Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 24 FLOWER STREET FLOWER STREET SAIDAPET CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | Rejected-Technical not submitted the Hard copy of Tender cost and EMD |
Tender Value
₹3.1 L
EMD Value
₹6,284
Closing Date
15 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(E)
EE(E),EC-II, Kellys
EI rearrangement for office shifting at KK Nagar
2025_BSNL_229363_1
NIT No 23/EE-T/EC-II/CH/2024-25
Open Tender
Electrical Works
Works
20 days
KK Nagar Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL, Chennai Telephones
₹6,284
2 Apr 2025
10 Mar 2025
17 Mar 2025
10 Mar 2025
15 Mar 2025
10 Mar 2025
10 Mar 2025 - 15 Mar 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
200 mm X 150 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
Supply and fixing 4' 18W LED batten light with polycarbonate built, on surface of wall i/c pdg necessary supports and interconnections etc as reqd.
Supplying and fixing of 56" energy efficient 5 star rated highspeed BLDC type ceiling fan with remote in the existing hook etc. as reqd.
Supply and drawing CAT 6 type network cabling in the existing conduit ets reqd.
Supply and fixing RJ 45 socket on surface i/c pdg necessary supports and interconnections etc as reqd.
Supplying and fixing of one number PVC insulated and PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of following size on wall surface as required.
3 1/2 x 25sqmm Al UG armoured cable
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Installaltion, testing, and commissioning of 1.5TR split type AC unit i/c laying the refrigerant piping and necessary wiring etc as reqd.
Providing and fixing Readymade MS condenser stand for fixing outdoor units of 1.5TR S/T A/C i/c providing necessary supports and grouting etc complete as required.
Suppling and laying of copper refrigerant pipe (5/8 " & 1/4 ") suitable for 1.5 TR split type A/C units covered with foam insulation i/c providing 3 core 2.5 sq mm flexible copper cable, i/c pdg necessary supports and interconnections etc as required
Wiring for circuit/ submain wiring alongwith earth wire with the varied sizes of recovered FR PVC insulated copper conductor, single core cable in the existing surface/ recessed medium class PVC conduit as required
Supply and fixing Alloy Steel D-Hook Set consists of 1 piece of D-Hook & 2 Pcs. of heavy duty Fasteners (M10x75mm) designed to hang Ceiling Fan, with load capacity of 75Kg on surface of the ceiling i/c grouting, filling etc as reqd.
SSK ELECTRICALS (BID ID -828828)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .