Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | Lowest₹2.0 CrRejected-Finance AT P O RAKHA COPPER PROJECT DIST EAST SINGHBHUM JHARKHAND 832106 | RAKHA COPPER PROJECT | EAST SINGHBHUM | JHARKHAND | 832106 | Lowest | Rejected-Finance unreasonable and unjustified |
| Sl No | Description | Qty | Unit | JANTA ENGINEERING WORKS L1 |
|---|---|---|---|---|
| 1.00 | Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class "B" primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting. etc. complete. | - | - | - |
| 1.10 | Up to 1.5m height | 522.8 | Sq. M | 650 ₹3,39,817.4 Lowest |
| 1.20 | Beyond 1.5m height | 24,023.87 | Sq. M | 700 ₹1,68,16,706.9 Lowest |
| 2.00Painting of structural components of Hoist including supporting structures and surfaces of hydraulic hoist sun exposed to water as per IS:14177, for which surface preparation by blast cleaning of class 'B', primer coat (two coats) of zinc phosphate primer to give dry film thickness of 40±5 microns per coat and finish coat (one coat) of alkyd based micaceous iron oxide paint give dry film thickness of 65±5 microns followed by two coats of synthetic enamel paint, using airless spray, to give dry film thickness of 25±5 microns per coat, at an interval of 24 Hours. Thus total dry film thickness of all the coats, including primer coating, should not be less than 175 microns. This will include expenses on mobilization and demobilisation of equipment's. For maintenace painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris sand / blast cleaned as laid down in Para 7.0 of IS Code 14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete. | ||||
| 2.10 | Up to 1.5m height | 1,047.02 | Sq. M | 700 ₹7,32,913.3 Lowest |
| 2.20 | Beyond 1.5m height | 2,865.22 | Sq. M | 550 ₹15,75,869.35 Lowest |
| 3.00Painting of lifting beam / lifting tackles are per IS : 14177, for which surface preparation by blast cleaning, as per class "C" or class "B", primer coat (two coats) of zinc Phosphate primer, to provide dry film thickness of 40 microns per coat and finish coat (two coats) of alkyd based micaceous iron oxide paint, using airless spray, to provide minimum dry film thickness of 65± 5 microns per coat, at an interval of 24 hours. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 200 microns. This will include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete. | ||||
| 3.10 | Up to 1.5m height | 257.74 | Sq. M | 650 ₹1,67,531 Lowest |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
22 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM C and P division
Omkareshwar Power Station, Administrative Block, URJA VIHAR, Siddhwarkut Distt. Khandwa
Painting of Radial gates, Intake Gates, Intake Bulkhead Gates, Gantry Cranes, TRCM and Intake Gate Cylinders along with its Accessories at Omkareshwar Power Station
2025_NHDC_887615_1
NHDC/3/C/351/NIT-779/25/1144 dated 28.11.2025
Open Tender
Paint / Enamel Works
Works
370 days
Omkareshwar Power Station NHDC Ltd Siddhwarkut
Please refer Tender documents.
14 documents required · 14 mandatory
₹1,180
NHDC LIMITED
₹3.1 L
Yes
15 Apr 2026
29 Nov 2025
26 Dec 2025
29 Nov 2025
22 Dec 2025
29 Nov 2025
29 Nov 2025 - 15 Dec 2025
Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class "B" primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will be include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting. etc. complete.
Up to 1.5m height
Beyond 1.5m height
Painting of structural components of Hoist including supporting structures and surfaces of hydraulic hoist sun exposed to water as per IS:14177, for which surface preparation by blast cleaning of class 'B', primer coat (two coats) of zinc phosphate primer to give dry film thickness of 40±5 microns per coat and finish coat (one coat) of alkyd based micaceous iron oxide paint give dry film thickness of 65±5 microns followed by two coats of synthetic enamel paint, using airless spray, to give dry film thickness of 25±5 microns per coat, at an interval of 24 Hours. Thus total dry film thickness of all the coats, including primer coating, should not be less than 175 microns. This will include expenses on mobilization and demobilisation of equipment's. For maintenace painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris sand / blast cleaned as laid down in Para 7.0 of IS Code 14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
Up to 1.5m height
Beyond 1.5m height
Painting of lifting beam / lifting tackles are per IS : 14177, for which surface preparation by blast cleaning, as per class "C" or class "B", primer coat (two coats) of zinc Phosphate primer, to provide dry film thickness of 40 microns per coat and finish coat (two coats) of alkyd based micaceous iron oxide paint, using airless spray, to provide minimum dry film thickness of 65± 5 microns per coat, at an interval of 24 hours. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 200 microns. This will include expenses on mobilisation and demobilisation of equipment’s. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete.
Up to 1.5m height
stage.html
html • 0.04 MB
technical_933090.pdf
techsummary_933090.pdf
finance_933090.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
cancelled_1.pdf
pdf • 0.76 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.42 MB
tender351.pdf
Tender Documents • 30.75 MB
BOQ_933090.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .