Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹57.8 L+₹6.9 L (13.6%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹60.4 L+₹9.5 L (18.6%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹67.7 L+₹16.8 L (32.9%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹69.8 L+₹18.9 L (37.1%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Feb 2023, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2022_MES_562808_2
83608/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NASIK
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE NASIK ROAD CAMP
₹80,000
Yes
20 Mar 2023
14 Jan 2023
24 Feb 2023
14 Jan 2023
22 Feb 2023
15 Feb 2023
15 Jan 2023 - 25 Jan 2023
Amount
Material, Labour, Testing and commissioning in repairs of 11 KV Oil cooled breaker retrofitting fabrication modification and powder coating all as specified and directed by Engr in-Charge.
Material and labour in repairs breaker 11 KV main incomer all as specified and directed by Engr -in-Charge.
Material and labour in repairs Isolator for outgoing11 KV all as specified and directed by Engr -in-Charge.
Material and labour in repairs Main ring contact tank convert to SF6 Gas 11 KV all as specified and directed by Engr -in-Charge.
Material and labour in repairs Protection relay 3O/O+ 1 EF 11 KV all as specified and directed by Engr -in-Charge.
M&L in repairs 11 KV ABB classic VCB complete pole assembly all as specified and directed.
M&L for spring charging drum and spring for 11 KV Classic VCB all as specified and directed.
Labour for disconnecting carefully electrical connection from 33 KV HT sides of the potential transformer outdoor type of capacity 33 KV mounted on steel structure at 33 KV substation, keeping the disconnected connections at safe side and taking out the potential transformer having following details to carrying out which shall complete of the following ratio :- (i) Primary side (KV) = 33/1.732 (ii) Secondary side (V) = 110/1.732 complete all as per Engr-in-Charge.
Material, repair and labour for lifting , transporting handling the 33 KV potential transformer to workshop and opening top cover of the potential transformer by dismantling the slud, unscrewing nuts, bolts, washers etc including disconnecting core assy from HT bushing and lifting the same gently and taking out from the shell (container/body) of the potential transformer complete all as per directed by Engr-in-Charge.
Material, Repairs and labour for draining out burnt oil from the 33 KV potential transformer.
Material, repair and labour for cleaning of the 33 KV potential transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the potential transformer and drying/heating up the shell from inside before refilling the new transformer oil of ISI grade complete all as per directed by Engr-in-Charge.
Material, repair and labour for copper winding of coil with same gauge , same no of turns and same material with similar class of existing insulation as per manufacturers specifications and gently refixing the coil in body of 33 KV potential transformer /Current Transformer.
Material, supply and refilling oil of approved quality ISI marked for filling 33 KV potential transformer/Current Transformer.
Material, repair and labour for the top cover incl replacement of cork sheet,/gasket, tightening of nut bolt, washers etc for 33 KV potential transformer.
Supply and labour for new HT pocelain bushing with studs complete with oil seal, gaskets, ring washer at workshop for 33 KV potential transformer.
Repair and labour for Lifting/shifting to the place from where removed and re-installing the potential transformer including connecting HT/Earthing connecting including Testing and filling and commissioning of 33 KV PT etc.
Repair and Labour for disconnecting carefully electrical connection from 33 KV HT sides of the current transformer outdoor type of capacity 33 KV mounted on steel structure at 33 KV substation, keeping the disconnected connections at safe side and taking out the current transformer .
Labour for lifting , transporting handling the 33 KV Current transformer to workshop and opening top cover of the current transformer by dismantling the slud, unscrewing nuts, bolts, washers etc including disconnecting core assy from HT bushing and lifting the same gently and taking out from the shell (container/body) of the current transformer complete all as per directed by Engr-in-Charge.
Repairs and labour for draining out burnt oil from the 33 KV current transformer.
Repair and labour for cleaning of the 33 KV current transformer body from inside, removing deposited dirt/sludge/foreign particles etc from the bottom/body of the current transformer and drying/heating up the shell from inside before refilling the new transformer oil of ISI grade complete all as per directed by Engr-in-Charge.
Repair and labour for the top cover incl replacement of cork sheet,/gasket, tightening of nut bolt, washers etc for 33 KV current transformer.
Supply and labour for new HT porcelain bushing with studs complete with oil seal, gaskets, ring washer at workshop for 33 KV Current transformer.
Repair and labour for Lifting/shifting to the place from where removed and re-installing the current transformer including connecting HT/Earthing connecting including Testing and filling and commissioning of 33 KV CT etc.
M&L for Testing and commissioning of Current Transformer & calebration of 33 KV HT control Relay Panel for over current & Earth fault protection by primary & secondary ejection methods & submitting test report duly signed by Engr-in-Charge.
M&L for disconnecting carefully electrical connection from 11 KV HT sides of the CURRENT transformer indoor type of capacity 11 KV mounted on VCB at 33 KV sub stn AOP feeder , keeping the disconnected connections at safe side & supply and fix in repairs 11KV Indoor Current Transformer oil immersed type Epoxy Resin Cast having following specification :- (a) 2705/BS 3938, ratio : 50/5/5 Amp, S.T.C : 18.4 kA for 0.5 Sec burden class core 1-15 VA /1.0 class , core 2-15 VA/5P10, HSV-12 KV as per IE Rules. (b) Frequency 50 Hz Make : Crompton Greaves/Equivalen
M&L for Testing and commissioning of Current Transformer & calebration of 11 KV HT control Relay Panel for over current & Earth fault protection by primary & secondary ejection methods & submitting test report duly signed by Engr-in-Charge as specified and directed.
M&L for Heat shrinkable 33 KV (E) XLPE Indoor termination ( 3 core ) , HT underground cable of size 3 core 240 sqmm, 33000 volts all as specified and directed by Engineer-in-Charge.
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,400 Amps incl dismantling of old one all as specified.
Dehydration of tranformer oil, obtained from transformers/voltage stabilizer/OCBs etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine and topping up/ replacement of unserviceable transformer oil complete all as directed. Note :- Filteration of transformer oil shall be off loaded position of transformer.
Supply & filling transformer oil of approved quality ISI marked for filling in transformer for topping up/ replacement in transformer complete all as directed by Engr-in-Charge( MAKE: POWER/CASTROL/SERVO) NOTE: I) DIELECTRIC STRENGTH OF TRANSFORMER OIL NOT LESS THAN 60 KV WITH 2.5MM GAP. II) NEW TRANSFORMER OIL FILLED TO TRANSFORMER AFTER FILTRATION ONLY, RATE FOR FILTRATION DEEMED INCLUDE IN THE QUOTED RATE.III) OIL SUPPLY TO THE DEPTT FOR FILLING IN A SEALED BARREL ONLY.
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
Dismantling of U/S insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Re-fixing of old HT disc insulator obtained from item No. 48 above.
Re-fixing of old HT Pin insulator obtained from item No. 48 above.
S&F loop type insulator , vitreous porcelain , 140mm clearance of hole 25.5 mm , white, brown or green all as specified and directed by engineer-in-Charge.
S & F HT disc insulator porcelain vitreous 150mm height, 150mm dia, ball and socket type. White / brown with M.S. galvanized iron fitting suitable for working pressure 11KV all as specified and directed by Engr-in-Charge.
Dismantling of U/S stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
Stay assembly complete with accessories and stay rod 16mm dia and 180 cm long, including ms galvanized stay plate 300 mm x300 mmx6mm and galvanized thimble complete all as specified and shown in electrical plate No 1 Note-(loop type insulator, stays clamps, excavation and earth work and concrete measured separately)
All as per Item No 38 but stay rod 20 mm dia
Dismantling carefully the existing U/S LT/HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Supply and stringing ACSR conductor for over head line securing on pole complete including binding wire ,jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed.
Stringing only old dismantled ACSR conductor for over head line securing on pole complete including binding wire , etc of any size all as specified and as directed.
Taking down old jumper connection of 4 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkathene/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of 2 pole structure from line/AB/DO & re-fixing complete with new conductor , including line tap, lugs, & PVC alkathene/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Taking down old jumper connection of disc cut point from line and re-fixing complete with new conductor , including line tap, lugs, & PVC alkathene/pipe sleeve all as specified and directed by engr-in-Charge. ( ACSR conductor will be measure & paid separately )
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved aluminium bus bar of rating 450 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with
(Item No 46 Contd/..)PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs cable gland and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:- (A) Incoming:- (a) Copper bus bar TPN 450 Amps - 01 Set (i) Danger notice plate/ sticker of suitable size on front panel board -01 No (ii) MCCB 4 pole 250 A 36 kA- 01 No (B) Outgoing:- (i) MCCB TPN 100 Amps 04No (ii) MCCB TP 63 Amps 02 No (iii) MCB SPN 63 Amps 01 Nos (iv) Digital timer with contactor (v) Each outgoing Feeder Name Radium Sticker Inside Panel. (vi) voltmeter, Ammeter and selecor switch (vii) Phase indication lamp R, Y, B LED type
Dismantling of U/S existing cross arms by means made from channels, angles, U/S GI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessary calmp nut bolt etc complete all as specified and directed Make - TATA / JINDAL /SWASTIK
Taking down of faulty LT underground cable of size upto 3.5 x 25 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Taking down of faulty LT underground cable of size above 3.5 x 25 sqmm upto 150 sqmm from trenches/pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete : Note : Excavation/Earth work and cable jointing & jointing kit shall be measured and paid for separately under relevant item of schedule .
Supply and joint cable jointing kit straight through joint epoxy type of size 10 sqmm 4 core to 16 sqmm 4 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 70/95 sqmm 3.5 all as specified and directed. Make : Denson, Raycom
Supply and joint cable jointing kit straight through joint epoxy type of size 120 sqmm 3.5 to 150 sqmm 3.5 core all as specified and directed. Make : Denson, Raycom
Dismantling of existing U/S LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demoltion of concrete, disconnection of conductor fom pole etc. complete all as directed.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 9 mtr long 410 SP-31 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, with inbuilt junction box for 3 phase 4 wire AC supply and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450mm x 450mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-55 including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Taking down unservisable U/G cable,service wire from trenches, wall, floor etc upto 50 sqmm
Taking down unservisable U/G cable from trenches, wall, floor etc above 50 upto 120 sqmm
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable size of following sizes aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete Note- Rate is inclusive of cable gland & cable lugs
(i) 2 core 10 sqmm
(ii) 4 core 16 sqmm
(iii) 3.5 core 25 sqmm
(iv) 3.5 core 35 sqmm
(v) 3.5 core 50 sqmm
(vi) 3.5 core 95 sqmm
(vii) 3.5 core 120 sqmm
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 95 sqmm complete all as specified and directed.
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out.
Material and labour for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and internal dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 Sqmm
M&L for Double Walled Corrugated DWC (HDPE) pipe of outer dia 90mm and inner dia 78mm including 90 degree bends with coupler and rubber ring laid in trenches of size 90mm suitable for cable protection of size 3.5 core 95 sqmm to 120 sqmm cable complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole as specified by Engr-in-charge.
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2020) and testing on completion.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-2020 (part-I)
S & F MCCB 4 pole in LT Panel thermal magnetic setting of current amp 400A , breaking capacity 25kA, of complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB 4 pole in LT Panel thermal magnetic setting of current amp 250 A , breaking capacity 25kA, of complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB TPN in LT Panel thermal magnetic setting of current amp 160A , breaking capacity 25kA, of complete with lugs ,spreader link, gland to cable complete all as specified and directed.
S & F MCCB TP in LT Panel thermal magnetic setting of current amp 125A , breaking capacity 16kA, of complete with lugs ,spreader link, gland to cable complete all as specified and directed by Engr-In-Charge.
S & F MCCB TP in LT Panel thermal magnetic setting of current amp 100A , breaking capacity 16kA, of complete with lugs ,spreader link, gland to cable complete all as specified and directed directed by Engr-In-Charge.
Supply, Installation, Testing and commissioning of 11 KV PC VCB 1250 Amp Breaker pole assembly suitable for ABB Make 1250 Amps HT Breaker incl testing by artificial 11 KV load complete . Note : Contractor should submit test certificate before completion )
S&F in repair, lightening arrestor, non-linear metal oxide type, complete with and including all fittings, transmission class, discharge capacity 65 KA suitable for 33 KV, out door type and also including necessary connection and and fittings all as per IS-3070 Part-III and IEC 1994. complete all as specified and as directed.
Supply and lay hardcore of gauge n.exc 63mm, depositing spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface all as specified and directed by Engr-in-Charge.
M&L for carrying out the periodical check and preventive maitenance as detailed below (interval between each of the periodic check and preventive maitenance, shall not exceed 03 months) for the entire system comprising of the existing HT VCB/SF-6 breaker, 33 KV, 800/1600 Amps, 25 kA with VCB/SF-6 panel etc. ABB Make and connected HT 33 KV Contralling relay panel at 33 KV receiving station complete all as specified and as directed:-
Servicing (i.e. light primary terminals) & carrying out repair/replacement (as directed) of defective components.
Function check.
Mechanisum servicing and lubrication.
Gas leak check.
Protection check.
Control wiring tightness.
Power connection tightness.
Insulation measurement of main circuit.
Contact resistance of main circuit.
Check oil leak of absorber.
Checking the operation of VCB/SF6 breaker.
Overhauling and Caliberation of O/C & E/F relays, Aux relay (through primary injection/secondary injection), testing on each multiple setting of relay.
Checking and recording of IR value of breaker trolly.
Checking/repairing/rectification of control wiring.
Cheking & repairing/replacement (as directed) of the panel heater & space heater.
Replacement of the unserviceable open circuit of CT's.
Testing CT & PT and their circuit.
Cleaning the breaker externally and internally thoroughly with lint free cloth, complete all as specified and as directed.
High voltage testing with high voltage tester of CT & breaker pole to withstand working pressure HT 33 KV to acertain srviceability, spare parts found defective to be replaced for smooth functioning as directed.
The servicing, overhauling and testing of 33 KV outdoor SF 6/VCB panel(including breakers) shall be got done by the contractor from the authorised agency/Rep of OEM (ABB) or SEB as approved by GE.
NOTE:- (i) The periodicity of carrying out the periodic check & preventive maintenance as per thr scope including in the above item shall be 03 months. Unit of the payment for carrying out each of the periodic check & maintenance of interval of 03 months shall be considered as 'Each'. Further in case the periodic check & preventive maintenance is required to be carried out, at a interval of less than 03 months, due to development of any defect or due to any reasons, whatsoever may be, as per the direction of the GE, the same shall also be carried out by the contractor, for which, No payment shall be admissible and the cost thereof, shall be deemed to be included in the quoted rate of above item.
(ii) After carrying out each of the periodical check and maintenace, the contractor shall submit the Serviceability and Recommendation Certificate from the Rep/Agency of OEM(ABB) or SEB as approved by GE.
(iii) Immediately after isuue work order, the periodic check & Preventive Maintenance included in above item & its connected items, shall be commenced by the contractor, simultaniously to the other repair/works as directed by Engr-in-Charge
M&L for Servicing /Repair to HT Pannel of having vaccum circuit breaker 33 KV rating of capacity current rating upto 800 Amps to 1600 Amps of any make & type, servicing of VCB by cleaning contacts moving parts removing dust particles from spout gear mechanisum and moving parts repairs to motor, change spring mechanisum tightening of nuts & bolts of entire trolly components all as directed inserting in trolly, testing, commissioning putting on the supply on load complete all as specified and directed and scope of work incudes following :- (a) Inspection and cleaning breaker mechnisum assembly & check proper operation and repair work.. (b) Servicing & overhauling for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, readjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB. (e) Racking-Rack out operation in test and service position of VCB trolly
(Item No 84 Contd/...) (f) Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test(Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds). (j) Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (k) Checking and lubrication of various interlocks. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. (m) After servicing test report shall be furnished in standard format approved by E-in-C. Note :- (i) The cost of minor parts ie nuts ,bolts,spring washers,dust cover ring of isolarors contacts,clips pins for release prop,Y phase shrouded over side stop pin,and all other minor parts ie packing essentially required to make the panel dust proof shall be deemed to be included in the rate quoted by the contractor . (ii) The servicing will be carried as per norms of OEM. (iii) The periodicity for carrying out the preventive maintenance as per the scope included in the above item shall be Three Months. Unit of the payment for carrying out each of the periodic check and maintenance at interval of Three Months shall be consider as each.
M&L for attending emergency breakdown for 33 KV VCB of any capacity as and when ordered by Engr-in-Charge, including servicing, adjusting & fault finding & rectifying the fault by skilled Engr & testing the unit complete & submitting test report all as specified and as directed. (a) Inspection and cleaning breaker mechanism assembly & check proper operation and repair work.. (b) Servicing & overhauling for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, re-adjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB. (e)Racking-Rack out operation in test and service position of VCB trolly (f) Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test(Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds).
(Item No 85 Contd/....) (j) Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (k) Checking and lubrication of various interlocks. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. (m) After servicing test report shall be furnished in standard format approved by E-in-C.
M&L for taking out VCB bus bar of capacty 800 to 2000 Amps from up to 33 KV VCB bus bar compatrment and cleaning the bus bar with CTC liquid replacement of HT sleeves of suitable sizes of Make-Raychem BPTM 120x50, 295342/18:49 upto 50 KV , HT insulation Tape for CT/PT connection, Re-fixing of bus bar by means of nuts, bolts & washers of suitable size including painting of bus bar combartment internally with insulation paint for removing moisture from VCB as specified and directed
M&L for carrying out high voltage test for 33 KV VCB, CT, CT Bus Bar, PT, PT Bus Bar, Bus Bar Duct, Spout & Insulators, Main Chember etc, upto 45 KV all as specified and as directed.
Supply only following spare parts of the Out Door type 33 KV VCB of Make-ABB all as specified and directed:-
Closing Coil 110 V AC/DC for 33 KV VCB
Tripping Coil Assembly for 33 KV VCB
Trip Catch Assembly for 33 KV VCB
Bus Bar supporting Spout for 33 KV VCB bus bar
Spring Charging Motor for 33 KV VCB (110 V DC/230 V AC)
TNC Switch for 33 KV VCB
IDMT Relay for 33 KV VCB (Over current+earth fault Relay with minimum setting of current and timing inrush setting, over current, high set, earth fault, TCH, fault record, storage, for Simens/ABB make VCB, CT-115A, Aux Voltage 24-230 Volt AC/DC)
Space Heater 200/230 Volt AC
Thermostat 0-100 Degree Centigrade
Tulip Contact
S&F in repair of fuse indoor type, 33 KV, Type PTAVT, Amps 3.15, 50 Hz incl removing un- serviceable PT
Ammeter digital type
Voltmeter Digital Type
M&L for cleaning of all HT VCB up to 33KV capacity panels externally and carried out painting with super enmelled paint all as specified and as directed.
Supply and filling transformer oil suitable for 33 KV grade with correct grading with demoisturising and removing the impurities if any from the fresh oil and oil demoiturising in plant under specific vaccum and refilling through conservation tank upto the specified level and to maint dielectric strength of oil upto 60 KV all as specified and as directed.
Taking down old jumper connection of 33 KV yard pole structure from line/AB/DO & refixing complete with new conductor, including line tap, lugs & PVC alkdin/pipe sleeve etc. complete all as specified and as directed.
Removing all connections of Earthing in 33 KV Yard from test point, replacement of all rusted nuts & bolts with washers, test point from equipment, checking result of earthing with earth test equipment and preparing records all necessary required at site as specified and as directed by Engr-in-Charge.
M & L for scraping all earth chambers in 33 KV yard areas, repainting of earth chembers with cement/oil paint, marking of earth chambers name with appropriate paint all as directed by Engr-in-Charge,
S&F in replacement of seal maitenance free battery for battery bank 30 Volts, 100 AH, making Connection with and including suitable size of cable or bus bar, Battery charger for battery bank incuding installation/testing complete all as specified and directed. Make : EXCIDE/AMAR RAJA/TECSON/ PANVA
M&L for cleaning of all 33 KV yard area, removing all Grasses, Bushes, Soil and waste material and thrown away from site, levelling all 33 KV yard area, Spraying of anti fungus/grass chemical in all areas before laying of old aggregate and after laying of new aggregate in all 33 KV Yard area all as specifie and directed
M&L for painting of 33 KV, 3.15 MVA Transformer, out door type, OLTC, Radiators with smoke gray synthetic enamel paint with two coats after cleaning & removing dust & dirt and cleaning with sand paper complete including writing of SM/MES number on transformer body with the letters 100 mm height with white synthetic enamel paint all as specified and directed.
M&L for painting of 33 KV yard Steel structure complete with smoke gray synthetic enamel paint with two coats after cleaning & removing dust & dirt and cleaning with sand paper complete all as specified and directed.
Fabricating, supply and fixing MES installation Glow sign board fabricated out of two side polycarbonate unbreakable sheet LG vinyl cutting duly framed with 18 SWG GI sheet and suitable angle iron frame of not less than 35x35x5 mm errected at a height of 1.5 mtr from ground level duly embedded in PCC. The sign Board to be written in bold letters of standard size as per sample, duly fitted with 2x10 watt LED tube light fitings with prewired and connectd to the street light feeder through one three core PVC insulated copper conductor 1.5 sq mm drawn through MS conduit of adequate size to avoid mechanical damage on ground and raising on sign board or street light pole or bldg for MES ELECTRIC INSTALLATIONS complete all as specified and directed.
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed by Engr in Charge.
M&L for angle iron posts for chain link fencing, with holes drilled and grouting in the foundation concrete all as directed (Fe 410W) Quality A complete all as specified and directed by Engr in Charge. Note : Concrete for foundatin measured seperately under relevant item.
Taking down unservisable U/G cable, service wire from trenches, wall, floor etc upto 50 sqmm
Taking down unservisable U/G cable from trenches, wall, floor etc above 50 upto 120 sqmm
Supply and fix in repairs 45 watt Invertor LED Street light with PDC housing, IP 66 and inbuilt battery backup with auto ON/OFF and dimming option all as specified and directed by Engr-in-Charge.Make : Halonix cat part No LED SL HLSLD-ML04-45CWL-INV-DIMM-RTC-R or equivalant to Crompton/Havells
S&F in repairs metal box MS enclosure made out of CRCA sheet 3.00mm thick of size 450mm x 450mm x 250mm depth with three phase aluminium bus bar and fixing 3P 100A MCCB mounted on epoxy insulators, fixing arrangement with suitable MS Clamps all as specified and directed.
SHRI SWAPNAYOG ENTERPRISES
DURGAI ELECTRICALS
M/S Kumar Contractors
P C DAVE AND SONS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .