Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.6 L+₹1.6 L (4.02%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹41.6 L+₹1.6 L (4.04%)Rejected-Finance | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹41.9 L+₹1.9 L (4.69%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹43.1 L+₹3.1 L (7.85%)Rejected-Finance | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹39.3 L
EMD Value
₹78,600
Closing Date
23 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR TO VARIOUS E/M AND CIVIL WORKS AT DIFFERENT E/M INSTALLATIONS AT OLD IMH COMPLEX UNDER GE ALIPORE KOLKATA
2023_MES_578709_1
GE/ALP (8163B) OF KOLKATA 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class D and category b (i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹78,600
Yes
GE ALIPORE
18 Mar 2023
2 Feb 2023
24 Feb 2023
2 Feb 2023
23 Feb 2023
16 Feb 2023
2 Feb 2023 - 9 Feb 2023
10 Feb 2023
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable , fixing of pole etc and getting out in soft/loose soil complete all as specified and as directed by the Engr-in-Charge.
M&L for dry sand cushioning for protection of under ground cables (8cm before laying the cable and 15cm after laying the cable in trenches) complete all as specified and directed.
S&F Unplasticised PVC (UPVC) pipes of 50mm bore and having pressure rating 6 Kgf / cm² laid in trenches including all fittings and fixtures all as specified and as directed (Make : SUPREME / PRINCE / ASTRAL / PRAYAG)
S&F Unplasticised PVC (UPVC) pipes of 15mm bore and having pressure rating 10 Kgf / cm laid in trenches including all fittings and fixtures all as specified and as directed (Make : SUPREME / PRINCE / ASTRAL / PRAYAG)
Supplying and laying of CPVC pipes of outer dia 20mm, SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed (Make : SUPREME / PRINCE / ASTRAL / PRAYAG)
M&L for Well burnt Sub class 'B', modular bricks laid dry, flat, over the cable abutting each other, length of brick equal to width of brick, complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by the Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed by the Engr-in-Charge.
M & L for providing plain cement concrete, type D-2, (1:4:8) (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, (1:3:6) (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete type B-1, (1:2:4), (using 20 mm graded stone aggregate), as in pole coping and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Labour only for unloading of Manganese Dioxide compound from the old unserviceable Oxidation Chamber of capacity 10,000 GPH and stacking aside for removal from site complete all as specified and directed.
Labour only for unloading of filter media from the Iron Removal Plant of capacity 10,000 GPH and stacking aside for removal from site complete all as specified and directed.
Labour only for unloading of unserviceable resin from the Iron Removal Plant of capacity 10,000 GPH and stacking aside for removal from site complete all as specified and directed.
Dismantling and taking down old Pressure Filter cum Iron Removal Plant of capacity 10000 GPH including following accessories and stacking aside for removal from existing site to another site for re-installation purpose or for replacement complete after disconnection of all frontal pipe lines, air lines etc. :-
Oxidation Chamber including all accessories
Pressure Filter cum Iron Removal Plant
Water Softener Plant including all accessories
Salt Chamber
Air Compressor Unit including Motor and other accessories etc.
Shifting of following dismantled accessories to a new site not more than 500 mtr away from existing site by using adequete manpower and Hydraulic Crane, JCB etc. and installed rigidly by providing foundation bolt , nut etc. on newly constructed platform / Pillar complete all as specified and as directed :-
a) Pressure Filter cum Iron Removal Plant
b) Water Softener Plant including all accessories
Dismantling and taking down old Iron Shell of water Softening Plant of Pressure Filter cum Iron Removal Plant of capacity 10000 Gph including all accessories and stacking aside for removal from existing site to another site for re-installation purpose complete after disconnection of all frontal pipe lines
Shifting of dismantled accessories of water softening plant to a new site not more than 2.0 KM away from existing site by using adequete manpower and Hydraulic Crane, JCB etc. and installed rigidly by providing foundation bolt , nut etc.on newly constructed platform / Pillars complete all as specified and as directed.
Modification of Frontal Pipe Line of Iron Removal Plant, Activated Carbon Filter Plant, Softener Plant complete with all pipelines of suitable dia & length duly cut into size & shape including necessary welding work by providing M.S.heavy duty pipe of dia 80 / 100 mm, MS flange, MS bolts, nuts, washers etc. all as per requirement at site.complete as specified and as directed.
M&L for painting of inside surface of Iron Removal Plant of dimension 3000 mm dia x 5100 mm height (including dish plate & bed plate) with two coats of drinking water quality paint complete with dish plate and bed plate and outside surfaces with two coats of Red Oxide Metal primar and two coats of synthetic enamel paint all as specified and as directed.
M&L for painting of inside surface of Activated Carbon Chamber of dimension 1750 mm dia x 4100 mm height (including dish plate & bed plate) with two coats of drinking water quality paint complete with dish plate and bed plate and outside surfaces with two coats of Red Oxide Metal primar and two coats of synthetic enamel paintall as specified and as directed.
M&L for painting of inside surface of Water softener plant (Resin Chamber) of dimension 1600 mm dia x 3500 mm height (including dish plate & bed plate) with two coats of drinking water quality paint complete with dish plate and bed plate and outside surfaces with two coats of Red Oxide Metal primar and two coats of synthetic enamel paint all as specified and as directed.
S&F Strainer Nozzle (Threaded or push fit type) suitable for fixing in Iron Removal Plant, Softening Plant etc. duly made of virgin quality HDPE / LDPE materials as per existing specification all as specified and as directed.
Supply and charging of catalyst Manganese Dioxide (MNO2) inside the oxidation chamber complete all as specified and as directed.
Supply, cleaning and filling the pressure filter gravel / filter media of size 4mm to15 mm complete all as specified and as directed. (Source: Barakar river.)
Supply, cleaning and filling the pressure filter gravel / filter media of size 20mm to 25 mm complete all as specified and as directed. (Source: Barakar river.)
Supply, cleaning and filling the pressure filter gravel / filter media of size 25mm to 40 mm complete all as specified and as directed. (Source: Barakar river.)
Supply, cleaning and filling the coarse sand inside the pressure filter (type of sand 16/30 mesh) complete all as specified and as directed. (Source: Barakar river.)
Supply and charging of coconut based granular Activated Carbon (Mixture of 6mm -12mm & 3mm - 6mm granules) inside the oxidation chamber complete all as specified and as directed.
Supply and pouring resin inside beds of softening plant chamber complete all as specified and as directed. (Make :- Zeolite 320/ Thermax/ Indion 225 NA)
Dismantling the Air Compressor unit including motor from their base by disconnecting belts etc. and taking out unserviceable spare parts / components and to carryout following works and reassembling the units to make the total compressor unit serviceable : (a) Replacement of Piston Ring - 01 set (b) Replacement of connecting Rod - 1 No. (c) Replacement of gudgen pin - 1 No (d) Replacement of Piston of suitable size - 1 No (e)Replacement of Compressor Oil of suitable grade - 2.0 Ltr (f) Cleaning the stator coil of the 3 phase 5.0 HP motor - 1 Job (g) Varnishing of entire stator coil with Dr Beck insulating Varnish - 1 Job (h)Heating of stator coil to make the varnish dry - 1 job (j) S&F rubber machine mounting pad under the MS Frame of compressor unit to avoid vibration - 4 Nos (k) Painting of total compressor-motor unit withone coat of red oxide metal primar and two coats of synthetic enamel paint - 1 job (l) Replacement of worn out rubber V- belt of suitable size (m) Replacement of high pressure cutout switch - 1 No.
S&F M.S. Flange / Dummy Plate 8 mm thick of suitable dia compatable with frontal pipe line of filter assembly and the diaphragm valve including necessary electric arc welding and for pipe sizes as under :
S&F Cast Iron Diaphragm Valve made in accordance with BS-10 Table -D or As per ISS along with rubber gasket, M.S. Bolt of suitable dia and length complete of bore as under :- (Make : VENUS / RMCo / KIRLOSKAR / NKI / SUN)
S&F Cast Iron Butterfly Valve made in accordance with IS : 13095 alongwith rubber gasket, M.S. Bolt of suitable dia and length complete of bore as under :- (Make : VENUS / RMCO / KIRLOSKAR / KARTAR)
S&F MS ERW pipe medium grade including necessary drilling, welding, provision of branch connections etc. all as specified and as directed including one coat of Red Oxide metal primar and two coats of synthetic enamel paint complete for bore of pipe 100mm.
S&F Salt chamber (with lead) of dimension 1300 mm dia x 1250 mm height, for preparation of brine solution, made of 6.0 mm thick MS sheet duly anti corrosive Rubber / FRP coating on all inside surfaces including painting of outside surfaces with one coat of red oxide metal primar and two coats of synthetic enamel paint complete with inlet, outlet and wash out line all as specified and as directed.
S&F Oxidation Chamber of dimension 1.0 mtr dia x 1.00 mtr height, made of 6.0mm thick MS plate, 8.0mm thick dish plate and 8.00mm thick bed plate and provision of water inlet / outlet pipe line, 15mm air inlet line, MnO2 filling hole with cover complete including painting with one coat of red oxide metal primar and two coats of synthetic enamel paint all as specified and as directed.
S&F 3 layer PP-R (Polypropylene random copolymer) pipe 63mm outer diameter, SDR 7.4 (PN 16) UV stabilized antimicrobial fusion welded having therma stability for hot and cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches all as specified and directed.
Supply and laying pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia laid in trenches.
Supply and fix Cast Iron Non Return Valve, Horizontal type with by-pass Arrangement, 80 mm (3”) dia complete with Rubber gasket of suitable thickness, M.S.Bolts, nuts and washers of suitable size all as specified and as directed.
S&F Gun Metal / Bronze Gate Valve, ISI marked, with iron wheel head, screwed both ends for iron pipe of bore 80mm .
Supply and laying pipe galvanized Steel , “Medium class”, including fittings 50 mm (2”) dia laid in trenches.
S&F Gun Metal / Bronze Gate Valve, ISI marked, with iron wheel head, screwed both ends for iron pipe of bore 50mm.
Supply & Fixing of Monoblock centrifugal pump set suitable for operate with 3 Phase, 415 Volt AC 50 Hz supply and having ingress protection level IP-55, Class of insulation 'F', ISI Marked complete with bronze impeller, Stainless Steel shaft and all necessary hardware and pipe fittings / gasket. The pump set shall be duly fixed on rubber mountings and necessary electrical / earthing connection complete suitable to meet the following parameters : a) Operating Head : 43.5 Mtr b) Discharge : 9.0 LPS c) Capacity : 10.0 HP d) Suction : 65mm e) Delivery : 65 mm f) Rated RPM : 1450 Make : Kirloskar Brothers Limited (Model : KDI 1050+) or Equivallent model of KSB / CROMPTON Note : Electrical cables and earth lead conductors shall be measured and paid separately under respective items as mentioned in the schedule.
Supply & Fixing of Monoblock centrifugal pump set suitable for operate with 3 Phase, 415 Volt AC 50 Hz supply and having ingress protection level IP-55, Class of insulation 'F', ISI Marked complete with bronze impeller, Stainless Steel shaft and all necessary hardware and pipe fittings / gasket. The pump set shall be duly fixed on rubber mountings and necessary electrical / earthing connection complete suitable to meet the following parameters : a) Operating Head : 22.0 Mtr b) Discharge : 6.0 LPS c) Capacity : 3.0 HP d) Suction : 65mm e) Delivery : 50 mm f) Rated RPM : 1450 Make : Kirloskar Brothers Limited (Model : KDS 325++) or Equivallent model of KSB / CROMPTON Note : Electrical cables and earth lead conductors shall be measured and paid separately under respective items as mentioned in the schedule.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1000mm Height (Without Canopy & legl) x 750mm width x 300mm Depth, 450mm long M.S. Angle leg (40mmx40mmx6mm) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 60 amps, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer sheet and 2.0mm thick for inner doors/partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 4 side slanting canopy type roof on top and mild steel Angle leg at bottom, suitable for mounting on the brick pedestal / PCC Floor through grouting. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
(a) TPN MCB 40 Amps (10 KA) - 1 No (LEGRAND / C&S / L&T / ABB) (b) Aluminium Bus Bar of rating 60 Amps duly insulated and rigidly mounted on FRP / DMC Insulators - 1 Set of 4 Bus Bars. (c) TP MCB 20 Amps (10 KA) - 2 Nos. (LEGRAND / C&S / L&T / ABB) (d) TP MCB 16 Amps (10 KA) - 2 Nos. (LEGRAND / C&S / L&T / ABB) (e) Fully Automatic Star-Delta Motor Starter with external ON/OFF Push Button & Green coloured LED Lamp complete suitable for 10.0 HP motor - 2 Nos ( Internal Components shall be of make L&T / C&S / BCH) (f) Direct on Line Motor Starter with external ON/OFF Push Button & Green coloured LED Lamp complete suitable for 5.0 HP motor - 2 Nos ( Internal Components shall be of make L&T / C&S / BCH)
S&F 100 mm dia Dial type Water Pressure Guage (glycerene Filled) suitable for line pressure of 10 Kg/Sqcm complete with necessary adopter etc. (Make : FIEBIG / K-GURU / RMCO)
S&F PVC insulated Round / Flat PVC sheathed copper cable of 10 sqmm 3 core with stranded copper wire laid in ducts. (For Pump Starter Panel to 15 HP Booster Pump) (Make : HAVELLS / FINOLEX / POLYCAB)
S&F PVC insulated Round / Flat PVC sheathed copper cable of 6 sqmm 3 core with stranded copper wire laid in ducts. (For Pump Starter Panel to 10 HP Booster Pump / 7.5 HP Submersible Pump) (Make : HAVELLS / FINOLEX / POLYCAB)
S&F PVC insulated Round / Flat PVC sheathed copper cable of 4 sqmm 3 core with stranded copper wire laid in ducts. (For Pump Starter Panel to 5.0 HP Compressor Motor / 3.0 HP Backwashing Pump Pump) (Make : HAVELLS / FINOLEX / POLYCAB)
S&F PVC insulated Round PVC sheathed copper cable of 1.5 sqmm 2 core with stranded copper wire laid in pipes. (For Automatic operation of Chlorine Dozing Pump) (Make : HAVELLS / FINOLEX / POLYCAB)
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core (Make : HAVELLS / FINOLEX / POLYCAB)
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core (Make : HAVELLS / FINOLEX / POLYCAB)
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core (Make : HAVELLS / FINOLEX / POLYCAB)
Supply, laying, testing of cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire , armoured heavy duty electric under ground LT cable 1100 volts grade with solid copper conductor of size 10.0 Sqmm 3 core (Make : HAVELLS / FINOLEX / POLYCAB)
S&F Water Pressure Switch suitable to fixing in the CI / GI pipe line including providing necessary drilling in the pipe line, welding of socket with the pipe line, provisioning of suitable adopter to fix the switch with the socket complete with following specification :- (a) Maximum Working Pressure : 6 Kg / Sq cm (b) Type of Electrical Contact : 1 NO + 1 NC (Minimum) (c) Working Voltage : 230 Volts, 50 Hz, Single Phase AC Supply. (Make : DANFOSS / INDFOSS)
Supply, testing,installation and commissioning liquid chlorine dozing pump, consisting of high pressure single head gear motored adjustable dozing pump with accessories such as lead tubing, connecting nuts, injection check valves,clay weight and ferrules including necessary piping work for inlet / outlet and connecting with nearby electrical sockets / Points all as described and as directed by Engineer-in- Charge. Specification of the pump :- (a) Adjustable Injection Pressure : 0 to 100 PSI ( +/- 5% ) (b) Discharge : 2.0 GPD TO 40.0 GPD (+/- 5%) (c) RPM : 44 (+/- 5%) (d) Input Supply : 230 Volt, 50 Hz AC Supply (e) Rated Power Input : 1/30 H.P. (+/- 5%) (Model : 96NGQ51, Make : DECLIBAC TECHNOLOGIES (P) LTD) OR Model :RPQ - 40 - HD (Make RMCo) OR Equivallent model in : MILTON ROY
Liquid Chlorine Dozing System complete with following accessories, suitable to work with 230 volts ,50 Hz, single phase AC supply :- (a) 100 Ltr capacity PE / FRP Tank with lead and level guage along with Agitator (1280 rpm) and FRP / Epoxy coated stailess Steel (SS 316) Shafts & Blades and necessary holes in the lead for fixing the shaft and pouring the chemicals. (b) Single Phase Electric Motor of capacity 90 watt (1440 rpm) with insulation class B, capable to withstand temparature rise of 75 degree Celcius above ambient Model :- ADS-I (Make : DECLIBAC TECHNOLOGIES Pvt Ltd.) OR Model :- CDS- 100 (Make : RMCo) OR Equivallent model in MILTON ROY
Labour only for trimming of tree branches upto 9.0 mtr above ground level by providing suitable ladders, safety belts, electric / petrol driven chain saw and removing the treamed branches to a distance not more than 100 metres from the starting point and staking properly all as specified and as directed. Note : The gross volume of stacked material shall only be considered for measurement
S&F of M.S. Plate 8.0mm thick, cut into shape, drilled and welded with the reinforcement of the foundation pillars of IR Plant & Activated Carbon Filter Plant to accommodate the above filters on it and necessary welding with the base plate of the filter to mount them rigidly on the RCC Columns complete all as specified and as directed.
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 800 mm Height (Without Canopy & Base Channel) 1000 mm width x 400 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick / PCC. pedestal of height 600 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables. The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer shell & canopy and 2.0mm thick for inner doors / partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility with double layer shutter and rear opening facility with single layer shutter with locking facility and 4 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 100 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size 1100 v grade PVC insulated copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLSH grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- MCCB 63 Amps (16 KA) 4 Pole Adjustabble thermal (80% to 100%) and fixed magnetic protection -01 No
Note:- (a) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (b) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (c) All the inner / outer doors should have locking facility through castle locks (d) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (e) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (f)The thickness of MS Sheet for outer shell and canopy shall be of 3.0mm and inner doors and partitions shall be of 2.0 mm (g) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (h) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Location : Near Park Area
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1500 mm Height (Without Canopy & Base Channel) 1600 mm width x 450 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick / PCC. pedestal of height 600 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 300 amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables. The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer shell & canopy and 2.0mm thick for inner doors / partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility with double layer shutter and rear opening facility with single layer shutter with locking facility and 4 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 300 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size PVC insulated aluminium strip as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLSH grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) MCCB 200 Amps (16 KA) 4 Pole Adjustabble thermal (80% to 100%) and fixed magnetic protection and with rotary handle - 01 No (ii) Open execution type Front operated 4 Pole onload Changeover Switch of rating 200 Amps - 01 No. ( HAVELLS - EUROLOAD / L&T / HPL - SOCOMEC )
Note : (a) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (b) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (c) All the inner / outer doors should have locking facility through castle locks (d) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (e) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (f)The thickness of MS Sheet for outer shell and canopy shall be of 3.15mm and inner doors and partitions shall be of 2.0 mm (g) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (h) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Location : Near KMC Pump House
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1500 mm Height (Without Canopy & Base Channel) 1600 mm width x 450 mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick / PCC. pedestal of height 600 mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 250 Amps, Provision of Spreader link to both incoming and outgoing side of MCCBs for termination of cables. The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-54 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA Stainless steel sheet for outer shell & canopy and 2.0mm thick for inner doors / partations and 3.15mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility with double layer shutter and rear opening facility with single layer shutter with locking facility and 4 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 250 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size 1100 v grade PVC insulated copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm CONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLSH grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges. INCOMING :- (i) MCCB 160 Amps (16 KA) 4 Pole Adjustabble thermal (80% to 100%) and fixed magnetic protection and with rotary handle - 01 No
Note : (a) All incoming & outgoing feeders to be marked with aluminium name plates duly rivetted on the front inner door of the feeder pillar. (b) All the cable entry / exit will be through bottom only, duly glanded with single compression type brass cable gland of suitable size. Cost of end termination of cable shall deemed to be included in the cost of feeder pillar. (c) All the inner / outer doors should have locking facility through castle locks (d) Cost of all civil work for brick pedestal, duly plastered, shall deemed to be included in the unit rate quoted, no separate payment shall be allowed for this. (e) The dimention of Panel Board as mentioned above is tentative. If it is required to be enhanced to accomodate the switchgears and maintaining the gaps as per IE Rules, it should be enhanced as per requirement without any extra cost to the department. (f)The thickness of MS Sheet for outer shell and canopy shall be of 3.15mm and inner doors and partitions shall be of 2.0 mm (g) The Panel Board should be designed in such a way that adequete workable space is made available inside every compartments. (h) The drawing of the Panel Board shall have to be got approved by Garrison Engineer before starting of fabrication process. Location : Near Old JCO's Mess/Senapati Bhavan
Supply and fix steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with CI / MS base plate and finial tapper plug, bolts, nuts complete with painting one coat of red oxide and two coat of aluminium paint with dismantling of old unserviceable Steel pole of any size all as specified and directed.
S&F Weather Proof thermo plastic (Polysterene) Cable Junction box, having minimum ingress protection level IP-55 and of overall size not less than 155mm x 210mm x 92mm (Approx) having provision of metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 3 Nos polymide weather proof cable glands of cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps 4 Way cable connector and 1 No. 6 Amps SP MCB. Make of box & Connector : HENSEL / CAPE / ELETTRO Make of MCB : LEGRAND / HAVELLS / C&S / L&T
S&F Low Density Polyth Ethylene (LDPE) Pipes of pressure rating 6 Kgf / cm² fixed complete to walls, pedestals of polesor in trenches, ducts etc. all as specified and as directed for following sizes :-
40 mm bore
32 mm bore
S&F 3 core PVC insulated round flexible cable 1.0 sqmm multi stranded copper conductor flexible cables 1100 Volt grade complete and making connection from pole box to Flood light all as specified and directed. Make : HAVELLS / FINOLEX / POLYCAB
S&F LED Street Light Fittings having Ingress Protection class minimum IP-65 , suitable for road lighting luminaire with high power LED with high efficiency electronic driver unit and surge protection device to ensure uniform light distribution within higher spacing between poles for capacity 70 W all as specified and as directed including provision of new 40mm M.S. pipe bracket of length 75cm, duly welded with the pole and dismantling of old US light fittings of any type and any wattage from the existing pole. Make : Havells (Cat No. ENDURAOMNIPLUSSL70WLED757SASYTOPC) Crompton (Cat No: CRP-409-70-57-SL-GL-NSG) Bajaj (Cat No. BRTFG 72W LED V3)
S&F LED Flood Light Fittings having Ingress Protection class minimum IP-65 , suitable for area lighting with high power LED with high efficiency electronic driver unit and surge protection device to ensure uniform light distribution of capacity 120 W all as specified and as directed. all as specified and as directed. Make : Havells (Cat No. JETAIRISFL120WLED757ARNBLTG) Crompton (Cat No: LFLN-120-CDL/60-M) Bajaj (Cat No. BJFL 120W LED I)
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip of size 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 40 mm bore LDPE pipe and necessary fitting for protection of GI strip incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , UPVC funnel with 20mm bore UPVCI pipe (pressure rating 6.0Kgf/cm²) for watering and nylon mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete all as specified an directed. Note : All joints between earth plate and earth lead strip shall be carried out by electric arc welding for rigid connection.
Disconnection and taking out old unserviceable CI Sluice Valve of any size(80mm / 100mm) from existing unused pipe line complete all as specified and as directed
Dismantling and taking out old unserviceable CI / GI Pipe Line and stacking aside for removal from site of sizes as under :
80 mm bore
100 mm bore
Dismantling and taking out old unserviceable M.S. Sheet cover of Valvepit of any size including hinges, handles etc. complete all as specified and as directed.
Breaking of old unused Brick masonary Valve pit any type and any size and removing the debris from the site complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quoins,arches, pillars,etc. of any descriptions complete all as specified and directed.
Taking down cement plaster or lime plaster of any description from stone or brick wall /ceiling etc including raking out joints, hacking for key, scrubbing down with water and disposing off the rubbish materials out side MD land including neccessary working platform complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description, below or above ground floors (Floor Topping, sub base etc) not exc 150mm thick, above or below ground level complete all as specified and as directed.
M&L for hard core of gauge n.exc 63mm,deposited spread and levelled in layer n exc 15cm thick watered and rammed to a true surface of broken stone boulders.
Material and Labour for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and as directed.
Material and Labour for brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed.
Material and Labour for Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed.
Material and Labour for laying silver sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Material and Labour for Providing plain cement concrete type B1 (1:2:4) (using 20mm graded stone aggregate) as in coping and the like including weathering, slightly rounded or chamferred angles and throating as complete all as specified and as directed.
Material and Labour for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick walls or concrete surface, finishing even and smooth (without using extra cement)etc including necessary working platform complete all as specified and as directed.
M & L Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
All as per item No 87 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Demolition of cement concrete (reinforced) in ground floor and paving not exc 15 cm thick (below or above G.L) complete all as specified and directed.
M & L for Reinforcement Cement concrete Type B1 1:1.5:3 (20mm graded stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for reinforcement cement concrete Type B1 1:1.5:3 (20mm graded stone aggregate) in Column, pillars, posts and struts etc, complete all as specified and directed.
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough fished to cement concrete etc complete all as specified and directed.
Use and waste of Formwork to edges of rough finished concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide etc complete all as specified and directed.
M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc complete all as specified and directed.
Material and Labour for 75mm thick PCC (1:3:6), type C2, (using 40mm graded stone aggregate) as in plinth protection / paving, surfae finished even & smooth without using extra cement as complete all as specified and as directed.
Material and Labour for two coat of weather proof exterior emulsion paint on new surface or previously untreated surface of external walls including preparation to remove all foreign materials including necessary working platform complete all as specified and directed.
DEB AND COMPANY
DILIP CONSTRUCTION
RADHA ENTERPRISE
TOTCO
M. M. C. AND CO
THE PLANTERS ENGINEERING CORPORATION
SK CONSTRUCTION SYNDICATE & ENGG CO
NICE INFOTECH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .