Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.4 L+₹28,000 (1.46%)Rejected-AOC 17 A SUBASH CHANDRA BOSE STREET MELAKARUNKULAM POST PALAYAMKOTTAI TALUK TIRUNELVELI 627 356 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627356 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.8 L+₹63,755 (3.33%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹19.8 L+₹67,350 (3.52%)Rejected-AOC CHENNAI | L4 | Rejected-AOC Rejected | |
| 5 | L5₹19.9 L+₹79,580 (4.16%)Rejected-AOC VIVEKA HOME 207 D UDANGUDI ROAD TISAYANVILLAI 627657 TIRUNELVELI | TISAYANVILLAI | TIRUNELVELI | TAMIL NADU | 627657 | L5 | Rejected-AOC Rejected |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
24 Feb 2024, 6:00 pmClosed
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
MAINTENANCE OF WATER SUPPLY INSTALLATIONS AND REPAIRS /REPLACEMENT OF WATER SUPPLY PIPE LINE AND ITS CONNECTED ITEMS AT SESS PALAYAMKOTTAI UNDER GE TIRUNELVELI
2024_MES_640324_1
GE/TVL/8349/E8 of 2023-24
Open Tender
Civil Works - Water Works
Item Rate
180 days
Palayamkottai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹38,000
Yes
25 Mar 2024
2 Feb 2024
26 Feb 2024
2 Feb 2024
24 Feb 2024
17 Feb 2024
3 Feb 2024 - 12 Feb 2024
Amount
Material and labour for taking up submersible pump set 7.5 HP from Deep well, 3-phase 415v,50Hz, AC, opening the motor, cutting and removing the burnt windings, cleaning the starter and rotor with cleaning agent, rewinding the motor with appropriate gauge of super enameled copper wire of approved make insulating the winding with same class of insulation complete all as specified and directed.
Material and labour for spray Painting of motor/ pump, Two coat enameled paint before one coat of red oxide paint including scraping and writing MES/SM No complete all as specified and directed of the following capacities.
Excavation in trenches for laying of GI water tubing etc., getting out in soft/loose soil n.exc 1.5m wide and n.exc 1.5m depth complete all as specified and directed.
Returning, filling in trenches including spreading, leveling, watering and in layers n.exc 25cms thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Repair/Replacement of CPVC pipe line checking and arresting of leakage at both ends, testing of leakage after rectifying , complete of the following size of pipe as specified and directed.
a) 75 mm dia (inner)
b) 62.50 mm dia (inner)
c) 50 mm dia (OD) SDR II
d) 40 mm dia (OD) SDR II
e) 32 mm dia (OD) SDR II
f) 25 mm dia (OD) SDR II
Material and labour for purichloro (65 - 70%) calcium based granular disinfectant for water treatment more stable than chlorine gas and stronger than bleaching powder and sodium hypochlorite in 45 kg Drum complete all specified and as directed.
Material and labour for disconnecting /removing the old unserviceable starters parts from the panel and supply and fixing faulty contactor with relay for fully automatic star delta starters for AC 415v, 50Hz, 3-phase suitable upto 7.5 HP capacity electric motor complete all as specified and directed .
Supply only of Sand, Silex and Pebbles for MGF ACF filters of different sizes as per specified for the sizes 800mm dia of vessel complete all as specified and as directed by Engineer-in-Charge (a) MGF (b) ACF .
Supply only of resin with strainer 30 Nos for filters as per specified for the size of vessel of Softener complete all as specified and as directed by Engineer-in-Charge.
Supply only of activated carbon for ACF coconut shell of activated carbon IV 900 complete all as specified and as directed by Engineer-in-Charge
Supply of EPDM Rubber gasket, 5mm thick for vessels 800 OD to 700 ID complete all as specified and as directed by Engineer-in-Charge.
Supply only nut, bolt and washers for dish of vessels of size 15mm (D) x 62mm (L), having a set of (1 bolt + 01 nut + 02 Washers) complete all as specified and as directed by Engineer-in-Charge.
Labour only for taking out/ disconnection of disinfection system, PSF, ACF, Softener & Brine system including removal of old filter media of 03 vessels including rubbing and cleaning, loading of new filter media and fixing of valves of all 3 vessels including patch/ welding, fabricating, refilling, replacing defective/ rusted portion complete all as specified and as directed by Engineer-in-Charge.
Material and labour for construction of block masonry valve pit complete with PCC 1:3:6 type C1 solid block walling 20cm thick set in CM (1:4) over 100 mm thick PCC 1:4:8 type D2 foundation, 50 mm thick PCC 1:2:4 type B1 coping on the top of wall, rendering 15 mm thick with CM 1:4 on inside and exposed external surfaces up to 150mm below GL, 3 mm thick MS sheet cover, angle iron frame and locking arrangement etc., including dismantling old existing damaged valve pit complete of following sizes all as specified and directed:-
a) 0.75m x 0.75m x 0.75m
b) 1.2m x 1.2m x 1.0m
Supply and fixing stainless steel name sign board made out of wide angle cube corner micro prismatic grade sheeting type XI retro reflective and fixed over 2 mm thick aluminium sheet and back support frame of 25X25X3mm angle frame supported by 380D stainless steel pipe and 760D pipe stainless steel vertical post grade 304 of size as specified including letters writing both sides, necessary required PCC of size 600x600X600mm all as specified and directed by engineer-in-Charge.
Supply and fix for Ball valve (ISI) marked suitable for CPVC pipe with wheel head screwed both ends for pipe suitable for following bore of pipe including taking down old existing valve complete all as specified and directed.
a) 50 mm bore pipe
b) 40 mm bore pipe
e) 32 mm bore pipe
c) 25 mm bore pipe
Supply and fix in repair of Single phase 1 HP open well submersible Pump with CI Impeller, Gland packing suitable for fixing all as per required at site and specified by OEM complete all as specified and directed.
Material and labour for PVC Insulated and PVC Single core Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts, 4 Sqmm, Single core suitable for 1HP to 3 HP submersible motor complete all as specified and directed by engineer-in-Charge.
Supply and fixing of good quality Raingun type sprinkler automatic HT-40G Penguin 1.25" inch rain gun with female threaded, heavy duty, brass nut, tube, nozzles with stainless steel Pivot Pin and nut and bolt with proper fixing arangement complete all as directed by Engr-in-Charge.
Material and labour for taking out/lifting of submersible pump with submersible cable, supporting wire and column pipe and lowering after completion complete all as specified and directed by Engineer-in-charge.
Material and labour for flushing of borewell through high pressure air compressor upto satisfaction level and carring out yield test for the same bore well before and after flushing complete all as specified and directed.
Checking and arresting of HDPE pipe line for leakage at both ends, testing of leakage after rectifing, complete all as specified and directed.
Material and labour for cleaning and washing of inside portion of semi under ground sump (square) of capacity 60000 Ltrs at SESS Palayamkottai by pumping out complete water including removing of sand/ mud/ slit/ sludge and deposit the mud/ sand to a distance of 50mtr away from UG Sump cleaning the bottom floor and inside wall using wire mesh brush/ scrubber and washing of inner surface using lime and bleaching powder and applying one coat white wash on inner surface, black synthetic enamel paint single coat in metal surface of ladder/ manhole covers etc. and refilling of water through water bowser as specified including writing tank capacity and cleaning date with white paint on the base in black paint complete all as specified and directed by Engineer-in-Charge.
Material and labour for attending breakdown complaints like no water supply in service tank, pipe line leakages etc and also removing air lock in married / OTM accommodation with help of required tools and fixing of GI fittings of any size/dia like union, elbow, tee, bend, nipple, socket complete all as specified and directed. Note: Quoted rate is deemed to be inclusive of the fittings required for repair.
M/S VIGNESH POWER SYSTEM
THIRUMURUGAN ENTERPRISES
VVM CONSTRUCTIONS
Vinayaga constructions
JR ENTERPRISES
J L CONSTRUCTIONS
CHANDRASEKRAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .