Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹40.5 L+₹3.1 L (8.28%)Rejected-Finance H M APARTMENT FLAT NO 5C SJ ROAD ATHGAON GUWAHATI 781001 ASSAM | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹41.6 L+₹4.2 L (11.3%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹41.9 L+₹4.5 L (12.1%)Rejected-Finance BAM GAON SILAPATHAR DIST DHEMAJI ASSAM | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹42.8 L+₹5.5 L (14.7%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
20 Nov 2021, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
SPECIAL REPAIRS TO BLDG NO. T-09 OF INF PRO UNIT, SPECIAL REPAIRS TO BLDG NO. OWT-20 TO OWT-24 OR LIVING SHELTER OF INF DIV ORD UNIT, SPECIAL REPAIRS TO BLDG NO. P-15 (BSO OFFICE AND T-16 (BSO YARD) OF GE 872 EWS, SPECIAL REPAIRS TO BLDG NO. T-21/2 (
2021_MES_482986_1
8647/T-47/E8
Open Tender
Miscellaneous Works
Item Rate
183 days
LIKABALI
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE 872 EWS
₹97,000
Yes
15 Jan 2022
21 Oct 2021
22 Nov 2021
21 Oct 2021
20 Nov 2021
8 Nov 2021
21 Oct 2021 - 26 Oct 2021
Amount
B/R SERVICES/WORKS
Demolition Cement Concrete (Un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and Removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed
Demolition Brick Work or Pre-cast Concrete Block Masonry, built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., Segregating Serviceable Brick or Pre-cast Cement Concrete Blocks and Stacking properly at Sites and Keep in Safe Custody for re-use, complete all as specified and as directed.
Dismantling Timber Scantlings 40 Sq Cm and Over in Section in Unframed Work, Seggregating Serviceable Timber Scantlings and Keep in Safe Custody for Refixing/ Reuse, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame), not exc. 1.50 Square Metre Each, complete all as specified and as directed.
Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame), exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed.
Taking down Shutter of any description, not exc. 1.00 Square Metre Each, complete all as specified and as directed.
Taking down Shutter of any description, exc. 1.00 Square Metre but not exc. 2.00 Square Metre Each, complete all as specified and as directed.
Taking down/out Unserviceable Rusted/ Worn out Wire Cloth/Netting of any description, fixed with Beads, etc., complete all as specified and as directed.
Hacking out Old Broken Glass (any thickness, size, quality or description) from Wooden or Metal Frame or Stone, Concrete or Brick surrounds including hacking out old Putty or removing Beads, etc., punching or drilling out old Glazing Pins/Spring Clips, complete all as specified and as directed.
Dismantling Plain or Corrugated Steel Sheeting of any gauge and thickness, Segregating the Serviceable Plain or Corrugated Steel Sheeting and Stacking properly at Sites and Keep in Safe Custody for re-use, complete all as specified and as directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/ Slabs/ Blankets of any descriptions including Cover Fillets, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and Removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed.
Taking down Cement Plaster including Raking out Joints, Hacking for Key, scrubbing down with Water and Removing Debris, etc. etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed.
Taking up or down Steel Tubing 15mm bore (dia) and Fittings, Segregating the Serviceable Pipes and Fittings, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking up or down Steel Tubing 20mm bore (dia) and Fittings, Segregating the Serviceable Pipes and Fittings, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed.
Taking down/ out PVC (SWR) Rain Water Pipe, Soil, Waste, Ventilating Pipe, etc. of any Size including connected Fittings of any description, complete all as specified and as directed.
Excavating in Post Holes (or Similar Holes) in Soft/Loose Soil, Each not exc. 0.50 CUM, getting out and Removing Surplus Soil to a distance not exc. 50.00 Metre and Making Good Surfaces, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded aggregate) for embedding Mild Steel Work as Posts, etc. in Foundations, Filling and Mass Concrete, etc. including necessary Formwork, complete all as specified and as directed. NOTE : Cost of Formwork will deemed to be included in Quoted Unit Rate.
M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks of Size 300x200x200mm or 300x200x100mm, having Compressive Strength of not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregate), exc. 10 Cm in Width and Setting in Cement Mortar 1:6, complete all as specified and as directed.
M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks of Size 300x200x200mm or 300x200x100mm, except Pre-cast Cement Concrete Blocks (Serviceable Pre-cast Cement Concrete Blocks obtained from BOQ Item No. 1.002 here-in-before), exc. 10 Cm in Width and Setting in Cement Mortar 1:6 including Removing Mortar from and Cleaning Pre-cast Cement Concrete Blocks, Removal and disposing off Rubbish, etc., complete all as specified and as directed.
M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks of Size 300x200x100mm, having Compressive Strength of not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregate), 10 Cm in Width and Setting in Cement Mortar 1:4, complete all as specified and as directed.
M&L Cutting Holes in Brick/ Pre-cast Concrete Block Walling, not exc. Half Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregate) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) in Scantling, Cleanswan, Timber fixed (Unframed work), fixing with Nails, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) in Scantling but except Timber (Serviceable Timber Scantling obtained from BOQ Item No. 1.003 here-in-before), Timber fixed (Unframed work), fixing with Nails, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Panelled Shutter 35mm thick (any number Panels) Plain, Framed with Lock Rails, having Panels of 12mm thick BWP, Commercial Ply or 12mm thick Veneered Particle Board Medium density, Wood Particle Board with Commercial Face Veneers and fitted to Chowkat, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 35mm thick, Open rebated and prepared to receive Glass, Gauze, etc., divided into Squares, with plain, chamfered or rounded, mitred and rebated Sash Bars (any numbers), fitted with cut and mitred beads for Glass, Gauze, etc., Sizes of Members of Shutters as specified in MES Schedule Part-I, Section 8, Clause No. 8.24(a) and fitted to Chowkats, complete all as specified and as directed.
M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, Open rebated and prepared to receive Glass, Gauze, etc., divided into Squares, with plain, chamfered or rounded, mitred and rebated Sash Bars (any numbers), fitted with cut and mitred beads for Glass, Gauze, etc., Sizes of Members of Shutters as specified in MES Schedule Part-I, Section 8, Clause No. 8.24(b) and fitted to Chowkats, complete all as specified and as directed.
M&L Anodised Aluminium Powder Coated (thickness of Powder Coating not less than 50 micron) Frame for Doors, Windows, Ventilators with One or More Rebates including Joining Cleat for fixing, etc., complete all as specified and as directed.
M&L Anodised Aluminium Powder Coated (thickness of Powder Coating not less than 50 micron) Door Shutters, Aluminium Section weighing not less than 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber/ Neoprene Packing, Handles (as approved) - 2 No. in Each Door, Stainless Steel Hinges of Size as ordered, anodised Aluminium Snap Beading, Screws, etc, complete all as specified and as directed. NOTE : Cost of Aluminium Fittings/ Builders Hardware as metioned here-in-above will deem to include in the Quoted Unit Rate.
M&L Anodised Aluminium Powder Coated (thickness of Powder Coating not less than 50 micron) Window and Ventilator Shutters, Side Hung type without Sash Bars, Aluminium Sections weighing 0.55 KG/RM including necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings such as Peg Stays 150mm long (1 No.). Hinges Type B-21, 100mm long (2 No.) suitable Handle (1 No.), complete all as specified and as directed. NOTE : Cost of Aluminium Fittings/ Builders Hardware as metioned here-in-above will deem to include in the Quoted Unit Rate.
S&F Steel Windows with Side Hung Shutters including Projecting type Hinges with Steel Handle and Steel Peg Stay, complete with Glazing Bars, dovetailed or welded, complete all as specified and as directed.
S&F Aluminium anodised Barrel Tower Bolt of Size 125mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium anodised Barrel Tower Bolt of Size 150mm long, Extruded Section, complete all as specified and as directed.
S&F Aluminium alloy, anodised, Sliding Door Bolt 300mm long (as approved) with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge of Size 75mm, complete all as specified and as directed.
S&F Stainless Steel Butt Hinge of Size 100mm, complete all as specified and as directed.
S&F Aluminium Handle of Size 125mm, anodised, Cast type, complete all as specified and as directed.
S&F Aluminium Handle of Size 150mm, anodised, Cast type, complete all as specified and as directed.
S&F Floor Door Stopper with Overall length of Cover Plate 140mm of Aluminium Alloy Body and Tongue, anodised, with Hard Drawn Steel Spring, fixed in Floor, complete all as specified and as directed.
S&F Floor Door Stopper with Overall length of Cover Plate 150mm of Aluminium Alloy Body and Tongue, anodised, with Hard Drawn Steel Spring, fixed in Floor, complete all as specified and as directed.
S&F Mild Steel 300mm, Ordinary Rat Tail Rod Pattern Springs including Roller and Roller Plate and Fixed-in-repairs, complete all as specified and as directed.
S&F Mild Steel Mortice Lock, Vertical type, Size 65mm with 4-Lever, complete all as specified and as directed.
M&L Stainless Steel Curtain/ Drapory Rod having 24mm Outer dia with Wall thickness 1.00mm (minimum) including Brackets, Side Holders and Rings, etc. and Fixed-in-repairs, complete all as specified and as directed.
S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed.
S&F Sheet Glass 3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed.
M&L Mild Steel Bands, Straps, Supports or Stays for Rain Water, Ventilating Pipes including Bolts (if required), Heavy Hooks (Stay) for Large Gates; Hook and Pintle Hinges, Large Hasps and Staples; Chains; Hand Made Sliding Bolts; Clamps; Holdfasts (Flat Iron 25x3.0mm); Wall Ties; Hooks for Hanging Fans; Plain Angle Cleats for securing Purlins to Wood Trusses or Rafters; Knee Piece inserts; 2-way and 3-way Straps, Plate Washers and Similar Small Articles, conform to Fe-290 Gde-E-165, complete all as specified and as as directed.
M&L Mild Steel Framed Work such as Grills, Gratings, etc, with Ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walkways, Railings, Frame Work of Water Tanks and Similar Works, conform to Fe-290, Gde E-165, complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Joist, Channel, Angle, or Tee Sections in Vertical Post, conform to Fe-410-W (Gde E-250) Quality 'B', fixed independently, without Connecting Plates, etc. (cut to ordinary lengths i.e. within 20mm of the Length indicated), complete all as specified and as directed.
M&L Rolled Mild Steel Sections in Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails and Fastenings and Heavy Bracket Framing (Beam, Tee, Angle, Channel or Flat Sections) including Distance Pieces, Cleats, etc, conform to Fe-410-W (Gde E-250), Quality 'B', complete all as specified and as directed.
M&L Plates (Plain or Chequered) Channels, Square cut or Notched (Ordinary and Counter Sunk) forming Holes, without any Aattachment, conform to Gde Fe-410-W (Gde E-250) Quality 'B', complete all as specified and as directed.
M&L Mild Steel Screw Bolts (Machine made) of any description or Size, with Hexagonal or Square Heads at One End and screwed the Other End, or screwed Both Ends, Each screwed End to be fitted with Washers and One Hexagonal or Square Nut, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Pre-painted Galvalume Corrugated Steel Sheet, except Sheets (Serviceable Pre-painted Galvalume Corrugated Steel Sheet obtained from BOQ Item No. 1.010 here-in-before) in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
S&F Pre-painted Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/ Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed.
M&L Exposed Suspended False Ceiling System with GI Powder Coated Snap Grid/ Frame Work of size 605x605mm, all as per Specification and Drawing of MES Schedule (except Hangers), complete all as specified and as directed.
S&F Hangers 4.0mm dia GI (upto 1200mm length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
S&F HSPC Non-Asbestos Fibre Cement Building Boards 4.0mm thick, Pre-primed, Self Embossed, Textured Designer Boards, Water Resistant, Termite Resistant, Fire Resistant for insulation, fixed or laid/ inserted to GI/ Aluminum Snap Grid Frame Work with Screws, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 50mm thick in Flooring, etc., laid in Alternate Panels, finished Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) 40mm thick in Flooring, etc., laid in Alternate Panels, finished Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed.
M&L Glass Dividing Strips 38mm Wide and 3.0mm thick and inserted in Position, conform to Design, complete all as specified and as directed.
M&L Non-skid Ceramic Coloured/Designer Tiles, Joint Free (1st quality and as approved) 7.0mm to 8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Cement Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Non-skid Ceramic Coloured/Designer Tiles, Joint Free (1st quality and as approved) 7.0mm to 8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.11 Sqm but not exc. 0.18 Sqm in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Cement Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Non-skid Ceramic Coloured/Designer Tiles, Joint Free (1st quality and as approved) 7.0mm to 8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Cement Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Non-skid Ceramic Coloured/Designer Tiles, Joint Free (1st quality and as approved) 7.0mm to 8.0mm thick (Square/ Rectangular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Cement Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Glazed Ceramic Coloured Tiles 300x200x6.0-7.0mm thick (1st quality and/or as approved) in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Cement Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed NOTE : Cost of Cement Screed Bed will deem to include in Quoted Unit Rate.
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L Rendering 15mm thick on Bricks/Pre-cast Blocks or Concrete Works consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:4 and Float/Top layer 5.0mm thick in Cement Mortar 1:4 including mixing WPC to Float/Top layer, finished Fair and Even, complete all as specified and as directed NOTE : Water Proofing Compound (WPC) will be Measured and Paid separately under appropriate Item.
Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed.
M&L Preparing New Plastered Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion (of approved Tint) over a Coat of Chalk Whitening (Priming Coat), complete all as specified and as directed.
M&L Preparing Old Distempered and Painted Surfaces of Walls by Washing, Rubbing down and Stopping of Surfaces and applying One Coat of Distemper Oil Emulsion (of approved Tint), complete all as specified and as directed.
M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Cement Based Paint (of approved Tint) over a coat of Alkali Resistant Priming Paint, complete all as specified and as directed.
M&L preparing Old Decorated/Treated Plastered Surfaces of Walls and applying One Coat of Cement Base Paint (of approved Tint), complete all as specified and as directed.
M&L Preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Pink Primer, complete all as specified and as directed.
M&L Preparing Old Painted Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying One Coat of Synthetic Enamel Paint (1st quality Paint of approved Tint), complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of any descriptions, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of Sheets on Roofing, Walls, etc., over 10 Cm in Width or Girth and applying a Coat of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed.
M&L Preparing Steel and Iron Surfaces of Sheets on Roofing, Walls, etc., over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing Old Rusted/ Treated Steel and Iron Surfaces of Sheets on Roofing, Walls, etc., over 10 Cm in Width or Girth and Applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed.
M&L Preparing New or Previously Treated Surface of Wood and Wood based Materials of any description and girth and treated with Two Coats of Creosote Oil, complete all as specified and as directed.
M&L Preparing previously Untreated Surfaces of Wood and Wood Based Materials, of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Backs of Chowkats, etc. Area tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
M&L Preparing previously Untreated Surfaces of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Holdfast or similar Small Items, Area tarred not exc. 0.10 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed.
S&F Galvanised Steel Tubing 15mm bore (dia), medium grade, conforming to IS-1239 with all Fittings, fixed to Walls, Ceiling or laid in Floors, complete all as specified and as directed.
Refixing old Steel Tubing 15mm bore (dia) and Fittings (Serviceable Pipes and Connections obtained from BOQ Item No. 1.014 here-in-before) in New or Old Position (Walls, Ceiling, Floors, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings (as required ordered at Sites), complete all as specified and as directed.
S&F Galvanised Steel Tubing 20mm bore (dia), medium grade, conforming to IS-1239 with all Fittings, fixed to Walls, Ceiling or laid in Floors, complete all as specified and as directed.
Refixing old Steel Tubing 20mm bore (dia) and Fittings (Serviceable Pipes and Connections obtained from BOQ Item No. 1.015 here-in-before) in New or Old Position (Walls, Ceiling, Floors, etc.) including Cleaning both Inner and Outer Surfaces of Pipes by using Wire Brush including provision of New GI Fittings (as required ordered at Sites), complete all as specified and as directed.
S&F Bib Tap 15mm bore (dia) Cast Copper alloy, Chromium Plated, with Crutch or Butter-fly Handle, screwed down, screwed for Iron Pipe or for Brass Ferrule and Fixed-in-repairs, complete all as specified and as directed.
S&F Pillar Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Swan Neck with Capstan Heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with Long Screwed Shanks and Fly-nuts, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
S&F Stop Valve/ Angle Cook 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, with Long Shank and Cup (Concealed type) screwed down, high pressure, with Crutch or Butter-fly handle, screwed both Ends for Iron Pipe or for Unions and Fixed-in-repairs, complete all as specified and as directed.
S&F Gun Metal Globe/Gate Valve 20mm bore (dia) with Iron Wheel Head, screwed both Ends for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
M&L Rotational Moulded Polyethene Water Storage Tank 500 Litre Capacity, Cylindrical, Vertical with Closed Top, 3 layered, conforming to IS:12701-1996, hoisted and fixed in Position all as specified in MES Schedule and providing Water Connections including Lowering down unserviceable Water Storage Tank of any description after disconning of all Water Supply Connections, complete all as specified and as directed.
S&F PTMT Ball Valve 20mm bore (dia), having weight not less than 210 Gram, high pressure with Epoxy Coated Aluminium Rod and high density Plastic Ball, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed.
M&L Vitreous China White Squatting Pan of Size 580x440mm, Orissa Pattern with Integral Foot Rests, PVC (SWR) ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incluiding provision of Lime Concrete Bedding and Making Good to distrubed/ Floor Surfaces, complete all as specified and as directed.
S&F PVC Flushing Cistern 10 Litre capacity White, Low Level, Valveless, Syphonic Action type with Inlet, Ball Valve, Float & Handle, and PVC Flush Pipe 32mm bore (dia) for suitable Length, a Pair of Cast Iron Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed.
S&F Vitreous China White Wash Hand Basin 550x400mm in Size, Oval shape, Counter Top with Brass Chromium Plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 40mm/32mm bore (dia) including a Pair of Cast Iron Brackets Brackets Erecting Stand duly Painted, Cutting and Pinning in Ends and Making Good disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed.
S&F PVC Connection Pipe 15mm in Size and 450mm in length with PTMT Nuts suitable for connecting with Flushing Cistern, Wash Hand Basin, etc., complete all as specified and as directed.
S&F PVC (SWR) Floor Trap having Diameter of Outlet 75mm, Plain with Grating including Jointing with Solvent Cement, complete all as specified and as directed.
S&F PVC (SWR) Pipe 75mm bore (dia), Single Socketed, in any length with Rubber Ring Joints, fixing to Walls, complete all as specified and as directed.
S&F PVC (SWR) Bend 75mm bore (dia), any Radius, etc. and Jointing with Solvent Cement, complete all as specified and as directed.
S&F PVC (SWR) Vent Cowl 75mm bore (dia), jointing with Solvent Cement, complete all as specified and as directed.
S&F PVC (SWR) Pipe 110mm bore (dia), Single Socketed, in any length with Rubber Ring Joints, laid in Trenches or in Floors, etc., complete all as specified and as directed.
S&F PVC (SWR) Pipe 110mm bore (dia), Single Socketed, in any length with Rubber Ring Joints, fixing to Walls, complete all as specified and as directed.
S&F PVC (SWR) Bend 110mm bore (dia), any Radius, etc. and Jointing with Solvent Cement, complete all as specified and as directed.
E/M SERVICES/WORKS
M&L Taking down carefully Copper Point Wiring (Light, Fan, Socket or Power) complete from in any Position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets but excluding Light Fittings of any description, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (White/Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Taking down Unserviceable Sub-main Wiring from PVC Conduit/ PVC Casing Capping of any description, Making Good disturbed surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (White/Colour Washing, Distempering, Painting, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 3/5 PIN SOCKET 6 AMP POINT on SAME BOARD, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable Size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 3/5 PIN SOCKET OUTLET 6/16 AMP POINT on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Run of 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated, unsheathed, multi-stranded, single core FRLSH Copper Conductor Cable (Green Colour) as Earth Continuty Conductor drawn through and including PVC Casing Capping (ISI Marked) of suitable Size (approx 25/32mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc., complete all as specified and as directed. NOTE :- (a) Cost of 3-Run of Cable & 1-Run of PVC Casing Capping will deem to be include in the Quoted Unit Rate and the same will be Mesured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Casing Capping only. Wires required/ as ordered for looping, etc. will deem to be include in the Quoted Unit Rate.
S&F PVC Rectangular Board/Block of Size 250x200x50mm Deep, Closed Recessed with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable Board/ Block (01 No.) of any description, complete all as specified and as directed.
S&F PVC Rectangular Board/Block of Size 350x300x50mm Deep, Closed Recessed with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc. including Taking down/ out Unserviceable Board/ Block (06 No.) of any description, complete all as specified and as directed.
S&F Switch Piano 6 Amp, Single Pole, Flush type, 1-way, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Switch Piano 146 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Socket Outlet 38 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Switch Socket Combination 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Switch Socket Combination 07 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Switch Socket Combination 6/16 Amp, 3 Pin, 2-in-1, Multi-plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Switch Socket Combination 07 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Switch Socket Combination 6 Amp, 3/5 Pin & 16 Amp, 3/5 Pin, Multi-plug, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Switch Socket Combination 07 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Lamp/ Angle Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Lamp/ Angle Holder 07 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Ceiling Rose 65x50mm, 3 Terminals, Surface Bakelite suitable for 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Ceiling Rose 93 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Ceiling Fan Regulator, Dimmar Switch type, 230 Volt AC, Rotary Stepped, Electronic, 120/280 Volt and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Fan Regulator 04 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F Ceiling Fan Regulator, Stepped type, Electronic, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. NOTE : Old Unserviceable Fan Regulator 11 No. obtained from Taking down of Point Wiring will be catered under Schedule of Credit.
S&F LED Adore 15 Watt, B-22 CDL, 3 Star Ball Lamp with 6500K including Taking down/ out Unserviceable Lamp (02 No.) of any description, complete all as specified and as directed.
S&F LED Bulk Head Light Fitting 1x6 Watt having Plastic Housing with Clear Prismatic Diffuser LED 6 Watt Lamp and connecting up with and including suitable Size and Length Twisted Flexible Copper Conductor Cable, complete all as specified and as directed.
S&F LED Bulk Head Light Fitting 1x10 Watt having Plastic Housing with Clear Prismatic Diffuser LED 10 Watt Lamp and connecting up with and including suitable Size and Length Twisted Flexible Copper Conductor Cable including Taking down Unserviceable Light Fitting (15 No.) of any description, complete all as specified and as directed.
S&F LED Tube Light Fitting 1x20 Watt with 20 Watt LED Tube, Wall or Ceiling mounted type with all Accessories, Pre-wired, fixing on and including providing PVC Box (2 No) and connecting up with and including Twisted Flexible Copper Conductor Cable of Size 40/0.0076 of suitable Length including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed. NOTE : Old Unserviceable Light Fitting 39 No. against Taking down of Point Wiring will be catered under Schedule of Credit.
S&F LED T-5 Tube Light Fitting 1x20 Watt, 4 Feet long with LED 20 Watt Integrated Batten and connecting up with and including suitable Size and Length Twisted Flexible Copper Conductor Cable including Taking down Unserviceable Light Fitting (17 No.) of any description, complete all as specified and as directed.
S&F LED Panel (2'x2') Light Fitting 30 Watt with High Brightness SMD LEDs as Light Source, Enviromentaly Friendly, New Generation, Ultra Modern, Recess/ Ceiling mounting with Electronic Driver 30 Watt, complete with all Accessories, Pre-wired and connecting up with suitable Size and Length Twisted Flexible Copper Conductor Cable, 3 Core including Taking down/ out Unserviceable Light Fitting (16 No.), complete all as specified and as directed.
Supply & Hanging BLDC Ceiling Fan 1200mm Sweep, 26 Watt with Squirrel Cage Induction Motor, having 3 Blades, Holding Down Rod and Accessories, 230 Volt, providing Electric Connection from Ceiling Rose to Ceiling Fan with and including Twisted Flexible Copper Conductor Cable of suitable Size and Length, 3 Core including Taking down Ceiling Fan of any Make and Sweep from any Height, Removing to AGE E/M Store and deposited, complete all as specified and as directed.
M&L Taking down Ceiling Fan, Exhaust Fan of any Make and Sweep from any Height after disconnecting Electric Connection and Keep in Safe Custody for Re-fixing / Re-hanging, complete all as specified and as directed.
M&L Transporting Ceiling Fan of any Make and Sweep from Site of Works to nearest Workshop, Opening Fan Cover for Taking out burnt Winding of any description, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (as per existing), Providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Repaired Fan to Site of Work after Rewinding, complete all as specified and as directed.
M&L Preparing Old Painted Surfaces of Ceiling Fan, Exhaust Fan of any Make and Sweep/ Size including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, complete all as specified and as directed.
M&L Re-hanging/Refixing only Ceiling Fan, Exhaust Fan (obtained from BOQ Item No. 2.026 here-in-before) and connecting with and including suitable Size Twisted Flexible Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed.
M&L Mild Steel Flat Iron 40x5mm in Fan Hook, Cut to Length, bent to Shape as ordered, drilling holes for Bolts including providing Mild Steel Bolts, Nuts and Washers, conforming to Fe-290 Gde-E-165 including Taking down Unserviceable Fan Hook (08 No.) of any description, complete all as specified and as as directed.
S&F MCB Single Pole 6 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed. NOTE : Old Unserviceable MCB 30 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F MCB Single Pole & Neutral 10 Amp to 32 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed. NOTE : Old Unserviceable MCB 02 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F MCB Single Pole & Neutral 40 Amp, 'C' Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed. NOTE : Old Unserviceable MCB 08 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F Sheet Metal Enclosure for DB's when MCBs to be used, 2-way, SPN, 240 Volt AC, Single Door, Epoxy Based Powder coated with 200 Amp Neutral Bar & Earth Bar and Connecting up, complete all as specified and as directed.
S&F Sheet Metal Enclosure for DB's when MCBs to be used, 4-way, SPN, 240 Volt AC, Single Door, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure for DBs of any description, complete all as specified and as directed. NOTE : Old Unserviceable Sheet Metal Enclosure for DB's 01 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F Sheet Metal Enclosure for DB's when MCBs to be used, 4-way, SPN, 240 Volt AC, Double Doors, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure for DBs of any description, complete all as specified and as directed. NOTE : Old Unserviceable Sheet Metal Enclosure for DB's 05 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F Sheet Metal Enclosure for DB's when MCBs to be used, 8-way, SPN, 240 Volt, Single Door, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure for DBs of any description, complete all as specified and as directed. NOTE : Old Unserviceable Sheet Metal Enclosure for DB's 02 No. obtained from Taking down/ out will be catered under Schedule of Credit.
S&F Sheet Metal Enclosure for DB's when MCBs to be used 8-way, SPN, 240 Volt, Double Doors, Epoxy Based Powder coated suitable for mounting MCB DP/ SPN as Incomer and MCB SP as Out-goings with 200 Amps rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Connecting up including Taking down Unserviceable Sheet Metal Enclosure for DBs of any description, complete all as specified and as directed. NOTE : Old Unserviceable Sheet Metal Enclosure for DB's 02 No. obtained from Taking down/ out will be catered under Schedule of Credit.
Supply and Laying or Fixing or Passing through Pipe, 1100 Volt grade Heavy duty Cable with PVC insulated Aluminium Stranded Conductor served with an Inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed 4.0 Sqmm Nominal Cross Section, 4 Core in Service Connection including Taking down Unserviceable Service Connection Cable of any description, complete all as specified and as directed. NOTE : Old Unserviceable Service Connection Cable 293.00 RM obtained from Taking down/ out will be catered under Schedule of Credit.
Supply and Laying or Fixing or Passing through Pipe, 1100 Volt grade Heavy duty Cable with PVC insulated Aluminium Stranded Conductor served with an Inner sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed 10 Sqmm Nominal Cross Section, 2 Core in Service Connection including Taking down Unserviceable Service Connection Cable of any description, complete all as specified and as directed. NOTE : Old Unserviceable Service Connection Cable 300.00 RM obtained from Taking down/ out will be catered under Schedule of Credit.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking down Unserviceable Earthing of any description (06 Set), complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for Taking out/ up and/or laying of Water Pipe Line, Cable Line, etc., Forming surfaces to required Foundation/ Gradient and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps with Surplus Soil along the Route of the Water Pipe Line, Cable Line, etc., in Soft/Loose Soil, complete all as specified and as directed.
Disconnecting & Taking down/out Unserviceable LT Cable of any size and any description including Cable Protection GI Pipes, Bricks, etc. from Trenches, Floors, Poles, Walls, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid separately under appropriate Items.
Supply & Laying LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998, Cross-sectional Area 35 Sqmm, 3½ Core, laid in Trenches, Ducts or through Pipes or fixing to Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Bricks, etc. will be Measured & Paid separately under appropriate Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks of Size 230x115x75mm, Kiln burnt, for Covering Protection to Under Ground Cable, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
M/s JK Jangid and Company
AFTAB ENTERPRISES
M/S Raju prasad
SHRI MANOJ KONWAR
M/S CHANDAN ENTERPRISE
M H KHAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .