P S Shetty
Head TSD BARC
Operation and Maintenance of low side HVAC services and mechanical utility services of DAE convention centre in Anushaktinagar, Mumbai- 400094
2023_BARC_752791_1
BARC/TSD/7/2023-24
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
730 days
DAE CC
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹1.4 L
Yes
DAE CC
6 Jul 2023
12 May 2023
31 May 2023
12 May 2023
29 May 2023
12 May 2023
12 May 2023 - 22 May 2023
19 May 2023
Amount
Operation of Equipment: Operation of Air Conditioning System, chilled water booster Pumps, kitchen ventilation system, fire pumps, solar water heating system, and other mechanical system for 24 months as Technical specification.
Quarterly maintenance & (breakdown maintenance if any) of AHUs (3 nos) of flow capacity from 30000 to 35000 CFM, 60 to 70 TR as per Technical Specification .
Quarterly maintenance & (breakdown maintenance if any) of AHUs (3 nos) of flow capacity from 23000 to 25000 CFM, 55 TR to 59 TR as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of AHUs (5 nos) of flow capacity from 15000 to 16000 CFM, 35 to 38 TR cooling as per Technical Specification.
Quarterly maintenance & (breakdown maintenance if any) of AHUs (3 nos) of flow capacity from 9000 CFM to 9800 CFM, 20 TR to 24 TR cooling as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of AHUs (2 nos) of flow capacity 1500 CFM to 1800 CFM, 05 TR to 6 TR cooling as per Technical Specification.
Quarterly maintenance & (breakdown maintenance if any) of Split AC indoor and condensing units (20 Nos) of 1.5 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of Split AC indoor and condensing units (11 Nos) of 2 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of Ductable split AC indoor and condensing units (16 nos) of 3 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of Ductable split AC indoor and condensing units (44 nos) of 2 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of Ductable split AC indoor and condensing units (5 nos) of 8 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of Tower type split AC indoor and condensing units (21 nos) of 3 TR cooling capacity as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of water cooler units as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of 4800 LPM to 5000 LPM and 22m to 25 m head pump of Kirloskar make as per Technical Specification
Quarterly maintenance & (breakdown maintenance if any) of toilet exhaust fans of following flow capacity 150 CFM to 700 CFM
Quarterly maintenance & (breakdown maintenance if any) of Convention Centre Toilet Exhaust Fans of following flow capacity as per Technical Specification 2 nos fans of from 3600 CFM 3800 CFM .
Quarterly maintenance & (breakdown maintenance if any) of Kitchen Exhaust Fans of following flow capacity as per Technical Specification i) 5 nos fans of 3000 CFM to 3200 CFM
Quarterly maintenance & (breakdown maintenance if any) of Kitchen Fresh Air Fans of following flow capacity as per Technical Specification i) 5 nos of 3000 CFM to 3500 CFM
Quarterly maintenance & (breakdown maintenance if any) of Auditorium –A & B Toilet Exhaust Fans of following flow capacity as per Technical Specification 10 nos fans of 1000 to 1500 CFM
Quarterly maintenance & (breakdown maintenance if any) of Deep Fridgers ( Bottle coolers / Combine coolers),
Servicing /maintenance of Kitchen hood
SITC of Water Pressure Gauges with Syphon Range 0-10 Kg/cm2 as per technical specification
SITC of Water Temperature Gauges with thermowell Range 0-50 deg C. as per technical specification
SITC of G.I ducting made out of 24 G G.I sheet as per Technical Specification
SITC of G.I ducting made out of 22 G G.I sheet as per Technical Specification
SITC of closed cell nitrile rubber insulation of 25 mm thick one side having aluminium foil. As per tender specification
Aluminium cladding over insulation of 28 G aluminium sheet
Painting of pipe line , supports etc. with synthetic enamel paint
SITC of M.S support structure
SITC of Gas charging of split AC 1.5 TR & 2 TR
SITC of compressor of split AC
SITC of remote of AC
SITC of PCB unit of split AC
Fan blade of outdoor unit of window /split AC /cold storage unit as per tender specifications. Capacity up-to 3TR, Make & Model -Existing site.
Weekly testing/checking of fire fighting booster pumps & testing of Alarm Valve as per Technical specification (2 nos of motor driven centrifugal horizontal split case/ end suction booster pump set for 450 LPM to 500 LPMdischarge, Head of 35 m. to 40 m
SITC of Heavy Duty, "C" Class GI pipes of 150 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 100 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 80 mm dia sizes confirming to IS-1239
SITC of Heavy Duty, "C" Class GI pipes of 65 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 50 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 40 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 32 mm dia sizes confirming to IS-1239.
SITC of Heavy Duty, "C" Class GI pipes of 25 mm dia sizes confirming to IS-1239.
Quarterly maintenance & breakdown if any of 2 sets of solar flat plate collectors (2000 X 1000X 100mm) - 08 Nos. each (Total 16 nos flat plate collectors) as per Technical Specification
Quarterly maintenance breakdown if any of 9 sets of solar flat plate collectors (2000 X 1000X 100mm) - 04 Nos. each (Total 36 nos flat plate collectors) as per Technical Specification
Quarterly maintenance breakdown if any of 2 sets of solar flat plate collectors (2000 X 1000X 100mm) - 02 Nos. each (Total 4 nos flat plate collectors) as per Technical Specification
Half Yearly maintenance of department E scooter as per Technical Specification .
E scooter wheel with tyre replacemt
Replacement with Shock Observer set
Replacement of Battery of 2 wheeler E scooter
SITC of AHU belts
Rewinding of motors up to 7.5 KW
SITC of 2 nos of multistage heavy duty submersible (Borewell) centrifugal pump set for 48 LPM Discharge, Head of 135 metre,
Quarterly maintenance breakdown if any of control panel of borewell pump
SITC of water level sensor and converting manual operation of borewell pump into Auto operation along as per specification.
SITC of AHU pulley/Motor pulley
S.I.T.C of 1.5 TR capacity split type air conditioners As per specification.
S.I.T.C of 1.5 TR capacity window type air-conditioners. As per specification
SPEEDFROST SERVICES PVT LTD
M/s Associated Engineers
BRITE INDUSTRIES
Bluestar Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .