Light, Fan, Socket or power) complete incl fittings, DBs,MCBs and making good the disturbed surfaces of walls, ceiling etc in cm and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as directed by Engineer-in-Charge. | 365 | Per Point | - | - | BI01010001010000000000000515BI0100001120 |
| 10 | Material & labour for new point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, Fire Retardant conforming to IS 694-1990 PVC insulated, unsheathed copper conductor cable FRLSH in and including PVC concealed conduit of not less than 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for one light point controlled by one, one way switch 05/06 Amps. | 190 | Per Point | - | - | BI01010001010000000000000515BI0100001121 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_867621.xls
BOQ • 0.30 MB
Tender95516.pdf
Tender Documents • 1.38 MB
Download all tender documents and submit your bid