| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.4 L+₹39,195 (1.78%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹22.6 L+₹64,010 (2.91%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹24.3 L+₹2.3 L (10.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹25.8 L+₹3.8 L (17.5%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹28.2 L
EMD Value
₹56,380
Closing Date
13 Mar 2020, 6:00 pmClosed
GE South Pathankot
GE South Pathankot
Repair/maint of perimeter lights, street lights etc including control panel, improvement to E/M installation, summer cooling appliances, water heaters and UPS/Stabilizer at Dhangu, Nangal and Mirthal area under GE (S) Pathankot
2020_MES_318416_2
GES/PKT/T-57/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dhangu, Nangal, Mirthal
Refer tender documents and NIT
9 documents required · 9 mandatory
₹500
GE South Pathankot
₹56,380
Yes
9 May 2020
25 Feb 2020
14 Mar 2020
25 Feb 2020
13 Mar 2020
28 Feb 2020
25 Feb 2020 - 27 Feb 2020
Amount
M&L for carrying out servicing & maintenance of UPS of capacity 20 KVA of any make by strip opening of UPS, inspection/ servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.
M&L for carrying out servicing & maintenance of UPS of capacity 15 KVA of any make by strip opening of UPS, inspection/ servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.
Supply only the following spares for carrying out repairs to UPS of capacity 15/20 KVA under item No.1 & 2 above :-
a) Inverter card
b) Rectifier Card
c) AC capacitor
d) DC capacitor
e) 12 V 42 AH SMF batteries
Supply & fixing in replacement of unsv 4 Pole on load changeover switch of following current carrying capacity 100 Amps including necessary additional/alteration to busbars of existing panel etc complete all as directed.
All as per srl item above but of capacity 125 Amps Capacity
All as per srl item above but of capacity 200 Amps Capacity
Taking out U/S control wiring complete from stabilizer of capacity 50 KVA to 100 KVA, 3 phase 415 volts any make for unbalanced load, Providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc. (Note: Additional items required to make stabilizers serviceable will be measured and paid for separately under respective items)
Supply only the following spares for carrying out repairs to voltage stablizer of capacity 50 to 100 KVA.
Voltmeter digital type LED display 50 to 550 Volts,AC supply of size 96x96mm acuracy class 1.0 .
Printed control card circuit
Limit switch
Toggle switch 2 way, 5 amps, 230 volts
Synchronous motor single phase AC 230 volts with torque up to 5 Kg/CM all as required or directed.
Control transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer
Push button
Variable resistance (pre set) with lock nuts
Resistant for synchronous motor, any rating upto 1K-10 W+10%
Dimmer stat
Brass stud with nut and washers
Carbon brush with Clamp
Taking out U/S control wiring complete from stabilizerof capacity 500 KVA, 3 phase 415 volts any make for unbalanced load, Providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc. (Note: Additional items required to make stabilizers serviceable will be measured and paid for separately under respective items)
Supply only the following spares for carrying out repairs to voltage stablizer of capacity 500 KVA.
voltmeter digital type LED display 50 to 550 Volts,AC supply of size 96x96mm acuracy class 1.0 .
Printed control card circuit
Limit switch
Toggle switch 2 way, 5 amps, 230 volts
synchronous motor single phase AC 230 volts suitable to work with voltage stabilizer of of any make and model with torque above 5 Kg/CM up to 12 Kg/CM
Control transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer
Push button
Variable resistance (pre set) with lock nuts
Resistant for synchronous motor, any rating upto 1K-10 W+10%
Dimmer stat
Brass stud with nut and washers
Carbon brush with Clamp
Taking out main transformer of the voltage stabilizer of capacity 50 KVA for repair/rewinding. Rewinding of the main transformer using super enameled copper winding wire of existing gauge including latherite paper, PVC sheets, sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixing to the stabilizer after testing all as required at site or directed.
Taking out main transformer of the voltage stabilizer of capacity 500 KVA for repair/rewinding. Rewinding of the main transformer using super enameled copper winding wire of existing gauge including latherite paper, PVC sheets, sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixing to the stabilizer after testing all as required at site or directed.
M & L for scraping old paint from the voltage stabilizer 3 phase 50 KVA to 100 KVA cap and preparation of surfaces for painting. Repainting the voltage stabilizers by spraying synthetic enamel paint of approved colour, writing SM/MES No and cap with white paint all as required at site or directed.
All as per Srl Item above here-in-above, but 500 KVA all as required at site or directed.
Taking out the old unserviceable battery and supply and fix new 12 V, 180 AH maintenance free battery including testing and commissioning complete all as specified and directed
Taking out the old unserviceable battery and supply and fix new 12 V, 100 AH maintenance free battery including testing and commissioning complete all as specified and directed
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like ballast, lamp, igniters, capacitors, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately. Note: (e) The Contractor shall depute manpower for attending/rectifying the defects/complaints on daily basis for each area/complex separately. Non rectification of complaints within 2 days time period after receiving complaints, recovery shall be at the rate of Rs 500/- per each complaint.
Dismantling LED light fitting of any makeof capacity 90 to120 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of any make of capacity 70 to 80 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of any make of capacity 40 to 60 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of any make of capacity 25 to 36 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2300 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 25 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2800 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 30 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4200 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6800 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: necessary clamps, nut, bolt and washer etc complete to be included in quoted rate.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 11000 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 120 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5700 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 9500 lumens and suitable wattage for efficiency not less than 95 lumens/Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.
Taking down old unserviceable street light fittings from any height and Supply & Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,with lumen output not less than 8500 lumens suitable wattage for efficiency not less than 95 lumens/Watt,min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc complete and testing on completion all as specified and as directed. Note: The GI pipe if rquired bracket will be measured and paid separately under relevant schedule items
Note for item No 51 to 61: (i) Driver Efficacy – more than 85% ( constrant current driver).(ii)Driver Type – Potted (iii) THD - < 10% (iv)Led Driver Current – less than 750 mA(v) Efficacy of Led Fixtrue – 100 lm/watt ( minimum) (vi) Efficacy of Led Chip – more than 130 lm/watt( Vii) Surge Protection – 4 KV & above as per IEC standard inbuilt in Driver and External SPD 5KV (vii) Working Humidity - 10% to 90% RH (ix) Led Make – Nichia/Philips Lumiled/ Cree /Osram/ Seoul (x) Life – 50,000 hours at 70% lumens(xi) CRI – more than 70 (xii) Lens – Each Led shall be of High Power ( 1 to 3 watt only) with mandatory modular lens. (xiii) Working Temp – 0 to 50 degree C. (xiv) Heat Sink – Pressure die cast aluminium (xv) Junciton Temp – 100 degree C (xvi) Body of Fitting – Pressue Die Cast with company logo / make engraved or embossed in housing LM 6 Grade.(xvii) Impact code – Min IK05 or more (xviii) LM79 report from Third Party ( instead of company in house lab) NABL /UL accredited lab. (xix) LM80 report from Led Manufacturer.(xx) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixtrue.(xxi) MS Clamp fittings with nut bolts and GI bracket, junction box included in the rate.(xxii) Test certificates to be submitted before commencement of work/ claiming for payment .(xxiii) Warranty certificate for minimum 2 years to be submitted from OEM.
Dismantling old unserviceable poles and Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (9.00 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under related items of Sch 'A'.
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.
S & F visibly glowing radiant heater consist of 2 tubes of 1500 watt, 230 V .single phase, AC 50 Hz with degree of protection IPXO class-I complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.
Supply and fixing timelite distribution boards (street light DBs) 63 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one .
Earthing complete with Galvanised Steel earthplate of size 60x60cmx6.3mm thick electrode and GI wire 8 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required,not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
All as per above item but exceeding depth 1.5 mtr and n exceeding 3 mtrs
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core. (Earth work to be measured and paid separately under relevant items).
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core. (Earth work to be measured and paid separately under relevant items).
Supplying and fixing in replacement of old u/s service cable size 4 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per above item but for service cable of size 6 sqmm,complete all as spd and directed.
Supply only the following spares suitable for LED street/Flood light fittings.
Potted type IP 65 electronic suitable for 90 to 120 W LED light fitting
Potted type IP 65 electronic suitable for 70 to 80 W LED light fitting
Potted type IP 65 electronic suitable for 30 to 60 W LED light fitting
Surge protection device of capacity 10 KV suitable for LED light fitting
Supply only the following spares suitable for street/Flood light fittings.
Tube rod 14 watt T-5
Electronic ballast 1x14 watt
Electronic ballast 4x14 watt
Lamp Holder suitable for suitable for MH/HPSV 70 to 250 W
Lamp Holder suitable for 30 to 50 watt High power LED
LED Lamp 40 watt with 4000 lumens output, PF>0.9
supply and fix in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.
M&L for preparation of old painted surfaces of 9 m long PCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.5 mtr height including applying a coat of white wash on pole coping and lettering the pole details with with white letters/ blackground etc complete all as directed
S & F in replacement of cone LED bollard 8 watt, 5700 K complete with all accessories including dismantling defective and connecting electrically all as specified and as directed.
Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for mass concretes or in any indicated positions etc complete all as specified
Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay complete all as specified
Plain cement concrete (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for foundation coping complete all as specified
M&L for replacement of existing UNSV schematic diagram with LED laminated display with openable transparent glass covered of main incoming and outgoing elect supply/water supply to various destination and generator supply destination all as directed and specified size of display not less than 1.5x3.0 mtr with all decoration as specified.
M&L for replacement of acrylic sheet diagram of main incoming and outgoing elect supply/water supply to various destination and generator supply destination all as directed and specified size of display not less than 1.0x2.0 mtr with all decoration as specified.
M&L for replacement of acrylic sheet DO and DON'T instructions in Hindi/Punjabi and English launguage for elect supply installations and water supply installatllations all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for replacement of acrylic sheet instructions for pump operation in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook,fire beater,sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismentling old unsv one.
M&L for replacement of electric shock and its management with picture in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.
M&L for replacement of Maintenance schedule of Sub stations instructions board on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M&L for replacement of Yearly periodical maint f HT Circuit Breakers on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M&L for replacement of DO's & DON’T's for HT circuit breakers on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.
M & L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by engr-in charge.
M & L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W inverter batten type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, charing time 10-12 hours and backup time 04 hours system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Supply and Fix in replacement existing UNSV tube light fitting with LED 20W batten type fitting 4 feet long aluminium extruded housing,IP-20 complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed. NOTE: (i) Driver efficiency more than 85% ( Constant current driver) (ii) Non isolated type driver (iii) THD less than 20% (iv) LED driver current less than 60 mA (v) Efficiency of LED Chip more than 130 lm/watt (vi) Efficiency of LED Fixture 100 lm/watt (vii) Surge protection 2.5 KV & above as per IEC standard (viii) working humidity 95%RH (ix) LED Make Nichia /Philips lumiled/ Cree/Osram/Seoul/Bridgelux/Nationsear (x) Life 50000 Hrs at 70% lumes (xi) CRI more than 80 (xii) Working temp -10 degree to 50 degree C (xiii) Heat Sink extruded aluminum (xiv) junction temperature 85 degree C (xv) Body of fitting Extruded Aluminum (xvi) impact code Min IK 03 or more ( xvii) LM79 report from thir party (instead of company in house lab) NABL/UL accredited lab (xviii) LM 80 report from LED manufacturer (xix) Low/High voltage, reverse polarity, overload and short circuit protection inbuilt in fixture (xx) IP-20 .(xxi) Test certificates to be submitted before commencement of work/ claiming for payment .(xxii) Warranty certificate for minimum 2 years to be submitted from OEM.
Dismantling old defective/peeled of Insulating Mat and M&L for Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 3.3 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.00 mm+/- 10% of approx width 1 mtr along with suitable adhesive /chemibound resin waterproofing compound and sealing material all as per manufacturers' recommendations complete all as specified and directed.
Dismantling old defective/peeled of Insulating Mat and M/L for Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 11 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.50 mm+/- 10% of approx width 1 mtr along with suitable adhesive /chemibound resin waterproofing compound and sealing material all as per manufacturers' recommendations complete all as specified and directed.
M & L for flex board outdoor type with acrylic sheet mounted on aluminium framed supports box type of size 900mmx600mm with duly supported by 40 mm size SS tubing round the box incl stand of hight not less than 1.5 mtrs from the gorund level with LED 2x9watt lighting arrangement complete. Note: PCC will be measured & paid seperately
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii)super enameled copper winding wire shall only be used.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item 121 above but 3.15mfd complete all as spd.
All as per Srl item 121 above but 4mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S & F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
S & F PVC Two way connector for ceiling fan complete all as specified and directed.
Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/site requirement/Make of fan complete all as spd.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/industrial wall mounting fan/pedstral fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) super enameled copper winding wire shall only be used.
All as per Srl item 133 above but 400mm-450mm sweep complete all as spd and directed..
S & F louver, suitable for exhaust fan of any make and size upto 300 mm, fixed in repair complete all as specified and as directed.
All as per items 135 above but of size 400 mm
All as per items 135 above but of size 450 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Taking down carefully from wall after unscrewing nut/bolts geysers 50/25 ltr capacity and strip opening the same for taking out internal tank, syphon assembly etc and re-assembling and re-fixing after repair, spares to be replaced shall be measured under respective items of Sch here-in-after.
Supply and replacement internal copper/SS tank of geyser 25 ltr ISI marked capacity complete with syphon –assembly, 1.5/2.0 kw element , rubber gasket , thermostat switch , all as specified and directed. The tank shall be tested at site and shall be able to with stand the requisite pressure. Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
Supply and replacement of syphon assembly ISI marked made out of brass of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed.
Supply and replace thermostat switch ISI marked for geyser AC 230 volt adjustable range from 0-90 degree Celsius )
Supply and replacement cup type geyser element AC 230 volt, of rating 1500/2000 watt.
Supply and replace triangular type geyser element AC 230 volt, of rating 1500/2000 watt.
Supply and replacement outer body suitable for 25 ltr geyser made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified and directed.
Supply and replace glass wool of 25 ltrs capacity geyser complete all as specified and directed by Enginner-in-Charge.
Supply and replace indicator lamp square type suitable for geyser 25/50 ltr all as per sample AC 230 Volt.
Supply and replace indicator lamp round type suitable for geyser 25/50 ltr all as per sample AC 230 Volt.
Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
De-scaling of geyser of capacity 25/50 ltr after taking down the geyser from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of geyser complete all as directed by Engineer-in –Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
Replacement of spring loaded air release valve ISI marked suitable for 25 and 50 ltrs capacity Geysers.
Replacement of safety valve / dead wt. valve ISI marked suitable for 25, and 50 Ltrs capacity geysers.
Supply and replace pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm .
Supply and fix gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
Supply and fixing anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Supply and replace brass non return valve suitable for 25/50 ltr geyser of size 15 mm.
Supply and replace bottom cover plate of geyser of capacity 25/50 ltr complete with MS screw all as per sample.
Dismantling of Insulated hot water storage tank of capacity 200/300/500 Ltrs connected Solar Evacuated collectors/flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S & F in replacement of Evacuated tube collector for Solar Water Heater of capacity 200 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
Supply and fix in replacement of rotational moulded polyethylene water storage tank three layer of 1000 Ltr storage cap with float valve with proper fixing on stand with Including suitable connected with accessories as specified or directed by Engr-in-carge (Note: MS Angle measured and paid separately)
S&F laminated sticker of size 8"x12" having background of navy blue and letters of white colour as directed by Engr-in-charge. The words shuold have in capital letters. The following do's and don't shall mentioned of the sticker :-
(i) The geyser should be switched on 60 to 75 minutes before the actual time when hot water is required.
(ii) Switch off the geyser during night.
(iii) Switch off the geyser when not required for 3 to 4 hours continuously.
(iv)The indicator lamp indicates that the current is passing through the heating element and water heater is working.
(v) In case any water leak is noticed from any part of geyser including accessories, should be reported to MES.
DON'TS
(i) Don’t Keep the geyser switched on during night or at the time when not required.
(ii) Don't adjust the high pressure reducing valve.
(iii) Don't use the geyser when indicator lamp is not working.
(iv) Don't use the geyser when three pin plug with necessary earthing connection have not been provided.
(v) Don't switch on the geyser if water does not come out from the delivery tap.
(vi) Don't close inlet water stopcock.
Sch of Credit = 105795.00
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
SATISH AND CO
KEWAL SONS
Abrol construction co
M/S Vijay Punj Constructions
Vijay Kumar Contractor and Engineers
INDERJIT SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .