Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC OLD MISSAMARI PO PS MISSAMARI DISTT SONITPUR ASSAM PIN 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹45.3 L+₹64,609 (1.45%)Rejected-Finance RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹46.9 L+₹2.2 L (4.92%)Rejected-Finance HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR TO EXTERNAL WATER AND ELECTRIC SUPPLY SYSTEM AT HATTIGOR MIL STN UNDER GE RANGIA
2024_MES_638416_1
8749/E8
Open Tender
Civil Works
Item Rate
150 days
Hattigor
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹90,000
Yes
4 Mar 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
10 Feb 2024
29 Jan 2024
20 Jan 2024 - 24 Jan 2024
Amount
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm, including dipositing the surplus soil along the line of pipe/ cable in the form of heap, complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for laying 25mm dia (Outer) 3- layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply with all PP-R plain & brass threaded fittings laid in trenches/ fixed to wall including taking down the existing old unserviceable CI/GI/PP-R pipe and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 63mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 90mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 04 here-in-above, but for 110mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
Labour only for laying/fixing of serviceable GI/PP-R pipe of any type of 20mm dia for hot & cold water supply with all fittings laid in trenches/ fixed to wall including taking down the existing CI/GI/PP-R pipe, cleaning the same for re-use and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 25mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 32mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 40mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 50mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 80mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 11 here-in-above, but for 100mm dia pipe, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 25mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 32mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 40mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 50mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 63mm dia (Outer) PP-R Gate valves (brass insert), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of PP-R male threaded coupling with and including necessary jointing material for 90mm dia (outer dia) pipe line, complete all as specified and as directed by Engineer-in-charge.
S&F in repair fully automatic star delta starter 20 HP in sheet metal encloser type MN with single phase protection feature, AC 3 Phase 415 Volt 50 Hz, complete all as specified and diredted by Engineer-in-charge. Make Havells/Standard/L&T/Indoasian
Dismantling and lowering down 5 mm thick pressed steel side plates of size 1.22m x 1.22m from pressed steel water tank on 40 feet staging, carefully without damage to other members after necessary unscrewing of bolts, nuts, washers etc including separating serviceable side plates and kept in safe custody for reuse in the same work complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down 6 mm thick pressed steel side plates of size 1.22m x 1.22m from pressed steel water tank on 40 feet staging, carefully without damage to other members after necessary unscrewing of bolts, nuts, washers etc including separating serviceable side plates and kept in safe custody for reuse in the same work complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of new pressed steel side plate of 1.22mx1.22m and 5 mm thick, made to required shape and drilling necessary holes for fixing of bolts and nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of new pressed steel side plate of 1.22mx1.22m and 6 mm thick, made to required shape and drilling necessary holes for fixing of bolts and nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable pressed steel side plate of size 1.22mx1.22m obtained from serial item No. 25 here-in-before of 5 mm thickness with nuts, bolts and washers in existing pressed steel water tank after proper cleaning with the help of wire brush on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only old serviceable pressed steel side plate of size 1.22mx1.22m obtained from serial item No. 26 here-in-before of 6 mm thickness with nuts, bolts and washers in existing pressed steel water tank after proper cleaning with the help of wire brush on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down of old rusted top plate/roof sheet made out of 3.15mm thick mild sheet from pressed steel water tank on 40 feet staging carefully without making any damage to other members after necessary unscrewing bolts, nuts, etc. complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing of mild steel top plate/roof sheet 3.15mm thick made to required shape and drilling necessary holes for fixing of bolts & nuts and fixed on existing pressed steel water tank on 40 feet staging including necessary wire mesh jaly as required complete all as specified and as directed by Engineer-in-charge.
Refixing of serviceable top plate obtained from serial item No. 31 after properly cleaning with the help of wire brush complete all as specified and as directed by Engineer-in-charge.
Dismantling and lowering down mild steel tie bar made out of angle iron size 65mm x 65mm x 6mm and 2.00 metre long each from pressed steel water tank on 40 feet staging without any damage to other members with necessary unscrewing of bolts, nuts and washers complete all as specified and as directed by Engineer-in-charge.
Supply, errection, hoisting and fixing mild steel tie bars made out of angle iron of size 65mmx65mmx6mm and 3.00 metre long Each and drilling necessary holes for fixing of bolts & nuts in existing pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
Fixing only serviceable tie bars obtained from serial item No 34 above duly cleaned complete all as specified and as directed by Engineer-in-charge.
Supply and fixing mild steel machine made nut and bolt 16-20 mm dia and not exceeding 5 cm long nuts and bolts with washers for fixing of steel plates, tie bars, etc. complete all as specified and as directed by Engineer-in-charge.
Supply and fixing mild steel machine made nut and bolt 11-15 mm dia and not exceeding 5 cm long nuts and bolts with washers for fixing of steel plates, tie bars, etc. complete all as specified and as directed by Engineer-in-charge.
Fixing only serviceable nuts, bolts and washers obtained from dismantled items for fixing of pressed steel plates, tie bar, roof sheets, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for fixing leak proof materials comprising of lead wire, glass wool and black putty in existing pressed steel tanks to ensure water tightness after taking out old existing jointing materials by burning with blow lamps and cleaning and jointing surface complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of painted old steel surfaces (inside surfaces of water tank) by removing all foreign particals from steel surfaces and cleaning throughly the surfaces and complete drying the surfaces and applying one coat of black bituminous paint suitable for drinking purpose in pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new steel surfaces (inside surfaces of water tank) by removing all foreign particals from steel surfaces and cleaning throughly the surfaces and complete drying the surfaces and applying two coats of black bituminous paint over a coat of primer suitable for drinking purpose in pressed steel water tank on 40 feet staging complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted steel surfaces of water tank (outside surfaces or replaced pressed steel sheets and tie bars and angle irons) and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of water tank (out side surfaces of replaced pressed steel sheets and tie bars and angle irons) and priming with red oxide primer and applying two coats of synthetic enamel paint of existing colour complete all as specified and as directed by Engineer-in-charge.
M & L for writing the letters "PS TANK CAP 45000 Ltrs" and " SAVE WATER" on the tank having 40 feet staging with white synthetic paint on front side and "MES" on other side. Size of letter shall be 25-30 cm complete all as specified and directed.
M&L for Overhauling of centrifugal/monoblock pump set of capacity 15HP to 30 HP after removing from base plate disconnecting from pipe line and dismantling pump set, replacing US gland packing, gun metal bush, bearing and water seal and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including dismantling the motor, cleaning the rotor, starter, varnishing, backing etc and reassembling the motor and painting motor and pump sets including suction and discharge pipe line with one coat of paint with spray painting also connecting the existing cable etc. including testing the pump set for full satisfaction of in-charge complete all as specified and directed .Note: 1. Defective major components/spares if required to be replaced shall be measured as supply only under respective item here-in-after and labour element included in item No 46 for replacement of major spares/components.
Supply only Ball bearings any type suitable for pump set of capacity 15HP to 30 HP
Supply only CI Impeller any type suitable for pump set of capacity 15HP to 30 HP
Supply only Shaft stainless steel along with key and check nut of any type suitable for pump set of capacity 15HP to 30 HP
Supply only Oval flange bearing unit of any type suitable for pump set of capacity 15HP to 30 HP
Supply only Rubber coupling of any type suitable for pump set of capacity 15HP to 30 HP
Disconnecting, removing, dismantling including transporting to authorized workshop to carry out repair work and rewinding of electric motor induction type three phase 415 Volts 50 Hz AC supply with supper enameled copper wire of suitable gauge including varnishing, reassembling/ re-fixing, connecting, commissioning and testing and refix at same position complete of 15HP to 30 HP capacity pump motor all as specified and directed by engr -in-charge.
Supply only Ball bearing suitable for 15 to 30 HP induction motor of any type
Supply only Fan blade suitable for 15 to 30 HP induction motor
Supply & Fixing, jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore (Internal Dia) confirming to IS 14846-2000, flanged ends drilled having brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 55 here-in-above, but for 100mm dia cast iron sluice Valve ISI mark (PN-1.6), complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 80 mm bore (Internal Dia), gun metal vertical check valves with iron wheel head, screwed both ends for iron/ PP-R pipe, ISI Marked, as per IS: 778, complete all as specified and as directed by Engineer-in-charge.
M&L for construction of Brick Masonry Valve Pit, of size 900mm X 900mm X 900mm (Internal dimension), one Brick thick wall in cement mortar 1:4 on 150mm thick PCC 1:4:8, type D-2 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally upto full depth and externally upto 150mm below GL, providing 3mm thick MS black Sheet Valve Pit Cover, welded with 40X5mm Flat Iron Frame alround including provision of Hinges, Handle and Locking Arrangement and 40 x 40 x 6mm Angle Iron Frame fixed on Top of Valve Pit by means of Holdfast 150mm long, embedded in PCC 1:2:4 (20mm graded aggregate) Block of size 230 x 200 x 100 mm, applying two coats of Synthetic enamel Paint over a coat of Red Oxide Zinc Chrome Primer after preparation of all exposed to Steel Surfaces including necessary Earth Work in Soft/Loose Soil and demolition of old unserviceable Valve Pit, complete all as directed by Engineer-in-charge.
Supply & Erecting in true vertical in-repair of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat of Red oxide Primer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s), complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately.
M&L for mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
Labour only for fixing in original position of disturbed/dis-aligned mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
M&L for Aluminium conductor steel reinforced (ACSR) (size and type as required at site) drawn for overhead lines with permissible sags and providing jumper with and including copper binding wire or aluminium tapes, including stringing, tightening, etc., including dismantling the existing old unserviceable ACSR, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
Labour only for releasing Aluminium conductor steel reinforced (ACSR) (any size and type) of existing OH lines by un-binding from insulator of any description, re-fixing after stretching, re-stringing the conductor, removing excess sag, maintaining proper distance between conductors as ordered and binding with insulator with aluminium binding wire, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
M&L for Galvanised steel wire 3.15 or 4mm dia as in earth continuty wire, Cradles, hexagonal/rectangular, fixed to pole with aluminium binding wire, including dismantling the existing old unserviceable earth-wire, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
Labour only for fixing in original position of disturbed/dis-aligned Galvanised steel wire 3.15 or 4mm dia as in earth continuty wire, Cradles, hexagonal/rectangular, fixed to pole with aluminium binding wire, including dismantling the existing old unserviceable earth-wire, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
S&F in-repair of Stay assembly of 16mm dia 1.18m long stay rod complete with all accessories as shown in electrical plate No. 1, size of plate 230x230x6mm, complete all as specified and directed by Engineer-in-charge. Note:- Cost of 01 no 65 x 90mm porcelain, vitreous, white, brown or green Loop type insulator, Galvanised stay strand of 7/3.15mm size upto 7.50m long stay strands with clamps and bolts, excavation and concrete shall deemed to be included in unit quoted rate.
S&F in-repair of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of Shackle Type, porcelain, vitreous, white, brown or green insulator including one 31x3mm galvanised mild steel straps, washers, 12mm dia insulator bolts, washers and nuts, 75mm height, 90mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
Fixing only in-repair of porcelain insulator of any type, any size and of any description, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of 10mm dia rigid PVC line separator/ spacer suitable for 2/3/4 LT line of wires, complete all as specified and directed by Engineer-in-charge.
M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed by engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 10 Sqmm 2.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down the existing old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 72 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 72 here-in-above, but for cross-sectional area 50 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 72 here-in-above, but for cross-sectional area 185 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 78 here-in-above, but for 80mm bore (dia) GI Pipe, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 1.2m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 25x4mm) for fixing of building security/ street light fitting as per existing, complete all as specified and as directed by Engineer-in- Charge.
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 Flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 120 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore(light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr earth lead GI earth wire.
All as per Item No. 82 here-in-above, but using 25x4mm galvanised steel strip as earthing lead protected by 32mm dia (light grade) GI pipe, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCCB 4 Pole, 415 Volts, 250 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 36 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 84 here-in-above, but for 160 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 84 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 84 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of digital VAF meter, three phase, including all necessary connections, complete all as specified and as directed by Engineer-in-charge.
M&L for cutting and trimming of tree branches, around OH electric lines and cleaning upto 3.00 m from the OH electric lines including cleaning and removal of trimmed tree branches from site as ordered, complete all as specified and directed by Engineer-in-charge. Note:- Dismentalled ACSR/ Earth wire, etc. during trimming shall be re-fixed at its original position at contractors own cost.
M/s SHARMA BUILDERS & ENGINEERS
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .