| 1 | L1₹26.5 LAccepted-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-Finance Lowest and reasonable bid | |
| 2 | L2₹28.5 L+₹1.9 L (7.23%)Rejected-Finance BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹31.5 L+₹5.0 L (18.9%)Rejected-Finance SHOP NO 4 GULATI MARKET KRISHNA NAGAR NEHRU GARDEN ROAD JALANDHAR PUNJAB 144001 | JALANDHAR | PUNJAB | 144001 | L3 | Rejected-Finance Other than the lowest bid | |
| 4 | L4₹31.7 L+₹5.2 L (19.5%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L4 | Rejected-Finance Other than the lowest bid | |
| 5 | L5₹32.6 L+₹6.1 L (22.9%)Rejected-Finance | L5 | Rejected-Finance Other than the lowest bid |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
7 Dec 2024, 6:00 pmClosed
GE (WEST) JALANDHAR CANTT
KABIR ROAD JALANDHAR CANTT
DAY TO DAY MAINT OF INTERNAL ELECTRIFICATION OF OTM IN ZONE-II UNDER GE (WEST) JRC
2024_MES_683315_1
GE/JAL(W)-69/2024-25
Open Tender
Civil Works
Item Rate
180 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST)
₹88,000
Yes
28 Jun 2025
11 Nov 2024
14 Dec 2024
11 Nov 2024
7 Dec 2024
25 Nov 2024
Amount
Attending of complaints from 0800 hrs to 1800 hrs by deploying electrician along with helpers for checking of existing electrical items including carried otr minor repair such as changing of fuse, starter, rod, small pieces of wire etc carrying out repairs such as tighining of lose electric connections, nuts, bolts, screws, switches, sockets, switch boards ceiling fans/exhaust fan etc as required to make the item functional and to ensure contiunous electric supply complete as specified and directed. Note: (a) Replacement of electric fitting shall mesured and paid for seperately under respective items (b) Rate quoted deemed to be inclusive of T&P etc. (c) The saftey and insurance of persons/helper engaged in Execution shall be responsibility of contractor. (d) As the Nos of complaints shall be on required basis the financial effect to this is deemed to be included in the rate quoted. (e) Penalty Rs 50/- per complaint per day be charged if complaint not rectified within 24 hours
M&L for point wiring in repair with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. a) One light / fan / call bell point controlled by one, one way switch.
b) Do all as per Ser item No 2.00 above but for 5 amps socket on independent board
c) Do all as per Ser item No 2.00 above but for 5 amps socket on same board
Do all as per ser item No 2.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into existing PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. (a) One light / fan / call bell point controlled by one, one way switch.
(b)Do all as per Ser item No 6.00 above but for 5 amps socket on independent board
(c)Do all as per Ser item No 6.00 above but for 5 amps socket on same board
Do all as per ser item No 6.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply & fixing in repair switch piano flush button type single pole one way 5 Amps all as specified. Make: SSK/Havells/Cona.
All as item 10.00 here-in-before but single pole 5 Amps two way all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair bell push single pole 5 Amps all as specified.Make: SSK/Havells/Cona.
Supply & fixing in repair switch piano flush button type single pole 15 Amps.Make: SSK/Havells/Cona.
Supply & fixing in repair socket outlet 5 Amp flush button type all as specified.Make: SSK/Havells/Cona.
All as per item 14.00 here-in-before but 6 pin 5/15 Amps multi type.Make: SSK/Havells/Cona.
Supply & fixing in repair ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified. Make: Anchor/SSK
Supply & fixing in repair lamp holder PVC, insulated body with back plate suitable for batten fittings along with 9 watt LED lamp all as specified.Make: Anchor/SSK
Supply & fixing in repair light fittings decorative LED lunminare for wall mounting multi colour ABS housing with ploycrabonate rings thermo set plastic/glass lamp holder CITY 1 fitting for lamp 1X Eco tone Crystal/ Décor Model No HLDL03160099 along with 15 watt retro fit CFL/LED Spiral along with lamp complete all as specified and as directed.Make Havells
Supply & fixing in repair regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : USHA/Orient/ Polar .
Supply & fixing in repair bell electric (dingdong) 230 volt, SP complete all as specified and as directed. Make : Anchor .
Supply & fixing in repair Buzzer, AC, 230 Volts, single pole complete all as specified and as directed. Make : Anchor
S & F MCB SPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type conforming to Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. Make : EKINOX3 series of Legrand/Acti 9 metalic series of Schneider /Osafe series of HPL/Metallica of Havells/Hager/L&T/Siemens
Supply and fix MCB DB, TPN 6 way double door Vertical type suitable for mounting of MCCB as incomer with suitable 200 amps rated bus bars , Neutral links , blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
Supply and fix MCCB 100 Amps 4 pole 415 Volt,25 KA breaking capacity conforming to Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed .
Supply & fixing in repair MCCB 3 pole of capacity 63 Amps with breaking capacity 16KA including all electrical connections and fixing arrangment all as specified and directed by Engineer -in-Charge (Make : Siemens/Legrand/L&T/BCH)
Supply and fix MCB DB, TPN 4 way double door with suitable 200 amps rated bus bars , Neutral links , blanking plates conforming to Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed. all as specified and directed.
S/F MCB TPN 40 Amps 415 volts as per Osafe of HPL / Acti 9 series of Schneider /equivalent in Havells/Hager/L&T/Siemens complete all as specified and directed.
Supply and fix of Microwave Sensor enabled Integral LED 4 ft luminaire with extruded housing and Opal diffuser ith ABS end caps. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of at least 100 lumen/watt with a maximum system wattage of 20 Watts. Fixture should cover upto 5 mtr sensor radius coverage area with 120 degree angle after 17 to 30 seconds & 30% light output in case of non-occupancy.The electronic driver used shall have a power factor >0.9 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters complete all as specified and directed .. Havells Cat no LUMILINESMART20WLED865PCWH equivalent in Signify/Wipro
S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed.. Havells Cat no ENDURASUNBEAMSL45WLED757SASYTOPCSENSO equivalent in Signify/Wipro
S & F in repair surface mounted LED Battern with LED tube rod 2 Feet 10W internal surge protection device of 4 KV with voltage band 140-280V and making electrical connection to ceiling rose all as directed Make Havells, Bajaj, C & S
S&F new generation energy saving 60 Watt LED flood light, powder coated PDC aluminum body with toughened glass visor.Efficacy>100 Lm/w. Available 5700K IP66. Also available in 3000K & 4000K on demand. Cat Part No:- PAR0206012. Make:- Polycab/Havells/CG or equivalent
S & F LED bulb 12 Watt White(6000K-6500 K)/Warm(2700K-3200K) with BEE Energy star rating of three star or more and emission of minimum 100 lm/W complete all as specified
S& F in replacement LED tube set Fitting 20 W Use & Throw type with internal surge protection device of 4 KV with voltage band 140-280V and making electrical connection to ceiling rose all as directed Make Havells, Bajaj, C & S
Supply and fix of hexagon shaped LED bulkhead industrial luminaire with Pressure die cast housing and Polycarbonate diffuser and silicon gasket. The luminaire should have a color CRI > 80, and CCT of 5700K. The luminaire shall be compliant with IP66 & IK 10 classification. Luminaire shall be designed to emit at least 1000 nominal lumens at a system efficacy of at least 100 lumen/watt with a maximum system wattage of 10 Watts. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 180-270V AC and 4 Kv inbuilt surge protection. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Havells Cat no HEXAFT10WLED857SSYMBOPC equivalent in Signify/Wipro
Supply and fixing of new generation, post top, energy saving spun aluminium landscape luminaries with high power 40W suitable for Pole dia 76mm confirming to IP65 Ruby (Clear) Of Havells cat part LHEVBGP7PN6K040. Make Havells
Supply and fix of Recess LED 2x2 PIR based luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have a color consistency SDCM < 5, CRI > 80 and CCT of both 5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 4250 nominal lumens and an outstanding System efficacy of atleast 115 lumen/watt and maximum system wattage of 36 Watts. In up position sensor will work with detection range of 3m & in down position sensor will work with detection range of 6m. Time delay options should be 5s, 30s, 1min, 5min, 8min.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <10% with 3 KV internal surge protection and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters complete all as specified and directed . Havells Cat no VENUSNEOHE2X2R36WLED857PIRSENSOR equivalent in Signify/Wipro.
S & F in repair 36 Watt 2 x 2 LED PLUTO NEO Ceiling white colour light fitting utra modern designed, LED luminaire which provides soft-light and glare free symmetrical illumination suitable for armstrong/Grid Celing, including Bracket nuts, bolts washer as required for fixing. Cat Part No PLUTONEO2X2PLR34WLED840S Make Havells or /Philip or Bajaj equivalent
S & F in repair 36 Watt 2 x 2 LED PLUTO NEO Ceiling fitting warm yellow light fitting utra modern designed, LED luminaire which provides soft-light and glare free symmetrical illumination suitable for armstrong/Grid Celing, including Bracket nuts, bolts washer as required for fixing. Cat Part No PLUTONEO2X2PLR34WLED840S Make Havells or /Philip or Bajaj equivalent
M&L for submain wiring with two RUNS of single core 6 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
M&L for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 1.5 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed cables drawn through and including concealed in wall and necessary cutting and chasing rigid PVC conduit ISI marked not less than 20 mm dia and all accessories complete all as specified & directed.
Supply & fixing Modular switch piano flush button type single pole one way 5 Amps all as specified. Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular switch piano flush buttone but single pole 6 Amps two way all as specified.Make: SSK/Havells/Cona.
Supply & fixing Modular bell push single pole 6 Amps all as specified.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular switch piano flush button type single pole 16 Amps.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular multi socket 3 pin and 2 pin 6 Amp flush button type all as specified.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular socket outlet 6 pin 6/16 Amps multi type with shutter.Make: SSK/Havells/Cona. As per sample
Supply & fixing Modular regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts Make : USHA/Orient/ Polar/ As per sample
B.P CONSTRUCTION CO (BID ID -3177851)
FRIENDS ENGINEERS (BID ID -3178819)
UNITED ENGINEERING CORPORATION (BID ID -3183568)
B D BATRA AND SONS (BID ID -3183394)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .