Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Bid accepted being lowest tendrer | |
| 2 | L2₹13.7 L+₹37,382 (2.82%)Rejected-AOC GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 3 | L3₹13.8 L+₹54,423 (4.10%)Rejected-AOC | L3 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 4 | L4₹14.7 L+₹1.4 L (10.4%)Rejected-AOC | L4 | Rejected-AOC Other than lowest tendrer hence rejected | |
| 5 | L5₹14.9 L+₹1.7 L (12.5%)Rejected-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-AOC Other than lowest tendrer hence rejected |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
2 Mar 2021, 6:00 pmClosed
CWE MAMUN
HQ CWE MAMUN PATHANKOT
PROVISION OF 160 KVA STANDBY GENERATOR SET FOR RAAVI AUDITORIUM UNDER GE NORTH MAMUN
2021_MES_418910_1
CWE/M-81/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NORTH MAMUN
Class E Category b (I)
5 documents required · 5 mandatory
₹500
Yes
GE NORTH MAMUN
₹30,000
24 Mar 2021
4 Feb 2021
3 Mar 2021
4 Feb 2021
2 Mar 2021
18 Feb 2021
Amount
Supply, installation, testing and commissioning Silent Diesel Engine driven Generating set of 160 KVA rating capacity, voltage not less than 415Volts, 3 phase 4 wire, 50 Hz,1500 RPM, 0.8PF. Engine conforming to IS:10001/10002 (all parts with ammendments till date) and alternator as per IS:13364 (all parts with ammendments till date) complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms etc.. and also confirming for engine ISO8528, ISO 3046, for alternator IS 4722, BS 5000, IS 13364 (Part I & II), for varying load ISO 8528 and for load exceeding 10% ISO 3046 BS 5514. Electronic Governor as per ISO 8528 (Part V), brushless exciter,Solid state voltage regulator, Class "H" insulation, Voltage regulation : No load to full load ,±1% complete with the following specifications :-
(A) ENGINE : Engine conforming to IS:10001/10002 (all parts with ammendments till date) Low emission, high efficiency, direct injection, water cooled engine having 1500 RPM, engine capacity >200 BHP, 147KW and in-line 4 stroke,Optimised turbocharger, exhaust manifold, Stainless steel exhaust flexible coupling, Plate-type lube oil filter, fuel filter, first fill lube oil and coolant, replaceable paper element air cleaner with restriction indicator,Flywheel housing to suit single bearing alternator, Electric starter motor, Coolant heater with thermostatic switch, lube oil heater, monoblock fuel injection pump and fuel feed pump, Water pump, Water temp guage,lube oil gauge, pressure gauge, radiator,coolant inhibitor,Cooling system is designed for max ambient temp 50 Deg. C at rated load.
(B) ALTERNATOR : Alternator as per IS:13364 (all parts with ammendments till date), self-excited, synchronous alternator 415V volts,160 KVA, 0.8 pf, 4 pole, rotating field, Vacuum Pressure Impregnation and epoxy gel coating on the winding, minimum harmonics interference, efficiency of alternator confirming to IS:4722 and IEC 34-1, stamford brushless with AVR control,conforms IP-23 protection, Class ‘H’ insulation, salient pole revolving field, single bearing, Digital automatic voltage regulation ±1% from no load to full load and hot to cold complete
(C) ACCOUSTIC ENCLOSURE : Engine alternator assembly mounted on Anti Vibration Module pad (AVM) with silencer and SS exhaust bellow suitably optimized to meet stringent sound & emission standards as laid down by MOEF / CPCB norms, insulation confirms to UL94-HF1 class for flammability 8 tank process epoxy and polyester powder coated,weather and sound resistant enclosure with UV resistant, can withstand extreme environments , base rail with draw-out type fuel tank is provided with a drain plug, air vent inlet and outlet connections, level indicator, manhole etc, fuel tank for 12 hours (100% load) running capacity, 12/24 Volts dry type,initially charged batterie(s) with insulated Copper connecting leads and terminals, lockable doors on both sides, stainless steel hardware,Heater Kit Operation, Remote Annunciator of suitable capacity shall be provided.
(D) GENSET CONTROLLER WITH AMF PANEL : Microprocessor based, Graphical LCD display,Integrable with AMF panel ,synchronizaon & communication configurations, metering, protection and control system with built-in torque matched Volts/Hz overload control, Single control for all genset function such as Digital governing, Digital voltage control, Engine control,Operator interface, Protection, Advanced control functions, Phase Voltages & Currents, Frequency, Reverse power, Genset kVA , KW, kWh, KVAr, Power Factor, Canopy Temperature , Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level in Ltrs and in percentage , Auto / Manual Stop , Battery charge condition, Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Phase Seq. Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm, Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, low coolant level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency,emergency stop button. Copper Busbar. MCCB,Contactor, 4 pole,415 volts of suitable capacity and all other accessories including wiring with insulated Copper conductor of minimum 4 sq mm size complete accommodated in CRCA sheet enclosure fabricated with locable door duly powder coated all as specified. Note: (i) Testing expenses shall be included in the quoted rate. (ii) Platform for DG set shall be of PCC 1:2:4 type B-1 using 20mm graded stone aggregate,size of platform shall be of (size of DG Set + 200mm extra on all sides) and 400mm in height. (iii) Spares and consumables for 2 year maintenance & servicing shall be provided by the contractor without any extra cost to the deptt. (iv) Rep of OEM shall be present during testing of DG set. (v) DG Set shall be covered under Standard labeling program with all applicable ammendments for 'Scheme for Energy Efficiency Labeling' (vi) DG Set shall be of O2E series (Optimal Operating Efficiency) and Noise level less than 75dBA (vii) Contractor shall submit the CPCB compliance report/certificate of DG Set, BIS certificate for diesel engine, wiring diagram, manufacture test report etc. to the deptt.
Supply,Installing,testing and commissioning factory made and tested, CPRI approved and test certified LT feeder pillar box, outdoor type, floor mounted,3 phase 4 wire, 50 Hz AC supply system,insulated Aluminium busbar, 400 Amps, dust and vermin proof, powder coated in 7 tank process , confirms to IP - 55 class protection, both side openable door, compartamentalised, approns for cable entry with double door shutter and locking arrangement ,made out of 3.15 mm thick CRCA sheet and 40x40x 6 mm angle iron frame with 70 cm leg , Internal wiring with PVC insulated but sheathed, stranded copper conductor FRLS (IS-694) marked,1100 volts grade of adequate but not less than 4.0 sq mm size , printing name of each incomer & out going circuit with 15 mm height letters, PCC foundation of suitable size with comprising the following components including and after dismantling old panel complete all as specified and directed.
B. OUTGOING : (i) MCCB 160 Amp, 4 pole, 25 KA - 03 Nos (01 spare). (ii) MCCB 100 Amps, 4 pole,16 KA - 01 No. (iii) Onload changeover switch,Conforms to IS/IEC 60947-3, 250 Amps,4 pole, 415 volts AC - 01 No (iv) MCB SPN 32 Amps,10 KA - 02 Nos (01 spare) Make of MCCBs : Schneider (NSX)/Legrand (DPX) /SIEMENS (3 VL) Make of MCBs : Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard) Make of Onload changeover switch : Legrand/ABB/Siemens
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 185 sqmm 3.5 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches /pole/ along wall complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 70 sqmm 3.5 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches /pole/ along wall complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.
M & L for sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. [Note : Punned thickness shall be measured and paid]
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth GI strip 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40mm dia GI tubing medium grade protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30cm x 30cm made of RCC 1:1 1/2:3 type A-1 (Nominal mix) reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle, angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10%, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR 2009 compelete all as specified and directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in the unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
BABBAR ENGINEERS
M/s Parv Enterprises
Ashoka Engineers
FANGALIA TRADERS
Sanjay Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .