Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹17.6 L+₹2.3 L (15.3%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L2 | Rejected-Finance BEING OTHER THAN L1 | |
| 3 | L3₹18.1 L+₹2.9 L (18.8%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN L1 | |
| 4 | L4₹19.0 L+₹3.8 L (24.7%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance BEING OTHER THAN L1 | |
| 5 | L5₹20.0 L+₹4.7 L (31.0%)Rejected-Finance VPO SARNA STATION PATHANKOT 145 025 PB | PATHANKOT | PUNJAB | 145025 | L5 | Rejected-Finance BEING OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
10 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
PROVN OF CERTAIN SANCTIONED WORKS OF B/R and E/M AT AIR FORCE STATION PATHANKOT
2021_MES_412576_1
GE/PAF-52/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹38,000
Yes
15 Mar 2021
14 Jan 2021
12 Feb 2021
14 Jan 2021
10 Feb 2021
27 Jan 2021
60 days
Amount
Surface dressing n exc 15 cm deep in soft/loose soil etc complete all as specified and directed by the Engineer-in-charge
Demolition of cement concrete of any description and in any position, provided for complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches n.exc 1.5m deep & n.exc 1.5m wide and n. exc 10 sqm on plan, in soft/loose soil and getting out complete all as specified & directed by Engineer-in-Charge.
PCC Type D-2, 1:4:8 (using 40 mm grade stone aggregate) as in foundation filing of mass conrete as in sub floors complete all as specified and all as directed by Engineer-in-Charge.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and all as directed by Engineer-in-Charge.
Providing RCC Mix M-25 (design mix) (using 20 mm graded stone aggregate ) as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete complete all as specified and all as directed by Engineer-in-Charge. (Note :- Reinforcement shall be measured and paid separately under respective item)
Use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beams; and similar works; in rough finished flat surface of concrete complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of rotational moulded polythene water storage tank (Cylindrical vertical withclosed top) hoisted and fixed in position of 500 ltrs capacity fixed with PVC tank nipples,complete all as specified in SSR Part I complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of ball brass valve, with polythelene float and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia complete all as specified and all as directed by Engineer-in-Charge.
Supplying and fixing of Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:4) including necessary cutting and waste as per site requirement complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing of glazed ceramic coloured tiles size 450mm x 300mm x 7 to 8mm thick on vertical surface such as skirting/dado etc set & jointed in cement slurry and pointed with white or coloured cement to match the colour tiles including 10mm thick rendering on brick/concrete surface in cement mortor 1:3 without using extra cement complete all as specified and directed by Engineer-in-Charge.
Mild steel framed work such as grills, iron gates, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladder; framed balusters, railing, frame work for water tanks and similar work including welding ,cutting etc conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes ( or similar hoels ) each n exc 0.5 cum getting out, returining, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 mtr complete all as specified and directed by Engineer-in-Charge.
Preparation of newly untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate complete all as specified & directed by Engineer-in-Charge.
Removal of excavated material to distance exc.500 mtr But n exc 1000m and deposited where directed at a level not exc.1.5 mtr above the starting point complete all as specified & directed by Engineer-in-Charge.
Steel work as in tabular trusses/supproting pipes etc complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted or welded seams, including bending or turning up, mitred angles, etc.Fe 410 W (Gde E-250) Quality-A complete all as specified and directed by Engineer-in-Charge.
Supply and fix for 0.63mm thick galvanised with grade of zinc coating 275gm/sqm mild steel sheeting (with grade of zinc coating 275 Gm/sqm) with two corrugation side lap fixed with L- type or cranked hook bolts and washer in roof, wall etc bent to curver complete all as specified & directed by Engineer-in-Charge.
Supply and fix for 0.63mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified & directed by Engineer-in-Charge.
Preparing existing new steel surfaces of above bldgs and applying two coats sythetic enamel paint of camouflage pattern with one coat of primer in four or more shades complete all as specified & directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls and ceiling including raking out joints, hacking for keys, scubbing down with water etc complete all as specified & directed by Engineer-in-Charge.
Rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM (1:4) finished even and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
Preparing of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by the Engineer-in-charge
Preparing the newly plastered surface by rubbing, washing down with water and applying two coats of exterior emulsion paint(Asian) with one coat of coloured primer in camouflage pattern (four) or more shades as directed by Engr-in-Charge incl necessary scaffolding and other safety arrangement to work at any height at site if required complete all as specified and directed by the Engineer-in-charge
Taking down chowkhats or frame with shutter exc 1.50 sqm and n.exc 4sqm each (without taking off shutters from the frame), complete all as specified and directed by the Engineer-in-charge
Cutting holes in brick walls built in cement mortar or cement lime mortar exc one brick but not exc two bricks for inserting hold fasts/hinges and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required complete all as specified and directed by the Engineer-in-charge
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410 W (Gde E-250) Quality-A complete all as specified and directed by the Engineer-in-charge
Mild steel bolts dia of neck exc 12 mm or not exc 20mm , purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long complete all as specified and directed by the Engineer-in-charge
Demolation of cement concrete in ground floor and paving unreinforced exceeding 15 cm thickness below and above ground level complete all as specified and directed by the Engineer-in-charge
Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cills lintels upto 1.50m clear span/ benching / coping bed block for hold fast weathering slightly rounded or chamferted angles and throating and necessary from work complete all as specified and directed by the Engineer-in-charge
75mm thick PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in floor finising fineshed even and smooth without using extra cement complete all as specified and directed by the Engineer-in-charge
Glass dividing strips, 38mm thick inserted in position complete all as specified and directed by the Engineer-in-charge
Taking up or down GI tubing 15mm bore including cleaning for refixing complete all as specified and directed by Engr-in-Charge
Refixing old steel tubing and connections of 15mm dia in new or old position (wall, ceiling, floors etc.) complete all as specified and directed by Engr-in-Charge
Brick work with sub class 'B' modular brick straight or curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge
Removal of surplus excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above starting point complete all as specified and directed by Engr-in-Charge
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and directed by Engr-in-Charge
Rendering 12 mm thick on brick work or concrete surface in two layer, in cement mortar 1:4 surface finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
Rendering 12 mm thick on brick work or concrete surface in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
40 mm thick Cement Concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in damp proof course (DPC) to horizontal or vertical surfaces including necessary form work complete all as specified and directed by Engr-in-Charge
Providing 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base , surface finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge
Providing 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection, laid in alternate ways, surface finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge
Non-skid / mat finish coloured joint free ceramic tiles 7 to 8 mm thick( square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:4 complete all as specified and directed by Engineer in Charge.
Glazed ceramic coloured tiles 300x200x 6to7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer in Charge.
Mild steel angles for rafters, pirlins, internal bracings including distance pieces, cleats etc conforming to Fe 410-0 complete all as specified and directed by Engineer in Charge.
Preparing the newly plastered surface by rubbing, washing down with water and applying two coats of cement base paint over a coat of primer in camouflage pattern as directed by Engr-in-Charge incl necessary scaffolding and other safety arrangement to work at any height at site if required complete all as specified and directed by Engineer in Charge.
Factory made Steel window/ Ventilator 1.25mm thick box type(primer coated)ERW hollow P section of size 60mmx25mm including grill using 10 sqmm bar double rebated both gauge and glass shutter comprised gauged glazed Skelton shutter ERW sec 50mmx20mm and 1mm thick with two open able leaf consisting two Nos sash bar of T Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T Section of size 60mmx25mm and 1.25mm thick refer TD Drawing No CEAF/AR-480/2015 Sheet No 2(A)/4 dated 30.12.2015 including taking down with existing one four Nos for each window including following fitting welded to frame shutter : (a) Hold fast,150mm long of 12mmx3mm made to shape O4 Nos per window (b) handle of Z Sec20mmx25mm, 100mm long-per No leaf (c) MS Tower bolt 150mm long-02No per leaf . (d) Z section 20mmx25mm, 100mm long stopper 1 No per leaf. (e) cleat 55mm long of hollow square 15mmx20mmx63mm welded to hinge. 1 No per leaf (f) MS Pintal hinges of size 75mmx12mm. 2 Nos per leaf, (g) Including two coats of synthetic enamel paint complete. (h) Stainless steel wire cloth, 0.25mm to 0.36mm nominal dia of wire & average width of aperture 1.40mm to 2mm &fixed with aluminium wire staples. (j) Glass pane 3mm thick fixed with MS pin and oil putty. NOTE: During Fixing of window, surface Shall be make good in plumb with existing finishes like cement plaster, similar wall tile,floor tile etc and as per site requirement.cutting holes and good dismantled portion in PCC(1:2:4) type B1.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading complete all as specified and directed by Engineer in Charge.
PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in hold fasts including necessary use and waste of form work complete all as specified and directed by Engineer in Charge.
Factory made solid PVC door frame single rebated of size 60mmx30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK 5mm plain colour sheet reinforcement with MS square tube. All as specified . in built fixed to wall with CSK screw 100 mm long, screw holdicrew Complete all as specified and directed by Engineer-In- Charge.NOTE:- During Fixing of chowkhat, surface Shall be make good in plumb with existing finishes like cement plaster ,similar wall tile,floor tile etc and as per site requirement.
Supply and fixing butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed for the 100mm sizes complete all as specified and directed by Engineer in Charge.
Supply and fixing aluminium handles cast type, anodised complete for the 125mm size complete all as specified and directed by Engineer in Charge.
Supply and fixing Aluminium anodised, skeleton tower bolts with plate, staples and bolt of extruded section and fixed for the 450mm sizes complete all as specified and directed by Engineer in Charge.
Supply and fixing 250 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete all as specified and directed by Engineer in Charge.
Cutting chases, pinning in, making good to facings where required and pointing in cm 1:3 for concealed water tubing etc and making good, cutting n. exc. 10 cm width complete all as specified and directed by Engineer in Charge.
Supply and fixing 40 mm bore of pipe un-plasticised PVC of pressure rating 10 kgf/Sq cm fixed complete to wall, ceiling, or in floors complete all as specified and directed by Engineer in Charge.
PVC valve less syphonic action type flushing cistern 10 liters capacity, low level, white with inlet ball valve float and handle including brackets fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Vitreous China EWC Indian (without seat Cover) size 475x350x390 mm white, with integral foot rests (excluding flushing cistern and flush pipe) fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and all as directed by Engineer-in-Charge.
Vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete. Note :- Pillar tape shall be measured as supply only under respective item complete all as specified and all as directed by Engineer-in-Charge.
Viterous China urinal, bowl type back or corner wall type of size 465 mm x355 mm x265 mm complete with waste fittings including providing and fixing complete all as specified and all as directed by Engineer-in-Charge.
Supply only PVC connection 15 mm dia and 450 mm to 600 mm long with brass fly nut at both ends complete all as specified and all as directed by Engineer-in-Charge.
Supply only pillar tap brass chromium plated with capstan heads, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shank and fly nuts complete all as specified and all as directed by Engineer-in-Charge.
Supply and fix 15 mm bore bib taps, chromium plated cast copper alloy, high pressure screwed down, screwed for iron pipe or for brass ferrule complete all as specified and all as directed by Engineer-in-Charge.
Supply and fix PVC (SWR) pipe single socketed in any length with rubber ring, laid in trenches, wall including complete for the 75 mm bore complete all as specified and all as directed by Engineer-in-Charge.
Supply and fix cast iron nahani trap with grating having diameter of outlet 50 mm including joining to waste pipe and fixed in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and all as directed by Engineer-in-Charge.
Supply and fix Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing 32 mm dia bore PVC pipe complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing 15mm dia CP stop cock concealed type cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union, complete all as specified and all as directed by Engineer-in-Charge.
Providing PVC (SWR) pipes 160mm dia single socketed in any length with rubber rings joint laid in trenches or in floors complete all as specified and all as directed by Engineer-in-Charge.
Concrete bed to drain pipes 150mm bore incl. packing under and hunching against the sides of pipe after they are laid and tested in cement concrete 1:36 type C-2 (Using 40mm graqded aggrregate ) complete all as specified and all as directed by Engineer-in-Charge.
Cutting 150mm dia into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and all as directed by Engineer-in-Charge.
Providing RCC Nominal Mix, Type B1, 1:2:4 (using 20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and all as directed by Engineer-in-Charge. (Note :- Reinforcement shall be measured and paid separately under respective item)
Providing RCC Nominal Mix, Type B1, 1:2:4 (using 20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and all as directed by Engineer-in-Charge. (Note :- Reinforcement shall be measured and paid separately under respective item)
Providing RCC Nominal Mix, Type B1, 1:2:4 (using 20 mm graded aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and all as directed by Engineer-in-Charge. (Note :- Reinforcement shall be measured and paid separately under respective item)
Providing RCC Nominal Mix, Type B1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, lintel bands and in columns in floors or roofs, landings, balconies and in shelves and the like complete all as specified and all as directed by Engineer-in-Charge. (Note :- Reinforcement shall be measured and paid separately under respective item)
Use and waste form work to sides of columns, pillars etc. of fair finished surfaces of concrete complete all as specified and all as directed by Engineer-in-Charge.
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work n. exc. 200 mm thick, rough finished surface of concrete complete all as specified and all as directed by Engineer-in-Charge.
Use and waste form work to sides and soffits of floor or roof beams, lintel, cantilevers, chajja, shelves etc. including support of fair finished surfaces of concrete complete all as specified and all as directed by Engineer-in-Charge.
Use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railing , nexc 20cm wide and side of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm and nexc 20cm wide surfaces of concrete complete all as specified and all as directed by Engineer-in-Charge.
Spreading and levelling in layers n exc. 25 cm thick, ramming including watering as required in floors with earth obtained from excavation complete all as specified and all as directed by Engineer-in-Charge.
Mild steel TMT bar 5 mm and over upto and incl 10mm dia as in stirrups, slabs, footing etc cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with complete all as specified and all as directed by Engineer-in-Charge.
Mild steel, plain, black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by Engineer-in-Charge.
Rendering 10mm thick in cm 1:6 finished fair and even on brick wall or on concrete surfacescomplete all as specified & directed by Engineer-in-Charge.
Rendering 5mm thick in cm 1:4 finished fair and even on fair faces of concrete surfaces as in ceilings complete all as specified & directed by Engineer-in-Charge.
PCC 1:4:8 type C-2, 75 mm thick (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified & directed by Engineer-in-Charge.
PCC 1:2:4 type B-1, 40 mm thick (using 20mm graded crushed stone aggregate) as in floor complete all as specified & directed by Engineer-in-Charge.
Rendering of 10mm thick plaster in cm 1:4 finished fair and even on RCC roof slab incl mixing of IWPC complete all as specified & directed by Engineer-in-Charge.( Note :- IWPC shall be measured and paid for separately)
Supply only Integrated water proofing compound complete all as specified & directed by Engineer-in-Charge.
Preparation of concrete/Plastered surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying following roof treatment complete all as directed by Engr-in-Charge :- (a) Applying 1st course of bitumen primer conforming to IS-3384 @ 0.4 Kg/Sqm cover prepared surface till the surface is properly impregnated and insolvent oil primer shall be allowed to evaporate completely. (b) Applying 2nd course of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 1800 C and applied @ 1.2 Kg per sqm. (c) Applying 3rd coarse of APP (Atactic polypropylene) modified polymeric membrane 4mm thick weight not less than 4.5 Kg/Per sqm with 160gm per sqm non woven polyester made at centre core reinforced laid with 75mm side overlap and 100mm overlap. The membrane has to be laid with LPG torch and overlap sealed and fineshed neat. All joint and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @ of 200ml/Bag of cement and curved before laying membrane. (d) Applying 4th course of a coat of bounding material with blown type bitumen of grade 85/25 heating to a working temperature 1800 C and applied @ 1.2Kg per Sqm. Note - Ponding shall be done over RCC slab by filling water which shall be kept there or 48 hours. In case a slightest indication of seepage/leakage is noticed, the same shall be rectifed by grounitng the affected portion at no extra cost. Thereafter ponding test shall be repeated till there is no indication of seepage/leakage before application of roof treatment. A proper record of ponding test of RCC slabs shall be maintained by Engr-in-Charge. The arrangement for ponding test shall be made by contractor. The arrangement for ponding to be included in the quoted rates. nothing extra shall be admissible on this account.
Preparing of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by the Engineer-in-charge
Excavating over areas, n exc 1.5m deep and getting outin average soil complete all as specified and all as directed by Engineer-in-Charge.
Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and all as directed by Engineer-in-Charge.
PCC 1:4:8 type D-2, 150 mm thick (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified & directed by Engineer-in-Charge.
Cement concrete 100mm thick, type B-1, 1:2:4 (20 mm graded crushed stone aggregate) work as in hardstanding laid in alternate bays finishing the concrete surface by brooming complete all as specified & directed by Engineer-in-Charge.
PCC 1:4:8 (nominal mix), type B-2 using 40mm graded crushed stone aggregate as in foundations, filling mass concrete, complete all as specified & directed by Engineer-in-Charge.
Mild steel work in angle iron posts with swan neck and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, inclduing all necessary drilling, bolting riveting etc similar work conforming to FE-290 grade E-165 complete all as specified & directed by Engineer-in-Charge.
Supply only galvanised mild steel wire chain link fencing of 50X50 mm mesh size aparture) including line wire standards rails straining bolts etc including provision of binding wire complete all as specified & directed by Engineer-in-Charge.
Fixing only chain link fencing and line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified & directed by Engineer-in-Charge.
Preparation of new plastered surface of walls and applying two coats of cement base paint of any colour on walls surface over a coat of chalk whitening complete all as specified & directed by Engineer-in-Charge.
Construction of steel gate with RCC pillar (Size 5.5m wide x 3m high) including angle iron frame, guide rail, steel painting, plastering to pillars, excavation and earthwork and shown on drawing (Drg No CEAFU/TD-56/3 sheet No 1/3 to 3/3) complete all as specified & directed by Engineer-in-Charge.
Supplying and fixing of galvanised 2 starred steel barbed wire 2.24 mm dia barbed wire 2 mm dia barb at 75 mm spacing and straining and fixing to any type of sandard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire stapler a steel pin etec as directed (each line wire to be measured) complete all as specified & directed by Engineer-in-Charge.
Supplying and fixing of 5 to 10mm dia mild steel screw bolt (machine made) with hexagonal or square head at one end and screwed the other end or both ends, and screwed end to be fitted with washer and one hexagonal or square nut n exc 5 cm long complete all as specified & directed by Engineer-in-Charge.
MS round bars 10mm dia as in supporting bars of chain link fencing, cut to length bent to shape required including bending and binding with and including MS wire not less than 0.9mm dia or securing with clips quality complete all as specified & directed by Engineer-in-Charge.
Removing excavated material exceed 250 m but not exceed 500 m depositing where directed at a level not exceed 1.5 m of the starting point complete all as specified & directed by Engineer-in-Charge.
PVC insulated flexible three core 1.5 sqmm copper conductor cable complete all as specified and all as directed by Engineer-in-Charge.
Submain wiring alongwith earth wire with the 2x1.5 sq. mm as main lead and 1x1.5 sq.mm as earth wire of FRLS PVC insulated copper conductor, single core cable recessed in and including non metallic rigid PVC conduit ISI marked complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing in replacement switch piano single pole one way 5/6 amps, flush type 230 volts complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing in replacement Ceiling rose, 3 point/ PVC/polycarbonate, 5 Amps, 230 volts, isolated body complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing in replacement distribution board iron clad, SPN 2 way 230 Volts 3 phase 50 hz complete all as specified and all as directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SPN 6 to 32 Amps, 230 Volts, 10kA complete all as specified and all as directed by Engineer-in-Charge.
Flood light fitting LED type 30 Watt with pressure die casted aluminium housing with flat glass optical cover with lens to ensure uniform distribution, IP 65 protection including LED Driver and housing of same make as of fitting as per BIS standards including connecting terminals, mounting clamp, mounting bracket if required and all other accessories reqd for fixing and making fitting operational complete all as specified and as directed by Engineer-in-Charge.
Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core cable multistrand flexible cable and 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core cable(green colour) as earth lead in and including surface/concealed as required in non rigid PVC conduit medium grade with all fittings(ISI marked) controlled by one switch including CI / MS sunk box of required size including plastic lamitated sheet as required and other accessories as required including cutting chases to wall and making good the distributed surfaces to match with the existing specification complete all as specified and all as directed by Engineer-in-Charge.
All as per item No. 115 above but for One 3/5 pin socket outlet 5 amps on independent board, with cables 1.5 sqmm FRLS PVC complete all as specified and directed by Engr-In-Charge.
All as per item No. 115 above but for One 3/5 pin socket outlet 5 amps on same board with other switches, with cables 1.5 sqmm FRLS PVC complete all as specified and directed by Engr-In-Charge.
All as per item No. 115 above but for One 5 pin socket outlet 15 amps on independent board, with cables 2.5 sqmm FRLS flexible unsheathed copper conductor wire complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement socket outlet 5 pin 5/6 Amps, 230 volts, flush type complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement socket outlet multipurpose 15 Amps, 230 volts, flush type complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement switch piano type, one way 15 Amps, 230 volts, flush type complete all as specified and directed by Engr-In-Charge.
Supply and fixing in replacement Distribution board iron clad, double door SPN 4 way 230 Volts flush in wall including cutting chasses in wall and making good to the disturbed surfaces matching with existing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCB SP 6 to 32 Amps, 230 Volts, 10kA complete all as specified and directed by Engr-In-Charge
Supply and fixing exhaust fan 300mm sweep single phase 230 volts 50 Hz AC supply totally enclosed motor in metallic body with die cast alumn rotor complete with louvers including cutting chases for fixing fan, connecting electrically using suitable size PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed by Engr in Charge
Supply and fixing weather proof Bulk Head LED light fittings not less than 7 Watt, 230 Volts,made up of polycarbonate connector block, LED driver etc complete with all accessories, pre-wired complete all as specified and directed by Engr-In-Charge.
Supply and fixing LED Tube light fitting 18 Watt, 230 Volts,box type with LED tube rod including LED Driver, connector block etc complete with all accessories, pre-wired complete all as specified and directed by Engr-In-Charge.
Sub Class 'B' bricks laid dry flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engr-In-Charge.
Sand cushioning to underground cables providing a layer of 8cm thick before laying the cable and 15cm thick after laying,stretching and testing the cable complete all as specified and directed by Engr-In-Charge.
Supply and laying MS Tubes of 40mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in trenches for cable protection complete all as specified and directed by Engr-In-Charge.
Supply, laying and testing cable XLPE Insulated ,armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including connections at both ends with suitable thimbles complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick as earth electrode not less than 2.25mtr below ground level with top edge of earth plate not less than 1.50 metre below normal ground level connected to galvanised earth wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth strip protection pipe GI light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia medium grade with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 with adequate quantity of charcoal dust and salt all around the earth plate including all necessary earth work in any type of soil, removing surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 and directed by Engineer-in-charge. Note:-(i) Main earthing lead from earth plate electrode to test point upto length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .(ii) On testing after completion if the desired resistenance ( up to 5 Ohm) is not obtained the contrator shall redo the earthing without any extra cost to the department .
Vijay Kumar Contractor and Engineers
M/S SINGHAL ENGINEERS
M/S SINGH AND ASSOCIATES
SUBASH MAHAJAN
M/S G P MARWAHA
pardeep singh marwaha
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .