Loading…
Loading…
Tender Value
₹2.3 Cr
EMD Value
₹2.6 L
Closing Date
17 Apr 2025, 3:00 pmClosed
Execution of Signaling & Telecommunication work in connection with: (1) Provision of road under bridge for closure of manned level crossing No.DD-19 at Km. 889/7-8 in Durg-Dallirajhara section, (2) Provision of road under bridge for closure of manned level crossing No.DD-59 at Km.947/1-2 in Durg-Dallirajhara section (By Cut & Cover Method), (3) Provision of road under bridge for closure of manned level crossing No.DD-08 at Km. 874/2-3 in Durg-Dallirajhara section (By Cut & Cover Method), (4) Construction of RUB at Km. 855/7-9 in lieu of manned level crossing No. 440 between BIA-BPHB section in Howrah-Mumbai main line, (5) Construction of Pathway & improvement of lighting facility at reception yard BMY.
SNT-R-2025-07
SNT-R-2025-07
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹2.6 L
18 Mar 2025
18 Mar 2025
A-Execution of Items
B-Supply of Items
C-Supply & Execution of MSDAC
D-Supply of LED Signal
Item Breakup - A-Execution of Items
Excavation of trench Depth 1.0 Mtr. & width Kilometre 0.3 Mtr and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil in all soils including soft rocky area.
Excavation of trench in all kinds of soils Metre including softrockyarea and clearing of roots of trees, bushes, rocks,ballastetc., to a depth of 1 Mtr. & width 0.3M for track/puccaroad/Platform crossing/ level crossing and any other placeasadvised by the Engineer-incharge includingsupply,transportation and laying of RCC pipe with collars(forjointing pipe) 150mm nominal dia to Spec.No:IS-458intrench and drawing of Signalling/ Power/ Quadcablesthrough pipe including back filling and ramming aftercablelaying as specified in Technical Circular No.2 of1988issued by CSTE/S.E.Rly. This includes repairingandplastering of platform/pucca road after cable laying.RCCpipe shall be inspected by the Rep.of Sr. DSTE /Rbeforelaying. NOTE:- Power cable,signalling cable, Quadcable asmentioned above,where required shall be laid in thesame trench as signalling cable but in a separate pipe.
Laying and Fixing of galvanised iron pipe (GI Metre Pipe) withthreadedcollars (for jointing pipe) of 80 mm nominal diaSpec.No.IS-1239medium grade, on bridges, culverts, drainsincluding supply andtransportation of GI pipes and all othermaterials required forfixing the pipe to Drg.No.Con/SK/T/2and drawing ofSignal/Power/Quad cables inside the pipewith masonary worksover the entire length of the bridge andat entry and exit of theculvert and curing for 72 hrs, drillingof holes on the pipe at 10 cmapart to be clamped 2 Mtrsapart on culvert, for the Signalling,quad, power cable.
Excavation of trench and clearing of roots of Metre trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil in Hard rocky area includingconcreting. Chase cuttingand smoothening of inside surfaceof sizes 0.08 m deep and 0.17m width at platform andcemented floor area. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Excavation of trenches including clearing of Metre roots oftreesetc. in hard rocky soil by chiseling up to a depth of0.5m to0.8 Mtr. At the bottom, supply and placing half roundRCCpipe on sieved soil of 30 mm over cable andconcretingthroughout the lenght upto a layerof 75 mmapproximately(1:2:4) , as advised by the site engineer &Guide lines onSignalling cable Laying issued by SignalDirectorateResearch,Design & Standards organisationMinistry ofRailways Manak Nagar Lucknow- 226011,Version- 1.0,Effective from dt 31.10.2011 . Thendigging and backfillingthe trench by digging and carryingearth from a lead ofmaximum 30Mtrs and then ramming thesoil after cablelaying. This includes supply of half round RCCpipe.
Excavation of trench and clearing of roots of Metre trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil. Track crossing, Road Crossing bypushing method(HDD method) at culverts/ track / puccaroad crossing at a depthnot less than 1 meter with referenceto bottom of rail/road surfaceincluding supply of GI pipe with76 mm dia, Spec. No. - 1239medium grade (for the length ofpushing more than 05 meters).
Fixing of concrete cable route marker at 30- Numbers 40 meter andatdiversion point including supply & transportation ofcableroute marker at site. Detail size & fixing of cableroute marker should be followed as per drawing no.SDO/Cablelaying/020.
Laying of Signalling Cable/Power/Quad cable / Kilometre PIJF cableinthe excavated trench toDrg.No:CON/SK/T/5.Transportation,supply of 'U' clampsand anchoring of cable at every 10 Mtrswith 'U' clamp toDrg.No:CSTE/C/Cable/81 including backfilling withexcavated earth and ramming of trenches aftercablelaying. Note: The contractor has to conduct detailedsitesurvey of the cable route, prepare a plan to get approvalofthe Railway, putting white lime powder markingbeforeexcavation of earth under supervision ofrailways authorised representative. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
The excavation of pit, casting of concrete Numbers foundationincludingsurrounding earthwork along the foundation,erection, installationand wiring of steel appartus case, fixingof terninals, fuse blocks,signal transformer, currenttransformer, filament switching unit,track battery chargers,adjustable/fixed resistances, choke coils,Fuses, Relays, Etype locks , termination of cables, cableinsertion, wiring todraw 110V AC therefore in the new apparatuscase asrequired, testing, commissioning includingsubsequentalterations (if required), bunching of cables,earthing of cable,armours etc. Painting of the apparatuscase inside and outsideafter clearing the surface thoroughlyand first coating of anti -corrosive paint and subsequent twocoatings of Alluminium paintoutside and Red Oxide insideand lettering. 18 mm Hylum sheetfor location box shelf and12 mm for cable termination in locationbox.Steel appartus case (Large) to Drg.No. CON/SK/T/8 with 4Nos. of foundation bolts 20mm x 460mm to Drg.No. SA- 112 A/M or latest.
Alteration/ Modifications in the existing Numbers location boxes, fixingofequipments, cable insertion, termination, wiring, testing&commissioning, two coat painting, lettering to suit thecircuits asper approved wiring diagrams. This includes fillingwith sand and plastering the same.
Execution usingthermoshrink/Universaljointing kit for derivation/terminationjoints with VF Transformerson Quad/jelly filled Telecom Cable.
Installation, testing and commissioning of Numbers Permanent andMaintenance Free Earth pits.Installation charges : Earthpit(1 Set) It includes: (1) Civil works related to earth pitdigging, PMF earth pit installation,,backfilling and chamber making, (2) Materials for chamber including Chamber Cover.
Excavation of earth pit, transportation, Each placing and fixing ofearth electrode with construction of cement encloser toDrg.No.CON/SK/T/9 and CON/SK/T/9A and drawal of GIwire wrapped on MS strip (35 x 6 mm) from earth electrodeto all signalling equipments, including fixing and soldering oflugs at both end of the wire.
Modification of existing Hitachi Make EI of Job Automatic Signaling for closure of LC gate no. 440 at Bhilai Station. Re design of EI systems with related application logic &interface Circuit, FAT, commissioning and As made documentation.
Alteration of existing Q-series/Composite Numbers Relay Racks and cable termination racks. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Execution to be made by the contractor in Sheet Autocad as perfollowing :-1. SECRailwayPractice in conformity with GR,SR& SEM. 2 . As per latest typicalcircuit diagram andguidelinesof SEC railway. Design &Preparation ofCircuits and drawingsDesign,Preparation & checking of documents and Circuit diagram and drawings(a) Design and development of Circuit Diagram in size B(A3) as per SEM sheet including contact analysis.
Alteration/modification, commissioning, two coat painting, lettering of theexisting 2 Aspect/3 Aspect/4 aspect signals/shuntsignals/calling on signal/ LCgate to suit the circuit per approved wiring diagram including fixing of LED/Singallamps and their wiring.
Supply termination of cable, erection of rail post of size2.8mtrs including foundation of post in cement concreate (1:2:4) as per the direction of thesite Engineer incharge of Railway, testing and commissioning of six pin emergency socketbox complete cast iron make as per Drg. No. SE/T/50/76. This include transportation of railposts (provided by the Railway) from Bilaspur or any place in the section to work site,fixing of 40 mm dia G.I.Pipe and emergency socket box. Cast iron emergency socket boxwith complete fittings are to be first supplied to the stores of SSE/T- W/BSP and thencollected from there for execution. Supply of U-bolt for fixing emergency socket, cuttingof Rails to the size and welding of G.I.Pipe on the rail post will be done by the Contractor.This work includes painting of rail posts with black and white paints after two times primer coating.
Design & Preparation of SWR & GWR in Numbers English & Hindi for execution to be made by the contractor as per SECRly practice in conformity with GR, SR & SEM provisions and in accordance with CSTE/OL/GRC's circular No.3 of 1984 with the latest alterations & amendments based on IP (tentative/approved) (to be supplied by the Rlys).
Transportation of released materials from site Per Trip to the stores ofSSE(Sig/Tele)/R or BIA or BYT or DRZ or to GSD. This includesloading, unloading and stacking of materials.
Excavation & casting of pedestal foundation Each for left/right hand boom of lifting barriers.
Excavation & casting of foundation for stop Each post.
Erection and commissioning of Lifting Barrier Set assembly complete including boom support, positive boom locking device, Emergency crankhandle attechment, Timer unit to adjust the time for operating the barrier, Fixing of Hooters/Flashers on either side of gate barriers, 1 (one) controlpanel, weather proof painting, lettering, Neccessary MS weight for balancing the booms, etc. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Installation, testing and commissioning of Set sliding boom LC gates complete which includes casting of concrete foundation including surroundingearthwork along the foundation (Dia-30 cm & depth-100 cm total ten numbers per gate), fixing and welding of channel, fixing of clamps, cutting ofrail post, fixing of lock post with two numbers excavation of Pit casting of concrete foundation for type foundation per gate, laying of cable forroad crossing and fixing of MS plate/channel also as requirement of the site condition.
Cement Concrete of proportion 1:3:6 with cum graded aggregate of size 25mm. and below.
Deployment of Prokline/ Hydra operation at Hour site forexposingthe burried cables or relocation the Location Box/SignalPost with foundation or shifting of heavy materials as per the advice of Railway site engineer.
Physical tracing and opening/locating of Metre existing workingcables by precession digging for diversion of cables inconnection with cable clearance for engineering earth workwithout interfering the circuits as per the advice of Railwaysite engineer.
Installation and Fixing of "E" type lock along Number- with Welding Work . Month
Installation, cable termination, wiring,testing Number- of magneto telephones. Month
Installation and wiring of Rotary key Numbers transmitters/KLCR on teak wood board enclosed inside asuitable box with front transparent check cover with locking arrangement. This includes 3/4" thick teak woodboards, transparent sheet for box, locking arrangement. 2 nos.of locks for box and 1 No. lock for front transparent sheet.
Design, Preparation & checking of documents Station and Circuit diagram and drawings - Development of SIP based on ESP on size W(A1).
Design, Preparation & checking of documents Station and Circuitdiagram and drawings - Design and development ofStation working rule Diagram (SWRD) based on SIP ofstation in size U(A3) as per SEM.
Moorum filling as per site requirement. cum Moorum shall be arranged by the contractor.
Design, Preparation & checking of documents Station and Circuit diagram and drawings - Design & development of cable corage plan in size U(A3) as per SEM.
Design, Preparation & checking of documents Station and Circuit diagram and drawings - Design & development of cable route plan in size U(A3) as per SEM.
Splicing/termination of OFC Pigtail/patch cord Numbers as per instruction of site in charge. Necessary arrangement including Splicing machine required for splicing shall be arranged by Contractor. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Transportation, installation of optical fibre Numbers joint closure and splicing of Optical fibre cable (2 x 24 fibres) and testing, Optical fibre cable splicing shall be done in the presence of Railway's representative. Only joint closure shall issued by the Railway. All other tools/test equipments required shall be arranged by the Contractor. This also includes excavation of earth for construction of masonary pit of bricks (inside complete plastered), the inner size of pit 1.2m x 1.2m (depth 0.75m) in all types of soils for keeping cable coils at the location of OFC joints, filling the pit with sand after jointing of cables, ramming and covering with RCC slab as per Drg. and instructions of site incharge of Railway.
Transportation including loading/unloading of Kilometre HDPE pipe from the stores of railway to the work site, laying of the same in excavated trench/already laid GI/RCC pipes/tubes, jointing, levelling and end sealing the pipes.
Transportation, loading/unloading of OFC from Kilometre the stores of railway to the work site with care, pushing/pulling OFC through the HDPE pipes, sealing of the duct by sealling /caps plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually. This also includes testing of cable drums in the store premises before transportation and submissions of results thereof. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor to the stores depot of Consignee.
Supply, Transportation, fabrication and fixing Sqm of Hylum sheet of 12 mm thickness as per site requirement.
Dismantling of Lifting barrier complete and Numbers stacking as per instruction of Rep.of Sr.DSTE/R.
Dismantling of operation cum indication panel Numbers and stacking as per instruction of Rep.of Sr.DSTE/R.
Dismantling of Signal posts/BSLB/SLB/Stop Numbers Board and stacking as per instruction of Rep.of Sr.DSTE/R.
Dismantling of Steel apparatus case with Numbers fittings and stacking as per instruction of Rep.of Sr.DSTE/R.
Dismantling of Emergency sliding barrier and Set stacking asper instruction of Rep.of Sr.DSTE/R. Note- Unit Numbers stands for Sets.
Dismantling hydraulic breaker).
Dismantling of Signal Foundation(upto ground Numbers level by hydraulic breaker).
Dismantling of Relay racks with all fittings, Numbers battery racks complete, Equipment rack complete, SM's slide and stacking as per instruction of Rep.of Sr.DSTE/R.
Transportation, fixing & commissioning of Numbers different type ofDominos complete with button assemblies and indication tosuit the modification of the existing operation cum indication panel. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Installation of signal posts for Multiple Aspect Numbers Colour LightSignals complete with signal units, bases, LED unit, fixingand wiring of current transformers of LED units, ladders &other fittings, excavation of pit, casting of cement concretefoundations with necessary water outlets, erection andfixing of complete fittings of the signal/signal post withnecessary earthed screen protection arrangement,including drawing of cable through signal posts,termination of cables, wiring, testing and commissioning,two coat painting and lettering, supply and fixing of speedboards if required for the following:- NOTE:- Thefoundation for Multiple Aspect Colour Light Signal Postdrg. No. Con/SK/T/12 and and the foundation bolts shallbe of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M andbolts for each foundation for above shall be of size 20 mmx 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) withtwo nuts and two washers each per bolt. (a) 3 ASPECT/4ASPECT
Dismantaling of unused/old emergency socket Number- post approximate dimention Height -1.25mtr * Month cross section- 15 cm x15 cm (drg enclosed) and transportation from site to GSDstore/Raipur, which includes excavation of soil/concrete to a depth of 15 cm from thesurface and back filling and ramming after cutting the post.This is required to avoidprojection of remain of post over the ground level.The contractor must ensure, that rail postshall be cut below the normal ground surface area.
Transportation and fixing of following types of Numbers C.T.Box and termination of cable as per details of jointing schedule approved by the Railway Engineers. (b) 20 pair C.T.Box (wago type)
Aspect Colour Light Signals complete with Numbers signal units,bases,LED unit, fixing and wiring of current transformers of LED units, ladders & other fittings, excavation of pit, castingof cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of thesignal/signal post with necessary earthed screen protection arrangement, including drawing of cable throughsignal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply andfixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light SignalPost drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/Mand bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. foreach) with two nuts and two washers each per bolt.3 ASPECT/4 ASPECT Note: Payment can be released in a partfor the above said works after completion of- (i) Foundation- 30%, (ii) Erection - 15%,(iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45%, (iv) Commissioning - 10% of the rate. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Transportation & Execution of following kinds Numbers of joints on Quad Cable usingthermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2mx 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling andramming after jointing. (b) straight through joint on Quad cable/10-20-50 pairs PIJF Cable. Total 13499256.00
Item Breakup - B-Supply of Items
Cable PVC insulated single core unsheathed Kilometre with plain annealedcopper conductor as per the colour coding scheme of Railways.Spec. no: IRS-S- 76/89 with latest ammendment. 1x 2.5 Sq mmflexible wire. Inspection by Rep. of SrDSTE/R.
Supply of different type of dominoes Numbers complete with button assemblies and indication to suite for modification of the existing operation cum indication panel as per approved Front Plate Diagram. Inspection by Rep. of SrDSTE/R.
Earth CON/SK/8/3/84. Insp. Rep.of Sr.DSTE/R.
Earthing and bonding system as per RDSO Numbers Spec. No.RDSO/SPN/197/2008 , RDSO Drg. No. SDO/RDSO/E&B/001 dt.19.09.08 and RDSO Drg. No. SDO/RDSO/E&B/002 dt. 19.09.08.Earthing and bonding system for Relay Room , IPS Room ,SPDBox, Operator panel in SM's room, signalling equipments inStation building, Block circuit, SSDAC,etc. (a)Supply of"Permanent and Maintenance Free Earth pits materials".1 SetPMF earth pit consisting of:(i)17 mm diameter and minimum 3 mlong Copper Bonded Steel Rod - 1No(ii)GEM- 25 lb - 3 Bags,(iii)25*6*150 mm Cu Bus Bar- 1 No, (iv)Cu lugs and nut bolt 2nos(v)Supply for Connection between Earthpits and MEBB Itincludes 35 sq mm multistrand pvc insulated single core Cu cable(15 mtr Lump Sum).(vi)Supply for Internal connection from MEBBTo SEBB and to other equipments.(50 mtr Lump Sum).It includes16 sq mm and 10 sq mm pvc insulated single core Cu cable.Inspection by Rep. of SrDSTE/R.
Supply of ARA terminal for Signalling Numbers Installation with PBTmaterials . 6 Way (ARA terminal) Drg No.SA- 23756(Adv)Alt3Specn No. IRS-S-75/2006 (Rev..2) with latest amd. Inspection by:RDSO. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Wago / phoneix terminal blocks (Part no.280- Numbers 3100.00 874). 4 conductordisconnect terminal block.It includes : (i) 4 conductor disconnectterminal block for test and measurement; 0.08 mm.sq.-2.5mm.sq., Center marking with slot test for test plug dia2mm/0.079 In and dia 2.3mm/0.091 in; Carrier rail din 35: frontentry;with knife disconnect large cage clampconnection, grey. (ii)End and intermediate plate, 2.5 Mm/0.394 in wide carrier rail din35, grey (Wago part no. 249- 117)(iii) Screw end stop for carrierrail(iv) steel carrier rail;35 X 7.5 mm, 1 mm /0.039 in thick;unslotted (Part no. 210-229/PW11- 0000).(v) WSB quick markingsystem; horizontal; 1 ... 10 (10x); for width 5-17.5 Mm; 10 strips of10 marker per strip (100) per card; consecutive numbers white(Part no. 209 - 502S). (vi) Adjacent jumper nominal current 24A;Insulated Grey. Inspection by representative of SrDSTE/R.
Steel Drg.No.Con/SK/1/1/86 , withE type lock on both side having ward No.32. Inspection by Rep. of SrDSTE/R.
Supply of Optical fibre joint closure for Numbers straight through joint withmodification for 24 fibre OFC as per Specification. No.RDSO/SPN/TC/68/2014 Rev.1.0 Amdt-1 or latest complete with all accessories (sealing with mechanical clamp facility) make Raychem or similar. Inspection by representative of SrDSTE/R.
Supply of permanently lubricated HDPE pipe Kilometre with outerdia50mm, inner dia - 42mm thickness - 4mm with suitable couplers, plugs, end caps etc. as per technical specification No. G/CDS- 08/01 Dec. 1999. Supply to be made in length of 500 mtrs with + /-10% tolerance. Inspection by representative of SrDSTE/R.
Timer Relay Fail safe type of electronic time Numbers delay device - 24 VoltDC(Anu vidyut make or similar) for Rly. Signalling as perSpec.No.IRS:S-61with latest amendment. 10 Nos with 120 Seconds time delay having AFGKY interlocking code pin to be supplied.Inspection by RDSO.
Universal relay, plug in type, style AC/LED all Numbers aspects AClampproving relay unit with in built current transformertype, slowrelease neutral line relay 4F/4B contacts, frontand back contactsmetal to carbon, shall be suitable forworking in series with the110AC LED signal lamp rated at15W conforming to RDSO specn.no. BRS:941A ,STS/E/RELAYS/AC LIT/LED Signal/09-2002, Amdt-1 with latest. Inspection by RDSO.
Relay, AC Immune, plug-in type, Style Numbers "QNA1K", Neutral line, 24VDC 1000 ohms 6F.6B contacts, front and back contacts metal tocarbon with plug board, retaining clip & connectors conforming toBRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 & RDSO Spec. no.STS/E/Relay/UEA(PI). The interlocking code for this unit shall beCDEKY. Inspection by RDSO. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Relay, Non-AC Immune, plug-in type, Style Numbers "QN1', Neutral line,24V DC 8F.8B contacts, front and back contacts metal to carbonwith plug board, retaining clip & connectors conforming toBRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unitshall be ABCDF. Inspection by RDSO.
Relay, AC Immune, plug-in type, Style Numbers "QNA1', Neutral line, 24VDC 12F.4B contacts, front and back contacts metal to carbon withplug board, retaining clip & connectors conforming to BRS:931A,IRS:S 60, IRS:S 34 & IRS:S 23. The interlocking code for this unitshall be ABDFH . Inspection by RDSO.
Non-deteriorating type low voltage electric Numbers fuse for Railwaysignalling, rated voltage 240 V AC/DC fuse with cylindrical capwithout indication size :14x 51 mm. Spec. no: IRS-S- 78/92 withlatest amendment if any. 04 Amp fuse catridge. Inspection by RDSO.
Non-deteriorating type low voltage electric Numbers fuse - 16 Amp fusecatridge for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no:IRS-S-78/92 with latest amendment if any. Inspection by RDSO.
Fuse Block for fuse cartridge, Spec. no: IRS-S- Numbers 75/2006(rev-2) with latest amendment if any. Inspection by RDSO.
20 pair CT Box. Inspection by Rep. of Railway Numbers Engineer.
Key Lock 'E' type with key Drg.No.SA-3376/M. Numbers Alt-2. Spec.No.IRSS- 30/64 different ward . Inspection by Rep. of SrDSTE/R.
Marker 'P' non-illuminated Drg. SA- 23455 Numbers (Adv.) Spec.No. IRS-S-7. Inspection by Rep. of representative of SrDSTE/R.
Marker 'G' non-illuminated Drg. SA- 23476 Numbers (Adv.) Spec. No. IRS-S-7. Inspection by Rep. of SrDSTE/R.
Supply of Universal thermoshrink jointing kit Numbers for derivation/transformer joint for Jelly filled Six quad cable conforming toRDSO Spec.No :IRS-TC- 77/2006(Rev.1) (With latestamendment). Inspection by representative of SrDSTE/R.
Supply of Thermoshrink jointing kit for Numbers 10/20/50 pair Jelly filled cable conformingto RDSOSpec.No.RDSO/SPN/TC/57/2006 (Rev.0) (With latest amendment).Inspection by representative of SrDSTE/R.
Cable PVC insulated single core unsheathed Kilometre with plain annealedcopperconductor as per the colour coding scheme of Railways.Spec. no: IRS-S-76/89 with latest ammendment. Indoor cable asper IRS-S- 76/89 with latestammendment. 40x0.6 mm dia.Inspection by representative of SrDSTE/R.
Cable PVC insulated single core unsheathed Kilometre with plain annealedcopper conductor as per the colour coding scheme of Railways.Spec. no: IRS-S- 76/89 with latest ammendment. a) 16/0.2 mmdia. Insp. By representative of SrDSTE/R. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Cable PVC insulated single core unsheathed Kilometre with plain annealedcopperconductor as per the colour coding scheme ofRailways.Spec. no: IRS-S-76/89 with latest ammendment. Multi strand ISIcopper cable (10 Sq.mm )Inspection by Rep. of SrDSTE/R.
Electric Key Transmitter (RKT) single Drg. No. Numbers : SA -22601(Adv.)Alt.4 with ward No. 2 to 8, spec. no: IRS-S - 21/2001 with latestamendment. Ward wise quantity to be collected from Consignee. Inspection by RDSO.
Supply of 3 Aspect signal unit in FRP body Numbers without Lenses and transformeras per RDSO spec. No.RDSO/SPN/194/2006 or latest. Inspection by representative of SrDSTE/R.
Supply of 4 Aspect signal unit in FRP body Numbers without Lensesand transformer as per RDSO spec. No.RDSO/SPN/194/2006. Inspection by representative of SrDSTE/R.
Supply of 2 Aspect signal unit in FRP body Numbers without Lenses and transformer as per RDSO spec. No. RDSO/SPN/194/2006 . Inspection by representative of SrDSTE/R.
Tubular post for CLS 5.5 Mtr. Spec.IRS.S- 6/81. Numbers Inspection by representative of SrDSTE/R.
Signal.base 140mm.dia(type tube) Drg.No.S- Numbers 2011/M. Inspection by representative of SrDSTE/R.
Ladder 23156(Adv)Alt- 1.Spec.No.IRSS-10. Inspection by representative of SrDSTE/R.
Off set bracket for colour light 140 mm. Numbers outside dia post Drg. No. SA-23080(Adv) Alt- 1.IRS-S- 10-78. Inspection by representative of SrDSTE/R.
Control Panel for Mid section interlocked LC Numbers Gate/IBS(operation-cum indication console Domino type)/ Siding motor operatedpoint operation pannel /Non Interlocking pannel to RDSO Spec. No. 36/87 size of each domino will be 54+10mm X@10"[email protected]% panel LEDs, all type of dominos and buttons assemblies compleate as spare to be supplied. This includes cable termination MSrack with 3/4" thick wood strips including fabrication thereof as per the requirement of the Rly. terminations of cables, fix of terminalblocks, terminals, painting and lettering as required. Note:- MS angle/flat, teak wood, bolts & nuts, screws, shelves etc. required as above shall be supplied by the contractor. Inspection by Rep. of SrDSTE/R.
Cable PVC insulated single core unsheathed Kilometre with plain annealedcopperconductor as per the colour coding scheme ofRailways.Spec. no: IRS-S-76/89 with latest ammendment. Multi strand ISIcopper cable (16 Sq.mm )Inspection by Rep. of SrDSTE/R.
Electrically operated lifting barrier complete Set as per RDSO SPN no. 208/2012 Ver-2 with latest Amendment, operating voltage110V AC,without hand generator, length of the boom is 9.76 meter / 32 feet . Note:- Spare shall also be supplied as per RDSO specifications (rates for them are included above). Inspection by RDSO. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Flasher & Hooter for LC gates (1 set shall Set comprise for 1 level crossing). Inspection by Rep. of SrDSTE/R.
Supply of Emergency Sliding Boom with all Numbers accessories . Make: Podnur S&T Workshop or similar. Inspection by Rep. of Sr DSTE/R. Note- 1 set shall comprise for 1 level crossing.
Supply of pipe lock signal unit ( Handcuff Numbers lock) (Minimum one key for each lock). Inspection by representative of SrDSTE/R.
Pad Locks of godrej make model Nav-tal - 6 Numbers Levers - Long Shackle (3 keys) or latest. Inspection by representative of SrDSTE/R.
Electronic Magneto telephone desk type to Pair Specn No.IRS-TC-79/2000. Inspection by Rep. of SrDSTE/R.
Telephone Switch Board cable 5 pair, 0.5 mm Metre copper conductor dia. to DOT/TEC Spec. no. GR/WIR - 06/03, March 2002 or latest. Inspection by representative of SrDSTE/R. Total 7255744.00
Item Breakup - C-Supply & Execution of MSDAC
Supply of MSDAC complete system (As per Numbers Annexure-A) with all accessories consisting of complete indoor and outdoor equipment including remote diagnostic and monitoring system asper RDSO Specification no. RDSO/SPN/176/2013 Ver.3 with the latest amendment/revision of required Track Sections as per the SIP of the station (SIP to be collected from the Consignee prior to supply). NOTE: Number denotes Per DP for this item. Inspection by RDSO.
Design, Transportation, Installation,testing Numbers and commissioning of MSDAC complete system (As per Annexure-A) with all accessories consisting of complete indoor and outdoor equipment including remote diagnostic and monitoring system as per RDSO Specification no.RDSO/SPN/176/2013Ver.3with the latest amendment/revision of required Track Sections asper the SIP of the station. Note: Number denotes Per DP for this item. Total 1515357.52
Item Breakup - D-Supply of LED Signal
RED Aspect LED Signal Lamp for main colour Numbers light signal, retrofittable inexisting CLS housing withintegrated CRU and compatible with AC LED ECRas per RDSO Spec. No. RDSO/SPN/199/2010 Revision: 1.0 orlatest.Inspection by RDSO.
Yellow Aspect LED Signal Lamp for main Numbers colour light signal, retrofittable inexisting CLS housing withintegrated CRU and compatible with AC LED ECRas per RDSO Spec. No. RDSO/SPN/199/2010 Revision: 1.0 or latest.Inspection by RDSO. RAIPUR DIVISION-S AND T/SOUTH EAST CENTRAL RLY
Green Aspect LED signal Lamp for main Numbers colour light signal, retrofitable in existing CLS housing with integrated CRU and compatible with AC LED ECR as per RDSO spec. No. RDSO/SPN/199/2010 Revision: 1.0 or latest. Inspection by RDSO. Total 474551.16
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .