Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.7 L+₹35,528 (2.47%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹29,400
EMD Value
₹29,400
Closing Date
18 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-41/2020-21 CERTAIN REVENUE AND MINOR WORKS UNDER AGE B/R-II OF GE (NORTH) UDHAMPUR
2020_MES_364882_1
GE/U(N)-41/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
Yes
GE (NORTH) UDHAMPUR
₹29,400
Yes
16 Sept 2020
28 Jul 2020
20 Aug 2020
28 Jul 2020
18 Aug 2020
11 Aug 2020
60 days
Amount
Excavation in post holes or similar holes, each n. exc o.5 cum, getting out, returning in and ramming earth around in layer n. exc 25 cm, watering and removing surplus soil to a distance n. exc 50 mtr and making good surface, in any type of soil, complete all as specified and as directed..
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and as directed..
PCC 1:3:6, type C-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete surface drain etc, complete all as specified.
PCC 1:4:8, type D-2 (40mm graded stone aggregate) as in foundation, filling and mass concrete , etc, complete all as specified.
Rolled mild steel section as in roof trusses ( framed ) trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing ( beam, tee, angle, channel or flat sections including distance pieces etc, conforming to Fe-410 W ( Gde- E- 250 ) quality-A, complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick covering/cladding at the external end slop of any colour having tensile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc ccomplete all as specified and directed.
Framed work as in door or gates of angle or other section with gusset plates, rails braces etc cmplete drilling for fixing or steel sheeting or other covering confirming to fe 410-0 or fe 310-0
Rolled mild steel tubular work as in trusses (framed) and similar works complete using ERW or induction butt welded tubes conf to is 1161-1998grade st-240 all as specified and as directed by Engr-in-charge.
Preparing new or previously un -treated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and as directed.
Removing excavated material ( soil ) to a distance n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point, complete all as specified and as directed.
Brick work with sub class 'B' bricks, using old size bricks, straight or curved on plan exceeding 6 metre mean radius,built in cement mortar 1:4 , complete all as specified .
Brick work with sub class 'B' bricks, using old size bricks, straight or curved on plan exc 6 mtr mean radius, built in cm 1:6, for parapet wall/ railings/manholes /drains etc complete all as specified and as directed.
Brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified.
Preparing new decorated surfaces of walls and applying two coats of cement base paint over 1 coat of wall care putty over 1 coat cement primer, complete all as specified .
Preparing new plaster decorated surfaces of walls and applying two coats of cement base paint over 1 coat cement base primer, complete all as specified .
15mm thick rendering in two layers (10 + 05mm) with WPC at external layer on fair faces of brick/concrete surfaces including Chajjas and facias etc, in cement mortar 1:4 and finished fair and even mixed with water proofing compound as per manufacture instructions for external layer of plaster, without using extra cement, complete all as specifed and as directed. Note : WPC shall be measured and paid seperately under relevant items.
15mm thick rendering on fair faces of brick /concrete surface in cement mortar 1:6 and finished even and smooth without using extra cement, all as specified .
Rendering 5 mm thick plaster on ceiling surfaces including three coat of white wash over newly plastered surfaces complete all as specified.
Preparing plastered or unplastered new surfaces of walls and applying three coats of white washing,complete all as specified .
Preparing plastered or unplastered new surfaces of ceilings and applying two coats of white washing,complete all as specified .
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc, or for shafts, wells, cess pits, manhole, pier holes etc n.exc 10 sqm on plan and n. exc 1.50mtr in depth and getting out in for any type of soil, complete all as specified and as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil , complete all as specified and as directed .
Precast cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in louvers and jallies 50 mm thick (measured solid )and similar articles , set in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge. .
Precast cement concrete 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in louvers and jallies 25 mm thick (measured solid ) and similar articles , set in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge. .
Granite stone slab 15mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of marble laid over & including 10 mm thick rendering/screed bed in CM (1:3) complete all as specified and as directed by Engineer-in-Charge.
Cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as cills, steps, s copings,, appex stones, bed plates, and necessary similar works including form work etc, complete all as specified and as directed.
Hardcore of guage exc 63mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface.
Use and waste of formwormk to side of concrete foundation, footings, bases of columns, rafts and raft beams, side and soffit of foundation and plinth beams flat, for rough finished surfaces of concrete
Formwork to edges of concrete flats, breaks in floors, treads openings in concrete walls, floors & roofs & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work all exceeding 20cm wide.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)
Formwork to Sides of pillar/column square or rectanglar all as specified & directed by Engr-In-Charge.
TMT steel bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.all as specified & directed by Engr-In-Charge
-do- but 6 to 8mm dia or as in stirups
RCC Type B1 1:2:4 (20mm graded aggregate) as in any type of beam like Plinth beam cantilivers bressummers lintels over 1.5 m span etc all as specified & directed by Engr-In-Charge.
RCC type B1 (1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like including 15 mm th plastering with water proofing compound as directed laid/made to slope as in RCC roof surfaces complete all as directed .
RCC type B1 (1:2:4) as in columns, pillars etc all as specified & directed by Engr-In-Charge.
75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as in weep holes all as specified & directed by Engr-In-Charge
110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as in weep holes all as specified & directed by Engr-In-Charge
Powder coated aluminium partition of section (65x65)mm & vertical members (44x44) with top,bottom, with vertical members (65x65)mm complete including 12mm thick prelaminated exterior grade sound proof partical board solid both side decorative finished complete including fully fixing incl all beading rubber gasket & complete builder hard ware all as specified & directed by Engr-In-Charge / GE.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-30 Grade including 25mm thick sand cushion bed and including speading laying, watering if required complete with all as specified and directed ny Engr-in-Charge.
Cement concrete 50mm thick type B-1 (1:2:4) using 20mm graded stone aggregate finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
Glazed ceramic colour tiles 450x300x7mm thick as in vertical surfaces set & jointed in neat cement slurry & pointed in white or colour cement to match. including rendering 10mm thick cement plaster on fair faceof brick work in cement mortar 1:4 as in backing coat for wall tile/ kota stone.all as specified & directed by Engr-In-Charge
Providing pre-cast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in kerb stones and in similar works bedded and jointed in cement morter 1:6 including necessary excavation if necessary all as specified & directed by Engr-In-Charge
Two coat of synthetic enamel paint over concrete surfaces (In multi colour strips), over 10cm in width or girth, not otherwise described all as specified & directed by Engr-In-Charge
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises, all as specified.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm dia
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall (concealed type) and ceiling or laid in floors of 15mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall (concealed type) and ceiling or laid in floors of 20mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall (concealed type) and ceiling or laid in floors of 25mm bore all as specified.
Stop cock fancy type Cromium plate concealed for 15mm bore complete all as approved
Bib taps Cromium plated for 15mm bore long bodyall as specified & directed by Engr-In-Charge.
PVC connections 15mm size with PTMT nuts of length 450mm all as specified & directed by Engr-In-Charge
PVC valve less syphonic action type flushing cistern 10 Ltr capacity low lavel coloured with inlet ball valve float and handel brackets all as fixed in repair.
Vitrified ceramic tiles any colour 10mm thick(Square or rectangular) poliahed, area of each tile not exceeding 0.36 sqm in floor etc,Set and jointed in neat cement slurry and pointed in coloured cement to match including bedding layaers of CM 1:4 (20mm thick) all as per specified & directed by Engr-In-Charge.
Non skid ceramic colour tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match. including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:6 all as specified & directed by Engr-In-Charge
Non skid coloured glazed ceramic tiles area of each tile exc. .11 sqm but n.exc. 18 sqm 7mm to 8mm mm thick as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed of cement mortar(1:4) all as specified .
Preparing of old surfaces as on wall incl complete removed of existing treatment and applying two coat of oil emulsion distemper over a coat of birla wall care putty all as diected by GE/Enge-in-charge.
Preparing newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of birla wall care putty all as specified .
PVC (SWR) floor trap plain with grating including jointing with solvent 75mm
Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rail with suitable PVC sheet beading, & joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings.
100mm long butt hings medium weight cold rolled mild steel with Brass screws all as specified & directed by Engr-In-Charge
But hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100 mm long all as specified & directed by Engr-In-Charge
Extruded aluminium ally handles, fabricated type., anodised all as specified & directed by Engr-In-Charge
Aluminium, anodised, barrel tower bolts of extruded section and fixed, 125 mm all as specified & directed by Engr-In-Charge
Aluminum anodised barrels tower bolts with bright both 150mm long all as specified & directed by Engr-In-Charge
Alunminium handle cast type 150mm long oval type all as specified & directed by Engr-In-Charge
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware complete all as specified and directed by Engr-in-Charge .
Wash basins, vitreous China flat back, size 550 X 400mm incl CP pillar tap, 32mm size waste coupling, 15 x 450 mm long PVC connection, 32mm size PVC waste pipe & angle brackets 30x30x450mm complete.
Vitreous china wash down water closet pan `P` or `S` trap ( pedestal pattern ) white including fixing bolts,including connection to drain pipe ( or out going pipe) and to flushing pipe,antisyphonage pipe etc complete.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type ,screwed down high pressure, with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe of dia 15 mm , complete all as specified.
Hand shower (health faucet) brass chromium plated fncy type all as specified & directed by Engr-In-Charge
Towel rail 600mm long aluminium tower bolts 20mm D type all as specified
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
Chromium plated shower roses with or without swivel joints, any size, including fixint to steel pipe or union all as specified & directed by Engr-In-Charge
PVC bathroom cabinets quality as approved by Engr-in-Charge, of size 600mm400mm with mirror on front door and with one towel rail for hanging towel of MS chromium plated fixed with screw and wooden gutties etc complete.
40 mm th PCC 1:2:4 type B0 using 12.5 mm graded stone agg as in damp proof course to horizontal or vertical surfaces including necessary formwork all as specified & directed by Engr-In-Charge
75mm th PCC 1:5:10 type E2 using 40 mm graded stone agg as in sub base flooring all as specified & directed by Engr-In-Charge
Earth filling under floors including watering and consolidation complete (earth shall be used from excavation free from vegetation, pebbelse/foreign materials all as specified & directed by Engr-In-Charge
Material and labour for 50mm thick plain cement concrete type C-1 1:3:6(Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed. Note : The plinth protection shall be laid in panels and length of the each panel shall not be more than 2.00 metre all as directed. 6mm joints filled with 85/25 grade bitumen and sand (1:3 ratio) shall be provided. No deduction for joints shall be made while making payment against the above item.
Supply only integral water proofing compound all as specified & directed by Engr-In-Charge
Vitreous china squatting pan ( Orissa pattern), size 580 x 440mm, white, with ‘P’ or ‘S’ trap front or back ( excluding flushing cistern & flush pipe fixed as in repair including making good the disturbed surfaces and to match with existing surface, complete all as specified and directed.
Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40 gms) all as specified & directed by Engr-In-Charge
Cast iron soil, waste and vent pipe 75mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed.
CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed.
Sheet glass 3mm thick, ordinary quality and glazing with oil putty or fixed in alu beading, in square not exc 0.5 sq.m in each pane all as specified & directed by Engr-In-Charge
M&L 40 mm thick flooring in PCC 1:2:4 type B1 using 20mm graded stone aggregate surfaces finished even and smooth using extra cement (staircase incl steps). all as specified & directed by Engr-In-Charge
Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I,capacity of water tank 500 Ltr all as specified & directed by Engr-In-Charge.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed all as specified & directed by Engr-In-Charge
S & F aluminium hooks (single) 50mm to 60mm all as specified & directed by Engr-In-Charge
Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms)
Supply and fixing PVC (SWR) gully trap of size 150 x 110 mm, setting and jointing with solvent cement complete all as specified & directed.
15mm angle valves (chromium plated) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified & directed by Engr-In-Charge
Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
Salt glazed stone ware drain pipes of internal diameter 150 mm, grade 'A' quality, laid in trenches and jointed in cement, complete all as specified and as directed .
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. .
Cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as in surface channel or drain etc, complete all as specified and as directed.
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed .
Cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) smooth finished, and reforming benching complete all as specified and as directed.
XLPE insulated, screened PCVbeded,Galvansied steel ,wire armoured electric power cable strip , heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 10 sqmm, 2 core, laying on surface of wall/trenches/pipes all as per site requirement complete with connecting acessories including complete all as per specified and directed.
Dry sand cushioning to underground cable provided with a layer of 8cm deep before laying the cable and 15cm dee after laying the cable and stretching the cable, complete all as specified and directed.
Laying brick as mechanical protection to cables with well burnt sub class 'B' bricks, laid as width of brick equal to the length of the cable, complete all as specified and as directed.
GI tubing light grade with all fixing arrangements, fixed comlete to wall, trench or laid in floors, size of pipe 40 mm bore, fixed in repair, complete all as specified and as directed.
Cutting of road n.exc 45cm depth and n. ex 30cm width for laying of Gi tubing for protection of cable incl making concrete in ground floors and paving all as per exisiting complete all as specified and as directed
Point wiring with 1.5 sqmm, PVC insulated but unsheathed, multi- stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 1.5 mm thick, 20mm dia , or higher complete with all PVC conduit accessories / fittings ISI marked and sunk type pressed steel anodised terminal switch boxes anodised, plastic laminated sheet top cover 3mm thick, brass screws and cup washers including 1.50 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor to common earth and connected to earth dolly with all accessories complete all as specified and directed for One light point, bell or fan point controlled by one, single pole, one way switch, 5 amps complete all as specified and as directed.
All as per item No 109 here in before but for One switch socket outlet 3 pin, SP, 5 Amp, 240 Volt, on independent board.
All as per item No 109 herein before but with 2.5Sqmm cable PVC insulated but unsheathed, multi- stranded copper conductor single core FRLS cable, IS-694 marked with 1.5 Sqmm cable green in colour as continous earth conductor for3 pin 5/15 Amps switch/socket outlet on independent board.
Switch piano flush type 5 Amps 240 volts one way complete all as specified and directed.
Switch piano flush type 15 Amps 240 volts one way complete all as specified and directed.
Socket outlet, 2-in-1, 3 pin 5 Amp Amps combined complete all as specified and directed.
Socket outlet flush type one way SP 15 Amp suitable for 240V,50hz, AC supply complete all as specified and directed. .
Ceiling rose, surface bakelite 65x 50mm, 3 terminals isolated body , complete all as specified and directed .
Decorative ultra slim linear LED lighting fixture 20 watt LED complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit complete all as per directed by Engr-in-charge. Make Havells cat part no. LHEXBLP7IN1W020 or equivalent in Surya/Philips or equivalent in any MES approved make.
Slim linear LED lighting fixture 4W watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the directiong of Engr-in-Charge. Make - Make of LED - SYSKA as per ordering code SSK-SQ0401-4W or equivalent model of Havells or CG
Earthing complete with galvanized steel earth plate electrode of size 600 x 600 mm x 6mm thick buried directly in ground (Earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers all shown in electrical plate No.3 of SSR Part-I connected to main board /DB complete. Earthing GI lead and GI protection pipe 15mm dia light grade upto 7.50m from earth pit connecting to machinary/equipment, testing point, all as specified and testing on comletion all as specified and as directed. Note - (i) The unit rate shall also included for earth work in any type of soil, PCC type C-I (1:3:6) chamber, PCC 1:2:4 type B-I cover 50mm thick reinforced with 8mm dia TMT bars, 150mm c/c both way, funnel with waterning pipe 20mm dia medium graded, GI protection pipe light grade 15mm dia and wire mesh with funnel (ii)Earthing shall be tested as specified in clause 19.137 of SSR Pt I 2009. After testing if desired earth resistance is not obtained, the earthing shall be re-done by the contrac to the entire satisfication of EIC, at his own risk and cost.
Sheet metal enclosure for DBs ( when MCB to be used) 04 way, SPN, 240 volts with 200 Amps rated busbar and neutral link, double door type , fixe,Conforms to IS 13032.DBs are phosphatised and painted with Epoxy polyster based powder paint, complete all as specified and as directed.
MCB SPN, 40 Amps, 240 volts, rupturing capacity 10 KA "C" Series, complete all as specified and as directed.
MCB SP, 6 to 32 Amps, 240/415 volts, 50Hz rupturing capacity 10 KA "C" Series,conforming to IS 8828: 96, complete all as specified and as directed.
Exhaust fan of 150 mm sweep plastic body, single phase, AC 240 volt with louver including all fixing arrangement, fixed in wall, making hole, grouting bolts on wall and making good the disturbed surfaces including 1.50 sqmm twin core copper flexible wire from ceiling rose/DB to fan, complete all as specifed and as directed. Make : Bajaj, Havell's., Crompton Greaves.
devraj chalotra
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .