| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.5 LAccepted-AOC FLAT NO 205 SYNERGY WORLD KOSARA DISTRICT CHANDRAPUR MS 442401 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | ₹26.5 L Quoted ₹22.4 L | L-1 | Accepted-AOC Lowest qualified bidder. Hence being awarded. |
| 2 | L-2₹22.5 L+₹2,701 (0.12%)Rejected-AOC UTTAM NAGAR BENGALI CAMP MULI ROAD CHANDRAPUR 442401 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | ₹22.5 L+₹2,701 (0.12%) | L-2 | Rejected-AOC Not a qualified L1 bidder |
| 3 | L-3₹23.6 L+₹1.1 L (5.03%)Rejected-AOC | ₹23.6 L+₹1.1 L (5.03%) | L-3 | Rejected-AOC Not a qualified L1 bidder |
| 4 | L-4₹23.6 L+₹1.1 L (5.09%)Rejected-AOC | ₹23.6 L+₹1.1 L (5.09%) | L-4 | Rejected-AOC Not a qualified L1 bidder |
| 5 | L-5₹23.9 L+₹1.5 L (6.54%)Rejected-AOC C O REKHABAI NAITAM KILLA WARD BALLARPUR DIST CHANDRAPUR 442701 | BALLARPUR | CHANDRAPUR | MAHARASHTRA | 442701 | ₹23.9 L+₹1.5 L (6.54%) | L-5 | Rejected-AOC Not a qualified L1 bidder |
Tender Value
₹37.3 L
EMD Value
₹46,700
Closing Date
8 Dec 2023, 3:30 pmClosed
Shri. Nitin Naik
OFFICE OF THE AREA GENERAL MANAGER WCL BALLARPUR AREA P.O. SASTI TA. RAJURA DIST. CHANDRAPUR (MS) PIN 442905
Development work at Dhoptala Sub Station at Sasti Sub Area
2023_WCL_294683_1
wcl-ba3650-civ-e135-23-24/745
Open Tender
Civil Works - Buildings
Item Rate
45 days
WCL Ballarpur Area
As per NIT
4 documents required · 4 mandatory
₹46,700
6 Apr 2024
28 Nov 2023
9 Dec 2023
28 Nov 2023
8 Dec 2023
28 Nov 2023
28 Nov 2023 - 5 Dec 2023
Amount
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos Cement sheet
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. ( 40 mm th with C.C. 1:2:4 with 20 mm stone aggregate )
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Brickwork with FLY ASH bricks in foundation and plinth in c.m. 1:6 with approved quality as per the instructions of engg in charge.
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Brick work with fly ash. (non modular) brick of classdesignation 7.5 in superstructure above plinth level up to ( In CM 1:6 ) floor five level in :
Centring and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc.and removal of form for. Columns, Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) kg
Float glass panes 4 mm thick glass pane (weight not less than 10kg/sqm).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with Acrylic Smooth exterior paint of required shade :New work ( Two or more coat applied @ 1.67 ltr/10sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm.)
Painting with synthetic enamel paint of approved brand and manufacturer to give an even shade ( Two or more coats on new work )
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1stclass hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of Tiron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
Applying priming coat: With ready mixed pink or Grey primer of approved brandand manufacture on wood work (hard and soft wood)
Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FRLSH PVC copper wire in HMS PVC conduit min. 20mm dia. as per specification No: WG-MA/PC.( 1.6.4 )
Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board. ( 1.7.13 )
Point wiring for light/fan/bell in 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW
Point wiring for independent plug in 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket, copper wiring and earthing as per specification No: WG-PW/SW
Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting triple pole metal clad HRC fuse switch 415V, 63A with neutral link with HRC fuses on angle iron /GI frame as per specification no. SW-SWR/TPHRC.
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting LED street light fitting 100W, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No FGODF/ FLS-2.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Clearing jungle including uprooting of rank vegetation,grass, brush wood, trees and saplings of girth up to 30 cmmeasured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside theperiphery of the area cleared.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre?coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity<0.043w/mK
Total impact of GST for the purpose of CTC
M.V.K Engineering Services
Nitikesh Damodhar Tagselwar
Kolkata garden nursery
Omprakash Yadav
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .